PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Calibration”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

A self calibration method using a soft clustering procedure for eye movement recordings.

A nearly automatic method for calibrating eye movement records has been developed. This very robust method is based on a soft clustering algorithm which allows exploration of the whole range of eye movement records for reliable calibration. In contrast to many other methods which carry out the calibration on several discrete points, this method is suitable for continuous determination of the transfer function of the eye movement transducer. Moreover it simultaneously uses the combined properties of vestibulo-ocular reflex, neck-to-eye reflex and smooth pursuit system to reach approximately a unity gain and zero phase lag (in subjects with no severe vestibular disorders or ocumomotor palsy). In addition, this method does not rely heavily on the degree of attention of the subject. The method is particularly suited for the calibration of non linear or noisy transducers like Electro Oculography (EOG). Calibration is performed within a few seconds. So when necessary in clinical applications it is possible to repeat calibrations frequently.

Algorithms↗

Interpretations of the TDxFLx calibration data of the abused drugs.

The useful TDxFLx calibration data was obtained for the interpretation of the interactions of the abused drugs to sheep antiserum protein. The antibody of TDxFLx calibrators was prepared from sheep antiserum. Furthermore these data can be used to interpret the abused drug-protein binding phenomena in human body and the TDxFLx screening results of the abused drugs in urine samples. TDxFLx system uses fluorescence polarization immunoassay technique that is a competitive binding immunoassay methodology to allow tracer-labeled antigen (*Drug) and patient antigen (Drug) to compete for the same binding sites on the antibody molecules of sheep antiserum. To obtain the binding parameters, binding constant (K) and number of independent binding site (n), generally, Scatchard equation is used. This Scatchard equation is expressed in the concentration terms of free drug, bound drug, and protein (antibody). The binding parameters can not be obtained by applying the TDxFLx calibration data to the Scatchard equation directly because the TDxFLx calibration data are composed of the fluorescence polarization and the total drug concentrations. To obtain the binding parameters from the TDxFLx calibration data the new useful equation which was expressed in the total concentrations of drug and fluorescence polarization should be derived. Derivation of new equation was based on the Scatchard equation. The TDxFLx calibration data was curve fitted to the derived equation using KaleidaGraph program and Macintosh computer. The binding constant (K) and the number (n(P(t))) of binding site of 11-nor-delta(9)-tetrahydrocannabinol-9-carboxylic acid (COOH.THC) on the antibody were 1.14 x 10(8)l/mole and 4.04 x 10(-7)M, respectively. The binding constant and the number (n(P(t))) of binding site of amphetamine were 5.15 x 10(5)l/mole and 2.05 x 10(6)M, respectively. In case of COOH.THC the fluorescence polarization decreased linearly with the concentration. However, in case of amphetamine or the other three abused drugs the fluorescence polarizations decreased exponentially with their concentrations.

Amphetamine↗

The tabletting machine as an analytical instrument: qualification of the measurement devices for punch forces and validation of the calibration procedures.

The quality of force measurement in an eccentric tabletting machine equipped with piezo-electric load washers mounted under pre-stress at the upper and lower punches, and the reliability of their calibration in situ and under working conditions were carefully investigated, since this tabletting machine is used as an 'analytical instrument' for the evaluation of the compression behaviour of pharmaceutical materials. For a quasistatic calibration procedure the repeatability under standard conditions and the robustness against variations in machine settings, installation conditions, equipment and handling were evaluated. Two differently constructed reference load cells equipped with strain gauges were used for the calibration of the upper punch sensor. The lower punch sensor was calibrated against the upper one. Except for a mechanical hysteresis, owing to uneven stress distribution over the piezo-electric sensors, the results of the quasistatic measurements are assessed to be satisfactory. In addition, dynamic calibrations were performed. One of the strain-gauged load cells was used in addition to two piezo-electric load washers installed without pre-stress. The dynamic behaviour of all the transducers used is deficient. While for the piezo-electric sensors a significant change in the slope of the calibration function with respect to the quasistatic behaviour was observed, for the strain-gauged load cell a pronounced hysteresis must be noted. Comparing the dynamic behaviour at different profiles of rates of force development generated by variations in machine speed and by maximum force setting, the variability in the sensitivity of the upper and lower punch piezo-electric load washers is comparatively small.

Calibration↗

Optimised procedure for the calibration of the force platform location.

An innovative optimised method, including an experiment and a mathematical model, for the calibration of the force platform location in the optoelectronic reference frame is proposed. The calibration experiment adopts a bearing-marker testing object contacting the platform and does not directly measure the platform location. The experiment is designed in order to avoid the main drawbacks possibly occurring in commonly adopted methods. The mathematical model of the experiment estimates the expected ground reaction. An optimisation algorithm identifies the optimal platform location as the one that best matches the measured outcome of the calibration experiment with the corresponding model estimate. The innovative calibration procedure has been assessed in terms of inter-tester reliability and compared with commonly used calibration procedures of platform location. These results evidenced how the introduction of such optimised procedure could improve the reliability of the calibrated platform location and, consequently, of the kinetic variables considered in posture and gait analysis.

Algorithms↗

Negative ion matrix-assisted laser desorption/ionization time-of-flight post-source decay calibration by using fibrinopeptide B.

Fibrinopeptide B (M(r) 1552.58) was employed as a calibration compound for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) post-source decay (PSD) fragment ion analysis in the negative mode. Experiments were performed by using both continuous and delayed extraction, with the maximum reflectron voltages being 30 and 21 kV, respectively. For comparison, a common positive ion PSD calibrant, ACTH(18-39) (M(r) 2466.7), was also employed with positive ion calibration constants being applied to negative ion spectra. Using fibrinopeptide B as the calibrant, the negative ion PSD results for angiotensin II (M(r) 1046.2), renin substrate tetradecapeptide (horse) (M(r) 1759.0), and the custom-synthesized peptide (K2G4)2 (M(r) 987.1) showed a factor of 1.5-2 improvement in absolute mass accuracy. Typical absolute mass-to-charge ratio accuracies were within +/- 1 Thompson and were achieved even when the peptide being analyzed was more massive than fibrinopeptide B. In addition, both calibrants showed increased accuracy when experiments were conducted in the delayed extraction mode. Other advantages of using fibrinopeptide B are its moderate cost and the ability to perform calibration and sample analysis for negative ion PSD under the same instrumental conditions.

Angiotensin II↗

Pure component selectivity analysis of multivariate calibration models from near-infrared spectra.

A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-)(1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.

Calibration↗

Microdialysis calibration using retrodialysis and zero-net flux: application to a study of the distribution of zidovudine to rabbit cerebrospinal fluid and thalamus.

A retrodialysis (RD) method for the real-time calibration of on-line microdialysis (MD) procedures was investigated in vitro and in vivo. Calibration by retrodialysis was simultaneously validated through the use of a zero-net flux (ZNF) method, which assumes directional independence of diffusion of the solute. In RD, a calibrator with dialysance (PeA; effective permeability-surface area product) similar to that of the compound of interest is introduced into the perfusate. If the calibrator is suitable, its loss from the perfusate during RD is identical to the recovery of the solute of interest determined simultaneously by normal MD. Two antiviral nucleosides (AZT and AZdU) which differ structurally by only a methylene group were utilized as solute and calibrator, respectively. Both nucleosides exhibited similar recovery and loss at flow rates of 0.5 to 5 microL/min in vitro, indicating a similar PeA product in this flow domain. Furthermore, both compounds showed similar loss into the lateral ventricle or thalamus of rabbits (n = 4) during RD at a flow rate of 1 microL/min for 6 hr. The relative loss decreased rapidly within the first hour, reaching a relatively stable value after 2 hr. The significant reduction in the loss of AZdU and AZT in vivo compared with that in vitro likely results from a lower diffusion coefficient in tissue. The distribution of AZT between plasma and cerebrospinal fluid (CSF) in the ventricle and extracellular fluid (ECF) in thalamus was determined at steady state using calibration by RD and ZNF simultaneously.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

A prototype device for standardized calibration of pulse oximeters II.

OBJECTIVE: There is no commonly accepted in vivo calibration method for pulse oximeters available up to now. On the basis of a prototype device for the calibration of pulse oximeters which was introduced recently, a second approach based on the same concept was tackled in order to design a reliable method for standardized calibration of pulse oximeters. METHODS: An extensive clinical database of time-resolved optical transmission spectra of patient fingers is used to simulate the behavior of patients. A device which is capable of playing back these spectroscopic data to pulse oximeters, and a database where the oxygen status measured with the reference method (Co-Oximetry) is stored, are the main parts of the concept. The playback device has an artificial finger as interface to the pulse oximeters and serves to collect light from the pulse oximeter for analysis and to playback simulated light to the pulse oximeter. The light intensity emitted by two LEDs which illuminates the pulse oximeter detector is controlled via a computer in such a way that it is the same as if the pulse oximeter light had passed the finger. The pulse oximeter display during the data playback can thus be compared to the true SaO2 of the patient. The device is tested with 4 pulse oximeters based on 100 patient spectra. RESULTS: For the four pulse oximeters used in this investigation, an Agilent Technologies CMS monitor (formerly Hewlett-Packard), an Ivy 2000 with Masimo Set technology and Nellcor N-3000 and N-395, there is good correlation between SPO2 and SaO2, and mean and standard deviation of in vivo SpO2-SaO2 and playback SpO2-SaO2 are in good agreement. For two instruments, Nellcor N3000 and Agilent CMS Monitor, a quantitative comparison between the in vivo and in vitro SpO, results was derived. A mean of the deviation playback vs. in vivo SpO2 is less than 0.5% SpO2. The error limits are comparable with the calibration error of the conventional calibration routine. The device is also capable of data playback even in situations with rapid desaturation changes, as displayed in Figure 2. For the other tested pulse oximeters the results are comparable. CONCLUSIONS: Compared to the first prototype the current version is simpler and less expensive in production. Many of previously existing problems are solved and the applicability to a large variety of pulse oximeters and sensors is given. The novel concept for the calibration of pulse oximeters is a tool for assessing the performance of pulse oximeters.

Calibration↗

Statistical and probabilistic approaches to confidence intervals of linear calibration in liquid chromatography.

The aim of this paper is to compare the reliability of two approaches to estimate the 95% confidence intervals of linear calibration in real situations. One is the statistical approach, which is well known in statistics, and the other is the probabilistic approach, which is based on a theory to predict the precision of instrumental analyses mainly from signal and noise, called FUMI (Function of Mutual Information) theory. The high-performance liquid chromatographic determination of quisalofop and maltose is taken as an example. Calibration lines obtained under the same experimental conditions are superimposed on the 95% confidence intervals to investigate whether the resulting confidence intervals can include all the calibration lines reasonably. A pair of 95% confidence intervals (upper and lower limits) can be calculated from each calibration line, but varies from calibration line to calibration line, although obtained under the same experimental conditions. The variability and reliability of the 95% intervals are also examined.

Calibration↗

A comparison of artificially-depleted, lyophilized coumarin and fresh coumarin plasmas in thromboplastin calibration. European Concerted Action on Anticoagulation.

Artificially-depleted lyophilized plasmas and lyophilized coumarin plasmas were prepared and compared with fresh coumarin plasmas to assess their comparative reliability in local thromboplastin calibration using the manual prothrombin time (PT) technique. Their certified PT values were inserted in turn on the vertical axis in place of the PT obtained with fresh coumarin plasmas. PT results were obtained at eight ECAA national laboratories ('test centres') and inserted on the horizontal axis. The resulting thromboplastin calibration slopes were compared with conventional fresh coumarin plasma calibration slopes at the same 'test centres'. When 60 artificially-depleted plasmas were substituted for 60 fresh plasmas, the mean calibration slopes with the human plain International Reference Preparation (IRP) were 4.2% higher. For comparison with 20 lyophilized coumarins, three sets of 20 artificially-depleted plasmas were selected in sequential order from the 60. The lyophilized coumarin plasmas gave a mean deviation of 9.6% from the fresh plasma calibration slopes compared with values of 2.0%, 6.1% and 11.7% for the three sets of 20 depleted plasmas. Although both types of lyophilized plasma calibration slopes give measurable differences from conventional fresh plasmas, these may be regarded as acceptable in clinical terms.

Blood Coagulation Tests↗

Rate responsive pacing using transthoracic impedance minute ventilation sensors: a multicenter study on calibration stability.

Previous studies showed that transthoracic impedance minute ventilation (IMV), as measured by a pacemaker sensor, is closely correlated to actual minute ventilation (VE) determined by standard methods. The aim of this study was to analyze the changes in the calibration between IMV and VE at rest and during exercise over time. Fifteen patients (age 60 +/- 13 years) with Medtronic Kappa 400 pacemakers completed a baseline visit followed by two visits separated by 1 month and 1 week, respectively. In each patient, VE (L/min) was monitored at rest in the supine and sitting positions and during graded bicycle ergometer exercise using a standard cardiopulmonary metabolic gas analysis system with simultaneous recording of IMV (omega/min) using DR-180 extended telemetry monitors. Calibration at rest was defined as the ratio of IMV to VE, calculated from 1-minute average values in the supine and sitting positions. Calibration during bicycle exercise was defined as intercept (IMV value at VE = 10 L/min-typical VE value at beginning of exercise), and slope of the IMV/VE regression line. The calibration of IMV showed individual variability over time. The magnitude (absolute value) of observed fractional changes in calibration at 1 month was 0.23 +/- 0.20 (rest-supine), 0.20 +/- 0.15 (rest-sitting), 0.18 +/- 0.19 (exercise-intercept), 0.28 +/- 0.35 (exercise-slope), and 0.18 +/- 0.15, 0.15 +/- 0.09, 0.28 +/- 0.39, and 0.27 +/- 0.15, respectively, at 1 week. The magnitude of change at 1 month was not statistically different from the magnitude of change at 1 week. In conclusion, the calibration of IMV, as measured by a pacemaker sensor, versus actual VE may demonstrate variability. However, this study also suggests that the observed changes are not cumulative over time. These results have implications for patient monitoring applications using these sensors and for development of future pacemaker rate response algorithms.

Arrhythmias, Cardiac↗

European Concerted Action on Anticoagulation (ECAA): an assessment of a method for ISI calibration of two whole blood point-of-care PT monitor systems based on lyophilized plasmas using whole blood equivalent PT.

Previously, the attempt to simplify the International Sensitivity Index (ISI) calibration of the CoaguChek Mini whole blood point-of-care test prothrombin time (PT) monitor system was successful using lyophilized plasmas from coumarin-treated patients but not with lyophilized artificially depleted plasmas. With the TAS PT-NC monitor system, both types of plasma failed to provide reliable calibrations. The present study assesses a procedure for the ISI calibration of a TAS PT-NC and CoaguChek Mini whole blood point-of-care test PT monitor systems using lyophilized plasmas. Using lyophilized artificially depleted and coumarin plasma calibrations, we have evaluated a correction for the monitor displayed PT. This was based on a 'line of equivalence' derived from the relationship between whole blood and fresh plasma PT with both types of monitor system. With the TAS PT-NC, the use of this 'line of equivalence' resulted in reliable ISI with both lyophilized coumarin and artificially depleted plasmas. There was no significant difference between mean monitor and mean reference International Normalized Ratio (INR) with the artificially depleted plasmas. With the lyophilized coumarin plasma calibrations there was only a small INR difference. Correction with the 'line of equivalence' therefore facilitates calibration of the TAS PT-NC with lyophilized plasmas. With the CoaguChek Mini, the correction based on the 'line of equivalence' did not improve results but was not required with this system.

Blood Preservation↗

Applications of the Italian protocol for the calibration of brachytherapy sources.

The Associazione Italianà di Fisica Biomedica (AIFB; Italian Association of Biomedical Physics) has adopted the Italian protocol for the calibration of brachytherapy sources. The AIFB protocol allows measurements of the reference air kerma rate, Kr, within 1.7% (1 sigma). To measure Kr the AIFB protocol has identified a direct and an indirect procedure. The direct procedure is based on the use of spherical or cylindrical ionization chambers as local reference dosimeters positioned along the transverse bisector axis of the source. Once the source is specified by a Kr value, this can be used to calibrate a field instrument, such as a well-type ionization chamber, for further source calibrations by means of an indirect procedure. This paper reports the results obtained by the Physics Laboratory of the Università Cattolica del S Cuore (PL-UCSC), in terms of Kr calibration of five types of source, 169Yb, 192Ir and 137Cs. The role of the Kr determination for a brachytherapy source has been underlined when a new source such as the 169Yb seed model X1267 has been proposed for clinical use. The Kr values for 137Cs spherical sources differed by 5% from the vendor's mean value. The five types of source calibrated in terms of Kr were used to obtain the calibration factor. NKrsource, of an HDR-1000 well-type ionization chamber.

Brachytherapy↗

Improving calibration accuracy in gel dosimetry.

A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10 x 10 cm2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (Dmax), and the other to 4.5 Gy at Dmax. The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233 +/- 0.001 s(-1) Gy(-1) and an intercept of 1.106 +/- 0.005 Gy. For higher doses, nonlinear behaviour was observed.

Acrylamides↗

Determination of absorbed dose calibration factors for therapy level electron beam ionization chambers.

Over several years the National Physical Laboratory (NPL) has been developing an absorbed dose calibration service for electron beam radiotherapy. To test this service, a number of trial calibrations of therapy level electron beam ionization chambers have been carried out during the last 3 years. These trials involved 17 UK radiotherapy centres supplying a total of 46 chambers of the NACP, Markus, Roos and Farmer types. Calibration factors were derived from the primary standard calorimeter at seven energies in the range 4 to 19 MeV with an estimated uncertainty of +/-1.5% at the 95% confidence level. Investigations were also carried out into chamber perturbation, polarity effects, ion recombination and repeatability of the calibration process. The instruments were returned to the radiotherapy centres for measurements to be carried out comparing the NPL direct calibration with the 1996 IPEMB air kerma based Code of Practice. It was found that, in general, all chambers of a particular type showed the same energy response. However, it was found that polarity and recombination corrections were quite variable for Markus chambers-differences in the polarity correction of up to 1% were seen. Perturbation corrections were obtained and were found to agree well with the standard data used in the IPEMB Code. The results of the comparison between the NPL calibration and IPEMB Code show agreement between the two methods at the +/-1% level for the NACP and Farmer chambers, but there is a significant difference for the Markus chambers of around 2%. This difference between chamber types is most likely to be due to the design of the Markus chamber.

Calibration↗

The IPEM code of practice for electron dosimetry for radiotherapy beams of initial energy from 4 to 25 MeV based on an absorbed dose to water calibration.

This report contains the recommendations of the Electron Dosimetry Working Party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a code of practice for electron dosimetry for radiotherapy beams of initial energy from 4 to 25 MeV. The code is based on the absorbed dose to water calibration service for electron beams provided by the UK standards laboratory, the National Physical Laboratory (NPL). This supplies direct N(D,w) calibration factors, traceable to a calorimetric primary standard, at specified reference depths over a range of electron energies up to approximately 20 MeV. Electron beam quality is specified in terms of R(50,D), the depth in water along the beam central axis at which the dose is 50% of the maximum. The reference depth for any given beam at the NPL for chamber calibration and also for measurements for calibration of clinical beams is 0.6R(50.D) - 0.1 cm in water. Designated chambers are graphite-walled Farmer-type cylindrical chambers and the NACP- and Roos-type parallel-plate chambers. The practical code provides methods to determine the absorbed dose to water under reference conditions and also guidance on methods to transfer this dose to non-reference points and to other irradiation conditions. It also gives procedures and data for extending up to higher energies above the range where direct calibration factors are currently available. The practical procedures are supplemented by comprehensive appendices giving discussion of the background to the formalism and the sources and values of any data required. The electron dosimetry code improves consistency with the similar UK approach to megavoltage photon dosimetry, in use since 1990. It provides reduced uncertainties, approaching 1% standard uncertainty in optimal conditions, and a simpler formalism than previous air kerma calibration based recommendations for electron dosimetry.

Advisory Committees↗

Fossil calibration of molecular clocks and the divergence times of geminate species pairs separated by the isthmus of panama.

Calibration of nucleotide sequence divergence rates provides an important method by which to test many hypotheses of evolution. In the absence of an adequate fossil record, geological events, rather than the first appearances of sister taxa in the geological record, are often used to calibrate molecular clocks. The formation of the Isthmus of Panama, which isolated the tropical western Atlantic and eastern Pacific oceans, is one such event that is frequently used to infer rates of nucleotide sequence divergence. Isthmian calibrations assume that morphologically similar "geminate" species living now on either side of the isthmus were isolated geographically by the latest stages of seaway closure 3.1-3.5 MYA. Here, I have applied calibration dates from the fossil record to cytochrome c oxidase-1 (CO1) and nuclear histone-3 (H3) divergences among six pairs of geminates in the Arcidae to test this hypothesis. Analysis of CO1 first and third positions yield geminate divergences that predate final seaway closure, and on the basis of CO1 first positions, times for all six geminates are significantly greater than 3.5 Myr. H3 sequences produce much more recent geminate divergences, some that are younger than 3.1 Myr. But H3-derived estimates for all arcid geminates are not significantly different from both 0 and 15 Myr. According to CO1, one of the two most divergent pairs, Arca mutabilis and A. imbricata, split more than 30 MYA. This date is compatible with the fossil record, which indicates that these species were morphologically distinct at least 16-21 MYA. Across all CO1 nucleotide sites, divergence rates for arcids are slower than the rates reported for other taxa on the basis of isthmian calibrations, with the exception of rates determined from the least divergent species pair in larger surveys of multiple transisthmian pairs. Rate differences between arcids and some taxa may be real, but these data suggest that divergence rates can be greatly overestimated when dates corresponding to final closure of the Central American Seaway are used to calibrate the molecular clocks of marine organisms.

Animals↗

Results of a collaborative study for fibrinogen measurement. Evidence that the use of a common calibrator improves interlaboratory agreement.

One hundred and sixty-five laboratories were asked in two different surveys to perform duplicate fibrinogen measurements on the same lyophilized plasmas by their own methods and reagents and two different methods of calibration. The between-laboratory variability, expressed as coefficient of variation (CV), and the extent of between-method and between-reagent differences were taken as a measure of agreement between measurements. It was found that the overall between-laboratory range of CV values was 9-16% and that it could be improved if a common calibrator was used. The improvement was more pronounced for the thrombin time-derived (Clauss) method (average CV reduction 43%) than for the prothrombin time (PT)-derived method (average CV reduction 12%). A satisfactory agreement was found between the PT-derived and the Clauss method for the normal-PT plasma, whereas the PT-derived was slightly higher than the Clauss method for the abnormal-PT plasmas, irrespective of calibration. There were statistically significant between-reagent differences within the Clauss method, which were reduced if the common calibrator was used. In conclusion, the results shows that a system of common calibration for fibrinogen determination improves interlaboratory agreement by reducing the CV and minimizing between-reagent differences, particularly for the Clauss method. The authors recommend manufacturers of reagents to link their calibrators to the International Standard for fibrinogen.

Calibration↗