PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spirometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Changes in spirometry during consecutive admissions for infective pulmonary exacerbations in adolescent and adult cystic fibrosis.

Changes in spirometry during consecutive admissions for treatment of pulmonary infective exacerbations were studied in 45 patients (24 males, 21 females) with cystic fibrosis (CF) who had required five or more such admissions. Over the overall study period there was a mean (SD) decline in FEV1 of -112.1 (188.0) ml yr-1 (P less than 0.001) and in FVC of -47.9 (82.4) ml yr-1 (P less than 0.001). FEV1 and FVC increased during each admission with treatment; however, the magnitude of this change became less over consecutive admissions by a mean value of -33.3 ml (45.0) (P less than 0.001) for FEV1, and -26.0 (72.2) ml (P less than 0.05) for FVC. In the majority of patients that died or underwent transplantation, FEV1 at the time of the last admission did not rise above 800 ml despite full treatment.

Adolescent↗

Spirometry in life-long non-smoking, healthy Chinese women in Taiwan.

To establish the spirometric values for normal, healthy Chinese women in Taiwan, the spirometry of 506 life-long non-smoking, healthy Chinese women was examined, including 140 subjects over the age of 60 years. Significant correlations among age, height and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC%, peak expiratory flow (PEF), Vmax75, Vmax50, Vmax25 were found. However, there were no significant correlations between age and FEV1/FVC%, nor age and Vmax25 in the elderly group. FEV1 (FEV1*) and FVC (FVC*) were standardized to the overall mean height for elderly women using Cole's formula. The decline in FEV1* and FVC* with age were observed. The predicted value for the average 70-year-old woman with a height of 1.5 m derived from the present study is compared with those from other surveys of the elderly. The values from the present study are somewhat higher than the values from the Hong Kong study. The authors believe the fact that all of the present subjects were life-long non-smokers might explain the differences.

Adult↗

Assessment of respiratory function: influence of spirometry reference values and normality criteria selection.

The purpose of this study was to determine the impact upon classification of patients of the choice of reference equation and the criterion defining the lower limit of the normal range in clinical practice. One thousand consecutive spirometries were checked to calculate the predicted values [forced vital capacity (FVC) and forced expiratory volume in sec (FEV1)] in accordance with the equations by Morris, Cherniack, Crapo, Knudson and the Economic Community for Coal and Steel (ECCS). We quantified the difference between the predicted values obtained for each individual and each equation, determined the percentage of individuals whose classification might have changed from normal to abnormal when using a different equation and defined the lower limit of the normal range in accordance with the determination of 1. the 90% confidence interval or 2. 80% of predicted, comparing their differences. The greatest differences found were between the values given by Morris and Crapo's equations for male FEV1, between Morris and Cherniak for female FEV1 and male FVC and between Morris and Knudson for female FVC. Using 80% of predicted value for female FEV1, up to 35% of tests changed their classification from 'normal' to 'abnormal' upon changing the equation used. A high percentage of tests showed a lower limit of normal defined by the confidence interval under 80% and 70% of predicted value. This study emphasizes the importance of choosing the appropriate reference equation. We do not consider it acceptable to use a fixed percentage of the predicted value as the lower limit of normal because of the great number of patients found to be inappropriately classified.

Adolescent↗

[Spirometry at home: technology within the patient's reach].

Spirometry is a basic lung function test useful both for measuring and for monitoring expiratory volume. For many years monitoring has been performed by means of a portable peak flow meter capable of measuring maximal expiratory flow. We present a portable spirometer (Spirotel, Medical International Research, Rome, Italy) capable of transmitting stored lung function data from the patient's home by telephone. The device is easy to use, presents information graphically and numerically, and allows degrees of change in lung function to be monitored on-line. It may be useful for controlling asthma and work-related respiratory diseases.

Adult↗

[Spirometry is a good method for detecting and monitoring chronic obstructive pulmonary disease in high-risk smokers in primary health care].

OBJECTIVE: Chronic obstructive pulmonary disease (COPD) is a common disease, the early diagnosis of which allows effective management and treatment. The aim of the present study is to show the effectiveness of a screening and monitoring plan for COPD in high-risk patients in primary health care. PATIENTS AND METHODS: The subjects in this prospective observational longitudinal study comprised 164 high-risk smokers aged between 40 and 76 years. Age, sex, weight, height, and smoking habit (pack-years) were recorded and spirometry was performed according to the guidelines of the Spanish Society of Pulmonology and Thoracic Surgery (SEPAR). Patients were informed of their results and given brief advice on how to stop smoking. After 3 years, the patients underwent the same evaluation. RESULTS: In 1999, 22% of the smokers were diagnosed with COPD. Three years later, an additional 16.3% were diagnosed as having COPD, and the disease had worsened in 38.8% of those already diagnosed. Of the patients with a forced expiratory volume in one second (FEV1) less than 90%, 44.8% developed COPD (relative risk: 10.54). An accelerated decrease in FEV1 was found in 18.1% of the patients (20.7% with COPD and 9.0% without COPD). Mean tobacco consumption in 1999 was 28.1 pack-years in subjects without COPD and 31.7 pack-years in those with COPD, whereas in 2002, consumption was 30.6 pack-years in patients with COPD and 31.9 pack-years in those without. In 3 years, 22.8% had stopped smoking (20.5% without COPD and 30.3% with COPD). CONCLUSIONS: Many smokers managed to give up smoking after learning their spirometric results. FEV1 can identify smokers at greatest risk of developing COPD. Spirometric screening and monitoring of smokers at high risk in primary health care can identify those most susceptible to developing COPD while the disease is in an early phase. Therefore the most appropriate strategy can be adopted for each patient.

Adult↗

[Cystic fibrosis in adults: inter- and intraobserver agreement for the Brasfield and Chrispin-Norman chest radiography scoring systems and correlation with clinical data and spirometry].

OBJECTIVE: Most chest radiography scoring systems for patients with cystic fibrosis have been developed for children but are also used for adults. Our aim was to evaluate the intra- and interobserver variability of 2 radiographic scoring systems in adults with cystic fibrosis and to assess the correlation of these systems with clinical and spirometric parameters. PATIENTS AND METHODS: The chest x-rays of 24 adult patients with cystic fibrosis were compared using 2 scoring systems (Brasfield and Chrispin-Norman). The x-rays were scored by 2 radiologists and reevaluated 4 months later by 1 of the 2 observers. Intra- and interobserver agreement was assessed using the intraclass and Pearson's correlation coefficients. The radiographic scores were compared to lung function tests and other clinical data. RESULTS: Both intra- and interobserver agreement were high (r > or = 0.9 and the intraclass correlation coefficient > or = 0.85 with both systems for both samples). Both scoring systems correlated with spirometry results: forced expiratory volume in the first second (FEV1) (r = 0.64 and r = 0.55), FEV1% (r = 0.75 and r = 0.72), and the percentage of forced vital capacity in relation to the predicted value (r = 0.63 and r = 0.056). We found no association between scoring system and sex, age, or body mass index. CONCLUSIONS: Assessment of chest radiographs of adult patients with cystic fibrosis by the Brasfield and Chrispin-Norman scoring systems shows good intra- and interobserver agreement. Both systems correlate well with lung function variables, especially FEV1.

Adult↗

Monitoring of respiratory function before and after cardiopulmonary bypass using side-stream spirometry.

Pulmonary impairment is more frequent after cardiac surgery than after other major surgical procedures. The present study investigates whether, by using standard respiratory monitoring, i.e. side-stream spirometry and blood gas analysis, it is possible to detect changes in pulmonary function secondary to cardiopulmonary bypass. We investigated 18 patients undergoing elective coronary bypass surgery or aortic valve replacement. Cardiopulmonary bypass resulted in a nonsignificant increase in alveolar-arterial oxygen difference from 33.0 +/- 10.6 kPa to 36.1 +/- 12.5 kPa and arterial to end-tidal CO2 tension difference from 0.67 +/- 0.39 kPa to 0.79 +/- 0.54 kPa. Respiratory system resistance was unaltered. In contrast, dynamic compliance decreased significantly after cardiopulmonary bypass from 78.6 +/- 22.9 to 65.4 +/- 22.4 mL cmH2O-1 with open chest and from 61.0 +/- 10.2 to 51.1 +/- 17.2 mL cmH2O-1 with closed chest, compared with corresponding values before cardiopulmonary bypass. In conclusion, pulmonary gas exchange was not compromised after cardiopulmonary bypass, but a diminished respiratory compliance was a consistent finding, even in uncomplicated cardiac surgery using routine respiratory monitoring.

Aged↗

Ultrasound-spirometry and capnography in horses: analysis of measurement reliability.

Ultrasound-spirometry and capnography and the evaluation of corresponding 'single-breath diagrams for CO2' (SBD-CO2) is a relatively new, non-invasive method for assessing pulmonary function in horses. The relative variation and the reliability of observations within measurement sessions were calculated for expiratory tidal volume, for expired CO2 volume (%) and for the phase II and phase III slopes of the SBD-CO2 in horses without pulmonary disease and in horses suffering from differing degrees of chronic obstructive pulmonary disease. The coefficient of variation of expiratory tidal volume ranged from 0.23 to 0.32 and that of the expiratory CO2 volume from 0.19 to 0.43. The reliability of the measurements can be considered as good for expiratory tidal volume, and as excellent for expiratory CO2. Clinical status had little influence on the descriptive parameters or on the sample statistics of the expiratory tidal volume and expiratory CO2. The slopes of the SBD-CO2 curves had high variation and only moderate to good reliability. Clinical status had a considerable influence on the variation in the slopes of phase II.

Animals↗

3He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry.

BACKGROUND: To use 3Helium (3He)-MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image-based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He-MRI. METHODS: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He-MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He-MRI was calculated from measured functional residual capacity (corrected for supine position) and inspired tidal volume. Image-based global and regional lung volumetries (LV) were performed in three-dimensionally reconstructed 3He-MR images (corrected for the fraction of tissue and blood). RESULTS: Transplanted lungs were characterized by a homogeneous distribution of signal intensity, whereas the native lungs of the patients suffering from IPF displayed an inhomogeneous signal distribution pattern with numerous round or wedge-shaped ventilation defects. Total ventilated lung volume determined by 3He-MRI correlated well with PFT-based measurements, but with a systematic overestimation of the 3He-based lung volumetry of approximately 20%. Functioning lung grafts contributed 66+/-6% and their corresponding native IPF lungs 34+/-6% to total ventilated volume (P<0.05; mean+/-SD). CONCLUSION: 3Helium-MRI of the lung offers a novel approach to regional determination of ventilated lung volume, including its blood and tissue compartments. The advantage of this technique over computed tomography or ventilation scintigraphy is the lack of radiation exposure, and hence its repeatability. Follow up of SLTX patients with this new technique may allow the monitoring of functional and structural developments of grafted lungs with better sensitivity and specificity than PFT.

Female↗

Hypoxia, hypocapnia and spirometry at altitude.

1. Both hypoxia and hypocapnia can cause broncho-constriction in humans, and this could have a bearing on performance at high altitude or contribute to altitude sickness. We studied the relationship between spirometry, arterial oxygen saturation and end-tidal carbon dioxide (ETCO2) concentration in a group of healthy lowland adults during a stay at high altitude, and then evaluated the response to supplementary oxygen and administration of a beta 2 agonist. 2. We collected spirometric data from 51 members of the 1994 British Mount Everest Medical Expedition at sea level (barometric pressure 101.2-101.6 kPa) and at Mount Everest Base Camp in Nepal (altitude 5300 m, barometric pressure 53-54.7 kPa) using a pocket turbine spirometer. A total of 205 spirometric measurements were made on the 51 subjects during the first 6 days after arrival at Base Camp. Further measurements were made before and after inhalation of oxygen (n = 47) or a beta 2 agonist (n = 39). ETCO2 tensions were measured on the same day as spirometric measurements in 30 of these subjects. 3. In the first 6 days after arrival at 5300 m, lower oxygen saturations were associated with lower forced expiratory volume in 1 s (FEV1; P < 0.02) and forced vital capacity (FVC; P < 0.01), but not with peak expiratory flow (PEF). Administration of supplementary oxygen for 5 min increased oxygen saturation from a mean of 81%-94%, but there was no significant change in FEV1 or FVC, whilst PEF fell by 2.3% [P < 0.001; 95% confidence intervals (CI) -4 to -0.7%]. After salbutamol administration, there was no significant change in PEF, FEV1 or FVC in 35 non-asthmatic subjects. Mean ETCO2 at Everest Base Camp was 26 mmHg, and a low ETCO2 was weakly associated with a larger drop in FVC at altitude compared with sea level (r = 0.38, P < 0.05). There was no correlation between either ETCO2 or oxygen saturation and changes in FEV1 or PEF compared with sea-level values. 4. In this study, in normal subjects who were acclimatized to hypobaric hypoxia at an altitude of 5300 m, we found no evidence of hypoxic broncho-constriction. Individuals did not have lower PEF when they were more hypoxic, and neither PEF nor FEV1 were increased by either supplementary oxygen or salbutamol. FVC fell at altitude, and there was a greater fall in FVC for subjects with lower oxygen saturations and probably lower ETCO2.

Administration, Inhalation↗

Comparison between specified percentage and fifth percentile criteria for spirometry interpretation in Thai patients.

OBJECTIVES: The present study was conducted to determine the degree of agreement between the interpretation of spirometry using a specified percentage of predicted value (SPC) and the fifth percentile (FPC) as the cut off between normal and abnormal. METHODOLOGY: Spirometric values were collected for 1754 subjects attending the respiratory service at Siriraj Hospital between February 2000 and April 2001. These values included forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC, maximal mid-expiratory flow (FEF25-75%) and peak expiratory flow (PEF). A comparison of results between SPC and FPC was performed. The SPC cut-off values for FVC, FEV1, FEV1/FVC, FEF25-75% and PEF were 80% predicted, 80% predicted, 70%, 65% predicted and 80% predicted, respectively. The FPC cut-off values were calculated from reference equations for the Thai population. Inter-rater agreement was calculated as the kappa score. RESULTS: High kappa scores were obtained for FVC (0.84), FEV1 (0.88) and FEF25-75% (0.80). However, poor agreement was found for FEV1/FVC (0.72) and PEF (0.61). When the cut-off values for SPC were modified to 90% of predicted values for FEV1/FVC and to 65% of predicted values for PEF, agreement was substantially improved to 0.92 and 0.89, respectively. CONCLUSIONS: Interpretation by SPC using cut-off values of 80% predicted for FVC and FEV1 and 65% predicted for FEF25-75% resulted in good agreement with FPC. However, the SPC cut-off values for FEV1/FVC and PEF should be modified to 90% predicted and 65% predicted, respectively.

Adolescent↗

[Planimetric determination of lung volume--a complement to spirometry].

The total volume of the lungs was determined by digital planimetry in 102 patients with emphysema and 33 normal controls aged between 30 and 79 years. The results were compared with the findings obtained from spirometric measurements. Mean values showed a significant relationship to age, body size and body surface. Planimetrically determined lung volume did not show a linear relationship with age, but increased after 60 years. Beyond 60 years, spirometric findings were lower because of an increase in the number of patients with emphysema. The results have shown that digital planimetry is a useful addition to spirometry.

Adult↗

Spirometry in office practice: getting full measure from a useful tool.

Spirometry is a simple but underutilized test that is particularly well suited for office practice. With it, the physician can distinguish among different types of ventilatory impairment and follow the patient's course. It also permits detection of small-airway disease at an early stage, when measures to prevent development of chronic bronchitis and emphysema may be effective.

Expiratory Reserve Volume↗

The impact of repeated spirometry and smoking cessation advice on smokers with mild COPD.

BACKGROUND: Smoking cessation is the most important therapeutic intervention in patients with chronic obstructive pulmonary diseases (COPD) and the health benefits are immediate and substantial. Major efforts have been made to develop methods with high smoking cessation rates. OBJECTIVES: To study whether a combination of spirometry and brief smoking cessation advice to smokers with COPD, annually for three years, increased their smoking cessation rate in comparison with groups of smokers with normal lung function. METHOD: Prospective, randomized study in primary care. Smoking cessation rates were compared between smokers with COPD followed-up yearly over a period of three years and smokers with normal lung function followed-up yearly for three years or followed-up only once after three years. RESULTS: The point-prevalence abstinence rate and prolonged abstinence rate at 6 and 12 months increased yearly and in smokers with COPD at year 3 was 29%, 28%, and 25%, respectively. The abstinence rates were significantly higher in smokers with COPD than in smokers with normal lung function. Smoking cessation rates among smokers with normal lung function did not increase with increasing number of follow-ups. CONCLUSION: Smokers diagnosed with COPD stopped smoking significantly more often than those with normal lung function.

Adult↗

Effect of a microaerosol filter on spirometry in children with cystic fibrosis.

AIM: To measure the effect of an in-line microaerosol filter on spirometric values in cystic fibrosis (CF). METHODS: Twenty-six subjects with CF undertook a randomized, open, cross-over comparison of spirometry with and without an in-line filter. RESULTS: The filter had no significant effect on spirometric parameters nor was there any order effect. Measurement error was unrelated to the magnitude of the measurement. CONCLUSION: In-line microaerosol filters do not affect spirometric values or variability in children with CF.

Adolescent↗

Computer assisted spirometry.

Three of the most popular microcomputers, the TRS-80 Model I, the APPLE II+, and the IBM Personal Computer were connected to a spirometer for data acquisition and analysis. Simple programs were written which allow the collection, analysis and storage of the data produced during spirometry. Three examples demonstrate the relative ease for automating spirometers.

Computers↗

Physical activity, spirometry and quality-of-life in chronic obstructive pulmonary disease.

Chronic obstructive pulmonary disease (COPD) has a high level of morbidity. There is limited information about levels of physical activity among community dwelling subjects with the disease and its association with lung function and quality of life. In this study, 176 subjects with COPD were recruited from general practices. Physical activity was measured over 7 days using pedometers, quality-of-life using the St. George's Respiratory Questionnaire, and lung function using spirometry, 124 subjects, 60% male, aged 70 +/- 8 years were included in the analysis. Physical activity levels were low, median steps/day for males = 3621, IQR = 4247 and for females = 4287, IQR = 3063. Overall physical activity (median steps/day = 3716, IQR = 3682) was significantly associated with the forced expiratory volume in one second (r = 0.39, p < 0.001) and with St. George's Respiratory Questionnaire score (r = -0.28, p < 0.01). In conclusion, we have demonstrated that in a community-based sample of people with COPD, daily physical activity levels were low compared with usual levels reported for the general population. Physical activity was significantly associated with disease severity, measured by lung function, and quality-of-life.

Aged↗

Continuous spirometry: an aid to monitoring ventilation during operation.

We present six case-reports of patients who experienced inadequate ventilation as a result of endobronchial or oesophageal intubation, or obstruction to the tracheal tube or airway and were monitored with on-line spirometry. The continuously displayed pressure-volume or flow-volume loops may be compared with previously recorded baseline loops. The changing configuration of the curves offers additional and instantaneous information about the cause of increased inspiratory airway pressure, decreased compliance or increased airway resistance. Monitoring flow-volume and pressure-volume loops in conjunction with currently available techniques provides a comprehensive method of monitoring ventilation.