PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pupil dynamics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Characterization of pilocarpine-loaded chitosan/Carbopol nanoparticles.

Patients using ophthalmic drops are faced with frequent dosing schedules and difficult drop instillation. Therefore, a long-lasting pilocarpine-loaded chitosan (CS)/Carbopol nanoparticle ophthalmic formulation was developed. The physicochemical properties of the prepared nanoparticles were investigated using dynamic light scattering, zeta-potential, transmission electron microscopy, Fourier transform infrared ray spectroscopy (FT-IR) and differential scanning calorimetry (DSC). The sustained-release effects of pilocarpine-loaded nanoparticles were evaluated using in-vitro release and in-vivo miotic tests, and compared with pilocarpine in solution, gel and liposomes. We found that the prepared nanoparticles were about 294 nm in size. DSC and FT-IR studies suggested that an electrostatic interaction between CS and Carbopol contributes at least in part to the stabilization of pilocarpine/CS/Carbopol nanoparticles. When compared with pilocarpine in solution, gel or liposomes, the best slow-release profile of pilocarpine from the prepared nanoparticles occurred in a dissolution test. In the in-vivo miotic study, pilocarpine-loaded CS/Carbopol nanoparticles showed the most significant long-lasting decrease in the pupil diameter of rabbits. The advantages of CS and Carbopol are good biocompatibility, biodegradability and low toxicity. CS is also a mucoadhesive polymer. Thus, pilocarpine/CS/Carbopol nanoparticles may provide an excellent potential alternative ophthalmic sustained-release formulation of pilocarpine for clinical use. CS/Carbopol nanoparticles may also be useful for a variety of other therapeutic delivery systems.

Acrylic Resins↗

Psychophysiological reactions in methadone maintenance patients do not correlate with methadone plasma levels.

In methadone maintenance therapy methadone plasma concentrations of 400 ng/ml are necessary to suppress any further opiate action and to provide stabilized maintenance. In a controlled study we have searched for a differentiation in autonomous activation between patients having low and high methadone plasma levels, using static and dynamic pupillometry and habituation of skin conductance response. Results show that there is no difference in psychophysiological response between patients with high (greater than 400 ng/ml) or low (less than 400 ng/ml) plasma levels of methadone. This indicates that there is no reduction in behavioral arousal in patients with high plasma methadone levels. On the basis of these findings, there is no rationale to maintain patients on plasma levels below 400 ng/ml.

Adult↗

Accommodative fluctuations in Adie's syndrome.

Recent reports suggest that the higher frequency components (around 2 Hz) of accommodative fluctuations may arise from the accommodative 'plant' and may have no role in the control of the accommodation system. The dynamic responses of accommodation in two cases with Adie's syndrome were recorded. The results showed that the velocity of accommodative responses was reduced, and the accommodative fluctuations in the higher frequency components were completely diminished. It can be concluded that the origin of fast fluctuations is not located at a more peripheral site than the lesion of tonic accommodation. Since the possible lesion exists at the ciliary ganglion, the origin of the fast oscillation may not be the accommodative 'plant', but the neural one.

Accommodation, Ocular↗

Effect of ethacrynic acid on aqueous outflow dynamics in monkeys.

PURPOSE: To determine the long-term effect of ethacrynic acid (ECA) on aqueous outflow dynamics in ocular normotensive monkeys. METHODS: (1) Twelve cynomolgus monkeys received 10 microliters of 2.5 mM (= 7.5 micrograms) ECA intracamerally in one eye, vehicle in the other; outflow facility (perfusion) was determined at 1 hour, 24 hours, or 1 week, and intraocular pressure (IOP; applanation) at 24 hours, 1 week, and 6 to 7 weeks later. Six other cynomolgi received 10 microliters of 0.13 or 1.3 mM phalloidin in one eye 45 minutes before receiving ECA OU; facility was measured 1 hour after ECA. (2) Groups of five rhesus monkeys underwent intracameral injection of 2.5, 5.0, or 10 micrograms ECA in one eye, vehicle in the other, with IOP measured hours to weeks thereafter. (3) Five rhesus monkeys received 540 micrograms of ECA unilaterally as a 30-microliter topical drop once daily for 4 days. On the first and fourth treatment days, baseline IOP, pupil diameter, and refraction were measured immediately before and again at 2, 4, and 7 hours after topical treatment. RESULTS: (1) ECA divided by vehicle facility averaged 1.83 +/- 0.23 (SEM) (P < 0.02, n = 6), 1.50 +/- 0.27 (P < 0.11, n = 7), and 1.05 +/- 0.10 (n = 7) at 1 hour, 24 hours, and 1 week, respectively. IOP was 1 to 2 mm Hg lower in ECA eyes 24 hours (P < 0.05, n = 5) and 6 to 7 weeks (P < 0.05, n = 7) after treatment. Phalloidin did not diminish the 1-hour ECA facility effect. (2) Five (but not 2.5 or 10) micrograms of ECA lowered IOP 1 to 3 mm Hg, starting at 2 hours and lasting up to 48 hours. The maximum ECA effect (-2.6 +/- 0.25 mm Hg; P < 0.001, n = 5) occurred at 4 hours. IOP, corneal thickness and endothelial cell count, and anterior chamber depth were not significantly different 8 weeks after 5 micrograms ECA or vehicle. (3) Once-daily unilateral topical application of 540 micrograms of ECA induced no change in IOP, refraction, or pupil diameter compared to contralateral vehicle-treated control eyes. There were no significant ECA-related ocular bio-microscopic abnormalities. CONCLUSIONS: ECA may lower IOP and increase outflow facility longer than previously thought, but not by affecting meshwork actin filaments.

Animals↗

Perception of random-dot symmetry and apparent movement at and near isoluminance.

There have been conflicting reports on whether apparent movement in random-dot kinematograms is abolished at isoluminance. The present results suggest that it is, provided that dynamic (uncorrelated) surrounds are used, and the subject has to report the shape of the target rather than the presence of movement in an isolated portion of the target. On the other hand, perception of random-dot symmetry is still possible at isoluminance. The reason for this difference appears to be the need for exact-position information in movement but not symmetry perception. Control experiments suggest that the effects are not due to artefacts such as chromatic aberration in the eye.

Adult↗

A 'minimum-wear-and-tear' meshwork for the iris.

Large changes in pupil size occur frequently, yet the connective tissue components of the iris, consisting largely of relatively-inextensible collagen, last for many years. The concept of a minimum-wear-and-tear meshwork is developed in the context of the iris geometry, and an optimum form for such a meshwork is derived. A moderate improvement on the performance is obtained by allowing the iris to stretch nonlinearly. Comparison of the optimum mesh and stretch behavior with available data suggests that the iris may approximate a structure which minimizes wear and tear.

Biomechanical Phenomena↗

Inhibition by MIF-I of alpha-MSH induced increase of intraocular pressure and miosis in rabbits.

The effects of intracameral (i.c.) administration of MIF-I on the ocular response to alpha-MSH were tested in rabbits. In confirmation of previous studies, i.c. alpha-MSH significantly increased intraocular pressure (IOP) and reduced pupillary diameter (PD). Concomitant administration of alpha-MSH and MIF-I antagonized both the IOP increase and miosis induced by alpha-MSH. Aqueous humor (AH) dynamics studies revealed that alpha-MSH increases IOP, possibly, by decreasing AH outflow. The decreased AH outflow induced by alpha-MSH was antagonized by concurrent administration of MIF-I and alpha-MSH. MIF-I did not affect IOP or PD when administered alone. These results add more support for a role of alpha-MSH in ocular function, and suggest that the ocular response to alpha-MSH may be subject to inhibitory control by MIF-I.

Animals↗

Changes in pupillary dynamics in young men during prolonged severe exercise.

Infrared pupillography has been performed on 9 male cadets taking part in a combat course lasting for 5 days. The combat course involved lack of sleep, strong physical exercise and caloric deficit. During the course pupillary size was determined after rapid adaptation to darkness and the rate of concentration and the rate of dilatation after stimulation of the opposite eye with light was determined. Dilatation time increased by 50% towards the end of the course and pupillary size before light stimulation was reduced by 14%. On day 3 and 5, but not on day 1, small amplitude pupillary oscillations were observed. The speed of contraction was, however, unchanged.

Adult↗

Multiple dosing of prostaglandin F2 alpha or epinephrine on cynomolgus monkey eyes. I. Aqueous humor dynamics.

After obtaining baseline intraocular pressure (IOP) measurements for 1 week, prostaglandin (PG) F2 alpha (250 micrograms in 50 microliters saline) or epinephrine 2% solution (50 microliters) was topically applied twice daily for 2 weeks to one eye of six cynomolgus monkeys for each agent tested. Contralateral control eyes received their respective vehicles. PGF2 alpha significantly reduced IOP beginning 2 to 3 hr after the first dose, persisting thereafter. A significant (P less than 0.05) hypotensive effect remained for at least 10 hr after the first dose and at least 14 hr after the sixth dose. At 4 hr after the seventh dose, the mean reduction was 10.2 +/- 3.5 (+/- SD) mmHg below baseline (P less than 0.0025). At this time, there was also a significant (P less than 0.01) mean reduction of IOP in the contralateral vehicle-treated eyes of 6.0 +/- 3.3 (+/- SD) mmHg below baseline, which did not appear to be secondary to diurnal fluctuations, repeated tonometry, experimental manipulation, or inadvertent drug transfer. Epinephrine significantly (P less than 0.05) reduced IOP beginning 3 hr after the first dose, but this reduction was minimal and not consistent. Neither PGF2 alpha nor epinephrine altered aqueous flow as measured by fluorophotometry 2 to 6 hr after the fifth dose. Outflow facility could not be assessed by indentation tonography because IOP was often too low at the time of measurement. Whereas PGF2 alpha did not alter pupil size, epinephrine caused significant pupillary dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[Computer-assisted static and light-evoked dynamic pupillometry in psychosomatic patients].

Microprocessor-assisted pupillometry was used in this psychophysiological study to investigate the pupillary diameter (static pupillometry) and visual-evoked pupillary reactions (dynamic pupillometry) in psychosomatic patients (duodenal ulcers, ulcerative colitis, cardiac phobia, anorexia nervosa, bronchial asthma) as compared with age-and sex-matched normal controls. Statistical analyses including multivariate methods demonstrated interesting differences between psychosomatic patients and normal controls, as well as between various subtypes of psychosomatic disorders and elucidated also the influence of a 6 weeks' course of psychotherapy. The data give valuable clues to symptom/syndrome-specific psychophysiological reaction types, which may be of considerable relevance for the characterization of psychosomatic diseases.

Adolescent↗

Portable infrared pupillometry using Pupilscan: relation to somatic and autonomic nerve function in diabetes mellitus.

The relationship between dynamic pupillary function and peripheral nerve function was studied in 85 randomly-selected diabetic patients and 67 age-matched normals using a portable infrared pupillometer (Pupilscan Version 5). Seven measurements were chosen to represent different components of the pupillary constriction-redilatation curve after a standardized light stimulus. Constriction latency was significantly prolonged in diabetic patients (p = 0.05), as was time to 63% redilatation (p = 0.001). Thermal thresholds at the feet weakly correlated with relative reflex amplitude (warm: r = -0.22, p = 0.05; cool: r = -0.23, p = 0.05), but vibration perception thresholds were more strongly associated with constriction and redilatation velocity (r = -0.42, p = 0.001; r = -0.28, p = 0.03). Among the cardiovascular autonomic function tests, only respiratory R-R variation correlated with constriction velocity (r = 0.47, p < 0.001), and Valsalva ratio with redilatation velocity (r = 0.25, p = 0.04), but postural systolic blood pressure change was also correlated with reflex amplitude and latency time (r = -0.42, p < 0.001; r = 0.41, p = 0.001). There were no significant associations with three measures of sweating function in the feet. Pupil measurements were abnormal in 4-11% of diabetic patients, while other neurological tests were abnormal in 8-35%, consistent with the length-dependence of diabetic neuropathy. Median coefficients of variation were 2.0-7.2% in diabetic patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Efficacy of a pediatric cycloplegic administered as a spray.

BACKGROUND: The topical administration of eyedrops is often an unpleasant procedure in the pediatric population. We sought to learn whether a combination mydriatic-cycloplegic solution would be an effective cycloplegic if delivered as a spray. METHODS: We conducted a prospective, examiner-masked, parallel-group study and randomized 38 subjects (age range 6 months to 12 years, mean = 7.3 years) into four groups such that the same combination mydriatic-cycloplegic solution was administered under the following conditions: 1) eyedrops to eyes that were open; 2) eyedrops to eyes that were closed; 3) spray to eyes that were open; 4) spray to eyes that were closed. Both eyes of each subject received the solutions administered under one of the four conditions. Residual accommodation was measured using dynamic retinoscopy and the subjective push-up method, where applicable, at times 0, 10, 20, 30, 45, and 60 mins following administration of the medications. RESULTS: Repeated measures analysis of covariance revealed no statistically significant difference (p > 0.05) in cycloplegic efficacy among the four methods of drug delivery. CONCLUSIONS: The results of this study suggest that administering cycloplegics by spray to the closed eye is as efficacious as instilling eyedrops to the open eye. Use of a cycloplegic spray can have important clinical advantages compared to conventional cycloplegic eyedrops administered to children.

Accommodation, Ocular↗

Transpupillary laser phototherapy of tumors and vascular anomalies of retina and choroid: theoretical approach and clinical implications.

BACKGROUND: Small retinal and choroidal tumors situated near the optic nerve or macula, such as retinoblastomas and malignant melanomas, as well as various other anomalies, in particular vascular malformations, may successfully be treated by photocoagulation. Model assumptions geared towards maximizing efficiency and minimizing undesirable side effects are forwarded, and the most important parameters subserving photothermal destruction, such as radiation field and thermal energy, analyzed. The influence exerted by physical traits of various tissues involved are also considered. METHODS: The model approximations presented are based on classical radiation and absorption laws, as well as on the scattering properties of the various tissues implicated, these being considered as a function of wavelength and their relevance to the photodestructive task at hand. Particular attention is paid to the rate processes and reaction kinetics of irradiated proteins. CONCLUSIONS: Radiation sources emitting in the near-infrared range of the electromagnetic spectrum, such as the diode (810 nm) and the cw Nd:YAG (1064 nm) lasers, are optimal for the treatment of tumors and large, voluminous entities (such as Hippel-Lindau angiomas), owing to the good tissue penetration properties of their light. Those emitting in the shorter wavelength range, such as the argon ion (488 and 514 nm) and first harmonic--mode Nd:YAG (532 nm) lasers, are not suitable for such tasks, but they are ideal for the destruction of fine sanguinous structures, within which their light is strongly absorbed but through which it penetrates poorly. For the treatment of large anomalous structures, a combined short/long wavelength--strategy should also be considered as a viable alternative. Such a "wavelength mixture" is emitted by the xenon high pressure lamp of the once renowned Meyer-Schwickerath light coagulator. The precision and safety of photothermal destruction methods depend, in the first approximation, upon the details of the pulse energy deposition (wavelength, pulse height and duration, pulse dynamics, mode composition, focussing), the choice of which is determined by the optical and thermal constants of the irradiated tissues. Higher pulse energies will, of course, be more effective in destroying neoplastic cells, but the risk of producing undesired collateral heat damage will also increase concomitantly. Until we can ascertain the physical properties of the pathological tissues treated with certainty, we will hardly be able to achieve more than an approximation of an ideal treatment strategy. But with increasing developments in in vivo-diagnostic techniques, we expect that this goal will be attainable in the not too distant future.

Animals↗

Pharmacokinetic-dynamic study on different oral biperiden formulations in volunteers.

The pharmacodynamic and kinetic profiles of two oral biperiden formulations (tablet with instant-release and sugar-coated tablet with slow-release) were studied in a total of 12 healthy subjects after the administration of a 4 mg dose and compared in part to placebo. Biperiden as slow-release formulation showed much slower absorption than the instant-release tablet; whereas plasma levels peaked as early as 1-2 h after administration of the tablet, with the slow-release formulation a first peak was seen approximately 4.5 h after intake in the majority of the subjects. In some subjects this was followed by a trough, in others by formation of a shoulder at around 0.5 ng/ml. In all subjects a peak of about 1.0 ng/ml was reached after 10-12 h. The instant-release tablet and the slow-release formulation showed comparable bioavailability. Plasma concentrations for the slow-release formulation at 24 h were around 0.5 ng/ml, about twice as high as those for the instant-release formulation. The ratio of peak to 24 h values showed the marked reduction which is characteristic for a slow-release formulation compared with the instant-release tablet. The subjective well-being of the volunteers was not influenced by the slow-release formulation, whereas after the instant-release tablet slight CNS effects (dizziness, drowsiness and fatigue) were reported up to 6 h after ingestion. Furthermore, objectively quantifiable pharmacodynamic ocular parameters (near-point accomodation, pupil size) and the secretion of saliva proved to be less affected by the slow-release formulation than by the instant-release tablet, or not affected at all.

Accommodation, Ocular↗

Dynamics of the eye's wave aberration.

It is well known that the eye's optics exhibit temporal instability in the form of microfluctuations in focus; however, almost nothing is known of the temporal properties of the eye's other aberrations. We constructed a real-time Hartmann-Shack (HS) wave-front sensor to measure these dynamics at frequencies as high as 60 Hz. To reduce spatial inhomogeneities in the short-exposure HS images, we used a low-coherence source and a scanning system. HS images were collected on three normal subjects with natural and paralyzed accommodation. Average temporal power spectra were computed for the wave-front rms, the Seidel aberrations, and each of 32 Zernike coefficients. The results indicate the presence of fluctuations in all of the eye's aberration, not just defocus. Fluctuations in higher-order aberrations share similar spectra and bandwidths both within and between subjects, dropping at a rate of approximately 4 dB per octave in temporal frequency. The spectrum shape for higher-order aberrations is generally different from that for microfluctuations of accommodation. The origin of these measured fluctuations is not known, and both corneal/lenticular and retinal causes are considered. Under the assumption that they are purely corneal or lenticular, calculations suggest that a perfect adaptive optics system with a closed-loop bandwidth of 1-2 Hz could correct these aberrations well enough to achieve diffraction-limited imaging over a dilated pupil.

Accommodation, Ocular↗

Multiconjugate adaptive optics for large telescopes: analytical control of the mirror shapes.

We present an analytical algorithm for deriving the shapes of the deformable mirrors to be used for multiconjugate adaptive correction on a large telescope. The algorithm is optimal in the limit where the overlap of the wave-front contributions from relevant atmospheric layers probed by the guide stars is close to the size of the pupil. The fundamental principle for correction is based on a minimization of the sum of the residual power spectra of the phase fluctuations seen by the guide stars after correction. On the basis of the expressions for the mirror shapes, so-called layer transfer functions describing the distribution of the correction of a single atmospheric layer among the deformable mirrors and the resulting correction of that layer have been derived. It is shown that for five guide stars distributed in a regular cross, two- and three-mirror correction will be possible only up to a maximum frequency defined by the largest separation of the conjugate altitudes of the mirrors and by the angular separation of the guide stars. The performance of the algorithm is investigated in the K band by using a standard seven-layer atmosphere. We present results obtained for two guide-star configurations: a continuous distribution within a given angular radius and a five-star cross pattern with a given angular arm length. The wave-front fluctuations are subjected to correction using one, two, and three deformable mirrors. The needed mirror dynamic range is derived as required root-mean-square stroke and actuator pitch. Finally the performance is estimated in terms of the Strehl ratio obtained by the correction as a function of field angle. No noise has been included in the present analysis, and the guide stars are assumed to be at infinity.

Journal Article↗

Rationalizing early embryogenesis in the 1930s: Albert Dalcq on gradients and fields.

The present account aims to contribute to a better characterization of the state and the dynamics of embryological knowledge at the dawn of the molecular revolution in biology. In this study, Albert Dalcq (1893-1973) was chosen as a representative of a generation of embryologists who found themselves at the junction of two very different approaches to the study of life: the first, focusing on global properties of organisms; the first, focusing on the characterization of basic molecular constituents. Though clearly belonging to the organismic tradition, Dalcq was already blending his experimental and explanatory practices with biochemical aspects by the 1930s. Principally based on published sources, the present analysis focuses on the conceptual definitions, modifications and interrelations on which Dalcq's explanation of development rested. Among these are variant process concepts such as gradients and fields, which are often thought to have strongly holistic implications. I will argue that Dalcq's version of these concepts was compatible with a more reductionist treatment of embryos than was accepted by most embryologists as late as the 1950s, pointing to some extent toward the recent molecular characterization of gradients by molecular geneticists such as Christiane Nüsslien-Volhard. Moreover, I will show the embryological research program of Dalcq and his pupil Jean Brachet has been largely instrumental in the development of molecular biology in Belgium.

Belgium↗

[An outbreak of scarlet fever, impetigo and pharyngitis caused by the same Streptococcus pyogenes type T4M4 in a primary school].

UNLABELLED: EPIDEMIC: Following the notification of an unusual number of scarlet fever cases within the same primary school, the epidemiological and clinical features of the outbreak were investigated. Questionnaire information about the cases was collected from parents and general practitioners per telephone. Throat specimens were taken, before and after treatment, for culturing and specific typing of streptococci was performed to determine transmission. Within a period of one month, 21 schoolchildren in a class of 29 pupils, with a mean age of 5 years, presented with symptoms caused by streptococcal infection (attack rate: 72%). Eight had scarlet fever, 5 suffered from impetigo and 8 had pharyngitis. A further 6 children, outside of this class, had complaints of scarlet fever, impetigo or pharyngitis. For 90% (26/29) of the schoolchildren a throat culture was established. Twelve positive cultures of the same strain of beta-haemolytic group A streptococcus, T4M4 exotoxin C gene positive, were found. The advice given was to treat all positive children for 3 days with azithromycin to prevent complications and further spreading of the disease. After two weeks only one child, that had not taken the antibiotics, still had a positive throat culture. No further cases or complications were reported. DISCUSSION: The pattern of the outbreak was typical of a person-to-person transmission. This was confirmed by typing of the isolates. The results of this study demonstrate the importance of mandatory notification of infectious clusters by institutions, such as schools, as introduced in the new Dutch Infectious Disease Act. On the one hand, the notification gives the municipal health authority the opportunity to analyse source and transmission dynamics and on the other to prevent disease and complications.

Bacterial Typing Techniques↗