An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode.

Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.

Aminophenols↗

Amperometric cholesterol biosensor based on in situ reconstituted cholesterol oxidase on an immobilized monolayer of flavin adenine dinucleotide cofactor.

A new amperometric biosensor for determining cholesterol based on deflavination of the enzyme cholesterol oxidase (ChOx) and subsequent reconstitution of the apo-protein with a complexed flavin adenine dinucleotide (FAD) monolayer is described. The charge transfer mediator pyrroquinoline quinone (PQQ) was covalently bound to a cystamine self-assembled monolayer (SAM) on an Au electrode. Boronic acid (BA) was then bound to PQQ using the carbodiimide procedure, and the BA ligand was complexed to the FAD molecules on which the apo-ChOx was subsequently reconstituted. The effective release of the FAD from the enzyme and the successful reconstitution were verified using molecular fluorescence and cyclic voltammetry. The optimal orientation of FAD toward the PQQ mediator and the distances between FAD and PQQ and between PQQ and electrode enhance the charge transfer, very high sensitivity (about 2,500 nAmM(-1)cm(-2)) being obtained for cholesterol determination. The biosensor is selective toward electroactive interferents (ascorbic acid and uric acid) and was tested in reference serum samples, demonstrating excellent accuracy (relative errors below 3% in all cases). The biosensor activity can be successfully regenerated in a simple process by successive reconstitution with batches of recently prepared apo-ChOx on the same immobilized Au/SAM-PQQ-BA-FAD monolayer (it was tested five times); the lifetime of the biosensor is about 45-60 days.

Biosensing Techniques↗

Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode.

An amperometric enzyme biosensor for the determination of choline utilizing two enzymes, choline oxidase (CHOD) and horseradish peroxidase (HRP), is described. The biosensor consisted of CHOD cross-linked onto a HRP-immobilized carbon paste electrode. The biosensor was prepared by in situ electropolymerization of poly(thionine) within a carbon paste containing the enzyme HRP and thionine monomer and then CHOD was immobilized by using chitosan film through cross-linking with glutaraldehyde. The in situ electrogenerated poly(thionine) displays excellent electron transform efficiency between the enzyme HRP and the electrode surface, and the polymer enables improvement in enzyme immobilization within the paste. Several parameters such as the amount of thionine and enzyme, the applied potential, the pH, etc. have been studied. Amperometric detection of choline was realized at an applied potential of -0.2V vs saturated calomel electrode in 1/15M phosphate buffer solution (pH 7.4) with a linear response range between 5.0 x 10(-6) and 6.0 x 10(-4)M choline and a response time of 15s. When applied to the analysis of phosphatidylcholine in serum samples, a 0.997 correlation was obtained between the biosensor results and those obtained by a hospital method.

Alcohol Oxidoreductases↗

A comparison of different strategies for the construction of amperometric enzyme biosensors using gold nanoparticle-modified electrodes.

A comparison of the analytical performances of several enzyme biosensor designs, based on the use of different tailored gold nanoparticle-modified electrode surfaces, is discussed. Glucose oxidase (GOx) and the redox mediator tetrathiafulvalene were coimmobilized in all cases by crosslinking with glutaraldehyde. The biosensor designs tested were based on the use of (i) colloidal gold (Au(coll)) bound on cysteamine (Cyst) monolayers self-assembled on a gold disk electrode (AuE) and (ii) glassy carbon electrodes (GCEs) modified with electrodeposited gold nanoparticles (nAu). The results obtained with these designs were compared with those provided by a GOx/Cyst-AuE and a GOx/MPA-AuE. In the second case (ii), configurations based on direct immobilization of GOx on nAu (GOx/nAu-GCE) or on Cyst or MPA self-assembled monolayers (SAMs) previously bound on gold nanoparticles (GOx/Cyst-nAu-GCE or GOx/MPA-nAu-GCE, respectively) were compared. The analytical characteristics of glucose calibration plots and the kinetic parameters of the enzyme reaction were compared for all of the biosensors tested. The GOx/Au(coll)-Cyst-AuE design showed a sensitivity for glucose determination higher than that achieved with GOx/Cyst-AuE and GOx/Au(coll)-Cyst/Cyst-AuE and similar to that achieved with GOx/MPA-AuE. Moreover, the useful lifetime of one single GOx/Au(coll)-Cyst-AuE was 28 days, remarkably longer than that of the other GOx biosensor designs.

Biosensing Techniques↗

Electrodeposited nonconducting polytyramine for the development of glucose biosensors.

Biosensors with the composition of carbon/Prussian blue/(glucose oxidase+glutaraldehyde+polytyramine) were constructed. Before tyramine monomers were electropolymerized, glucose oxidase and tyramine monomers were cross-linked with glutaraldehyde onto the surface of Prussian-blue-modified electrodes. The constructed biosensors produced highly reproducible and stable devices. The biosensors exhibited neglectable decrease in current response after 10 repeated uses or after 1 month of dry storage. The resultant biosensors had a linear range of 0.1-1 mM glucose and a detection limit of 0.05 mM. Since the following electrocatalytic process proceeds at a low electrode potential (ca. -0.3 V vs Ag/AgCl), ascorbate and uric acid do not produce observable interfering signal for the determination of glucose.

Aspergillus niger↗

A mediator-free phenol biosensor based on immobilizing tyrosinase to ZnO nanoparticles.

A mediator-free phenol biosensor was developed. The low-isoelectric point tyrosinase was adsorbed on the surface of high-isoelectric point ZnO nanoparticles (nano-ZnO) facilitated by the electrostatic interactions and then immobilized on the glassy carbon electrode via the film forming by chitosan. It was found that the nano-ZnO matrix provided an advantageous microenvironment in terms of its favorable isoelectric point for tyrosinase loading and the immobilized tyrosinase retaining its activity to a large extent. Moreover, there is no need to use any other electron mediators. Phenolic compounds were determined by the direct reduction of biocatalytically generated quinone species at -200mV (vs. saturated calomel electrode). The parameters of the fabrication process and the various experimental variables for the enzyme electrode were optimized. The resulting biosensor can reach 95% of steady-state current within 10s, and the sensitivity was as high as 182microAmmol(-1)L. The linear range for phenol determination was from 1.5x10(-7) to 6.5x10(-5)molL(-1) with a detection limit of 5.0x 10(-8)molL(-1) obtained at a signal/noise ratio of 3. In addition, the apparent Michaelis-Menten constant (K(m)(app)) and the stability of the enzyme electrode were estimated. The performance of the developed biosensor was compared with that of biosensors based on other immobilization matrices.

Agaricales↗

A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment.

A novel glucose biosensor was constructed by electrochemical entrapment of glucose oxidase (GOD) into porous poly(acrylonitrile-co-acrylic acid), which was synthesized via radical polymerization of acrylonitrile and acrylic acid. The obtained biosensor showed a better stability and higher sensitivity than the biosensor prepared by simple physical adsorption. Effects of some experimental variables such as immobilization time, enzyme concentration, pH, applied potential, and temperature on the amperometric response of the sensor were investigated. The biosensor exhibited a rapid response to glucose (< 30s) with a linear range of 5 x 10(-6) to 3 x 10(-3)M and a sensitivity of 6.82 mAM(-1)cm(-2). The apparent Michaelis-Menten constant (K(M)(app)) was 7.3mM.

Acrylates↗

A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor.

A novel film of chitosan-gold nanoparticles is fabricated by a direct and facile electrochemical deposition method and its application in glucose biosensor is investigated. HAuCl(4) solution is mixed with chitosan and electrochemically reduced to gold nanoparticles, which can be stabilized by chitosan and electrodeposited onto glassy carbon electrode surfaces along with the electrodeposition of chitosan. Then a model enzyme, glucose oxidase (GOD) is immobilized onto the resulting film to construct a glucose biosensor through self-assembly. The resulting modified electrode surfaces are characterized with both AFM and cyclic voltammetry. Effects of chitosan and HAuCl(4) concentration in the mixture together with the deposition time and the applied voltage on the amperometric response of the biosensor are also investigated. The linear range of the glucose biosensor is from 5.0 x 10(-5) approximately 1.30 x 10(-3) M with a Michaelis-Menten constant of 3.5 mM and a detection limit of about 13 microM.

Biosensing Techniques↗

Application of biochemical oxygen demand (BOD) biosensor for optimization of biological carbon and nitrogen removal from synthetic wastewater in a sequencing batch reactor system.

A bench scale reactor using a sequencing batch reactor process was used to evaluate the applicability of biosensors for the process optimization of biological carbon and nitrogen removal. A commercial biochemical oxygen demand (BOD) biosensor with a novel microbial membrane was used to determine the duration of each phase by measuring samples in real time in an SBR cycle with filling/anoxic-anaerobic/aerobic/sludge wasting/settling/withdrawal periods. Possible strategies to increase the efficiency for the biological removal of carbon and nitrogen from synthetic wastewater have been developed. The results show that application of a BOD biosensor enables estimation of organic carbon, in real time, allowing the optimization or reduction the SBR cycle time. Some typical consumption patterns for organic carbon in the non-aeration phase of a typical SBR operation were identified. The rate of decrease of BOD measured using a sensor BOD, was the highest in the initial glucose breakdown period and during denitrification. It then slowed down until a 'quiescent period' was observed, which may be considered as the commencement of the aeration period. Monitoring the BOD curve with a BOD biosensor allowed the reduction of the SBR cycle time, which leads to an increase in the removal efficiency. By reducing the cycle time from 8 to 4 h cycle, the removal efficiencies of nitrate, glucose, and phosphorus in a given time interval, were increased to nearly double, while the removal of nitrogen ammonium was increased by one-third.

Bacteria, Aerobic↗

An amperometric inhibitor biosensor for the determination of reduced glutathione (GSH) without any derivatization in some plants.

In this study, an amperometric biosensor based on cucumber tissue homogenate was developed for the determination of glutathione. Cucumber (Cucumis sativus L.) tissue homogenate was used as the biological material. The cucumber tissue homogenate was cross-linked with gelatine using glutaraldehyde and fixed on a pretreated teflon membrane. The principle of the measurements was based on the determination of the decrease in the differentiation of oxygen level which had been caused by the inhibition of ascorbate oxidase in the biological material by glutathione. Determinations were carried out by standard curves which were obtained by the measurement of the decrease in the consumed oxygen level related to glutathione concentration. Optimization and characterization studies of the biosensor were carried out and a linearity in the gamma-L-glutamyl-L-cysteinyl-glycine (GSH) concentration range 0.1-2 microM was obtained when 600 microM ascorbic acid was used as a substrate. The repeatability experiments (n = 7) revealed that for 1.5 microM GSH, the average value (x), standard deviation (S.D.) and variation coefficient (C.V.) were 1.517 microM, 4.72 x 10(-5) 3.11%, respectively. The biosensor useful lifetime was at least 2 months. The results of some plant samples analyzed with the presented biosensor agreed well with the spectrophotometric method (Ellman's reagent) used as a reference.

Ascorbate Oxidase↗

A novel nanolayer biosensor principle.

A method for eliminating the mass transport limitation on biosensor surfaces is introduced. The measurement of macromolecular binding kinetics on plane surfaces is the key objective of many evanescent wave (e.g. total internal reflection fluorescence (TIRF)), and surface plasmon resonance (SPR) based biosensor systems, allowing the determination of binding constants within minutes or hours. However, these methods are limited in not being rigorously applicable to large macromolecules like proteins or DNA, since the on-rates are transport limited due to a Nernst diffusion layer of 5-10 microm thickness. Thus, for the binding of fibrinogen (340 kDa) to a surface current SPR biosensors will show a mass transport coefficient of ca. 2 x 10(-6) m/s. In a novel approach with an immiscible fluid vesicle (e.g. air bubble), it has been possible to generate nanoscopic fluid films of ca. 200 nm thickness on the sensor surface of an interfacial TIRF rheometer system. The thickness of the liquid film can be can be easily probed and measured by evanescent wave technology. This nanofilm technique increases the mass transport coefficient for fibrinogen to ca. 1 x 10(-4) m/s eliminating the mass transport limitation, making the binding rates reaction-rate limited. From the resulting exponential kinetic functions, lasting only 20-30s, the kinetic constants for the binding reaction can easily be extracted and the binding constants calculated. As a possible mechanism for the air bubble effect it is suggested that the aqueous fluid flow in the rheometer cell is separated by the air bubble below the level of the Nernst boundary layer into two independent laminar fluid flows of differing velocity: (i) a slow to stationary nanostream ca. 200 nm thick strongly adhering to the surface; and (ii) the bulk fluid streaming over it at a much higher rate in the wake of the air bubble. Surprising properties of the nanofluidic film are: (i) its long persistence for at least 30-60s after the air bubble has passed (2.5s); and (ii) the absence of solute depletion. It is suggested that a new liquid-liquid interface (i.e. a "vortex sheet") between the two fluid flows plays a decisive role, lending metastability to the nanofluidic film and replenishing its protein concentration via the vortices-thus upholding exponential binding kinetics. Finally, the system relaxes via turbulent reattachment of the two fluid flows to the original velocity profile. It is concluded that this technique opens a fundamentally novel approach to the construction of macromolecular biosensors.

Biosensing Techniques↗

Development of novel conductometric biosensors based on immobilised whole cell Chlorella vulgaris microalgae.

A novel biosensor based on immobilised whole cell Chlorella vulgaris microalgae as a bioreceptor and interdigitated conductometric electrodes as a transducer has been developed and tested for alkaline phosphatase activity (APA) analysis. These sensors were also used for the detection of toxic compounds, namely cadmium ions, in aquatic habitats. Algae were immobilised inside bovine serum albumin (BSA) membranes cross-linked with glutaraldehyde vapours. The detection of the local conductivity variations caused by algae enzymatic reactions could be achieved. The inhibition of C. vulgaris microalgae Alkaline phosphatase activities in presence of cadmium ions was measured. These results were compared with measurements in bioassays. It finally appeared that conductometric biosensors using algae seemed more sensitive than bioassays to detect low levels of cadmium ions (the detection limit for the first experiments was 1 ppb of Cd2+). The main advantages of these alkaline phosphatase biosensors consist of their high specificity in regard to the toxic compounds they enable to detect, but also on their high stability since contrary to enzymatic biosensors, they use whole algae cells with APs on their walls.

Alkaline Phosphatase↗

Comparison of a prototype magnetoresistive biosensor to standard fluorescent DNA detection.

We present a comparative analysis of a magnetoresistive biosensor to standard fluorescent DNA detection. The biosensor consists of giant magnetoresistive (GMR) type Cu/Ni(80)Fe(20) multilayers in the second antiferromagnetic coupling maximum. Each of the 206 elements of the magnetoresistive biosensor is patterned into a spiral-shaped line that can cover the area of a typical DNA spot (70 microm diameter). The probe DNA is assembled on top of the sensor elements in different concentrations ranging from 16 pg/microl to 10 ng/microl. Complementary biotin-labeled analyte DNA is hybridized to the probe DNA at a concentration of 10 ng/microl. A number of different commercially available magnetic microspheres are investigated to determine the most appropriate markers. The experimental comparison shows that the relative sensitivity of the magnetoresistive biosensor is superior to the fluorescent detection at low probe DNA concentrations.

Biosensing Techniques↗

A novel ultrahigh-resolution surface plasmon resonance biosensor with an Au nanocluster-embedded dielectric film.

The detection performance of conventional surface plasmon resonance (SPR) biosensors is limited to a 1 pg/mm(2) surface coverage of biomolecules, and consequently, such sensors struggle to detect the interaction of small molecules in low concentrations. The present study is attempted to propose the use of a novel SPR biosensor with Au nanoclusters embedded in a dielectric film to achieve a 10-fold improvement in the resolution performance. A co-sputtering method utilizing a multi-target sputtering system is used to fabricate the present dielectric films (SiO(2)) with embedded Au nanoclusters. It is shown that the sensitivity of the developed SPR biosensor can be improved by adjusting the size and volume fraction of the embedded Au nanoclusters in order to control the surface plasmon effect. The present gas detection and DNA hybridization experimental results confirm that the proposed Au nanocluster-enhanced SPR biosensor provides the potential to achieve an ultrahigh-resolution detection performance of approximately 0.1 pg/mm(2) surface coverage of biomolecules.

Argon↗

Biosensor for the determination of sorbitol based on molecularly imprinted electrosynthesized polymers.

Despite the increasing number of applications of biosensors in many fields, the construction of a steady biosensor remains still challenging. The high selectivity and stability of molecularly imprinted polymers for the template molecule make them ideal alternatives as recognition elements for sensors. In this work, the fabrication and characterization of biosensor based on molecularly imprinted electrosynthesized polymers is reported as the first case of imprinting sorbitol. A relevant molecularly imprinted film is prepared by o-phenylenediamine (o-PD) using the electrochemical method. Quartz crystal microbalance is employed as a sensitive apparatus of biosensor for the determination of sorbitol. An equation is deduced to characterize the interaction between molecularly imprinted films and the template. A linear relationship between the frequency shift and the concentration of analyte in the range of 1-15 mM was found. The detection limit is about 1mM.

Biosensing Techniques↗

Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films.

The development of a new electrochemical sensor consisting in a glass-sealed metal microelectrode coated by a polyethylenimine film is described. The use of polymers as the entrapping matrix for enzymes fulfils all the requirements expected for these materials without damaging the biological material. Since enzyme immobilization plays a fundamental role in the performance characteristics of enzymatic biosensors, we have tested four different protocols for enzyme immobilization to determine the most reliable one. Thus the characteristics of the potentiometric biosensors assembled were studied and compared and it appeared that the immobilization method leading to the most efficient biosensors was the one consisting in a physical adsorption followed by reticulation with dilute aqueous glutaraldehyde solutions. Indeed, the glutaraldehyde immobilized urease sensor provides many advantages, compared to the other types of sensors, since this type of urea biosensor exhibits short response times (15-30s), sigmoidal responses for the urea concentration working range from 1 x 10(-2.5) to 1 x 10(-1.5) M and a lifetime of 4 weeks.

Adsorption↗

Combinatorial augmentation for a multi-pathogen biosensor: signal analysis and design.

Recent advances in combinatorial chemistries have revolutionized approaches to drug candidate synthesis and screening. Combinatorial approaches are also beginning to be used to increase the performance of diagnostic devices for both clinical and field uses. The use of combinatorial technologies is motivated by a general desire to detect as many different pathogens using the smallest, most inexpensive and fastest system possible. We examine the potential for rational design approaches to enhance the performance and miniaturization of biosensors. We describe novel combinatorial biosensor systems, in addition to mathematical frameworks for their optimization and performance prediction. The biosensors are assumed to be composed of multiple detection channels with the following characteristics. Each channel has a single output and can be dynamically set to respond to some or all of a set of pathogens. Regardless of the number of pathogens detected, however, there is a single numerical output from a channel. We evaluate the amount of ambiguity of positive signals produced as a result of increasing both the number of channels and the number of pathogens detected per channel and the effect this ambiguity has on system performance. We further discuss strategies for disambiguating positive signals. Finally we cite specific biosensor configurations that exploit the findings above and compare them to "brute force" approaches. Overall we suggest the approach we refer to as "n-squared" to simultaneously optimize device cost, speed and reagent usage.

Algorithms↗

A sensitivity comparison of optical biosensors based on four different surface plasmon resonance modes.

Current surface plasmon resonance (SPR) modes based on the attenuated total reflection (ATR) method can broadly be categorized as: conventional SPR, long-range SPR (LRSPR), coupled plasmon-waveguide resonance (CPWR), and waveguide-coupled SPR (WCSPR). Although the features of optical biosensors are dependent upon their particular SPR mode, a common requirement for all biosensors utilized for biomolecular interaction analysis (BIA) is a high degree of sensitivity. The current paper presents a theoretical analysis and comparison of the sensitivity and resolution of these four types of SPR biosensors when employed in three of the most prevalent detection methods, namely angular interrogation, wavelength interrogation, and intensity measurement. This study develops a detailed understanding of the influences of various biosensor design parameters in order to enhance the sensitivity and detection limit capabilities of such devices.

Computer Simulation↗