PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Respiratory Protective Devices”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Intervention research in construction: a hypothetical case study of painters.

This paper presents a theory on which to base intervention research in the construction industry, along with a hypothetical case study involving construction painters. The hypothetical case is based on data from research in a three-state study of construction painters currently under way. Difficulties facing researchers who conduct research in construction are described. Advantages of the intervention research design for construction are discussed.

Construction Materials↗

Respiratory health services reported by U.S. mining facilities in the National Occupational Health Survey of Mining (1984-1989).

This report describes the involvement of mine management personnel at U.S. mines in providing environmental and medical services related to respiratory health. The data were obtained by means of a questionnaire that was administered to mine management personnel at 491 mines and mills during May 1984 to August 1989. The data indicate that 62% of U.S. miners worked at facilities that provided at least a portion of workers with chest X-rays, and 41% worked at facilities that provided at least a portion of workers with pulmonary function tests. Eighty-five percent of miners worked at facilities in which the company required a medical examination of all new employees; the majority were required by company policy to have a medical examination before returning to work after an illness. However, only 2% of miners were required by company policy to have an exit medical examination when their employment ended. This report underscores the need for respiratory health to remain a primary concern of all persons who provide occupational health services to miners.

Environmental Monitoring↗

Effect of protective filters on fire fighter respiratory health during simulated bushfire smoke exposure.

BACKGROUND: Bushfire fighters are potentially subject to risks from bushfire smoke. Although many different protective masks and filters are available, it is not clear which is the most effective from a health and safety perspective. The effect of protective filters on the respiratory health of Western Australian urban career fire fighters under controlled simulated conditions is investigated. METHODS: Sixty-four healthy Fire and Emergency Services Authority of Western Australia (FESA) urban career fire fighters were subjected to controlled simulated bushfire smoke in an open smoke chamber for 15 min. The fire fighters were allocated one of the three types of protective filters: particulate only (P), particulate/organic vapor (POV), and a particulate/organic vapor/formaldehyde (POVF) filter using a double-blind randomized procedure. Personal air sampling inside the fire fighters' masks, spirometry, oximetry, and self-reported symptom data were collected at baseline and at two time intervals after the smoke exposure. RESULTS: A significant decline in oxygen saturation was seen immediately after exposure, however, the decline was small and no significant relationships could be established between this and the type of filter used. A significantly higher number of participants in the P and POV filter groups self-reported an increase in coughing, wheezing, and shortness of breath compared to the POVF group. Air sampling demonstrated a significantly higher level of formaldehyde and acrolein inside the masks fitted with P filters compared to POV and POVF filters. CONCLUSIONS: Testing the effectiveness of P, POV, and POVF filters under controlled conditions has demonstrated that the POVF filter provides statistically significant better protection for the fire fighters' airways in a simulated bushfire exposure chamber.

Adult↗

A longitudinal study of pulmonary function in fire fighters.

Pulmonary function changes among fire fighters were evaluated by re-examining 632 Baltimore city fire fighters six to ten years after a baseline examination. Spirometry was used to determine forced expiratory volume in 1 second (FEV1). Information about exposures was obtained by questionnaire and by combining data from fire department records regarding the number of fires fought by fire fighting units with individual work histories. Men who never wore a mask while extinguishing fires experienced a 1.7 times greater rate of FEV1 decline than mask wearers. Men with ammonia exposure experienced a rate of decline 1.7 times greater than non-exposed men. Neither length of time spent in exposed jobs nor number of responses were associated with the rate of decline. Active fire fighters experienced a rate of decline 2.5 times greater than those who had retired or resigned. Some effects differed between men who were able to perform repeatable pulmonary function tests and those who were not.

Adult↗

Evaluation of skin and respiratory doses and urinary excretion of alkylphosphates in workers exposed to dimethoate during treatment of olive trees.

This article describes a study of exposure to dimethoate during spraying of olive trees in Viterbo province in central Italy. Airborne concentrations of dimethoate were in the range 1.5 to 56.7 nmol/m(3). Total skin contamination was in the range 228.4 to 3200.7 nmol/d and averaged 96.0% +/- 3.6% of the total potential dose. Cotton garments afforded less skin protection than waterproof ones, which were in turn associated with higher skin contamination than disposable Tyvek overalls. Total potential doses and estimated absorbed doses, including their maxima, were below the acceptable daily intake of dimethoate, which is 43.6 nmol/kg body weight (b.w.). Urinary excretion of alkylphosphates was significantly higher than in the general population, increasing with exposure and usually showing a peak in the urine sample collected after treatment. Metabolite concentrations were influenced by the type of individual protection used: minimum levels were associated with the closed cabin and maximum levels with absence of any respiratory or hand protection. Urinary alkylphosphates showed a good correlation with estimated absorbed doses and are confirmed as sensitive biologic indicators of exposure to phosphoric esters.

Adult↗

The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airway.

The fear of acquiring infectious diseases has resulted in reluctance among healthcare professionals and the lay public to perform mouth-to-mouth ventilation. However, the benefit of basic life support for a patient in cardiopulmonary or respiratory arrest greatly outweighs the risk for secondary infection in the rescuer or the patient. The distribution of ventilation volume between lungs and stomach in the unprotected airway depends on patient variables such as lower oesophageal sphincter pressure, airway resistance and respiratory system compliance, and the technique applied while performing basic or advanced airway support, such as head position, inflation flow rate and time, which determine upper airway pressure. The combination of these variables determines gas distribution between the lungs and the oesophagus and subsequently, the stomach. During bag-valve-mask ventilation of patients in respiratory or cardiac arrest with oxygen supplementation (> or = 40% oxygen), a tidal volume of 6-7 ml kg(-1) ( approximately 500 ml) given over 1-2 s until the chest rises is recommended. For bag-valve-mask ventilation with room-air, a tidal volume of 10 ml kg(-1) (700-1000 ml) in an adult given over 2 s until the chest rises clearly is recommended. During mouth-to-mouth ventilation, a breath over 2 s sufficient to make the chest rise clearly (a tidal volume of approximately 10 ml kg(-1) approximately 700-1000 ml in an adult) is recommended.

History, Ancient↗

[The centennial of oxygen-therapy (1902 - 2002) -- reassessing its history. Part II: The contributions of the "Roth-Draeger anaesthesia apparatus" (1902) and other inventions of 100 years of Draeger-Medical-Technology (1902-2002) to the history of truly "therapeutic" application of oxygen].

This is the second part of a survey which analyses the history of inhalative oxygen therapy and its interactions with the history of anaesthesiology. Specific emphasis is put here on illustrating inventions of modern pressure gas technology such as pressure reducing valves. These enabled Draeger Inc. to be the first firm to develop and trade on a large scale technically convincing products allowing a rational, therapeutic application of oxygen. Especially Draeger anaesthesia apparatus (e. g. the "Roth-Draeger Anaesthesia Apparatus") and respiratory protective devices, which were available from 1902, proved also internationally successful from the very beginning. In the international historiography on inhalative oxygen therapy, however, these contributions have to our knowledge so far never been systematically considered. Consequently, J. S. Haldane (1860 - 1936) is regarded there to have "founded" of modern oxygen therapy in 1917. Critically reviewing this earlier research, we propose a historical reassessment, concluding that the year 1902 was the historically decisive "turning point" towards the development of modern oxygen therapy.

Anesthesiology↗

Prevalence of antibodies to Legionella pneumophila among workers exposed to a contaminated cooling tower.

A serosurvey for antibodies to Legionella pneumophila was conducted among 206 employees of a power-generating plant. L. pneumophila serotype 6 and a non-typable L. pneumophila organism were isolated from cooling-tower water specimens at the plant, and antibody titers in workers were measured using homologous antigens prepared from these isolates. For the serotype 6 water isolate, none of workers with low cooling tower exposure, 4.6% with intermediate exposure, and 7.6% with high exposure levels had titers equal to or greater than 1:128 (P less than .05, Kruskal-Wallis test). For the non-typable L. pneumophila isolate, a similar trend was observed, but differences among workers in the three exposure groups were not statistically significant. No association was observed between antibodies to L. pneumophila serotypes isolated from cooling water and workers' age, race, smoking status, or duration of job assignment. None of the study employees had findings suggesting the occurrence of L. pneumophila pneumonia since the plant had been in operation. Use of respiratory protection devices by workers exposed to aerosols from cooling towers was not recommended.

Adult↗

Air contaminants encountered by firefighters.

The concentrations of eight air contaminants suspected of causing acute and chronic health problems for firefighters were measured in over 200 fires in the City of Boston using a personal air sampler. Threatening concentrations of both carbon monoxide and acrolein were found in a small proportion of the fires. Less hazardous levels of hydrogen chloride, hydrogen cyanide, nitrogen dioxide and carbon dioxide were also noted. Benzene was found in most fires, but at concentrations well below those expected to cause acute injury. The air sampling data have application in treatment of smoke inhalation victims, development of firefighting strategies and selection of respiratory protection devices.

Air Pollutants↗

Particle concentration in exhaled breath.

Measurements were made of the number concentrations of particles in exhaled breath under various conditions of exercise. A laser light scattering particle spectrometer was used to count particles exhaled by test subjects wearing respirators in a challenge environment of clean, dry air. Precautions were taken to ensure that particles were not generated by the the respirators and that no extraneous water or other particles were produced in the humid exhaled air. The number of particles detected in exhaled air varied over a range from less than 0.1 to about 4 particles per cm3 depending upon the test subject and his activity. Subjects at rest exhaled the lowest concentration of particles, whereas exercises producing a faster respiration rate caused increased exhalation of particles. Exhaled particle concentrations can limit the usefulness of nondiscriminating, ambient challenge aerosols for the fit testing of highly protective respirators.

Aerosols↗

Quantitative respirator fit testing: dynamic pressure versus aerosol measurement.

A noninvasive, fast, inexpensive new fit testing method has been invented which relates the slope of the pressure decay inside a respirator during breath-holding to the fit of the respirator on the wearer's face. The dynamic pressure test has been compared with the conventional aerosol test at different leakage levels. The results of this comparison show that the sensitivity of the dynamic pressure test is similar to that of the aerosol test. The pressure test, however, is independent of leak site and probe location and can be performed on respirators before and after their use.

Aerosols↗

Usefulness of pulsed-field gel electrophoresis in assessing nosocomial transmission of pertussis.

During a 2-week period, three infants with a cough lasting at least 8 days with whoops, were admitted to the pediatric unit; Bordetella pertussis was isolated from nasopharyngeal aspirates collected from the three infants. Approximately 1 week later, a nurse working on the same unit developed influenza-like symptoms followed by whooping cough; B pertussis was isolated. Isolates from the nurse and from one of the infants were shown to be indistinguishable by pulsed-field gel electrophoresis. These data demonstrate that B pertussis transmission to healthcare workers is possible and emphasize the need to use respiratory protection devices (Droplet Precautions) for healthcare workers having close contact with infected children.

Adult↗

Prevention of nosocomial transmission of respiratory syncytial virus in a newborn nursery.

During three winter seasons prior to 1984-1985 the special care nursery at New England Medical Center experienced respiratory syncytial virus (RSV) epidemics that required closure of the unit. Prior to and during the 1984-1985 winter season, several measures were taken to prevent recurrent nosocomial RSV transmission. In the winters of 1984-1985 and 1985-1986 there were 26 introductions of community-acquired RSV with no transmission of nosocomial cases during 1,688 patient days at risk as compared with 1983-1984 when there were seven cases of nosocomial RSV following six introductions of RSV during 875 patient days at risk (rate = 8 per 1,000 patient days) (P = 0.0016). The institution of many infection control measures including active surveillance, cohorting infected patients, a strict winter visiting policy, and gowning, gloving, and applying mask on contact, was associated with the successful prevention of nosocomial transmission of RSV in this nursery setting.

Boston↗