PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Comparison of the effects of ionization mechanism, analyte concentration, and ion "cool-times" on the internal energies of peptide ions produced by electrospray and atmospheric pressure matrix-assisted laser desorption ionization.

The propensities of a series of peptide ions produced by both electrospray and atmospheric pressure matrix assisted laser desorption ionization (AP-MALDI) to fragment in an ion trap mass spectrometer under various conditions were studied in detail by measuring the extent of fragmentation of precursor ions by collision induced dissociation (CID) as a function of applied resonance excitation RF voltage. For the most basic peptides, the energy required to fragment MH+ ions generated by electrospray exceeded that required to fragment equivalent AP-MALDI ions under identical instrumental conditions; the reverse was observed for a peptide incorporating no basic residues, while peptides of intermediate basicity showed little difference between the ionization methods. This correlation between peptide basicity and the difference in the energy required to induce fragmentation of MH+ ions generated by AP-MALDI and electrospray is attributed primarily to a trend in the internal energies of the ions generated by AP-MALDI (the greater the difference in gas-phase basicities between the matrix and the analyte the greater the internal energy of the analyte ions produced). Furthermore the internal energies of ions produced by AP-MALDI, but not the equivalent ions formed by electrospray, were observed to decrease with decreasing analyte concentration. We attribute this finding to the cooling effect of endothermic dissociation of analyte ion/matrix molecule clusters following the matrix assisted laser desorption step. Time-resolved analyses (measurement of extent of fragmentation of precursor ions by CID as a function of pre-CID "cool times") revealed that cooling periods in excess of 250 ms were required to achieve internal energy equilibrium through cooling collisions with the helium buffer gas. Furthermore, these analyses demonstrated that, even after these extended cooling times, equivalent ions formed by the two ionization techniques showed different propensities to fragment. We conclude that the two different ionization techniques produce ion populations that may differ in their three-dimensional structure.

Atmospheric Pressure↗

Liquid infrared atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry of sialylated carbohydrates.

A 2.94-microm Er:YAG laser for IR atmospheric pressure matrix-assisted laser desorption/ionization on an ion trap mass spectrometer is used for the analysis of sialylated oligosaccharides. This approach provided the opportunity to utilize liquid matrixes and is effective in determining structural features--sequence, branching, and linkage--of intact, fully sialylated molecular species.

Atmospheric Pressure↗

N2O removal in N2 or air by ArF excimer laser photolysis at atmospheric pressure.

A photochemical process is proposed as a new efficient N(2)O removal technique in N(2) or air at atmospheric pressure and room temperature without using any catalysts. N(2)O diluted in N(2) or air was decomposed into N(2), O(2), and NO by using a 193 nm ArF excimer laser. The maximum conversion of N(2)O in N(2)O/N(2) or N(2)O/N(2)/O(2) mixtures was 93% at a laser power of 136 mJ, a repetition frequency of 5 Hz, and an irradiation time of 30 min. The formation ratios of N(2):O(2):NO in N(2)O/N(2) and N(2)O/N(2)/O(2) mixtures were 64:31:5.1% and 60:27:13%, respectively. The decomposition mechanism of N(2)O under 193 nm photolysis was discussed by comparing experimental data with calculated model using known photochemical and gas kinetic data.

Air↗

Distinguishing N-oxide and hydroxyl compounds: impact of heated capillary/heated ion transfer tube in inducing atmospheric pressure ionization source decompositions.

In the pharmaceutical industry, a higher attrition rate during the drug discovery process means a lower drug failure rate in the later stages. This translates into shorter drug development time and reduced cost for bringing a drug to market. Over the past few years, analytical strategies based on liquid chromatography/mass spectrometry (LC/MS) have gone through revolutionary changes and presently accommodate most of the needs of the pharmaceutical industry. Among these LC/MS techniques, collision induced dissociation (CID) or tandem mass spectrometry (MS/MS and MS(n)) techniques have been widely used to identify unknown compounds and characterize metabolites. MS/MS methods are generally ineffective for distinguishing isomeric compounds such as metabolites involving oxygenation of carbon or nitrogen atoms. Most recently, atmospheric pressure ionization (API) source decomposition methods have been shown to aid in the mass spectral distinction of isomeric oxygenated (N-oxide vs hydroxyl) products/metabolites. In previous studies, experiments were conducted using mass spectrometers equipped with a heated capillary interface between the mass analyzer and the ionization source. In the present study, we investigated the impact of the length of a heated capillary or heated ion transfer tube (a newer version of the heated capillary designed for accommodating orthogonal API source design) in inducing for-API source deoxygenation that allows the distinction of N-oxide from hydroxyl compounds. 8-Hydroxyquinoline (HO-Q), quinoline-N-oxide (Q-NO) and 8-hydroxyquinoline-N-oxide (HO-Q-NO) were used as model compounds on three different mass spectrometers (LCQ Deca, LCQ Advantage and TSQ Quantum). Irrespective of heated capillary or ion transfer tube length, N-oxides from this class of compounds underwent predominantly deoxygenation decomposition under atmospheric pressure chemical ionization conditions and the abundance of the diagnostic [M + H - O](+) ions increased with increasing vaporizer temperature. Furthermore, the results suggest that in API source decompostion methods described in this paper can be conducted using mass spectrometers with non-heated capillary or ion transfer tube API interfaces. Because N-oxides can undergo in-source decomposition and interfere with quantitation experiments, particular attention should be paid when developing API based bioanalytical methods.

Journal Article↗

Comparison of different sorbent materials for on-line solid-phase extraction with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry of phenols.

On-line solid-phase extraction (SPE) was interfaced to liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) for the determination of US Environmental Protection Agency (EPA) phenols. The system, allowing fully automated operation, was used to evaluate different SPE cartridge materials and dimensions. Six different SPE materials (C18 HD, Polymer Labs PLRP-s, Hamilton PRP-1, Hysphere GP, Hysphere SH and Waters Oasis) were tested. Criteria for their comparison were first the recovery for the different phenols and its reproducibility, but also chromatographically relevant items like peakshape in the on-line elution mode. High recoveries and good relative standard deviations were obtained particularly for the newer, strongly retaining SPE materials that have become commercially available recently (the Hysphere materials and Waters Oasis) compared to the well known silica-based and weaker polymeric adsorbents like PLRP-s and PRP-1. These advantages are, however, traded in for good chromatographic peakshape, since the stronger adsorbents give rise to notable peak broadening in on-line elution. This is particularly true when using APCI-MS detection which on the one hand offers excellent selectivity and sensitivity, but imposes additional restrictions on the mobile phase composition in order not to suppress the response significantly. The influence of these parameters on the on-line-SPE-HPLC-MS determination of EPA phenols is discussed and present limitations are pointed out.

Atmospheric Pressure↗

Simultaneous quantification of A-trichothecene mycotoxins in grains using liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry.

An approach for simultaneous determination of the main type A-trichothecenes by liquid chromatography and atmospheric pressure chemical ionization mass spectrometry is described. Parameters for coupling of LC-MS such as cone voltage, nebulizing temperature and the LC flow-rate, were optimized to provide detection of mycotoxins with maximum sensitivity. Furthermore, the effects of cone voltage and temperature on the fragmentation pattern of the tested toxins were studied. Main type A-trichothecenes such as T-2 Toxin, HT-2 Toxin, acetyl T-2 Toxin, diacetoxyscirpenol, monoacetoxyscirpenol (15-acetoxyscirpenol) and neosolaniol were separated on a reversed-phase narrow bore C18 column, using a linear gradient and a flow-rate of 0.3 ml/min. Mass spectra were obtained in positive ion mode for confirmation and quantitation. The method involves extraction and purification of toxins by using multifunctional Mycosep columns. Deuterated T-2 Toxin was used as an internal standard. A linear working range between 80 and 500 microg/kg in matrix with an acceptable correlation coefficient was observed. The developed method was validated by using a blank oats sample. The detection limit in the matrix was found to be between 50 and 85 microg/kg in selected ion mode for all tested A-trichothecenes. Recovery data were found to be between 77 and 101%. Within run and day-to-day precision were determined as having comparable levels to those found using GC methods. Furthermore, the matrix effect was investigated by comparing the internal standard versus the external standard method in quantification studies. In addition, the developed method was applied for the analysis of naturally contaminated oats, maize, barley and wheat samples.

Atmospheric Pressure↗

Atmospheric pressure mass spectrometry: a new analytical chemical characterization method for dissolved organic matter in rainwater.

The complex mixture of organic compounds in the atmosphere influences climate, air quality, and ecosystem processes. Atmospheric pressure electrospray ionization mass spectrometry (APESI-MS) was evaluated as a potential tool for direct measurement of the total suite of individual dissolved organic matter (DOM) compounds in rainwater. The APESI-MS response was linear to all DOM compounds of atmospheric significance examined as standard solutions. Urban precipitation samples from New Brunswick, NJ (USA) were analyzed by APESI-MS over the mass-to-charge (m/z) range 50-3,000. Over 95% of the m/z ions detected were in the low m/z range (50-500). Over 300 unique m/z ions were detected across the 11 rainwater samples indicating the complexity of the mixture of DOM in rainwater. Forty percent of the organic bases (positive mode detection) and 22% of the organic acids (negative mode) occurred in at least 6 of the 11 rainwater samples. Ions corresponding to the m/z of carboxylic acids standards (nonanedioic acid; 1,4-butanedicarboxylic acid; pentanedioic acid; hydroxybutanedioic acid; and butanedioic acid) and to reduced N standards (allylurea; caffeine; imidazole; and N-2-propenylurea) occurred in at least one of the 11 rainwater samples. Total dissolved organic carbon (DOC) estimated from the APESI-MS analysis and measured by standard DOC methods were not statistically different.

Air Pollutants↗

Analysis of urinary organic acids by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

We developed a new method for the rapid determination of urinary organic acids using liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. Mass spectra of authentic organic acids obtained in the negative-ion mode showed intense [M-H]- ions with some fragment ions. Urine samples of patients with methylmalonic aciduria, ornithine transcarbamylase deficiency, and phenylketonuria were extracted using anion-exchange columns. The mass chromatograms of the extracts showed some dominant peaks of abnormal metabolites characteristic of each disorder. This is a useful method for the analysis of urinary organic acids for the diagnosis of organic aciduria, because the sample preparation is simple.

Acids↗

[Electron excitation temperature of argon dielectric barrier discharge at atmospheric pressure].

The electron excitation temperature was measured by the intensity ratio of two spectral lines in argon dielectric barrier discharge (DBD) at atmospheric pressure. The spectral range is from 690 to 800 nm. It is shown that all of the spectral lines are attributed to neutral Ar atoms. The spectral line 763.51 nm (2P(6)-->1S(5)) and 772.42 nm (2P(2)-->1S(3)) are chosen to estimate the electron excitation temperature. The experimental results show that the electron excitation temperature is in the range of 0.1-0.5 eV. The electron excitation temperature increases with increasing applied voltage, but decreases with increasing gas flow rate. The electron excitation temperature in flowing Ar gas discharge is much different from that in static Ar gas discharge. The result is of great importance to industrial application of DBD.

Algorithms↗

Direct characterization of bitter acids in a crude hop extract by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

The applicability of on-line coupling of reversed-phase high-performance liquid chromatography to atmospheric pressure ionization tandem mass spectrometry for the separation and characterization of hop acids mixture from the crude extract of Humulus lupulus was investigated. The solvent system consisting of acetonitrile-aqueous formic acid was used to give proper separation of the six main hop bitter acids within 30 min. Further structural information about the components was acquired by collision-induced dissociation (CID). On the basis of analyses of the fragmentation patterns of the major alpha- and beta-bitter acids respectively, identification of the minor ones was performed using selected reaction monitoring (SRM) with a group of qualitatively relevant selected precursor-product ion transitions for each bitter acid in a single high performance liquid chromatography (HPLC) run. Using this technique, six minor hop acids, including "adprelupulone" observed for the first time in natural resources, were detected along with the six major acids. This hyphenated techniques provides potency for rapid qualitative determination of analogs and homologs in mixtures.

Acids↗

Influence of atmospheric pressure, outdoor temperature, and weather phases on the onset of spontaneous pneumothorax.

PURPOSE: To analyze the influence of meteorological factors such as atmospheric pressure (AP), outdoor temperature (T) changes, and weather phases (WP) on the occurrence of spontaneous pneumothorax (SP). METHODS: Retrospective study, including 659 patients with primary SP and SP associated with chronic obstructive pulmonary disease (COPD), conservatively treated in a 5-year period. In the analyzed period, 548 days with SP were compared both with 3 days preceding the onset of SP and with days without pneumothorax. The comparison was made depending on weather phases and on different aspects of AP and T. RESULTS: Seasons of the year did not significantly influence the occurrence of SP. No significant difference was found between SP and non-SP days depending on different aspects of AP and T changes. Most patients were admitted in "clusters" with not more than 2, 3, or 4 days between two successive admissions. The occurrence of SP was significantly correlated with weather phases 2ts (anticyclonic situation with warm and dry weather) and 5 hv (passing of the cold front). Biological sense and possible explanations of this correlation are discussed. CONCLUSIONS: Among all analyzed meteorological factors, significant correlation was found only between weather phases 2ts and 5hv and the occurrence of SP.

Adolescent↗

Fragmentation studies of noncovalent sugar-sugar complexes by infrared atmospheric pressure MALDI.

An investigation of sugar-sugar noncovalent complex fragmentation was conducted using a 2.94 microm Er:YAG laser for infrared (IR) atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) on an ion trap mass spectrometer (ITMS). This approach allowed the analysis of weak noncovalent complexes between a variety of biologically relevant oligosaccharides. The strength of interaction varied with different sugar structures, potentially due to varying strength of hydrogen bonding networks. In some cases, fragmentation of intramolecular sugar bonds preceded breakdown of the noncovalent complex. This result appeared primarily when complexes contained sugars with at least one sialic acid. Globotrios dimers also showed intramolecular fragmentation in preference to breakdown of the noncovalent dimer. This technique will allow further study of sugar-sugar interactions known to play a role in cellular interactions.

Atmospheric Pressure↗

Phosphate buffers in capillary electrophoresis/mass spectrometry using atmospheric pressure photoionization and electrospray ionization.

Capillary electrophoresis (CE) has been combined with atmospheric pressure photoionization (APPI) and electrospray ionization (ESI) for mass spectrometric (MS) detection. Separation conditions using potassium phosphate buffer and ammonium formate buffer have been compared for analysis of eleven pharmaceutical bases. The results showed improvements in separation efficiency and peak symmetry when phosphate buffer was used. The low flow in CE may enable utilization of these advances with MS detection. Compared with ESI, the APPI technique provided a cluster-free background. The enhanced signal-to-noise ratio in the total ion current (TIC) and the reduced spectral background indicated that the APPI process is less affected by non-volatile salts in the CE buffers. This results in a wider range of choice of CE buffers in CE/MS analysis when APPI is the ionization method.

Journal Article↗

Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of bacteriochlorophylls from Chlorobiaceae: characteristic fragmentations.

Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.

Bacteriochlorophylls↗

From fundamentals to applications: recent developments in atmospheric pressure photoionization mass spectrometry.

Only five years after the first publication on atmospheric pressure photoionization (APPI), this technique has evolved rapidly as a very useful complement to established ionization techniques for liquid chromatography/mass spectrometry (LC/MS). This is reflected in a rapidly increasing number of publications in this field. On the one hand, thorough studies into the photoionization mechanism have provided deep insights into the roles and influences of the solvent, the dopant and other additives. On the other hand, a large number of new and attractive applications have recently been introduced. New instrumental developments have resulted in combined APPI/ESI (PAESI) and APPI/APCI sources and a microfabricated APPI source. In this review, the most important developments within the field are summarized, focusing in particular on the applications of the technique.

Journal Article↗

Studies on neurosteroids. VII. Determination of pregnenolone and its 3-stearate in rat brains using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

An assay method for pregnenolone and its 3-stearate in rat brains has been developed using LC-atmospheric pressure chemical ionization (APCI) isotope dilution MS. The extraction of the rat brain homogenate containing deuterated internal standards (ISs) with organic solvent followed by silica gel mini-column chromatography gave two fractions containing pregnenolone and its 3-stearate together with the respective IS. Each fraction was derivatized into 3-acetate-20-methyloxime and 20-methyloxime, respectively, followed by silica gel mini-column chromatography to remove the excess reagents, and then each derivatized fraction was applied onto reversed-phase LC-APCI-MS. The method was applied to the determination of these steroids in the gray matter and olfactory bulbs of rat brains, which were divided into control and acute stressed specimens. Although pregnenolone in both regions of the rat brains increased more than five times after stress, its 3-stearate decreased after stress.

Animals↗