Linear excitation schemes for IR planar-induced fluorescence imaging of CO and CO2.

A detailed discussion of linear excitation schemes for IR planar-induced fluorescence (PLIF) imaging of CO and CO2 is presented. These excitation schemes are designed to avoid laser scattering, absorption interferences, and background luminosity while an easily interpreted PLIF signal is generated. The output of a tunable optical parametric amplifier excites combination or overtone transitions in these species, and InSb IR cameras collect fluorescence from fundamental transitions. An analysis of the dynamics of pulsed laser excitation demonstrates that rotational energy transfer is prominent; hence the excitation remains in the linear regime, and standard PLIF postprocessing techniques may be used to correct for laser sheet inhomogeneities. Analysis of the vibrational energy-transfer processes for CO show that microsecond-scale integration times effectively freeze the vibrational populations, and the fluorescence quantum yield following nanosecond-pulse excitation can be made nearly independent of the collisional environment. Sensitivity calculations show that the single-shot imaging of nascent CO in flames is possible. Signal interpretation for CO2 is more complicated, owing to strongly temperature-dependent absorption cross sections and strongly collider-dependent fluorescence quantum yield. These complications limit linear CO2 IR PLIF imaging schemes to qualitative visualization but indicate that increased signal level and improved quantitative accuracy can be achieved through consideration of laser-saturated excitation schemes.

Journal Article↗

Digital imaging fluorescence microscopy: spatial heterogeneity of photobleaching rate constants in individual cells.

Photobleaching and related photochemical processes are recognized experimental barriers to quantification of fluorescence by microscopy. We have measured the kinetics of photobleaching of fluorophores in living and fixed cells and in microemulsions, and have demonstrated the spatial variability of these processes within individual cells. An inverted fluorescence microscope and a high-sensitivity camera, together with high-speed data acquisition by a computer-controlled image processor, have been used to control precisely exposure time to excitation light and to record images. To improve the signal-to-noise ratio, 32 digital images were integrated. After correction for spatial variations in camera sensitivity and background fluorescence, the images of the relative fluorescence intensities for 0.065 micron2 areas in the object plane were obtained. To evaluate photobleaching objectively, an algorithm was developed to fit a three-parameter exponential equation to 20 images recorded from the same microscope field as a function of illumination time. The results of this analysis demonstrated that the photobleaching process followed first-order reaction kinetics with rate constants that were spatially heterogeneous and varied, within the same cell, between 2- and 65-fold, depending on the fluorophore. The photobleaching rate constants increased proportionally with increasing excitation intensity and, for benzo(a)pyrene, were independent of probe concentration over three orders of magnitude (1.25 microM to 1.25 mM). The propensity to photobleach was different with each fluorophore. Under the cellular conditions used in these studies, the average rates of photobleaching decreased in this order: N-(7-nitrobenz-2-oxa-1,3-diazole)-23,24-dinor-5-cholen-22-amine-3 beta-ol greater than acridine orange greater than rhodamine-123 greater than benzo(a)pyrene greater than fluorescein greater than tetramethylrhodamine greater than 1,1'dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine. The photobleaching appears to be an oxidation reaction, in that the addition of saturated solutions of Na2S2O5 to mineral oil microemulsions eliminated photobleaching of N-(7-nitrobenz-2-oxa-1,3-diazole)-23,24-dinor-5-cholen-22-amine-3 beta-ol or benzo(a)pyrene. We identified experimental conditions to observe, without detectable photobleaching, fluorophores in living cells, which can not be studied anaerobically. Useful images were obtained when excitation light was reduced to eliminate photobleaching, as determined from zero-time images calculated from the exponential fit routine.(ABSTRACT TRUNCATED AT 400 WORDS)

4-Chloro-7-nitrobenzofurazan↗

Virally-directed fluorescent imaging (VFI) can facilitate endoscopic staging.

BACKGROUND: Replication-competent, tumor specific herpes simplex virus NV1066 expresses green fluorescent protein (GFP) in infected cancer cells. We sought to determine the feasibility of GFP-guided imaging technology in the intraoperative detection of small tumor nodules. METHODS: Human cancer cell lines were infected with NV1066 at multiplicities of infection of 0.01, 0.1 and 1. Cancer cell specific infectivity, vector spread and GFP signal intensity were measured by flow cytometry and time-lapse digital imaging (in vitro); and by use of a stereomicroscope and endoscope equipped with a fluorescent filter (in vivo). RESULTS: NV1066 infected all cancer cell lines and expressed GFP at all MOIs. GFP signal was significantly higher than the autofluorescence of normal cells. One single dose of NV1066 spread within and across body cavities and selectively infected tumor nodules sparing normal tissue. Tumor nodules undetectable by conventional thoracoscopy and laparoscopy were identified by GFP fluorescence. CONCLUSION: Virally-directed fluorescent imaging (VFI) is a real-time novel molecular imaging technology that has the potential to enhance the intraoperative detection of endoluminal or endocavitary tumor nodules.

Animals↗

The use of time-resolved fluorescence imaging in the study of protein kinase C localisation in cells.

BACKGROUND: Two-photon-excitation fluorescence lifetime imaging (2P-FLIM) was used to investigate the association of protein kinase C alpha (PKCalpha) with caveolin in CHO cells. PKCalpha is found widely in the cytoplasm and nucleus in most cells. Upon activation, as a result of increased intracellular Ca2+ and production of DAG, through G-protein coupled-phospholipase C signalling, PKC translocates to a variety of regions in the cell where it phosphorylates and interacts with many signalling pathways. Due to its wide distribution, discerning a particular interaction from others within the cell is extremely difficult. RESULTS: Fluorescence energy transfer (FRET), between GFP-PKCalpha and DsRed-caveolin, was used to investigate the interaction between caveolin and PKC, an aspect of signalling that is poorly understood. Using 2P-FLIM measurements, the lifetime of GFP was found to decrease (quench) in certain regions of the cell from approximately 2.2 ns to approximately 1.5 ns when the GFP and DsRed were sufficiently close for FRET to occur. This only occurred when intracellular Ca2+ increased or in the presence of phorbol ester, and was an indication of PKC and caveolin co-localisation under these conditions. In the case of phorbol ester stimulated PKC translocation, as commonly used to model PKC activation, three PKC areas could be delineated. These included PKCalpha that was not associated with caveolin in the nucleus and cytoplasm, PKCalpha associated with caveolin in the cytoplasm/perinuclear regions and probably in endosomes, and PKC in the peripheral regions of the cell, possibly indirectly interacting with caveolin. CONCLUSION: Based on the extent of lifetime quenching observed, the results are consistent with a direct interaction between PKCalpha and caveolin in the endosomes, and possibly an indirect interaction in the peripheral regions of the cell. The results show that 2P-FLIM-FRET imaging offers an approach that can provide information not only confirming the occurrence of specific protein-protein interactions but where they occur within the cell.

Animals↗

Early detection of plant stress from changes in distributions of chlorophyll a fluorescence parameters measured with fluorescence imaging.

In this work, we used barley leaves suffering from a stress, for measurements of chlorophyll a fluorescence with an imaging fluorometer. We compared selected fluorescence parameters (FP) determined from the measurements of control (no stress) and afterwards stressed sample by classical statistical comparison (Mann-Whitney test) and by statistical comparison of shapes of distributions of the FPs (two-sample Smirnov test). We have found that there exist examples where statistically significant difference is not revealed using the classical statistical comparison (for given critical level), but statistically significant difference is revealed using comparisons of distributions (for the same critical level). It implies that the shape of statistical distribution of a FP is more sensitive to a stress of a sample than median of the FP. Further, the comparison of changes in shapes of statistical distributions of FPs is therefore more suitable for early detection of plant stress than a classical statistical comparison. The observed changes in the distributions of FPs are discussed.

Journal Article↗

Confocal fluorescent imaging of tracks from heavy charged particles utilising new Al2O3:C,Mg crystals.

A completely optical, non-destructive imaging of tracks in a fluorescent crystal provides a new way to detect and to assess doses from heavy charged particles and neutrons. The technique combines confocal fluorescent microscopy with a new radiation-sensitive, luminescent material based on aluminium oxide single crystals doped with carbon, magnesium and having aggregate oxygen vacancy defects (Al2O3:C,Mg). Radiation-induced colour centres in the new material have an absorption band at 620 nm and produce fluorescence at 750 nm with a high quantum yield and a short, 75 +/- 5 ns, fluorescence lifetime. Three-dimensional spatial distribution of fluorescent intensity allows one to obtain depth-dose distributions and to discriminate between high- and low-linear energy transfer radiations. Images of single tracks produced by different types of radiation have been obtained. Irradiations with a calibrated 241Am alpha source showed high efficiency for track detection. Thermal neutrons were detected using a nuclear reaction with a 6LiF radiator and production of alpha particles and tritium ions. Fast neutrons were detected using recoil protons produced in a polyethylene radiator installed in front of the crystalline detector. Three-dimensional reconstruction of a recoil proton propagating through the crystal was demonstrated.

Aluminum Oxide↗

Near-infrared fluorescence imaging and histology confirm anomalous edematous signal distribution detected in the rat lung by MRI after allergen challenge.

PURPOSE: To address the issue concerning the predominant location, on the left anatomic side, of edematous signals detected by magnetic resonance imaging (MRI) in the lungs of actively sensitized rats following intratracheal (IT) allergen challenge. MATERIALS AND METHODS: Near-infrared fluorescence (NIRF) imaging was used to detect the lobular distribution in the lungs of normal rats of an IT instilled fluorescent dye, Cy5.5. Actively sensitized Brown Norway rats were examined by MRI 24 hours after IT administration of ovalbumin. The perivascular edema was quantified by histology in the different lobes of lungs removed from the same animals immediately after the MRI acquisitions. RESULTS: An uneven distribution of Cy5.5 was found, predominantly on the left lobe, paralleling the localized development of allergic pulmonary inflammation in the left lobe detected as edematous signal by MRI and confirmed by histology. The patterns of the distributions of the dye between and within the lobes were very similar to those of perivascular edema assessed histologically. CONCLUSION: The data indicate a relationship between the molecular deposition of the dye detected by NIRF in the lungs and the distribution of allergen eliciting the development of pulmonary inflammation in actively rats. The combination of MRI with NIRF imaging may provide important information in preclinical pharmacologic research in the area of airway diseases. While MRI is able to address the effects of compounds on the inflammatory response in models of airways diseases, NIRF imaging may provide important insights on drug distribution and interaction in the lung, being thus suited for molecular imaging studies.

Allergens↗

Intramolecularly quenched BODIPY-labeled phospholipid analogs in phospholipase A(2) and platelet-activating factor acetylhydrolase assays and in vivo fluorescence imaging.

Phospholipase substrate analogs containing both a fluorescent BODIPY group and a quenching 2,4-dinitrophenyl (DNP) group were synthesized. They showed little fluorescence, but upon hydrolysis became fluorescent as the quenching group was removed. Two substrates were phosphatidylethanolamine analogs with a BODIPY-pentanoyl group at the sn-2 position and DNP linked to the amino head group. The third was a phosphatidylcholine analog with a BODIPY-labeled alkyl ether at the sn-1 position and a N-(DNP)-8-amino-octanoyl group at the sn-2 position. These compounds were evaluated as substrates for cytosolic (85 kDa) phospholipase A(2) (cPLA(2)) and plasma platelet-activating factor acetylhydrolase (rPAF-AH). Two were good substrates for cPLA(2) (specific activities: 18 and 5 nmol min(-1) mg(-1)) and all were good for rPAF-AH (specific activities: 17, 11, and 6 micro mol min(-1) mg(-1)). The minimal amount of enzyme detectable was 50 ng for cPLA(2) and 0.1 ng for rPAF-AH. These substrates were active in assays of PLA(2) in zebrafish embryo extracts and one was well suited for imaging of PLA(2) activity in living zebrafish embryos. Embryos were injected with substrate at the one- to four-cell stage and allowed to develop until early somitogenesis when endogenous PLA(2) activity increases dramatically; substrate persisted (12 h) and specifically labeled cells of the developing notochord.

1-Alkyl-2-acetylglycerophosphocholine Esterase↗

A system for real time fluorescence imaging in color for tumor diagnosis.

Early tumors can be diagnosed by the fluorescence of an injected, tumor-specific agent such as dihematoporphyrin ether. However, brightness or intensity contrast is low because of the autofluorescence of tissue. Addition of color (hue) information aids in detection of tumors, and in elimination of false positives. Standard color video cameras are not sensitive enough to image the weak fluorescence. Thus an intensified monochrome video camera has been equipped with a synchronized color filter wheel, and the image displayed by multiplexing alternate lines to a red green blue (RGB) monitor.

Animals↗

High-speed, whole-column fluorescence imaging detection for isoelectric focusing on a microchip using an organic light emitting diode as light source.

An integrated and simplified microfluidic device using a 250 microm x 1-4 cm of organic light emitting diode (OLED) array as a two-dimensional light source for single-channel and multichannel whole-column imaging detection was developed. This fluorescence detection system was used for isoelectric focusing (IEF) of R-phycoerythrin in a microchip. The IEF conditions were optimized, and the total analysis time was extremely reduced to 30 s for 2-cm-long microchannels at 700 V/cm of electric field strength without the presence of electroosmotic flow. The compression of pH gradient caused by electrolytes drawing into the microchannels was efficiently restrained when 1% hydroxylpropylmethyl cellulose in 2% ampholyte was used as the carrier for IEF. Under optimized IEF conditions, the detection limit of this system was approximately 0.6 microg/mL or 45 pg at 75 nL/column injection of R-phycoerythrin. This OLED-induced fluorescence detection system for WCID provides a high-speed IEF technique with quantitative ability and the potential for high integration and throughput microchip systems.

Fluorescence↗

A study of the binding of merocyanine 540 to myeloid leukemia M1 cells using an intensified charge-coupled device for fluorescence imaging microscopy.

The binding of merocyanine 540 (MC540) to murine myeloid leukemia (M1) cells and normal erythrocytes was measured by fluorescence digital imaging microscopy using an intensified charge-coupled device. It was found that, on average, about three times more MC540 were bound to a unit membrane area of M1 cells than erythrocytes, a result consistent with previous studies. However, it was shown for the first time that MC540 binding varied significantly from one M1 cell to the next, and about 15% of the sensitized M1 cells were as MC540-negative as normal erythrocytes. Using the leukemic inhibitory factor as a differentiation inducer, M1 cells were induced to differentiate into mature macrophage-like cells in vitro. Such treatment lowered the average MC540 binding by about one-third but did not affect the cell-to-cell variation significantly.

Animals↗

Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging.

A recent development in biomedical imaging is the non-invasive mapping of molecular events in intact tissues using fluorescence. Underpinning to this development is the discovery of bio-compatible, specific fluorescent probes and proteins and the development of highly sensitive imaging technologies for in vivo fluorescent detection. Of particular interest are fluorochromes that emit in the near infrared (NIR), a spectral window, whereas hemoglobin and water absorb minimally so as to allow photons to penetrate for several centimetres in tissue. In this review article we concentrate on optical imaging technologies used for non-invasive imaging of the distribution of such probes. We illuminate the advantages and limitations of simple photographic methods and turn our attention to fluorescence-mediated molecular tomography (FMT), a technique that can three-dimensionally image gene expression by resolving fluorescence activation in deep tissues. We describe theoretical specifics, and we provide insight into its in vivo capacity and the sensitivity achieved. Finally, we discuss its clinical feasibility.

Animals↗

High-light stress and photoprotection in Umbilicaria antarctica monitored by chlorophyll fluorescence imaging and changes in zeaxanthin and glutathione.

The effect of high light on spatial distribution of chlorophyll (Chl) fluorescence parameters over a lichen thallus (Umbilicaria antarctica) was investigated by imaging of Chl fluorescence parameters before and after exposure to high light (1500 micro mol m (-2) s (-1), 30 min at 5 degrees C). False colour images of F (V)/F (M) and Phi (II) distribution, taken over thallus with 0.1 mm (2) resolution, showed that maximum F (V)/F (M) and Phi (II) values were located close to the thallus centre. Minimum values were typical for thallus margins. After exposure to high light, a differential response of F (V)/F (M) and Phi (II) was found. The marginal thallus part exhibited a loss of photosynthetic activity, manifested as a lack of Chl fluorescence signal, and close-to-centre parts showed a different extent of F (V)/F (M) and Phi (II) decrease. Subsequent recovery in the dark led to a gradual return of F (V)/F (M) and Phi (II) to their initial values. Fast (30 min) and slow (1 - 22 h) phase of recovery were distinguished, suggesting a sufficient capacity of photoprotective mechanisms in U. antarctica to cope with low-temperature photoinhibition. Glutathione and xanthophyll cycle pigments were analyzed by HPLC. High light led to an increase in oxidized glutathione (GSSG), and a conversion of violaxanthin to zeaxanthin, expressed as their de-epoxidation state (DEPS). The responses of GSSG and DEPS were reversible during subsequent recovery in the dark. GSSG and DEPS were highly correlated to non-photochemical quenching (NPQ), indicating involvement of these antioxidants in the resistance of U. antarctica to high-light stress. Heterogeneity of Chl fluorescence parameters over the thallus and differential response to high light are discussed in relation to thallus anatomy and intrathalline distribution of the symbiotic alga Trebouxia sp.

Acclimatization↗

Near-infrared fluorescent imaging of tumor apoptosis.

Noninvasive imaging using radioactive annexin V is an emerging strategy for the assessment of cell death in vivo (F. G. Blankenberg, and H. W. Strauss. Apoptosis, 6: 117-123, 2001.). Therefore, we investigated whether annexin V labeled with the fluorophore Cy5.5 (Cy) could serve as a probe for imaging of tumor apoptosis using near infrared fluorescence (NIRF). We prepared active Cy-annexin (an equimolar dye:protein ratio) that bound to apoptotic Jurkat T cells and an inactive Cy-annexin probe (>2 dyes/mol protein) that did not. Active Cy annexin was used to image a 9L gliosarcoma, constitutively expressing green fluorescent protein marker, and the CR8 variant of Lewis lung carcinoma, stably transfected to express DsRed2. The expression of transfected fluorescent protein provided an indication of tumor margins and a means of defining tumor-associated NIRF signal intensity with both tumor models. Tumors were imaged with and without cyclophosphamide treatment. In both tumor models active Cy-annexin V tumor NIRF signal increased two to three times after the treatment. Tumor NIRF signal developed by 75 min after active Cy-annexin injection and remained for a 20-h observation period. Inactive annexin V was used as a control in the CR8 carcinoma experiments and resulted in a low nonspecific signal. With the 9L gliomosacrcoma model, active Cy-annexin V bound to both tumor cells (Cy-annexin V staining only) and endothelial cells (costained with Cy-annexin V and antibody to the endothelial marker CD31). Our results demonstrate that active Cy-annexin can be used as a NIRF probe to image apoptosis from outside an intact living animal and may provide nonradioactive method of measuring the antiproliferative effects of cancer chemotherapeutic regimens.

Animals↗

Near-field fluorescence imaging of genetic material: toward the molecular limit.

Chromosomes, DNA, and single fluorescent molecules are studied using an aperture-type near-field scanning optical microscope with tuning fork shear force feedback. Fluorescence in situ hybridization labels on repetitive and single copy probes on human metaphase chromosomes are imaged with a width of 80 nm, allowing their localisation with nanometer accuracy, in direct correlation with the simultaneously obtained topography. Single fluorophores, both in polymer and covalently attached to amino-silanized glass, are imaged using two-channel fluorescence polarization detection. The molecules are selectively excited according to their dipole orientation. The orientation of the dipole moment of all molecules in one image could be directly determined. Rotational dynamics on a 10-ms to 100-s timescale is observed. Finally, shear force imaging of double-stranded DNA with a vertical sensitivity of 0.2 nm is presented. A DNA height of 1.4 nm is measured, which indicates the nondisturbing character of the shear force mechanism.

Chromosomes, Human, Pair 1↗

An assay of ganglioside using fluorescence image analysis on a thin-layer chromatography plate.

A new and simple fluorometric method for determine quantities of gangliosides ranging from pico- to nanomoles is reported. Spraying hydrochloric acid followed by a heating treatment, sugars (glucose, galactose, fucose, N-acetylgalactosamine, N-acetylglucosamine, N-acetylneuraminic acid (sialic acid)), gangliosides (G(M1), G(D1a), G(T1b)), and asialoganglioside (asialoG(M1)) on thin-layer chromatography plates produced fluorescence under 365-nm UV light. This fluorescence production of each sample was greatly dependent on the heating temperature. As sialic acid fluoresced readily at lower temperature (approximately 90 degrees C), we were able to distinguish sialic acid easily from other sugars tested. To determine gangliosides based on this sialic acid fluorescence, calibration curves for gangliosides were obtained by high-performance thin-layer chromatography and the image-analyzing system equipped with a CCD camera. The observed fluorescence images were analyzed using image-analyzing software packages and the determined calibration curves for ganglioside-bound sialic acids were reproducible and showed a high linearity in a wide range from 47 pmol to 4.5 nmol. Since the fluorescence from sialic acid is easily measurable on TLC plates and is sensitive over a wide range of sample concentration, the present method is applicable for quantitative determination of gangliosides.

Animals↗

Objective quality evaluation of fluorescence images to optimize automatic image acquisition.

BACKGROUND: Because different spectral sensitivities of human eye and image sensor lead to different perception of fluorescence signals, data generation is an important step in image analysis, because following work steps depend on it. METHODS: We developed a method to determine image parameters allowing an objective appraisal of quality of image data as well as a separation of object and background. RESULTS: Calculated parameters can be used for an automated adjustment of camera parameters in image analysis systems. DISCUSSION: Our approach for objective adjusted data generation achieves an improvement of analysis quality.

Cell Line, Tumor↗