PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

The use of solid-phase microextraction--gas chromatography in forensic analysis.

A thorough review of the application of solid-phase microextraction (SPME) combined with gas chromatography for the analysis of forensic specimens is presented, including experimental results for several recent applications. The SPME applications covered in this comprehensive review include ignitable liquid residues (also referred to as accelerants), explosive traces, drugs and poisons from biological specimens, and other forensic applications. Recently developed SPME methods are also presented, including the analysis of ignitable liquid residues on human skin, odor signatures, and several drug applications such as free-fraction antipsychotic drug levels, blood alcohol casework, drink-tampering analysis, and gamma-hydroxybutyrate identification without the need for derivatization. SPME is shown to be an inexpensive, rapid, and sensitive method for the analysis of a variety of forensic specimens.

Blood Chemical Analysis↗

[Solid-phase microextraction of dichlorvos from white spirits].

DDVP was isolated from white spirits using Solid-Phase Microextraction (SPME) technique, and determined by wide-bore capillary gas chromatography (GC) coupling a flame ionization detector. This method had an excellent linearity among 0.5-12 mg/L. Correlation coefficient and minimum detectable concentration were 0.9983 and 0.05 mg/L respectively. This method enables the extraction, the enrichment and the injection to integrate into a single step, and it was free-solvent in whole process. SPME is an advanced technique for the extraction and analysis of the samples.

Alcoholic Beverages↗

In vivo sampling with solid phase microextraction.

This review discusses the most recent developments and future challenges in the application of solid phase microextraction (SPME) for sampling of live biological samples. The emphasis is placed on applications of fiber SPME for analysis of volatile emissions and drugs in biological fluids. The method development section highlights the main parameters that need to be considered in the case of in vivo experiments: extraction techniques, selection of extraction phases, calibration procedures, determination of free concentrations, and automation.

Drug Evaluation, Preclinical↗

Solid-phase microextraction for the analysis of short-chain chlorinated paraffins in water samples.

A novel solid-phase microextraction (SPME) method coupled to gas chromatography with electron capture detection (GC-ECD) was developed as an alternative to liquid-liquid and solid-phase extraction for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples. The extraction efficiency of five different commercially available fibres was evaluated and the 100-microm polydimethylsiloxane coating was the most suitable for the absorption of the SCCPs. Optimisation of several SPME parameters, such as extraction time and temperature, ionic strength and desorption time, was performed. Quality parameters were established using Milli-Q, tap water and river water. Linearity ranged between 0.06 and 6 microg l(-1) for spiked Milli-Q water and between 0.6 and 6 microg l(-1) for natural waters. The precision of the SPME-GC-ECD method for the three aqueous matrices was similar and gave relative standard deviations (RSD) between 12 and 14%. The limit of detection (LOD) was 0.02 microg l(-1) for Milli-Q water and 0.3 microg l(-1) for both tap water and river water. The optimised SPME-GC-ECD method was successfully applied to the determination of SCCPs in river water samples.

Chromatography, Gas↗

Application of solid-phase microextraction in the monitoring of priority pesticides in the Kalamas River (N.W. Greece).

A solid-phase microextraction (SPME) method was applied to an extended monitoring survey of priority pesticides for the European Union for a period of 12 months in water of the Kalamas River (Epirus region of northwestern Greece) in order to determine their concentrations and seasonal variations. Polydimethylsiloxane-coated fiber (100 microm) was used. The samples were screened using gas chromatography with flame thermionic detection. Detection was confirmed by gas chromatographymass spectroscopy. The most frequently detected pesticides were some of the more commonly used herbicides, such as S-ethyl-N,N-di-n-propylthiol carbamate (EPTC), trifluralin, atrazine, deethylatrazine, terbuthylazine and alachlor, and insecticides, such as carbofuran, diazinon, disulfoton, parathion methyl, parathion ethyl, fenthion and ethion. Concentrations of individual compounds ranged from 0.020 to 0.3 microg/L. Greater pesticide concentrations occurred during the seasons of application. A comparison with a well-established solid-phase extraction (C18 disks) procedure was performed for samples of high-season application (May-September) in order to confirm the effectiveness of the SPME technique. The results demonstrate the suitability of the SPME method for routine screening multiresidue analysis in natural waters.

Chromatography, Gas↗

Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

Antidepressive Agents, Second-Generation↗

Determination of fluoride in toothpaste using headspace solid-phase microextraction and gas chromatography-flame ionization detection.

A new method for determination of fluoride in toothpaste employing the headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/flame ionization detection (GC/FID) has been proposed. It is a development of the method for determination of fluoride using trimethylchlorosilane (TMCS) as the derivatization reagent to form trimethylfluorosilane (TMFS), with the liquid/liquid extraction (LLE) step replaced by HS-SPME. To introduce the latter, it was necessary to determine the conditions of the reaction and to optimize the two stages of the SPME procedure: extraction and desorption. The parameters of the SPME analysis using carboxen/polydimethylsiloxane (CAR/PDMS) fiber were defined and compared with the corresponding ones for the LLE method, used as a reference. Also, these two methods were compared with respect to their linearity, precision, and accuracy. Results from toothpaste analyses using these two methods were highly correlated, indicating the potential to use the SPME extraction as an inexpensive and solventfree alternative to the LLE method.

Chromatography, Gas↗

Application of solid phase microextraction for the determination of soil fumigants in water and soil samples.

The potential of solid phase microextraction (SPME) for the determination of the soil fumigants 1,3-dichloropropene (1,3-DCP) and methyl isothiocyanate (MITC) in environmental samples such as soil and water samples has been investigated. Direct immersion SPME followed by GC/ECD/NPD analysis allowed the rapid determination of the two fumigants in water samples, with very little sample manipulation, giving an LOD of 0.5 microg L(-1). Precision, calculated as relative standard deviation (RSD) for six replicates at three concentration levels, was found to be lower than 20% at the concentration levels tested. For the analysis of soil samples, headspace (HS)-SPME combined with GC/ECD/NPD analysis has been applied. Quantification using matrix-matched calibration curves allowed determination of both analytes (MITC and 1-3-DCP) with a LOD of 0.1 microg kg(-1) (RSD < 10%) for the two concentration levels assayed (0.02 and 0.2 mg kg(-1)). The HS-SPME procedure developed in this paper was applied to soil samples from experimental green house plots treated with metham-Na, a soil disinfestation agent that decomposes in soil to MITC. The absence of sample manipulation as well as the low solvent consumption in SPME methodology are among the main advantages of this analytical approach.

Journal Article↗

Applications of solid phase microextraction for the determination of metallic and organometallic species.

This paper reviews recent developments of solid phase microextraction (SPME) and its application to the analysis of organometallic species of lead, arsenic, mercury, tin, and selenium by hyphenation with HPLC-GC-atomic spectrometry. In the first part, a background of the technique is given in terms of derivatization, fibers used, extraction and desorption conditions. The second part summarizes typical SPME applications to the determination of organometallic species and the main experimental conditions with the aid of specific examples. Most of the applications comprise alkylation with NaBEt4 and headspace extraction followed by gas chromatographic separation with a suitable detector.

Journal Article↗

Comparison of two quantitative GC-MS methods for analysis of tomato aroma based on purge-and-trap and on solid-phase microextraction.

Two analytical procedures, one based on purge-and-trap and the other on solid phase microextraction, both followed by GC-MS measurement using an ion-trap mass spectrometer in the electron impact mode, have been developed for determination and quantitation of up to 39 aroma compounds in fresh tomatoes. The method based on purge-and-trap for isolation of the volatile compounds uses Tenax as adsorbent and a hexane-diethyl ether mixture as solvent for elution. The method was validated for linearity, precision (better than 20% for most compounds), and limit of detection, which was approximately 1 ng g(-1). This method enabled identification of up to 30 compounds in real samples. Use of SPME was considered as an alternative, to simplify sample treatment while maintaining the information level for the samples (e.g. the number of compounds detected) and quality of quantitation. A procedure based on SPME using a Carboxen/polydimethylsiloxane fibre was developed and validated for determination of 29 aroma compounds; precision was better than 20% and limits of detection ranged from 4 to 30 ng g(-1).

Gas Chromatography-Mass Spectrometry↗

Sampling and analysis of polychlorinated biphenyls in indoor air by sorbent enrichment followed by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) techniques has been used to determine polychlorinated biphenyls (PCBs) in air. Using a vacuum pump, a known volume of air was pulled through a porous polymer (Tenax TA) where the target analytes were retained and then headspace SPME was carried out. The quantification was performed using gas chromatography coupled to tandem mass spectrometry. Certain factors, such as temperature and the addition of solvents to the adsorbent, were found to be very important for the transfer of the target PCBs from the Tenax to the SPME fiber. Some of these factors were studied using an experimental design strategy. Performance of the method was evaluated demonstrating that external calibration, which does not require performing the complete sampling process, was suitable. The coefficients of determination were calculated and a lack-of-fit test was run within the calibration data, demonstrating linearity of the method. Repeatability was found adequate (RSD < or = 12%). Limits of detection (LODs) were found below 0.100 ng/m3 when only 2.5 m3 air were sampled. These LODs were low enough to check for harmful levels of PCBs in indoor air, and are well below the most restrictive limits established by countries regulations. In addition, more sensitivity could be attained by increasing the volume of air sampled (decrease in retention efficiency was not detected for sample volumes up to 25 m3), and/or extending the extraction time in the SPME step.

Air Pollution, Indoor↗

Depletion solid-phase microextraction for the evaluation of fiber-sample partition coefficients of pesticides.

A depletion solid-phase microextraction (SPME) method for the characterisation of SPME sorption for 13 pesticides selected as probe compounds is described. The sample is extracted and analysed multiple times by SPME-GC/MS. The observed depletion in peak areas is used for the calculation of extraction ratios that varied between 3 and 28% for a PDMS fiber with confidence intervals between 0.7 and 5.4%. Apparent fiber-sample partition coefficients can be calculated and extrapolated to equilibrium conditions if specific sorption kinetics are known. Under the chosen conditions, problems were encountered for more polar compounds (logK(ow)<3) due to inefficient extraction. The extracted amount was found to be the decisive parameter for depletion SPME and the extraction conditions therefore need to be adapted to the polarity of the analyte. The importance of the initial analyte concentration especially for mixed-mode fibers is demonstrated. Compared with conventional external calibration using liquid injection, depletion SPME eliminates uncertainties due to solvent effects during injection. Furthermore, it does neither require authentic reference compounds nor knowledge of the initial analyte concentration, and thus can even be used for unknowns.

Adsorption↗

Automated determination of ethyl carbamate in stone-fruit spirits using headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

A fully automated procedure using headspace solid-phase microextraction (HS-SPME) followed by gas chromatographic/tandem mass spectrometric (GC/MS/MS) detection was developed for the determination of the toxic contaminant ethyl carbamate (EC) in stone-fruit spirits. After addition of deuterated internal standard, the optimised HS-SPME extraction with carbowax/divinylbenzene fibres (30 min at 70 degrees C) was done applying salting out with sodium chloride in the presence of pH 7 buffer solution. For quantitative analysis the characteristic fragmentations of m/z 74>44 and m/z 62>44 for ethyl carbamate as well as m/z 64>44 for ethyl carbamate-d5 were monitored in the multiple reaction monitoring (MRM) mode using a triple quadrupole instrument. In the validation studies, ethyl carbamate exhibited good linearity with a regression coefficient of 0.998. The limits of detection and quantitation were 0.03 and 0.11 mg/l. The precision never exceeded 4.3% (intraday) and 8.2% (interday) at any of the concentrations examined. A good agreement of analysis results in comparison to conventional sample clean-up over diatomaceous earth columns was found (R = 0.956, Bias = 0.08 mg/l). The new HS-SPME/GC/MS/MS procedure is suitable for the fast, reliable and inexpensive determination of ethyl carbamate in alcoholic beverages in an automated, and therefore, convenient procedure.

Alcoholic Beverages↗

Application of solid phase microextraction to the determination of strychnine in blood.

A simple and rapid method based on solid phase microextraction (SPME) via direct immersion followed by gas chromatography coupled with electron impact ionization/mass spectrometry (GC/EI-MS) was developed for the determination of strychnine in blood. Papaverine was used as internal standard (I.S.). Two types of fibre coating were tested, 100 microm polydimethylsiloxane and 65 microm Carbowax/Divinylbenzene, the latter giving higher recoveries of the compound. The main factors affecting the SPME process, such as sample dilution (1:10), adsorption and desorption times (20 and 10 min, respectively), carry-over effect (not observed), pH and salt addition (no modifications on pH or salt concentration) were optimized. The procedure was validated in terms of linearity (r(2)=0.9992 for concentrations ranging from 0.10 to 5.00 microg/mL), intra and interday precision (0.93 and 4.62%, respectively at 0.50 microg/mL; 3.33 and 8.06%, respectively at 2.50 microg/mL), sensitivity (6.83 and 8.91 ng/mL for LOD and LOQ, respectively) and extraction recovery (0.54 and 0.39% at 0.50 and 2.50 microg/mL, respectively). The developed procedure was found suitable for forensic investigations and was considered a good alternative to the liquid-liquid extraction methods normally used for the determination of this compound in biological media.

Adsorption↗

Determination of quinalphos in blood and urine by direct solid-phase microextraction combined with gas chromatography-mass spectrometry.

A new method based on direct solid-phase microextraction (DI-SPME) followed by gas chromatography-mass spectrometry was developed for the purpose of determining quinalphos in blood and urine. Two types of coated fibre have been assayed and compared: carbowax/divinylbenzene (CW/DVB 65 microm) and polydimethylsiloxane (PDMS 100 microm). The main parameters affecting the SPME process such as temperature, salt addition, pH, stirring and adsorption/desorption time profiles were optimized to enhance the sensitivity of the procedure. The method was developed using only 100 microL of blood and urine. Limits of detection of the method for blood and urine matrices were, respectively, 10 and 2 ng/mL. Linearity was established over concentration ranges from 0.05 to 50 microg/mL for blood, and 0.01 to 50 microg/mL for urine, with regression coefficients ranging between 0.9991 and 0.9999. Intra- and interday precision values were less than 13%, and accuracy was within +/-15% of the nominal concentration for all studied levels in both matrices. Absolute recoveries were 14 and 26% for blood and urine, respectively.

Adsorption↗

Analysis of low-volatility organic sulphur compounds in wines by solid-phase microextraction and gas chromatography.

A method for analysing low-volatility sulphur compounds using solid-phase microextraction has been developed. The analytes were extracted directly from the liquid sample using fibres coated with different stationary phases. The best extraction efficiency was obtained with Carboxen-polydimethylsiloxane coating. Ionic strength, sample volume, time and temperature of the extraction were optimised and the matrix effect studied. The method enables 15 sulphur compounds in wine to be determined at trace levels with recoveries close to 100% and limits of detection between 0.05 and 5 microg/L. The overall method was successfully applied to the determination of the sulphur compounds studied in several red, white and rosé wines.

Chromatography, Gas↗

Comparison of simultaneous distillation extraction and solid-phase microextraction for the determination of volatile flavor components.

Traditional simultaneous distillation extraction (SDE) and solid-phase microextraction (SPME) techniques were compared for their effectiveness in the extraction of volatile flavor compounds from various mustard paste samples. Each method was used to evaluate the responses of some analytes from real samples and calibration standards in order to provide sensitivity comparisons between the two techniques. Experimental results showed traditional SDE lacked the sensitivity needed to evaluate certain flavor volatiles, such as 1,2-propanediol. Dramatic improvements in the extraction ability of the SPME fibers over the traditional SDE method were noted. Different SPME fibers were investigated to determine the selectivity of the various fibers to the different flavor compounds present in the mustard paste samples. Parameters that might affect the SPME, such as the duration of absorption and desorption, temperature of extraction, and the polarity and structure of the fiber were investigated. Of the various fibers investigated, the PDMS-DVB fiber proved to be the most desirable for these analytes.

Chromatography, Liquid↗

Determination of volatile alkyl sulfides in wastewater by headspace solid-phase microextraction followed by gas chromatography-mass spectrometry.

An analytical procedure based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to mass spectrometry in the electron impact mode has been developed for the determination of low-molecular-mass sulfides and disulfides in wastewater. Parameters affecting to the extraction of these volatile alkyl sulfides (VASs) with the SPME, such as the extraction temperature, sample volume, pH and the NaCl addition to the matrix, have been optimised using a polydimethylsiloxane-Carboxen fibre. The linear dynamic range was close to three orders of magnitude for all the studied compounds. Detection limits of 4 ng l(-1) for dimethyl sulfide, 0.7 ng l(-1) for ethylmethyl sulfide, 5 ng l(-1) for diethyl sulfide and 1 ng l(-1) for dimethyl disulfide were achieved, with a relative standard deviation between 4 and 6%. The developed analytical methodology was applied to determine those VASs in different wastewaters.

Gas Chromatography-Mass Spectrometry↗