PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Detection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Sensitive, universal detection for capillary electrochromatography using condensation nucleation light scattering detection.

Condensation nucleation light scattering detection (CNLSD) was coupled with a pressurized capillary electrochromatography (pCEC) system using an electrospray interface. Supplementary pressure from a high-pressure pump was used to stabilize the electrospray and electrochromatography processes. Hydrodynamic injections were made with a 20 nl injection valve, and the inherent dead volume from the valve was successfully minimized, such that plate numbers in the range of 120,000 to 350,000/m were observed. Selectivity tuning using both pressure and voltage with the pressurized capillary electrochromatography system was demonstrated. Good reproducibility, comparable sensitivities for a wide range of compounds, including carbohydrates, and limits of detection down to the 50 ng/ml level, corresponding to 1-2 pg levels, were determined without the need for derivatization, demonstrating that condensation nucleation light scattering detection is a sensitive, universal detection method for pressurized capillary electrochromatography.

Carbohydrates↗

High frequency of constitutive alkali-labile sites in mouse major satellite DNA, detected by DNA breakage detection-fluorescence in situ hybridization.

DNA breakage detection-fluorescence in situ hybridization (DBD-FISH) is a new procedure for detecting and quantifying DNA breaks and alkali-labile sites in single cells. Cells trapped within an agarose matrix are deproteinized and treated with an alkaline unwinding solution that transforms DNA breaks and alkali-labile sites into single-strand DNA (ssDNA) motifs starting from the end of the break. These ssDNA motifs are susceptible to being hybridized with whole genome or specific DNA probes, and detected using current FISH procedures. As DNA breaks increase in a target region, more ssDNA is produced and more DNA probe hybridizes, thus increasing the FISH signal, which may be captured and analyzed using a digital image analysis system. This increase can be reflected in the surface area, mean and whole fluorescence intensity of the signal. When intact mouse splenocytes were processed with this technique using a whole genome probe, a very strong background signal was evident when compared with human blood leukocytes. In fact, when using 0.03M NaOH as the alkaline unwinding solution at 22 degrees C for 2.5min, the whole fluorescence intensity from mice cells was 50 times higher than that from human cells, thus suggesting the existence of a high frequency of constitutive alkali-labile sites in the DNA from mouse cells. Furthermore, when alkaline unwound mouse cells were simultaneously hybridized with the whole genome probe (FITC-revealed, green) and a major satellite DNA probe (Cy-3-labeled, red) both signals appeared co-localized. This result demonstrates that the high frequency of constitutive alkali-labile sites detected in the mouse genome is mainly located in the major satellite DNA sequences, resembling the findings from human 5bp classical satellite DNA sequences.

Alkalies↗

Detection of P-glycoprotein in cell lines and leukemic blasts: failure of select monoclonal antibodies to detect clinically significant Pgp levels in primary cells.

Multidrug resistance (MDR) is a salient feature of chemotherapy failure in pediatric patients. One of the most common and well-studied mechanisms implicated in causing MDR is P-glycoprotein (Pgp), an ATP-dependent, transmembrane drug efflux pump. Accurate and reproducible detection of this MDR protein is necessary as it may have important clinical implications. In this study comparing the directly conjugated anti-Pgp monoclonal antibodies UIC2-PE and 15D3-PE to the unconjugated anti-Pgp mAb MRK16, we analyzed cell lines, normal peripheral blood cells, and bone marrow cells from pediatric patients diagnosed with acute myeloid leukemia and acute lymphoblastic leukemia; all samples were also analyzed for Pgp function using rhodamine 123 in order to correlate results from antibody staining with functional activity. For all patient samples evaluated, only MRK16 correlated well with the rhodamine 123 assay. Both the directly conjugated antibodies UIC2-PE and 15D3-PE failed to detect Pgp in almost all cases. Pre-treatment of cells with neuraminidase did not provide a consistent enhancement of antigen detection. Based on these results, we suggest that while UIC2-PE and 15D3-PE may be able to detect the very high levels of Pgp expressing laboratory-cultured cell lines, they are not suitable for clinical application in their currently available conjugated form. When assaying patient samples for Pgp expression and function using flow cytometry, the rhodamine 123 functional assay should be performed in concert with staining with MRK16.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Optimisation of the polymerase chain reaction and dot-blot hybridisation for detecting cytomegalovirus DNA in urine: comparison with detection of early antigen fluorescent foci and culture.

Rapid, sensitive and specific assays are required for the diagnosis of CMV infection following transplantation. We describe our experience in developing assays for detecting CMV in urine. Conventional preparation of probes cloned after amplification in E. coli led to contamination with E. coli nucleic acids; these hybridised to E. coli DNA present in urine and produced false positive results. Two CMV probes (Hind III and gL) hybridised to human DNA despite high stringency; these probes were thus unsuitable for detecting viral nucleic acids in clinical samples. A PCR derived probe from the immediate early gene of CMV detected dot-blotted CMV DNA specifically. Optimal preparation of urine for detection of CMV DNA was as follows; four freeze/thaw cycles and ultracentrifugation before in vitro proteinase K/SDS treatment, phenol:chloroform extraction, heat denaturation and direct application onto a nylon membrane. However, dot-blot hybridisation was a poor test for CMV in urine; it had low sensitivity and specificity compared with virus isolation and DEAFF. Single round PCR of a 293 bp region of CMV DNA was sensitive and specific to CMV targets. However, undiluted urine contained PCR inhibitors that could only be partly removed by using PEG precipitation. PCR of CMV DNA from urine was specific but was insensitive compared to conventional culture and DEAFF. A significant proportion of urine samples were toxic in conventional culture and DEAFF tests but, PCR of CMV DNA from urine is insensitive and despite its specificity is unlikely to be advantageous in clinical practice even when DEAFF or culture prove unreliable.

Antigens, Viral↗

[Differential traits of prostatic cancer detected through an early screening program versus the one detected during urologic consultation].

OBJECTIVE: To compare some features of prostate cancers (PCa) detected in a screening program, versus cancers diagnosed in an outpatient clinic. MATERIAL AND METHODS: Retrospective study of 393 patients with biopsy evidence of PCa: 93 (23.7%) from a screening campaign, and 300 (76.3%) detected in an outpatient Urology clinic. Features studied at the moment of diagnosis were age, PSA, digital rectal examination (DRE), transrectal ultrasound (TRUS) characteristics and volume stimation, PSA density (PSAD), clinical stage and Gleason score. A comparison was established between the two groups of patients taking into account the mentioned parameters. RESULTS: A higher age, PSA and DPSA values were found among cancers detected out of the screening program. A greater probability of abnormal DRE and a more advanced clinical stage was also noted. In the screening group, 78.5% of the cancers were localized and 8.6% metastatic. In the outpatient clinic group, the proportions were 50.7% and 26%, respectively. No differences were found with respect to TRUS findings, prostate volume, or Gleason score. CONCLUSIONS: Cancers detected in screening programs are found in earlier stages. Nevertheless, results from long term randomized studies are necessary to verify if these data really mean that a disease-specific mortality reduction can be achieved.

Aged↗

Comparison of LC detection methods in the investigation of non-UV detectable organic impurities in a drug substance.

HPLC Analysis with different detection methods was shown to be essential in the separation and identification of unknown organic impurities in a drug substance. The impurities were found to exhibit very weak or no response to standard ultraviolet (UV) absorption detection. LC-MS, LC-NMR, indirect, refractive index and evaporative light-scattering detection were used to quantify and identify the impurities in this specific case. The drug substance studied was found to be an ideal analyte for demonstrating the advantages and limitations of several chromatographic detection systems for impurity profile analysis.

Chromatography, High Pressure Liquid↗

Comparative evaluation of the MB/BacT and BACTEC 460 TB systems for the detection of mycobacteria from clinical specimens: clinical relevance of higher recovery rates from broth-based detection systems.

New broth-based detection systems have higher recovery rates of mycobacteria from clinical specimens than traditional cultures on solid media. The clinical significance of this higher sensitivity rate is largely unknown. We prospectively evaluated the performances of two liquid media detection systems (the MB/BacT system and the BACTEC 460 TB system) and an egg-based Lowenstein-Gruft solid medium (LG) on the recovery rates of mycobacteria from 849 clinical specimens. Mycobacteria (other then M. gordonae) were detected in 51 (6.0%) specimens. In 12/51 (23%) specimens, mycobacteria (five mycobacterium tuberculosis (MtB) and seven non-M tuberculosis complex (MOTT) were recovered only from the broth-based systems. Review of the patients' clinical charts revealed that failure of LG to recover Mtb were due to nonmycobacterial overgrowth and antibiotic treatment. The recovered MOTT were all clinically nonsignificant. Higher sensitivity of broth-based mycobacteria detection systems is largely due to their capability to recover mycobacteria from treated tuberculous patients or from partially decontaminated specimens. The high recovery rates of nonclinically significant MOTT could potentially increase inappropriate use of antibiotics.

Bacterial Typing Techniques↗

Application of nested PCR and mass spectrometry for DNA-based virus detection: HBV-DNA detected in the majority of isolated anti-HBc positive sera.

DNA preparations from three different groups of serum samples were examined for HBV-DNA via a nested polymerase chain reaction assay (lower detection limit: 10 viral genomes in 100 microliters serum): Group I consisted of 11 uninfected control sera, group II consisted of sera obtained from 11 HBV infected patients and group III consisted of 21 isolated anti-HBc positive samples. The 21 samples from group III were HBV-DNA negative according to a conventional non-nested PCR assay and hybridization with a 32P-labelled probe. Using nested PCR and mass spectrometry, HBV-DNA was detected in none of group I and in all of group II samples. In 11 out of 21 (52%) of the isolated anti-HBc positive sera from group III, HBV-DNA was detected. No correlation was observed between HBV-DNA positivity and anti-HBc titers. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry provided a fast, sensitive and non-radioactive assay for the detection of PCR products without the need for gel electrophoresis or hybridization with labelled probes.

DNA, Viral↗

Detection of HER-2/neu gene amplification in breast cancer using a novel polymerase chain reaction/ligase detection reaction technique.

BACKGROUND: Gene amplification is the primary mechanism of HER-2/neu overexpression in breast cancer and is a strong predictor of prognosis. Currently screening for HER-2/neu gene amplification in breast cancer is done by fluorescent in-situ hybridization (FISH), which is accurate but costly and labor intensive. We have evaluated a new PCR (polymerase chain reaction)-based assay for the detection of HER-2/neu gene amplification in human breast cancer. STUDY DESIGN: A total of 15 breast cancer cell lines and 14 breast cancer specimens were evaluated. HER-2/neu status of the tumors was evaluated by FISH and then assessed using a quantitative polymerase chain reaction/ligase detection reaction (PCR/LRD) technique. RESULTS: Amplification of the HER-2/neu gene was detected in seven cell lines previously reported to have amplification and no amplification was found in any of the six that had been reported not to have amplification. In the assessment of breast specimens the PCR/LDR and FISH assays were in complete agreement. All 10 tumors with amplification by FISH were also amplified by PCR/LDR. CONCLUSIONS: The PCR/LDR technique successfully detects HER-2/neu gene amplification in clinical breast cancer specimens and shows 100% concordance with FISH. This technique is an accurate and rapid alternative to FISH with the potential for automation and high throughput analysis of HER-2/neu status in breast cancer.

Breast Neoplasms↗

In vivo microdialysis in the visual cortex of awake cat. II: sample analysis by microbore HPLC-electrochemical detection and capillary electrophoresis-laser-induced fluorescence detection.

Sampling and monitoring release of excitatory and inhibitory amino acids in the striate cortex of mammals will provide important information for visual system research. Two microbore high performance liquid chromatography-electrochemical detection methods and a capillary electrophoresis-laser induced fluorescence detection were developed to determine the inhibitory amino acid, gamma-aminobutyric acid and the excitatory amino acids, glutamate and aspartate in microdialysates of cat striate cortex. In the liquid chromatography method, samples were derivatized using OPA-TBT. Ten microliters of derivatized product was injected onto the microbore column (100 x 1 mm i.d., C8) for quantitative analysis. Electrochemical detection was employed. In the capillary electrophoresis method, samples were derivatized using fluorescein isothiocyanate and separated in borate buffer within 15 min, then detected by a laser-induced fluorescence detector.

Amino Acids↗

Automated large-volume sample stacking procedure to detect labeled peptides at picomolar concentration using capillary electrophoresis and laser-induced fluorescence detection.

We have developed an automated large-volume sample stacking (LVSS) procedure to detect fluorescein isothiocyanate-labeled peptides in the picomolar range. The injection duration is 10 min at 50 mbar to fill 62% of the capillary volume to the detection cell. The calculated limit of detection (S/N=3), filling 1% of the capillary volume, is 74 pM for bradykinin and 45 pM for L-enkephalin with samples diluted in water and analyzed in a 50 mM borate buffer, pH 9.2. With the automated LVSS system, the limits of detection are 7 pM for bradykinin, 3 pM for L-enkephalin and 2 pM for substance P. LVSS is shown to be quantitative from 500 to 10 pM.

Automation↗

The diagnosis of malaria infection using a solid-phase radioimmunoassay for the detection of malaria antigens. Application to the detection of Plasmodium berghei infection in mice.

A method has been devised to show that malaria parasites can be detected serologically in infected blood with a high degree of sensitivity. Using a murine malaria model, parasites were demonstrated in a solid-phase radio-immunoassay which measured antibody-binding inhibition. Lysed red blood cells (r.b.c.) were incubated with labelled specific antibody and were then reacted in antigen-coated tubes. The degree of inhibition of antibody binding in the tubes correlated with the level of parasitaemia in the test blood. Using homologous antisera the test detected infection at a level of 1 parasite/million r.b.c. The specificity of the method was shown by comparison of antibody-binding inhibition in normal and infected r.b.c. and in r.b.c. from non-infected mice with induced reticulocytosis. The sensitivity was shown in vitro in tests of serially diluted blood of high parasitaemia and in vivo for the detection of early infection. The presence of antibody in the test blood did not significantly affect the sensitivity of parasite detection.

Animals↗

Detection and evaluation of fragrances by human reactions using a chemical sensor based on adsorbate detection.

Human reactions and sensor responses to 37 typical fragrances are investigated in order to develop a chemical sensor which can detect fragrances and evaluate them in subjective terms of human reactions. Eight female test subjects recorded their reactions to these fragrances by grading them on a seven-point scale in terms of 55 descriptive characteristics. Their reactions fell into two general categories, "pleasantness" and "freshness (elegance)", dependent on the characteristic chemical structure of the fragrances. The women evaluate the fragrances mainly by the degree of pleasantness and freshness (elegance). A set of eight plezoelectric sensors incorporating different hydrophobic polymer materials is fabricated to predict such human reactions because their adsorbate detection and pattern recognition are similar to those in humans. The sensors were effective in detecting hydrophobic fragrances in the gas phase, and their fragrance classifications were similar to human ones. The sensor responses to the adsorbate correlate significantly with two of the human responses with multiple correlation coefficients of more than 0.6 (p < 0.02). Namely, the sensor can predict two different human reactions to fragrances simultaneously, suggesting the possibility of developing an artificial olfactory sensor based on adsorbate detection.

Adsorption↗

Near-field thermal lens detection at 257 nm as an alternative to absorption spectrometric detection in combination with electromigrative separation techniques.

A device is presented that permits detection of analytes absorbing electromagnetic radiation at lambda = 257 nm (in fused-silica capillaries with 75-microm i.d.) via the near-field thermal lens effect. The detector was realized by using a frequency-doubled argon ion laser as pump laser and a laser diode (emission wavelength, 633 nm) coupled into a monomode optical fiber as probe laser. Comparing the performance of this detector to the performance of a commercial absorption spectrometric detector working at lambda = 257 nm equipped with a unit for on-column detection in fused-silica capillaries showed a substantial improvement in detection limits (up to 30-fold improvement) for the near-field thermal lens detector (NF-TLD). The feasibility of the NF-TLD for sensitive detection of nonfluorescent analytes in real samples after separation by micellar electrokinetic chromatography was shown taking the determination of nitroaromatic compounds in contaminated water from a former ammunition plant as an example. Dependence of the thermal lens signal on pump laser power, velocity of the mobile phase, and chopper frequency was investigated. A linear calibration range over 2 orders of magnitude was obtained.

Journal Article↗

Application of disorganized monolayer films on gold electrodes to the prevention of surfactant inhibition of the voltammetric detection of trace metals via anodic stripping of underpotential deposits: detection of copper.

Development of an approach to prevention of electrode surface fouling by surfactants in samples is demonstrated. Spontaneously adsorbed monolayer systems employing short alkyl chains and bulky end groups are used to form porous disorganized monolayers on gold electrodes. Detection of copper by stripping of underpotential deposits formed at electrodes modified with disorganized films of mercaptoethanesulfonate (MES), mercaptopropanesulfonate, mercaptoacetic acid, and mercaptopropanoic acid was possible, and to a much lesser extent at aminoethanethiol and L-cysteine films. Use of short deposition times in conjunction with linear sweep anodic stripping voltammetry allowed detection of Cu2+ ions down to 1 x 10(-6) M in sulfuric acid solution, using underpotential deposition as the deposition step of the procedure. Calibration graphs were linear in the concentration range (1-80) x 10(-6) M Cu2+ using 15-s deposition at 0.00 V versus Ag/AgCl. The surfactants Tween 20, Tween 80, and Triton X-100 were found to have no affect on detection of Cu2+ ions in the calibration curve concentration range using MES-modified gold electrodes, whereas at unmodified gold electrodes very severe attenuation of the detection capability was manifested. The average slope for all calibration curves at the MES-modified electrode in the absence and presence of the surfactants at two different concentration levels was 0.0710 +/- 0.0024 microA microM(-1); in contrast, the slope of the calibration line at uncoated gold electrodes in the presence of surfactant was 0.0268 microA microM(-1). These results indicate the excellent ability of a disorganized, porous monolayer for prevention of fouling of the electrode surface by the surfactants.

Journal Article↗

Development of a micro total analysis system incorporating chemiluminescence detection and application to detection of cancer markers.

We developed a micro total analysis system (mu-TAS) incorporating chemiluminescence detection, in which the chemiluminescence reaction of isoluminol isothiocyanato (ILITC) (as a chemiluminescence reagent for labeling)-microperoxidase (as a catalyst)-hydrogen peroxide (as an oxidant) was adopted. The analysis system performed the following three processes on a microchip: immune reaction for high selectivity, electrophoresis for formation and transportation of the sample plug, and chemiluminescence detection for high sensitivity. The three processes were compactly integrated onto the microchip to give the mu-TAS. The microchip contained two microchannels that crossed at an intersection, while the ends of the microchannels accessed four reservoirs. As the first process, the immune reaction was performed using an antibody-immobilized glass bead. The glass bead was placed in one of the reservoirs along with antigen (analyte) and a known amount of ILITC-labeled antigen to set up a competitive immune reaction. For electrophoresis, as the second process, the reactant after the immune reaction was fed electrophoretically into the intersection resulting in a sample plug. The sample plug was then moved into another reservoir containing hydrogen peroxide solution. At this point, chemiluminescence detection was performed as the third process: the labeled antigen mixed with the hydrogen peroxide and the catalyst included in the migration buffer to produce chemiluminescence. Chemiluminescence was detected by a photomultiplier tube located under the reservoir. The mu-TAS described here was capable of determining, with high selectivity and sensitivity, human serum albumin or immunosuppressive acidic protein as a cancer marker in human serum.

Biomarkers, Tumor↗

Ligase detection reaction/hybridization assays using three-dimensional microfluidic networks for the detection of low-abundant DNA point mutations.

We have fabricated a flow-through biochip assembly that consisted of two different microchips: (1) a polycarbonate (PC) chip for performing an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using an universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for the LDR in a continuous-flow format, in which two primers (discriminating primer that carried the complement base to the mutation being interrogated and a common primer) that flanked the point mutation and were ligated only when the particular mutation was present in the genomic DNA. The miniaturized reactor architecture allowed enhanced reaction speed due to its high surface-to-volume ratio and efficient thermal management capabilities. A PMMA chip was employed as the microarray device, where zip code sequences (24-mers), which were complementary to sequences present on the target, were microprinted into fluidic channels embossed into the PMMA substrate. Microfluidic addressing of the array reduced the hybridization time significantly through enhanced mass transport to the surface-tethered zip code probes. The two microchips were assembled as a single integrated unit with a novel interconnect concept to produce the flow-through microfluidic biochip. A microgasket, fabricated from an elastomer poly(dimethylsiloxane) with a total volume of the interconnecting assembly of <200 nL, was used as the interconnect between the two chips to produce the three-dimensional microfluidic network. We successfully demonstrated the ability to detect one mutant DNA in 100 normal sequences with the biochip assembly. The LDR/hybridization assay using the assembly performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time 19.1 min) and could screen multiple mutations simultaneously.

Base Sequence↗

13C direct detected NMR increases the detectability of residual dipolar couplings.

13C direct detection is becoming an increasingly efficient approach to identify signals of residues that escape detection in 1H detected experiments. Pulse sequences have been developed to obtain 1H partially recoupled experiments for the measurement of the 1JHalphaCalpha and 1JHN couplings with the same resolution available in conventional 1H detected experiments. A consistent set of backbone rdc obtained without any 1H-based experiment has been obtained and shown to be effective for protein solution structure determination.

Calbindins↗