PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Immediate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Immediate loading versus immediate provisionalization of maxillary single-tooth replacements: a prospective randomized study with BioComp implants.

PURPOSE: The aim of this prospective randomized study was to evaluate the clinical outcome of immediately loaded solid plasma sprayed (TPS) BioComp (BioComp Industries BV, Vught, The Netherlands) implants versus immediate provisionalized but non-loaded BioComp implants in the anterior and premolar region of the maxilla. MATERIALS AND METHODS: Forty-eight patients (31 females and 17 males) with a mean age of 42.3+/-13.1 years (range 19 to 78 years) were included in the study. Fifty threaded TPS implants were placed and provisionalized within 24 hours after surgery. The patients were randomly assigned to 2 groups. In the immediate loaded (IL) group (n=24) the occlusion of the provisional was designed with normal contacts in centric relation and at lateral excursions, while in the non-immediate loaded (IP) group (n=24) the provisional restoration was adjusted to clear all occlusal contacts or contacts at lateral excursions. Patients were instructed to eat a soft diet and to avoid placing food in the area of the provisional crown during the first 6 weeks. Regular clinical and radiographic controls were performed and the survival rate and implant stability quotient (ISQ) values were evaluated at delivery of the definitive restoration at 6 months. At 1 year, radiographic coronal bone defects and gingival esthetics between the 2 groups were assessed. RESULTS: Of the IL group, 2 fixtures were lost, while 3 implants were lost in the IP group. The failing implants showed increasing mobility at 2 to 3 weeks after insertion, and were removed. The remaining 45 implants were stable at every subsequent follow-up examination, and 6 months after implant placement, ISQ values were measured. The mean ISQ value in the IL group was 63.7+/-5.8 versus 63.2+/-4.3 for the IP group (P=.78). The mean mesial marginal bone loss after 12 months in the IL group was 0.27+/-0.2 mm versus 0.28+/-0.22 mm in the IP group (P=.9). The mean distal marginal bone loss after 12 months in the IL group was 0.19+/-0.15 mm versus 0.2+/-0.11 mm in the IP group (P=.87). All implants of the IL group had an ideal gingival buccal margin, versus 91% of the IP group. Full regeneration of the mesial interdental papilla was observed in 70% of the IL group versus 91% of the IP group, while full regeneration of the distal papilla was observed in 91% of both the IL and IP implants. CONCLUSION: No significant differences in ISQ mean values in radiographic bone loss and gingival esthetics were found between immediate non-loaded provisionalization and immediately loaded BioComp implants in the maxilla.

Adult↗

Immediate loading of single-tooth implants in the posterior region.

PURPOSE: The aim of this study was to evaluate the clinical response and safety of immediately loaded single-tooth implants placed in the posterior region of the maxilla and mandible. MATERIALS AND METHODS: Single-tooth implants were placed in healed extraction sites in 20 adult patients. Temporary pre-fabricated acrylic resin crowns were prepared and adjusted. The crown occlusion was adjusted to obtain minimal contacts in maximum intercuspation. After 6 weeks a ceramometal or all-ceramic crown was cemented. Radiographic and clinical examinations were made at baseline and at 3, 6, and 12 months. Cortical bone response and peri-implant mucosal responses were evaluated. RESULTS: The marginal bone level at the time of implant placement was preserved. The mean change in marginal bone level was 0.01 mm at 12 months. The mean Periotest value after 360 days was -4. The peri-implant mucosal adaptation to the anatomic form of the provisional crown resulted in a natural esthetic outcome, and a gain in papilla length was observed. One implant failure was recorded because of provisional luting cement impaction. DISCUSSION: Clinical research has shown that immediate loading is a possible treatment modality. The immediate functional loading of implants placed in this study resulted in bone adaptation to loading. A satisfactory success rate with positive tissue responses was achieved. CONCLUSIONS: The results of this limited investigation indicated that immediate loading of unsplinted single-tooth implants in the posterior region may be a viable treatment option with an esthetic outcome.

Adult↗

An immediate tooth root replacement: an implant cylinder and synthetic bone combination.

Tooth extractions in 22 cases were treated immediately with the simultaneous placement of a cylinder implant and injection of particulate synthetic bone around the neck of the implant and into the extraction socket surrounding the cylinder. Preliminary results indicate a success rate of 94.1% in those implant/synthetic bone combinations placed in function. The utilization of synthetic bone in combination with an implant creates the possibility of an immediate tooth root replacement. Besides replacing a "lost part" of the jaw immediately, this practice prevents the normal 40% to 60% bone loss that occurs in the two years post-extraction and improves both function and aesthetics for the patient. The synthetic bone, HTR Polymer, was used in combination with Steri-Oss cylinders.

Alveolar Bone Loss↗

Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study.

A clinical and radiographical study was performed to compare the outcome of oral rehabilitation in the edentulous mandible by fixed supraconstructions connected to implants installed according to either i) a 1-stage surgical procedure and immediate loading (Experimental Group-EG), or ii) the original 2-stage concept (Reference Group-RG). The EG comprised 16 subjects with edentulous mandibles. Beyond the non-smoking criteria the following specific inclusion criteria were adopted: i) all patients had to consider themselves to be in good general health, ii) the amount of bone had to enable the installation of 5-6, at least 10 mm long fixtures to be bicortically anchored (Mk II fixtures; Nobel Biocare AB, Göteborg, Sweden) between the mental foramina, and iii) the patients had to be available for the follow-up and maintenance programme. A total of 88 implants were placed in the EG (16 patients) compared to 30 in the RG (11 patients). In the EG, fixed appliances were connected to the implants within 20 days following implant installation while the fixed appliances in the RG were connected about 4 months following fixture installation. At the time for delivery of the supraconstructions all 27 patients were radiographically examined, an examination that was repeated at the 18-month follow-up. The analysis of the radiographs from the EG disclosed that during the 18-month observation period the mean loss of bone support amounted to 0.4 mm. The corresponding value observed in the RG was 0.8 mm. During the 18-month observation period no fixture was lost in any of the 2 groups examined. The implants under study as well as those in the reference material were at all observation intervals found to be clinically stable. The present clinical study demonstrated that it is, at least based on an 18-month observation period, possible to successfully load titanium dental implants immediately following installation via a permanent fixed rigid cross-arch supraconstruction. However, such a treatment approach has so far to be strictly limited to the inter-foramina area of the edentulous mandible.

Aged↗

Immediate restoration of implants placed into fresh extraction sockets for single-tooth replacement: a prospective clinical study.

The aim of the present clinical study was to evaluate the placement of transmucosal implants into fresh extraction sockets and their immediate restoration with temporary crowns. A series of 22 cases with a 12-month follow-up is presented. Twenty-two patients (15 women and 7 men; mean age 39 years) who needed a single tooth replaced because of vertical or horizontal root fracture, caries, endodontic lesions, or periodontal disease were treated with immediate postextraction implant placement. The implant was then restored with a screw-retained prosthetic restoration within 24 hours. Radiographic assessments were made at baseline and 12 months after implant placement. Clinical parameters, such as plaque score, mucositis score, probing attachment level, mucosal margin position, variation of gingival level, and variation of papilla position, were also measured at baseline and after 12 months of follow-up. At 12 months, no implants had failed. Radiographic examination revealed mean bone resorption of 0.5 mm at 12 months compared to baseline. The mean variation of gingival level, compared to the neighboring teeth, was -0.75 mm. Probing attachment levels were 0.79, 0.45, and 0.54 mm at proximal, buccal, and lingual sites, respectively. The values for the mucosal margin position were 2.9, 2.2, and 2.4 mm at proximal, buccal, and lingual sites, respectively. Regarding variation of papilla position, according to Jemt's index, 27 papillae presented with a score of 2 (61%) and 17 with a score of 3 (39%). An examination of oral hygiene and peri-implant soft tissue conditions at the 12-month follow-up visit revealed an overall frequency of plaque-carrying implant surfaces of 13%. Furthermore, mucositis (score 2) was not observed at any of the peri-implant units. Primary implant stability did not significantly increase over time. The immediate restoration of dental implants placed into fresh extraction sockets was shown to be a safe and predictable procedure. The success rate and radiographic and clinical results were comparable to those obtained following the standard protocol. Within the limits of the present investigation, immediate restoration of single-tooth implants placed in fresh extraction sockets can be considered a valuable option to replace a missing tooth. However, long-term clinical trials are needed to confirm the present results.

Adult↗

Immediate total tooth replacement.

Successful implant placement at the time of extraction has been documented. Implant placement at the time of extraction was initially performed as a two-stage procedure often with barrier membranes and sophisticated second-stage surgical uncoverings. The authors describe the next generation of this technique, including atraumatic tooth removal with simultaneous root form, implant placement, and temporization at one appointment. This technique of "Immediate Total Tooth Replacement" allows for the maintenance of the bony housing and soft-tissue form that existed before extraction, while at the same time establishing a root form anchor in the bone for an esthetic restoration.

Dental Implantation, Endosseous↗

Correlation between placement torque and survival of single-tooth implants.

PURPOSE: This study evaluated the survival parameters of single-tooth implants through clinical and radiographic analysis. MATERIALS AND METHODS: Implants were restored within a 24-hour period with a provisional crown designed to receive an occlusal masticatory load. This approach was compared to implants restored after a healing period (the control group). Forty-six implants were placed in 23 patients who were each treated with 2 Frialit-2 implants placed in sites between the second premolar in the maxilla or mandible. The manufacturer's recommended formal surgical procedure was followed, and primary stability was standardized with a minimum insertion torque of 20 Ncm. The sites were randomly selected, and the clinical and radiographic parameters were standardized with individual templates. RESULTS: Data were collected at 24 h, and at 1, 3, 6, 12, 18, and 24 months. The experimental group included 10 failed implants; 9 of the failed implants had been placed with an insertion torque of 20 Ncm. One implant from the control group failed during the 24-month follow-up period. The survival rate was independent of implant length, site position, and bone quality and quantity. Relative risk for implant failure was associated with insertion torque (relative risk 0.79 [CI: 0.66-0.930]; Cox regression) (P < or = .007), in the experimental group but was not significant for those in the control group (ie, implants placed after a healing period; relative risk 0.78 [CI: 0.34-1.78]; Cox regression) (P < or = .057). To achieve osseointegration, it was found that an insertion torque above 32 Ncm was necessary (chi2= 15.68; P < or = .004). DISCUSSION: A careful evaluation is necessary for a better understanding of the survival rates of immediately loaded implants. In this study, insertion torque was associated with the potential for risk, which can be decreased by 20% per 9.8 Ncm added. CONCLUSION: Given these results, and considering the number of patients treated, immediate provisional crowns should only be proposed with early loading if an appropriate initial insertion torque has been applied.

Adolescent↗

Immediate versus delayed loading of dental implants in the maxillae of minipigs: follow-up of implant stability and implant failures.

PURPOSE: To assess the course of the stability and the failure rate of dental implants placed in the partially edentulous maxillae of minipigs. MATERIALS AND METHODS: Three months after tooth removal, implants were placed in 9 minipigs. Six implants (XiVE; Friadent, Mannheim, Germany) were placed on each side of the posterior maxilla after preparation of the implant sites either by an osteotome technique or with spiral drills. Implant stability was assessed by resonance frequency analysis (RFA) at the time of placement, at second-stage surgery (which took place after a healing periods of 1, 2, 3, 4, or 5 months), and after a loading period of 6 months. RESULTS: Implant stability was significantly influenced by the healing period (P = .007). Implant stability decreased after 1 to 3 months of healing for both of the placement techniques and increased after a healing period of 4 months. After implant site preparation by an osteotome technique, 6 of 12 immediately loaded implants, 18 of 24 implants loaded after healing periods of 1 to 3 months, and 1 of 18 implants loaded after a healing period of 4 or 5 months were lost. After implant site preparation using spiral drills, 7 of 12 immediately loaded implants, 12 of 24 implants loaded after healing periods of 1 to 3 months, and 2 of 18 implants loaded after healing periods of 4 or 5 months were lost. Broad overlapping of confidence intervals for the number of implant failures revealed that there was no relevant difference between immediate and early functional loading for either of the 2 techniques. DISCUSSION AND CONCLUSION: Implant loading after healing periods of 1 to 3 months did not improve implant survival compared to immediate loading in the posterior maxillae of minipigs. Not until a healing period of 4 months was reached did implant stability begin to increase. Only when functional loading was started at this point in time was maximal implant survival achieved.

Analysis of Variance↗

Denture treatment needs of an overdenture population.

Cross-sectional and longitudinal studies have identified that persons wearing overdentures require regular care and maintenance of their dentures and their remaining dentition. This paper reports on a longitudinal study of the denture treatment needs of 284 dentures placed in 254 patients seen over a period of 12 years. At placement of the overdentures, baseline measurements and photographs were made by a single examiner. These measurements included evaluation of the restorations, abutment height above the gingival margin, periodontal probing depths, and oral hygiene. Denture status was evaluated by examining stability, retention, the integrity of the denture bases, and the relationship of the teeth in centric occlusion. Denture hygiene was also assessed. Based upon this examination, the subjects' denture treatment needs were determined. The majority of overdentures were well tolerated, and in general the patients were satisfied with their dentures. The most common denture treatment need was cleaning, followed by adjustment of the denture bases. Relining was a more common problem in the mandibular arch than in the maxillae. The need for occlusal adjustment did not seem to be a problem after the fifth year, but this might have been because of replacement of worn teeth or dentures. The majority of denture repairs were necessitated before the sixth year. Patients who received immediate dentures did not have greater treatment needs. Looseness of the dentures was the primary complaint, followed by sore teeth and denture-bearing tissues. In spite of their complaints, the great majority of the patients were satisfied with their overdentures.

Adolescent↗

Esthetic implant dentistry.

Consistency of results, reliability of treatment modalities, and long-term prognosis require scientific approaches to therapeutic procedures. Reliable and unbiased information rooted in academics and research assist the health care professional use current technology to develop the best course of action to restore or enhance the best esthetic outcome for the patient. Without anticipating potential failure, any immediate success is limited to initial satisfaction while ignoring the far greater elements of a future problematic outcome. This article proposes procedures for soft and hard tissue preservation, repair, or reconstruction in esthetic implant dentistry and emphasizes that an essential prerequisite to effective esthetic therapy is the establishment of a complete and accurate diagnosis.

Alveolar Bone Loss↗

[Immediate implantation. Preservation of bone volume and osseous regeneration].

In recent years, much emphasis has been placed on the refinement and enhancement of prosthetic components and techniques in implant dentistry, while the surgical protocol has remained fairly constant. The evolution of the concept of the immediate placement of fixtures into extraction sites, along with the related concept of guided tissue regeneration, is a major advancement in the surgical field. It provides significant benefit to both patient and clinician in terms of the reduced treatment time and an enhanced prognosis related to biomechanics and aesthetics.

Alveolar Bone Loss↗

The Umgeni bridge, a resin bonded pontic using a preformed fibre post an aesthetic procedure of low biological and fiscal cost.

A missing anterior tooth or open embrasures destroys the aesthetics of a smile. The replacement of a missing anterior tooth is one of the most rewarding and challenging aspects of restorative dentistry. There are a number of techniques to do this, however, most involve the use of a technician, which means additional cost to the patient and multiple visits. In today's financial climate with practice expenses climbing and medical aid remuneration dwindling, one must seek methods to reduce costs and provide patients with more affordable dentistry. In addition, in crisis situations such as the traumatic loss of a tooth an immediate replacement technique albeit temporary is necessary. To replace a missing anterior tooth directly and immediately presents a rewarding challenge to the clinician. The Umgeni bridge named after the river that flows on the north side of Durban, is particularly useful in replacing congenitally missing laterals after completion of orthodontic treatment in the case of congenitally missing laterals and cleft palates.

Acid Etching, Dental↗

Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial.

BACKGROUND: Immediate loading of osseointegrating implants shortens the treatment time and makes it possible to give the patient an esthetic appearance during the whole treatment period. A previous retrospective clinical study showed a success rate of 94.2% after 1 year of immediate loading of fixed partial constructions in the maxilla supported by machined-surface implants. The recently introduced Brånemark System TiUnite (Nobel Biocare AB, Gothenburg, Sweden) surface has been shown to better maintain primary implant stability and to help achieve secondary stability earlier compared with the machined surface. PURPOSE: The aim of the present study was to compare TiUnite and machined-surfaced Brånemark System implants when applying immediate loading of partial fixed bridges in the posterior mandible. MATERIALS AND METHODS: Forty-four patients were randomized for test and control therapy. In the test group, 22 patients received 66 Brånemark System TiUnite surface implants supporting 24 fixed partial bridges, all of which were connected on the day of implant insertion. In the control group, 22 patients received 55 Brånemark System machined-surface implants supporting 22 fixed partial bridges, which also were connected on the day of implant insertion. All constructions were two- to four-unit bridges. Bone quality and quantity were assessed. Radiographic examinations were performed on the day of surgery/loading and at the 1-year follow-up visit. RESULTS: Three TiUnite and eight machined-surface implants failed during the first 7 weeks of loading. This resulted in a cumulative success rate of 95.5% for TiUnite surface implants after 1 year of prosthetic load in the posterior mandible. The corresponding cumulative success rate for machined-surface implants was 85.5%. When using the machined-surface implants, the number of failed implants was significantly higher in smokers and in bone quality 4 sites. Such findings were not seen with the use of TiUnite implants, despite the fact that there were more smokers and more implants placed in bone quality 4 in this group. The marginal bone resorption after 1 year of loading was on average 0.9 mm (SD 0.7 mm) with the TiUnite implants and 1.0 mm (SD 0.9 mm) with the machined implants. CONCLUSIONS: The present study demonstrated a 10% higher success rate following immediate loading of partial fixed bridges in the posterior mandible supported by TiUnite surface implants compared with success with machined implants. When using the machined implants, the number of failed implants was significantly higher in smokers and in bone quality 4 sites. Such findings were not seen following the use of TiUnite implants.

Adult↗

Immediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up.

BACKGROUND: Immediate implant function is a psychological benefit for the patient and makes a substantial reduction in treatment cost possible. Currently, immediate function using Brånemark implants has become an accepted alternative for complete-arch fixed restorations in mandibles and for overdenture support for some other screw-shaped implants. Clinical documentation is lacking for other applications. PURPOSE: The purpose of this study was to investigate a concept for immediate function of Brånemark implants supporting fixed prosthesis in the esthetic regions of the jaws. MATERIALS AND METHODS: This retrospective clinical study included 49 consecutively treated patients with 94 implants supporting 54 fixed prostheses, all in esthetically critical regions: 23 of the prostheses were bridges, 14 in maxillae and 9 in mandibles; 31 of the prostheses were crowns, 22 in maxillae and 9 in mandibles. At surgery, the implant platform was positioned above the surrounding bone level and bicortical anchorage was the goal whenever possible. The minimum insertion torque for accepting the implant for immediate function was 32 Ncm. Provisional implant-supported prostheses without occlusal contacts were delivered at time of surgery, and final prostheses with normal occlusion were delivered 5 months later. RESULTS: Eighty-five of the implants (90%) have passed the 1-year and 40 (43%) the 2-year follow-ups, respectively. Two implants failed in one patient before the 6-month follow-up, and another two implants between the 6-month and the 1-year follow-up, in two other patients, giving a cumulative survival rate of 96%. The average bone resorption was 0.8 mm after the first year as evaluated from 35 patients with readable radiographs. The failed implants were replaced after 3 to 4 months with immediate function; these were successful in all cases (not included in this study). The number of complications was small and did not differ in character from those normally encountered at implant treatment using a conventional protocol. CONCLUSIONS: The cumulative survival rate of 96% at 1 and 2 years indicates that immediate function of Brånemark implants used in the esthetic zone in both jaws can be a viable concept. All failures occurred in fresh extraction sites, and extra care is recommended to avoid situations with ongoing inflammation in these situations.

Adolescent↗

Changes in crestal bone levels for immediately loaded implants.

PURPOSE: The authors' objective was to measure crestal bone level change in subjects with immediately loaded implants and to identify risk factors associated with changes in bone level. MATERIALS AND METHODS: A retrospective cohort study design was used. The sample comprised subjects who had had endosseous implants placed and immediately loaded between July 2001 and July 2003. Demographic, health status-related, anatomic, implant-specific, prosthetic, and surgical variables were examined. The primary outcome variable was change in crestal bone level over time. Appropriate uni-, bi-, and multivariate statistics were computed. RESULTS: The sample comprised 174 subjects who received 347 immediately loaded implants. The mean duration of radiographic follow-up was 6.9 +/- 4.0 months, respectively. Mean changes in radiographic bone level were -0.5 mm and -0.6 mm on the mesial and distal surfaces, respectively, after a mean of 6.9 months of radiographic follow-up. Using least squares methods, it was estimated that radiographic bone levels would be -1.0 mm and -0.8 mm on the mesial and distal surfaces, respectively, at 12 months. The multivariate model revealed that radiolucency at or adjacent to implant site was associated with an increased risk of crestal bone loss (odds ratio, 1.88; 95% CI, 1.00 to 3.60). Twelve months after placement, 92.5% of implants had had < or = 1.5 mm of crestal bone loss. DISCUSSION: The results of this study were comparable to the results of other studies comparing immediate loading to delayed loading. Further research to estimate long-term changes in crestal bone loss and to identify risk factors for bone loss with immediate loading is recommended. CONCLUSION: This study suggests that crestal bone level changes with immediately loaded implants were within the recommended range for 92.5% of the evaluated implants. The mandible showed a higher risk for crestal bone loss compared to the maxilla.

Adolescent↗

Early loading of sandblasted, acid-etched implants in the posterior maxilla and mandible: a 1-year follow-up report from a multicenter 3-year prospective study.

PURPOSE: The aim of the present study was to evaluate the concept of an immediate loading protocol in the posterior maxilla and mandible through analysis of implant survival at 1 year. MATERIALS AND METHODS: One year follow-up data of a multicenter study are reported. Eighty-two ITI sandblasted, acid-etched (SLA) implants in 40 patients were loaded between 0 and 11 days after implant placement (mean 4.3 +/- 2.8 days). The restorations consisted of either 2 splinted crowns or a 3-unit fixed prosthesis. All restorations were put into full functional occlusion. Periapical radiographs were evaluated for changes in crestal bone level from baseline to 1 year postloading. Primary stability of the implants was checked initially and before the fitting of the definitive prosthesis. The restorations were evaluated by the practitioners for retention, stability, and esthetics. RESULTS: Three patients' implants were not loaded because of lack of primary stability, and a fourth patient was excluded from the study because of a protocol violation (more than 4 implants were used). All 4 patients were successfully treated outside the protocol. The overall survival rate of the remaining implants at 1 year was 98.8%. The mean bone loss at 1 year was 0.52 +/- 0.98 mm, which is within the reported limits of less than 1 mm (range 0.4 to 1.4 mm) loss in the first year. DISCUSSION AND CONCLUSION: The early results from this study indicate that early and immediate loading of 2 implants in the posterior maxilla and mandible may be suitable in selected patients. On the basis of 1 year of observation, the results appear similar to those achieved with a delayed procedure.

Adult↗

An immediate adhesive bridge using the natural tooth.

There are several methods available for the replacement of missing anterior teeth. These include a removable prosthesis, a conventional fixed bridge, an adhesive bridge or a dental implant. The choice of the most suitable technique depends on several factors, such as the condition of the adjacent teeth, the occlusion, the patient's wishes and the financial implications of the proposed treatment.

Acid Etching, Dental↗

Immediate and early function of Brånemark System implants placed in the esthetic zone: a 1-year prospective clinical multicenter study.

BACKGROUND: Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. PURPOSE: The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. MATERIALS AND METHODS: Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. RESULTS: Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. CONCLUSIONS: The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor to premolar regions in both jaws is a viable concept. More failures occurred with single-tooth replacements (6.3%) than with splinted implants (1.9%).

Adolescent↗