Creatine kinase isoenzymes and prostatic carcinoma: metastatic disease or acute myocardial infarction?

The measurement of creatine kinase isoenzymes, particularly the MB fraction, is a major determinant for acute myocardial infarction. Patients with metastatic carcinoma of the prostate may have an elevated serum creatine kinase-BB fraction, which by some automated laboratory techniques may be read mistakenly as creatine kinase-MB. We report such a case and discuss the creatine kinase isoenzyme measurement.

Aged↗

Commercial bacterial starter cultures for fermented foods of the future.

Starter cultures for fermented foods are today developed mainly by design rather than by screening. The design principles are based on knowledge of bacterial metabolism and physiology as well as on the interaction with the food product. In the genomics era, we will obtain a wealth of data making design on a rational basis even simpler. The design tools available are food grade tools for genetic, metabolic and protein engineering and an increased use of laboratory automation and high throughput screening methods. The large body of new data will influence the future patterns of regulation. It is currently difficult to predict in what direction the future regulatory requirements will influence innovation in the food industry. It can either become a promoting force for the practical use of biotechnology to make better and safer products, or it can be limiting the use of starter cultures to a few strains with official approval. Successful cultures based on modern technology is expected to be launched in the areas of: probiotics, bioprotection, general improvement of yield and performance for the existing culture market and probably the introduction of cultures for fermenting other food products. A scientific basis for dramatic innovations that could transform the culture industry is currently being established.

Bacteria↗

Spurious hypophosphatemia in a patient with multiple myeloma.

We report a patient with multiple myeloma and a prolonged history of hypophosphatemia who had remained asymptomatic. Extensive evaluation for a cause, including the search for a renal tubular disorder, oncogenous osteomalacia, or a parathyroid hormone (PTH)-related protein was unproductive. Renal biopsy showed no evidence of myeloma kidney. Subsequent mixing of the immunoglobulin G (IgG) fraction from the patient's serum with normal human serum, confirmed that the observed hypophosphatemia was spurious, resulting from interference of large amounts of an abnormal IgG with a standard automated laboratory assay for phosphate.

Autoanalysis↗

Accuracy, precision, and quality control for point-of-care testing of oral anticoagulation.

Oral anticoagulant (OAC) therapy is usually monitored by noting changes in a tissue factor-induced coagulation time ("prothrombin time") test on whole blood or plasma and expressed as an International Normalized Ratio (INR). Current point-of-care (POC) instruments for monitoring OAC therapy display both the calculated prothrombin time (PT) and the INR. Although many attempts have been made to improve the accuracy and precision of INR determinations in daily practice, it is impossible to eliminate all uncertainty because the PT test is sensitive to multiple factors in the patient's blood specimen. The accuracy of the average INR determined with a POC instrument depends on its calibration against reference methods. Quality control (QC) materials for POC devices are different from patients' samples and may not exactly reflect the real clinical situation. Nevertheless, internal and external QC schemes for POC devices are valuable to investigate their performance in daily practice. Calibration can be improved by direct comparison of a POC system against an established international reference preparation method. In general, the precision of the INR measured with a POC device is slightly lower than the precision achieved with available automated laboratory instruments. The greater imprecision should be weighed against the clinical advantages of a POC testing device.

Administration, Oral↗

Simulation analysis of pneumatic tube systems.

Pneumatic tube systems play an important material handling role in many hospitals. These systems are costly and complex to design and operate, yet little exists in the way of analytical methodologies for them. We present a decision support framework based on defining relevant system performance metrics, traffic analysis reporting, as well as discrete event simulation modeling. We have used this approach to analyze numerous pneumatic tubes systems in the United States and present a representative case study from a large tertiary care hospital. Our general approach can be generalized to other computer controlled hospital operational systems such as elevators, track vehicles, automatic guided vehicles, workflow enabled processes, and laboratory automation systems.

Computer Simulation↗

Massive parallelism, randomness and genomic advances.

In reviewing the past decade, it is clear that genomics was, and still is, driven by innovative technologies, perhaps more so than any other scientific area in recent memory. From the outset, computing, mathematics and new automated laboratory techniques have been key components in allowing the field to move forward rapidly. We highlight some key innovations that have come together to nurture the explosive growth that makes a new era of genomics a reality. We also document how these new approaches have fueled further innovations and discoveries.

Animals↗

An accurate and stable nitrate-selective electrode for the in situ determination of nitrate in agricultural drainage waters.

A field evaluation of a novel nitrate-ion selective electrode (ISE) was undertaken by continuous immersion over a period of 5 months in agricultural drainage weirs. The nitrate sensor N,N,N-triallyl leucine betaine was covalently attached to polystyrene-block-polybutadiene-block-polystyrene (SBS) using a free radical initiated co-polymerisation, to produce a rubbery membrane which was incorporated into a commercially available electrode body. A measurement unit was constructed comprising the nitrate-ISEs, a reference electrode and a temperature probe connected through a pre-amplifier to a data-logger and battery supply. A temperature correction algorithm was developed to accomodate the temperature changes encountered in the drainage weirs. The nitrate results obtained with the ISEs at hourly intervals compared very favourably (R2 = 0.99) with those obtained with laboratory automated chemical determinations made on contemporaneous samples of drainage in a concentration range 0.47-16 ppm nitrate-N. The ISEs did not require re-calibration and no deterioration in performance or fouling of the membrane surface was observed over four months of deployment.

Electrodes↗

Automatic continuous river monitoring of nitrate using a novel ion-selective electrode.

On-site continuous measurement of nitrate in the River Taw situated in Devon (UK) was performed automatically for two months using a recently developed ion-selective electrode (ISE). A non-submersible electrode support system was developed and a field instrument was constructed comprising the nitrate-ISEs, a reference electrode and a temperature probe connected through a pre-amplifier to a data-logger and battery supply. The nitrate-ISE was constructed using a commercially available electrode body with a membrane incorporated into the tip. This rubbery membrane contained the sensor molecule (N,N,N-triallylleucine betaine chloride, 6.5% m/m) covalently bound to polystyrene-block-polybutadiene-block-polystyrene, SBS, (43.5% m/m), with 2-nitrophenyloctyl ether (2-NPOE) as mediator (40% m/m). The Nernstian slope was -59.1 mV per decade over a linear range of 1400-0.07 mg L(-1) nitrate-N. The limit of detection was 0.007 mg L(-1) nitrate-N with a selectivity coefficient for nitrate against chloride (k(pot)NO3-, Cl-) of 3.4 x 10(-3). The speed of response was less than a minute over the linear Nernstian range. The lifetime in the laboratory exceeded 5 months with no potentiometric drift over the linear Nernstian range. A temperature correction algorithm was also used to accomodate the temperature changes encountered in the river. The river nitrate results obtained with the ISEs at hourly intervals compared very favourably (R2 = 0.9) with those obtained with laboratory automated chemical determinations made on contemporaneous river samples over a concentration range 0.55-2.00 mg L(-1) nitrate-N. The ISEs did not require re-calibration and no deterioration in performance or fouling of the membrane surface was observed during 40 days.

Automation↗

In vitro scanning saturation mutagenesis of an antibody binding pocket.

We have combined PCR mutagenesis with in vitro transcription/translation and ELISA for the rapid generation and characterization of antibody mutants. The PCR products are used directly as the template for the in vitro transcription/translation reactions and because no cloning steps are required, the in vitro saturation mutagenesis of one residue can be completed in duplicate within a week by a single investigator. In vitro scanning saturation mutagenesis was used to analyze the role and plasticity of six key contact residues (H:Tyr-33, H:Asn-35, H:Tyr-50, H:Trp-100, L:Val-94, and L:Pro-96) in the binding pocket of a single chain Fv antibody derived from the 26-10 monoclonal antibody. A total of 114 mutant antibodies were produced; all 19 substitutions at each of the 6 chosen positions. The mutants were analyzed for binding to digoxin, digitoxin, digoxigenin, and ouabain resulting in the generation of a comprehensive data base of 456 relative affinity values. Excellent agreement between the relative affinity values obtained with in vitro synthesized mutant antibodies and equilibrium affinity data obtained with previously reported purified mutant monoclonal antibodies was observed. Approximately 75% of the single amino acid mutants exhibited significant binding to one or more of the digoxin analogs. Mutations that alter and, in some cases, reverse specificity for the different digoxin analogs were identified. In vitro scanning saturation mutagenesis represents a new tool for protein structure-function and engineering studies and can be interfaced with laboratory automation so that an even higher throughput of protein mutants can be constructed and analyzed.

Binding Sites, Antibody↗

A quantitative HCV-PCR test for routine diagnostics.

The aim of this study was to develop a reliable and simple method for hepatitis C virus (HCV)-PCR using standard, automated laboratory equipment. HCV-RNA was extracted from serum and amplified in a single PCR with an internal standard. The PCR product was detected using fluoroimmunoassay. Quantification was based on external and internal standards. Linearity was observed over a wide range (10-10(7) geq). Mean inter and intra serial coefficients of variation were 35% and 23%, respectively. The limit of quantification was 1000 geq/ml based on intra and inter serial variations, while levels of 110 geq/ml were always detectable. Lower concentrations were intermittently positive. The ability to separate HCV-signals in healthy and infected persons was good, based on the distribution of HCV-signals from 353 random blood donors and 191 patient samples. To illustrate the applicability of the test, HCV-RNA quantification was performed in 11 patients during treatment with interferon alpha-2b. Ten of 11 patients showed a decline in HCV-RNA within the first few weeks of treatment. After four weeks most patients were still HCV-RNA positive but below the limit of quantification. The present method for quantification of HCV-RNA was shown to have sensitivity at the level of nested PCR techniques. Until now HCV-PCR has been complicated, time-consuming and costly, and therefore not suitable for routine diagnostics. The PCR method described here is easy to perform, fast and cost-effective.

Base Sequence↗

Eight-parameter automated hematology analyzers: comparison of two flow cytometric systems.

The performance of two high-speed 8-parameter automated hematology analyzers (Coulter Counter S-plus and ELT-8) were compared with that of reference instruments (Coulter Counter S Sr and Technicon Autocounter). The precision, linearity, and lack of carry-over of both instruments were superior over that of existing equipment. The especially noteworthy feature of the instruments was their excellent performance in the range of extreme values of both white blood cells and platelets. This enhanced performance, and the fact that all presently known relevant hematologic parameters can be measured by a single instrument on a single sample, make the contribution of these two flow cytometric-based instruments a significant advance in the field of automated laboratory medicine.

Autoanalysis↗

Computer applications for patient care--an overview.

The importance of the computer in areas of patient care is widely recognized today. This review outlines the information processing tasks which involve the interaction between the patient and the provider of health care services. These areas include the clinical laboratory, automated multiphasic health testing, medical records, patient monitoring, diagnostic support systems, and medical imaging. Health care professionals, including clinical engineers, must recognize the potential, understand basic principles, and utilize computers effectively during the next decade's rapid advances.

Computers↗

Application of robotics in blood banking.

To demonstrate the feasibility of using robots in blood banking applications several prototype systems were developed. Activities associated with sample testing and component preparation were examined. In one project, a general-purpose laboratory robot (Zymate Laboratory Automation System, Zymark, Inc., Hopkinton, Mass.) was configured to prepare samples for microplate-based ABO/Rh testing. In a second project, this same robot was configured to carry out specific steps in evaluating bar-coded labels, as part of a quality control procedure. A fluid-handling robot (Sampler 505, Tecan AG, Hombrechtikon, Switzerland) was used to prepare the dilution of serum samples for the evaluation of an anti-HTLV-III test kit. It was then configured to aspirate, dilute and dispense samples for anti-HTLV-III and HBsAg testing. This robotic system is now in field trial. The use of large industrial robots for automating component production was also considered. The key element in this design was the development of a fixture that would hold the blood bag set during the balancing, centrifugation and expressing steps. However, a fixture which was capable of performing these operations and that was equivalent in size and adaptable to a standard centrifuge bucket could not be fabricated.

Antibodies, Viral↗

Peptide aMptD-mediated capture PCR for detection of Mycobacterium avium subsp. paratuberculosis in bulk milk samples.

A peptide-mediated capture PCR for the detection of Mycobacterium avium subsp. paratuberculosis in bulk milk samples was developed and characterized. Capture of the organism was performed using peptide aMptD, which had been shown to bind to the M. avium subsp. paratuberculosis MptD protein (J. Stratmann, B. Strommenger, R. Goethe, K. Dohmann, G. F. Gerlach, K. Stevenson, L. L. Li, Q. Zhang, V. Kapur, and T. J. Bull, Infect. Immun. 72:1265-1274, 2004). Consistent expression of the MptD receptor protein and binding of the aMptD ligand were demonstrated by capturing different Mycobacterium avium subsp. paratuberculosis type I and type II strains and subsequent PCR analysis using ISMav2-based primers. The analytical sensitivity of the method was determined to be 5 x 10(2) CFU ml(-1) for artificially contaminated milk. The specificity of aMptD binding was confirmed by culture and competitive capture assays, showing selective enrichment of M. avium subsp. paratuberculosis (at a concentration of 5 x 10(2) CFU ml(-1)) from samples containing 100- and 1,000-fold excesses of other mycobacterial species, including M. avium subsp. avium and M. avium subsp. hominissuis. The aMptD-mediated capture of M. avium subsp. paratuberculosis using paramagnetic beads, followed by culture, demonstrated the ability of this approach to capture viable target cells present in artificially contaminated milk. Surface plasmon resonance experiments revealed that the aMptD peptide is a high-affinity ligand with a calculated association rate constant of 9.28 x 10(3) and an association constant of 1.33 x 10(9). The potential use of the method on untreated raw milk in the field was investigated by testing 423 bulk milk samples obtained from different dairy farms in Germany, 23 of which tested positive. Taken together, the results imply that the peptide-mediated capture PCR might present a suitable test for paratuberculosis screening of dairy herds, as it has an analytical sensitivity sufficient for detection of M. avium subsp. paratuberculosis in bulk milk samples under field conditions, relies on a defined and validated ligand-receptor interaction, and is adaptable to routine diagnostic laboratory automation.

Animals↗

Variation in plasma calcium with induced changes in plasma specific gravity, total protein, and albumin.

The relationship of plasma calcium levels to changes in plasma specific gravity, total protein, and albumin induced by venous stasis was investigated. Factors were derived for adjusting calcium results to offset the effects of variation in protein concentration and thus to make them of increased discriminatory value to the clinician. The validity of an existing specific gravity correction has been substantiated, but a more exact adjustment of 0.23 mg/100 ml of calcium for every 0.001 change in specific gravity is proposed. We recommend for automated laboratories that the factor based on albumin be used: 0.09 mg/100 ml of calcium should be subtracted from the total calcium value for every increase of 0.1 g in albumin above 4.6 g/100 ml, and a corresponding addition should be made for values of albumin below 4.6 g/100 ml.Using a calcium specific electrode, it has been shown that the ionized calcium concentration does not alter with prolonged venous stasis.

Adult↗

Immunocytometry and gene rearrangement analysis in the diagnosis of lymphoma in an idiopathic pleural effusion.

We report a patient with an idiopathic pleural effusion in whom the diagnosis of non-Hodgkin's lymphoma was established by immunocytometry of pleural fluid and confirmed by the detection of B-cell immunoglobulin gene rearrangement. Immunocytometry is a rapid, semi-automated laboratory method for phenotyping lymphoid cells by determining immunoglobulin and other cell surface antigen expression. This method defines the cell lineage (T or B cells) and the clonality (monoclonal or polyclonal) of a population of lymphocytes. The presence of a monoclonal population of lymphocytes can also be confirmed by recently developed molecular biologic techniques (e.g., Southern blotting) that provide the ability to detect rearrangements of the genes that encode either B-cell immunoglobulin proteins or T-cell antigen receptor proteins. To our knowledge, this case represents the first reported application of immunophenotypic and gene rearrangement analysis in a previously undiagnosed pleural effusion to establish the diagnosis of lymphoma. These relatively new laboratory methods may have a role in the evaluation of idiopathic lymphocytic pleural effusions.

Aged↗

Novel fluorescent technology platform for high throughput cytotoxicity and proliferation assays.

We have developed a novel fluorescent Oxygen BioSensor technology platform adaptable to many applications in the area of drug discovery and development, particularly cell-based assays. This biosensor technology requires no additional reagents or incubations, and affords continuous real-time readout of dissolved oxygen concentrations. Since the level of oxygen dissolved in an assay's medium correlates to the number and viability of the cells in the medium, this technology is ideally suited for monitoring cell viability, proliferation, or death. The technology is particularly well suited to investigating cells' kinetic responses to proliferative or toxic stimuli, such as drugs. When incorporated into a 96- or 384-well microplate format, it is compatible with standard laboratory automation systems. Here we present data illustrating the application of the Oxygen BioSensor technology for rapid, homogeneous detection and evaluation of metabolic activity of a variety of eukaryotic and prokaryotic cells, including mammalian cells, insect cells, yeast, and bacteria. In the absence of toxic substances, we find a good correlation between cell number and signal over a wide range of cell concentrations and growth times. To evaluate the usefulness of the Oxygen BioSensor for cytotoxicity assays, we have performed a series of experiments using a range of toxic agents and cell types, including both bacteria and mammalian cell lines. In a side-by-side comparison to standard MTT assays using HL60 cells, comparable IC(50) values were found with the Oxygen BioSensor for five different toxins or drugs. This assay method does not have the need for additional reagents, handling steps, or incubation periods required by the MTT assays.

Animals↗

The design and development of an integrated natural products screening database.

We designed and developed NEXUS--a new natural products screening database and related suite of software applications--to utilize the spectacular increases in assay capacity of the modern high throughput screening (HTS) environment. NEXUS not only supports seamless integration with separate HTS systems, but supports user-customized integration with external laboratory automation, particularly sample preparation systems. Designed and developed based on a detailed process model for natural products drug discovery, NEXUS comprises two integrated parts: (1) a single schema of Oracle tables and callable procedures and functions, and (2) software "front-ends" to the database developed using Microsoft Excel and Oracle Discovery/2000. Many of the back-end processing functions were written in Programming Language/Structured Query Language (PL/SQL) to provide an Application Programmer's Interface, which allows end users to create custom applications with little input from information technology professionals.

Biological Products↗