Use of the variable-length intraluminal sutureless graft.

From August 1987 to May 1988 we treated 4 patients with acute ascending aortic dissections with a variable-length intraluminal aortic prosthesis. This operation uses profound hypothermic circulatory arrest and represents a refinement of existing techniques. There was no mortality, and morbidity was minimal. Modifications of this technique can be used in performing proximal aortic root reconstruction with a composite valved conduit. The use of a variable-length intraluminal prosthesis and hypothermic circulatory arrest is illustrated. This is a safe and useful technique in select cases of acute ascending aortic dissection.

Aged↗

Subacute cardiac rupture: repair with a sutureless technique.

Thirteen patients with ages between 53 and 74 years had development of free wall left ventricular rupture after a myocardial infarction (mean interval, 3.8 days). All patients showed clinical signs of cardiac tamponade. Diagnosis was established by bedside multiple pressure monitoring and echocardiography, which showed pericardial effusion with compression of the right ventricle. Cardiac catheterization was not performed. A new surgical technique was employed for the repair. After the pericardium was opened and cardiac tamponade was relieved, the myocardial tear was identified. A Teflon patch was applied over the area and glued to the heart surface with a surgical glue (cyanoacrylate). Cardiopulmonary bypass was not used except in a patient with a posterior tear. The method was consistently effective in controlling bleeding from the myocardial tear. All patients survived the operation and were discharged from the hospital a mean of 15 days after the operation. Follow-up extending up to 5 years (mean, 26 months) shows a 100% survival, 11 asymptomatic patients, and 2 patients with mild exertional angina. The technique is a simple, effective, and safe method for repair of subacute cardiac rupture and obviates the need for suturing on an infarcted ventricle.

Aged↗

Sutureless hemisplenectomy.

Splenic salvage following blunt injury can fail when parenchymal bleeding is uncontrollable. To define the usefulness of an argon beam coagulator for hemostasis, we used the instrument in a laboratory trial of partial splenic resection. New Zealand white rabbits, weighing 4 to 5 kg, had sharp excision of the lower half of the spleen. No sutures were used to control hemorrhage from the cut splenic surface or the hilar vessels. Hemostasis was achieved with 2 to 4 seconds of electrocoagulation delivered by a beam of argon gas. All animals survived the procedure and were in good health when killed between the fourth and sixth week following the procedure. At necropsy, the spleen was viable in all animals with no abscess or hematoma. Minimal adhesions from the treated splenic surface to the omentum were found. The scar at the cut surface was 1 mm in depth, and the histology of the remainder of the spleen was normal. In this simulated splenic injury model, argon beam coagulation was uniformly successful in achieving hemostasis. Minimal tissue destruction and lack of infection were noted. The argon beam coagulator may be useful in patients with severe splenic injuries and other situations requiring partial splenectomy.

Animals↗

Sutureless vasovasostomy: new technique using experimental microclip in rat model.

Standard microscopic suture vasovasostomy represents a challenge to many urologists. It is technically demanding, and requires two to five hours of operative time. In an attempt to decrease the technical demand and the time requirement, we report the use of a microvascular anastomotic clip and compare this microclip to a standard eight-suture nonstented technique and a six-suture stented technique using a hollow, absorbable 0.5-mm polyglycolic acid stent. The control group with suture required an average of 38.5 minutes per anastomosis for the nonstented group and twenty-two minutes for the stented group. The clip group required 7.6 minutes for the unstented vasovasostomy and 6.5 minutes for the stented vasovasostomy. We obtained a 91 percent patency rate for the stented clip group and 100 percent patency for the unstented clip group. In a rat vasovasostomy, the operative time as well as the inherent technical demand were significantly reduced.

Animals↗

Sutureless avascular meniscal repair with a photoactive naphthalimide compound: a preliminary animal study.

PURPOSE: The purpose of this study was to evaluate the ability of 2 new photoactive naphthalimide compounds to repair a lesion in the avascular zone of the meniscus. TYPE OF STUDY: In vivo animal study. METHODS: Ten Barbados sheep were used as the animal model. Under anesthesia, the left knee joint was opened and 2 identical lesions were produced in the avascular zone of the medial meniscus. The posterior horn lesion was left alone and used as the control and the lesion in the anterior horn was repaired using the photoactive laser technique. The photoactive laser technique involved placing small amounts of a naphthalimide compound into the lesion and then irradiating the site with a laser (457 nm and 1.8 W/cm2) for 6 minutes. Two different versions of the naphthalimide compound were produced and divided between the 10 animals. The joint was then flushed with normal saline and closed in layers with resorbable sutures. Four animals were euthanized at the end of 1 month and 6 animals were euthanized at the end of 3 months. After death, the medial meniscus was exposed, dissected free, and then placed in 10% buffered formalin for histologic preparation and staining. RESULTS: At 1 month, the control lesions grossly showed no repair and the photochemically repaired lesions appeared to be bonded. The photochemically repaired lesions showed some bridging by an eosinophilic amorphous-appearing substance. The previous cleft within the fibrocartilaginous structure had disappeared, and early formation of connective tissue fibers was identified. However, some reduction in cellularity was seen in these tissue sections. At 3 months, again the control lesions did not show any repair response, while the photochemically repaired lesions showed results similar to the animals at 1 month, but with a less consistent pattern of tissue bonding and remodeling. The reduced tissue cellularity was still noted. There was no discernible difference between the naphthalimide compounds. CONCLUSIONS: These preliminary results demonstrate the potential usefulness of this photochemical bonding for the treatment of avascular meniscal lesions. Additional research will be necessary to fully understand the mechanism of this repair and optimize its use before any human trials. CLINICAL RELEVANCE: This is a preliminary animal study investigating the short-term in vivo effects of a novel photochemical compound for the repair of meniscal lesions. This repair may someday be valuable in the repair of avascular meniscal lesions.

1-Naphthylamine↗

Biomechanical comparison of bioabsorbable sutureless screw anchor versus suture anchor fixation for rotator cuff repair.

PURPOSE: Anchors that directly fix the rotator cuff to bone without using sutures may simplify the challenges associated with arthroscopic rotator cuff repair. This study compared a bioabsorbable screw fixation device to a standard suture anchor fixation method. TYPE OF STUDY: Randomized trial. METHODS: A poly-L-lactide acid (PLLA), bioabsorbable screw anchor was compared with a metallic suture anchor loaded with No. 2 braided polyester suture in 12-week-old fresh-frozen bovine shoulders. Twelve specimens were randomly assigned to the 2 repair groups (6 per group). A 1 x 2-cm defect was created at the insertion site of the infraspinatus tendon. Two anchors were implanted 1 cm apart in the anatomic insertional area of the infraspinatus tendon. After preconditioning to 10 N, each construct was cycled between 10 and 180 N for up to a maximum of 2,500 cycles at a rate of 33 mm/second using a materials testing machine. The number of cycles to 5- and 10-mm gap formation at the repair site and mode of failure were recorded. Clinically, 10-mm gap formation defines complete fixation failure. Data were evaluated using an analysis of variance with significance set at P < .05. RESULTS: Mattress suture fixation had significantly higher number of cycles to 10-mm failure compared with the PLLA device (P = .015). Failure occurred by tissue pullout in half the specimens and by device failure in the other half, without differences in failure modalities between groups. CONCLUSIONS: This anchor provides low-profile fixation of the rotator cuff and eliminates suture placement and knot tying during arthroscopic and mini-open cuff repair. However, these data suggest that this anchor may not perform adequately under cyclic loading conditions in patients during postoperative rehabilitation. CLINICAL RELEVANCE: This bioabsorbable anchor may not provide sufficient fixation for rotator cuff repair in humans.

Absorbable Implants↗

Sutureless otoplasty by scoring of the cartilage: a study in 34 patients.

The aim of correction of prominent ears is to improve cosmesis, preferably without complications. We used cartilage scoring with a surgical blade while controlling the degree of helical fold created with fine diathermy at the edge of fold. Thirty-four consecutive patients had bilateral correction, with a mean follow-up of 6 months. Their mean age was 8 years 3 months (range 6-18 years), and there were 16 boys and 18 girls. Twenty-six required general anaesthesia and eight had a local anaesthetic. Postoperative complications included one bleed that was controlled by a change of dressing, and an infection in one ear (treated with antibiotics). There were no haematomas, wound breakdowns, or protrusion of sutures (no sutures were used generally except for deep conchal bowl where conchomastoid sutures were used). We think that the low complication rate is the result of maximising the advantages and minimising the disadvantages of the different techniques. We recommend this technique for the routine correction of prominent ears as a result of a poorly formed antihelical fold or deep conchal bowl.

Adolescent↗

Transapical approach for sutureless stent-fixed aortic valve implantation: experimental results.

OBJECTIVE: Percutaneous aortic valve implantation has been performed in patients with severe aortic stenosis judged as nonsurgical candidates. We evaluated a facilitated transapical antegrade approach for potential use in surgical high-risk patients. METHODS: A pericardial xenograft fixed within a 23-mm stent (Cribier-Edwards aortic prosthesis, Edwards Inc., Irvine, CA, USA) was implanted using a transapical approach in fifteen 35-45 kg pigs. A limited or a full sternotomy was used to transapically introduce a crimped valve through a 24-F sheath. Deployments were performed on the beating heart either with ventricular unloading using femoro-femoral cardiopulmonary bypass (CPB) or rapid ventricular pacing (RVP), all under fluoroscopic and echocardiographic visualization. RESULTS: All valves were successfully deployed at the target site with acceptable visualization of the noncalcified annulus. Valve migration occurred in six procedures (three distal and three retrograde) secondary to inadequate reduction of ventricular output, unfavorable annular anatomy, excessive crimping of the valve, and dislodgement by the delivery balloon. Exact positioning of the valve into the target area was confirmed by autopsy at the end of the procedures. Paravalvular leak was noted in five implants. CONCLUSIONS: The transapical approach provides a safe, accurate, and effective route for facilitated antegrade delivery of a stent-fixed valve. Advanced stent design will lead to better stability of the implant and may minimize the risk of paravalvular leakage in future. Identifying the appropriate population for human feasibility trials remains a challenge.

Animals↗

Sutureless ophthalmic surgery: a scaffold-enhanced bioadhesive technique.

PURPOSE: Bioadhesives have had limited use in ophthalmic surgery. Problems with these adhesives have included inadequate tensile strength and difficulty with their application to the tissue site. We evaluated a scaffold-enhanced cyanoacrylate bioadhesive composite as an alternative to sutures in ophthalmic surgery, including strabismus procedures. METHODS AND MATERIALS: The bioadhesive composite consisted of 2-octyl-cyanoacrylate combined with either a poly(L-lactic-co-glycolic acid) (PLGA) scaffold or a rehydrated porcine small intestine submucosa (SIS) scaffold. Extraocular rectus muscle and sclera were obtained from rabbits (n = 40) and were used, with these bioadhesive composites, to produce rectus muscle-to-sclera, sclera-to-sclera, and rectus muscle-to-rectus muscle adhesions. Control adhesions were created with cyanoacrylate only. The breaking load of the tissue repair was measured with a material strength-testing machine. RESULTS: In all cases, the scaffold-enhanced cyanoacrylate adhesions were significantly stronger (P < 0.001) than the cyanoacrylate alone. The rectus muscle-to-sclera adhesions were greater than the in vivo forces reported for the horizontal rectus muscles in humans in extreme gaze. CONCLUSION: This scaffold-enhanced bioadhesive composite produced initial muscle-sclera adhesions with strength satisfactory for strabismus surgery. It also may be applicable to other categories of ophthalmic surgery as a substitute for sutures.

Animals↗

Traumatic expulsive iridodialysis after small-incision sutureless cataract surgery.

Phacoemulsification with intraocular lens (IOL) implantation was performed in the right eye of an 84-year-old woman using a small clear corneal incision. Ten weeks after surgery, the patient fell, which caused traumatic iridodialysis and hyphema with expulsion of the iris through the surgical corneal incision. Apart from a transient rise in intraocular pressure, no other complication was identified and the visual acuity returned to 20/20 within 2 months. The IOL remained in situ and undisturbed in the capsular bag, and the retina remained flat, suggesting that an IOL in the capsular bag may provide a stable barrier to prevent tissue loss from the posterior segment.

Accidental Falls↗