PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MOUTH PROTECTORS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Dental management of neonates requiring prolonged oral intubation.

An orotracheal route is frequently the preferred method of intubation for premature infants. Nasal intubation may contribute to airway obstruction and possible hypoxia, further contributing to labored breathing. Additional complications include occlusion of the nasal aperture during a crucial period of development, nasal infections, and hypertrophy of the nasal lining. Oral mucosa is less susceptible to damage than nasal mucosa; however, orotracheal tubes must be stabilized against displacement from tongue and jaw movements to prevent discomfort and subsequent tissue trauma. Problems associated with rehabilitation of very-low-birth-weight neonates and other infants requiring long-term oral intubation include palatal grooving, acquired cleft palate, and damage to the primary dentition. Various intraoral aids have been used to reduce pressure application from intubation and feeding tubes on the palatal tissues. References to these procedures have yet to be reported in the prosthodontic literature. This article presents a rational for design and construction of an intraoral device which protects the palatal tissues and stabilizes the orotracheal tube.

Alveolar Process↗

A technique for shielding electron beams used in radiotherapeutic management of head and neck cancer.

One of the major complications of radiation therapy in the management of maxillofacial tumors is the postradiation damage to the healthy tissues adjacent to the tumors. The success of radiation therapy is often limited by the treatment sequelae. The use of shielding prostheses reduces the number of potential treatment sequelae caused by the administration of therapeutic radiation for head and neck tumors. A technique for shielding uninvolved tissues from external electron beams used in therapeutic radiation treatment of head and neck cancer is described. The materials required are readily available and the shielding prosthesis can be easily fabricated by any dentist with a thorough understanding of radiation therapy, dosimetry, and the goals of treatment with radiation therapy.

Acrylic Resins↗

A bimaxillary sports mouthguard: a modified technique.

The bimaxillary mouthguard provides enhanced protection for a participant in contact sports. This article describes the fabrication of a polyvinylacetate-polyethylene (PVAc-PE) bimaxillary mouthguard in which the connection of the maxillary and mandibular components is reinforced by pressure thermoforming a 2-mm PVAc-PE sheet over the labial and buccal portions of the mouthguard.

Athletic Injuries↗

Nursing management of the infant with an intraoral appliance.

A recently developed intraoral device is being used for infants who require orotracheal and orogastric intubation. The purpose of the appliance is to prevent complications associated with long-term intubation, such as palatal groove formation, acquired cleft palate, defective primary dentition, and chronic irritation of the airway. The nursing care required for an infant with this intraoral appliance is described. The procedure for daily removal of the appliance, oral hygiene, and assessment of the oral cavity is presented. Other nursing interventions addressed include provision of non-nutritive sucking, initiation of oral feedings, and parent teaching and support.

Humans↗

Randomized-controlled trial: effect of a reservoir biteguard on quality of life in xerostomia.

BACKGROUND: To assess the effect of a reservoir biteguard for artificial saliva on the oral health-related quality of life of patients with xerostomia. METHODS: Double-blind randomized placebo-controlled trial among 86 adults with xerostomia. Study group received the trial biteguard. Control group received a conventional biteguard. Outcomes were number of impacts and total scores as recorded by oral impacts on daily performances (OIDP). RESULTS: At 1-month follow up 84 people remained in the trial. The median number of impacts in the study and control groups was 3 and 4 respectively. The median total score was 6 and 12 respectively. In ANCOVA receipt of the reservoir biteguard reduced the number of impacts recorded by OIDP but there was no difference in the total score. CONCLUSIONS: Reservoir biteguards improved the quality of life of people with xerostomia by reducing the number of impacts on daily life.

Adult↗

Self-mutilation behaviour in Lesch-Nyhan syndrome.

Lesch-Nyhan syndrome (LNS), first described in 1964 by Lesch and Nyhan, is a rare X-linked genetic disorder involving (near) absence of the enzyme hypoxanthine-guanine phosphoribosyl transferase (HPRT). It occurs in 1:100,000 to 380,000 live births (1, 2). The deficiency of HPRT activity leads to an excessive uric acid production resulting in neurological, renal and musculoskeletal manifestations. Death usually occurs in the second or third decade from infection or renal failure. Clinical presentation is characterized by mental retardation, choreoathetosis, spasticity, hyperuricemia and cerebral palsy. A characteristic feature of LNS is the appearance of intractable self-injurious behaviour (SIB), usually in the form of severe lip and finger biting, gouging of eyes, face scratching and head banging requiring extreme management techniques such as the application of restraints and or extraction of teeth at an early age. In this case report a unique approach of SIB in LNS is presented.

Bites, Human↗

Factors influencing mercury evaporation rate from dental amalgam fillings.

Factors influencing mercury evaporation from dental amalgam fillings were studied in 11 volunteers. Air was drawn from the oral cavity for 1 min and continuously analyzed with a mercury detector. In six volunteers the median unstimulated evaporation rate was 0.1 ng Hg/s, range 0.09-1.3 ng Hg/s. After chewing gum for 5 min the highest evaporation rate was 2.7 ng Hg/s. Chewing paraffin wax gave only a small increase in evaporation rate. Changes in airflow rates between 1.5 and 2.5 1/min during the 1 min sampling did not change the amount of mercury drawn from the oral cavity. Sampling with different mouthpieces and closed mouth was compared to open mouth sampling with a thin plastic tube. It was found that the latter method could result in lower values for some volunteers due to simultaneous mouth breathing. After placing individual plastic teeth covers in the mouth, the intraoral evaporation of mercury decreased immediately by 89-100% of previous levels. This technique could be used to detect mercury evaporation from separate amalgam fillings or to reduce the intraoral mercury vapor concentration. Rinsing the mouth with heated water for 1 min increased the mean evaporation rate by a factor of 1.7 when the water temperature increased from 35 degrees C to 45 degrees C.

Adult↗

The influence of impact object characteristics on impact force and force absorption by mouthguard material.

Most impact force and impact energy absorption tests for mouthguards have used a steel ball in a drop-ball or the pendulum device. However, in reality most sports-related trauma is caused by objects other than the steel ball, e.g. various sized balls, hockey puck, or bat or stick. Also, the elasticity, the velocity and the mass of the object could change the degree and the extent of injuries. In this study, we attempted to measure the impact force from actual sports equipment in order to clarify the exact mechanism of dental-related sports injuries and the protective effects of mouthguards. The present study was conducted using the pendulum impact device and load cell. Impact objects were removable. Seven mobile impact objects were selected for testing: a steel ball, baseball, softball, field hockey ball, ice hockey puck, cricket ball, and wooden baseball bat. The mouthguard material used in this study was a 3-mm-thick Drufosoft (Dreve-Dentamid GmbH, Unna, Germany), and test samples were made of the one-layer type. The peak transmitted forces without mouthguard ranged from the smallest (ice hockey stick, 46.9 kgf) to the biggest (steel ball, 481.6 kgf). The peak transmitted forces were smaller when the mouthguard was attached than without it for all impact materials but the effect was significantly influenced by the object type. The steel ball showed the biggest (62.1%) absorption ability while the wooden bat showed the second biggest (38.3%). The other balls or the puck showed from 0.6 to 6.0% absorbency. These results show that it is important to test the effectiveness of mouthguards on specific types of sports equipment. In future, we may select different materials and mouthguard designs suitable for specific sports.

Absorption↗

The influence of the sensor type on the measured impact absorption of mouthguard material.

Mouthguards have been tested for impact energy absorption using drop-ball and/or pendulum devices. While all reports show efficiency of the mouthguard, the impact absorption abilities reported differ considerably. This difference has been attributed to differences of mouthguard material, design, and the impact force used. However, it is also possibly because of the difference in the sensors used in the experiments. The purpose of this study was to test three types of sensors and to assess which type was most appropriate for measurement of the impact absorption ability of mouthguards. A pendulum-type testing equipment and steel ball, wooden bat, baseball, field-hockey ball were used as the impact object. For all sensors or impact objects, the mouthguard decreased the impact forces. However, the absorption ability of the mouthguard varied according to the sensor or impact object. The absorbency values became smaller with the strain gauge, the accelerometer, and the load cell, respectively. With the steel ball as the impact object, 80.3% of impact absorption was measured with the strain gauge and the accelerometer but, only 62.1% with the load cell sensor. With the wooden bat, impact absorption was 76.3% with the strain gauge and 38.8% for the load cell. For the baseball ball, the absorption measurement decreased from 46.3% with the strain gauge to 4.36 with the load cell and for the field-hockey ball, the decrease in measurement values were similar (23.6% with the strain gauge and 2.43% with the load cell). It is clear that the sensor plays an important role in the measurement values reported for absorbency of mouthguard materials and a standard sensor should be used for all experiments.

Absorption↗

Are all mouthguards the same and safe to use? The influence of occlusal supporting mouthguards in decreasing bone distortion and fractures.

The safety benefits of mouthguards have been demonstrated in many studies, with many authors and sports dentists strongly recommending the wearing of mouthguards. However, wearing a mouthguard with incorrect occlusion might cause a variety of problems. It comes as no surprise that a traumatic blow to the chin, while wearing an insufficient mouthguard lacking anterior contact, can result in severe distortions to the mandibular bone, and bone fractures. The aim of this study was to clarify how ineffective insufficient occlusal supporting mouthguards are and how dangerous they can be to use. Consequently, in this study, occlusal supportive areas were varied and accelerations of head and distortions of the mandible were measured using an artificial skull model and a pendulum impact device. As a result, the distortions of the mandible tended to increase as the supported area decreased. On the contrary, accelerations of the head decreased as the occlusion part decreased. Thus, a lot of impact energy was consumed in the distortion of the mandible; accordingly, it seemed that only a little destructive energy was transferred to the head. From this study, it would seem that wearing a mouthguard, which is insufficient in the occlusion, has the potential of causing a bone fracture of the mandible. Consequently, mouthguards should have proper occlusion.

Acceleration↗

Incidence of cerebral concussions associated with type of mouthguard used in college football.

Controversy exists among sports dentists as to whether or not a 'custom made' mouthguard is more effective in reducing the incidence of cerebral concussion than the boil-and-bite 'non-custom made' mouthguard. While members on each side remain steadfast in their opinion, not a single epidemiological study has been conducted to investigate the effect of type of mouthguard worn on the incidence of cerebral concussion. The aim of this study was to determine if there was a difference between the type of mouthguard worn and the incidence of cerebral concussions among National Collegiate Athletic Association (NCAA) Division I-A football players. During the 15-week 2001 college football season, trainers entered, via an interactive web site, weekly data for each game and practice sessions for the preceding week. Eighty-seven (76%) out of a possible 114 Division I teams participated. A total of 506 297 athletic exposures were recorded; 369 brain concussions were reported. The incidence of cerebral concussions per 1000 exposures was 0.73. Utilizing a risk ratio with a 95% confidence interval, no statistical difference occurred in the incidence of cerebral concussions between football players wearing custom made versus non-custom made mouthguards (0.990,1.750). In this study, there was no advantage of wearing a custom made mouthguard over a boil-and-bite mouthguard to reduce the risk of cerebral concussion in football players.

Brain Concussion↗

An in vitro study of the efficacy of mouthguard protection for dentoalveolar injuries in deciduous and mixed dentitions.

Sports-related dental trauma remains a risk for children and adolescents. Although mouthguards provide protection, up to 25% of dentoalveolar injuries can occur with a mouthguard in place. This study examined the effect of mouthguard protection in an in vitro model. A total of 97 sheep mandibular segments with incisors at four developmental stages (early deciduous, ED, n = 37; middle deciduous, MD, n = 20; late deciduous, LD, n = 18; mixed dentition, PD, n = 22) was used. Customised pressure formed mouthguards (MG) provided protection from trauma produced by a servohydraulic materials testing machine to test incisors. Injuries were examined clinically, radiographically and by dissection. Mean forces required to produce dentoalveolar injury were significantly greater in test (with MG) teeth than control (no MG) teeth. Mean forces to produce injury in test teeth decreased with resorbing root lengths. Deciduous incisors differed in injury type: subluxations and horizontal root fractures predominated in test teeth; lateral luxations and horizontal root fractures in control teeth. Predominant injuries in test and control permanent incisors were enamel infractions and subluxations. The magnitude of lateral luxation measurements of individual teeth was reduced significantly by mouthguard protection in both deciduous and permanent dentitions. The mouthguard tended to increase the mobility of the teeth it encompassed and, in some instances, promoted dentoalveolar injury of adjacent teeth.

Alveolar Process↗

Mouth guard for athletes during orthodontic treatment.

Mouth guards have been proven to greatly reduce the number and severity of traumatic dental injuries to participants in contact sports. However, there are some difficult problems in making mouth guards for athletes with orthodontic appliances on their teeth. We developed a method of making mouth guards by using a coating material for such athletes to prevent dental and oral sports injuries and to protect the orthodontic appliances. This mouth guard fits well and does not damage the appliances.

Athletic Injuries↗

Forces transmitted through a laminated mouthguard material with a Sorbothane insert.

Sorbothane is a visco-elastic polyurethane that has been used in sports and orthopaedic applications because of its shock-absorbing properties. The aim of this laboratory study was to evaluate the effect of an intermediate layer of Sorbothane on the peak force transmitted through two thermoplastic ethylene vinyl acetate (EVA) sheets as used in the construction of a custom-made sports mouthguard. The EVA sheets were tested at room temperature after thermal lamination under pressure, either without (control) or with a Sorbothane intermediate layer of 1.1 or 2.65 mm thickness. A piezo-electric transducer was used to measure the peak force transmitted through each sample from a free-falling steel ram. The peak force recorded was significantly less for laminated EVA samples with a Sorbothane intermediate layer than for controls of comparable thickness. We conclude that a Sorbothane intermediate layer between heat-cured laminated EVA sheets, as used in the fabrication of a custom-made sports mouthguard, may dissipate significantly the force of impact resulting from a blow to the teeth and jaws.

Analysis of Variance↗

Oral injury and mouthguard usage by athletes in Japan.

The use of mouthguards in contact sports effectively prevents oral injury and preserves oral structures. We investigated oral injuries and awareness concerning mouthguards among Japanese high school soccer and rugby players. Athletes were asked a series of questions concerning their history of oral injury while participating in sports, and their pattern of mouthguard use was determined. The data were evaluated statistically using chi-square analysis. The incidence of oral injuries was 32.3% for soccer athletes and 56.5% for rugby athletes, with 0.8% and 24.1% of the respective groups having mouthguards. There were significant differences between the soccer and rugby groups (P < 0.001). Although 81.8% of soccer athletes thought mouthguards were unnecessary, only 26.2% of rugby athletes shared this opinion and there was a significant difference between the soccer and rugby groups. Many soccer athletes had insufficient knowledge about mouthguards and were not concerned about preventing oral injury, although it was in fact a common problem in their sport. Athletes as well as coaches must be made aware of the high risk of oral injury when playing soccer, rugby, and other contact sports.

Adolescent↗

Traumatic injuries of the teeth in connection with general anaesthesia and the effect of use of mouthguards.

The aim of the present study was to describe the frequency of dental injuries over a 10-year period, where a mouthguard was used in approximately 10% of intubation cases or endoscopying. The types of injury are presented and the use of different types of mouthguard is discussed. Among 120,086 procedures involving anaesthesia carried out in the period 1983-1992 at Bispebjerg Hospital, Copenhagen, 75 cases of dental trauma occurred. The incidence of dental traumatic injuries was 0.06%. Although eight patients had used mouthguards they were registered with traumatic injuries to the teeth in connection with general anaesthesia. Of the patients, 58% were women and 42% men, with a mean age of 61 years. Seventy-eight percent of the injuries were located in the maxilla and 91% of these involved the incisor area of the maxilla. Forty-one percent were classified as lateral luxations or mobile teeth, 47% were classified as fractured teeth, 10% tooth avulsions and the remaining 2% were classified as concussions. Because of the low frequency of traumatic dental injuries in connection with general anaesthesia and the non-significant effect of the use of mouthguards, routine use of mouthguards is not recommended. Only when a patient is to have an endoscopy done under general anaesthesia, and the surgeon or anaesthesiologist foresees problems (restricted mouth opening, extensive fixed prosthetics, extensive loss of marginal bone) is use of an individually made mouthguard indicated.

Adult↗

Experimental comparative study of various mouthguards.

The aim of this study was to evaluate the mechanical and physical properties of several standard size commercially available mouthguards. For the purpose of objective testing, a special study model, which the various gum shield devices could be fitted onto, was developed to record tooth deflection caused by impact forces induced by a pendulum ram impact testing machine. The data measured on teeth provided with various gum shield devices were correlated with those of unprotected teeth; this enabled the individual cushioning effects of the respective devices and their specific force conduction to be evaluated. Using mouthguards considerably diminishes the deflection of the teeth subjected to stress in comparison with the row of unprotected teeth. In addition, force is transmitted to the adjacent teeth all the way to the distal regions of the row of teeth. The individual cushioning effects are directly correlated to the thickness of the material; the force distribution is determined by the rigidity of the gum shield device. The devices examined showed considerable differences with regard to force distribution and dimensioning. The study showed that this was due to the thickness of the materials, the manufacturing process and the composition of the materials of the devices examined. In comparison to laboratory-produced devices of similar material thickness, the devices that were designed to be fitted by the user achieved significantly poorer results as regards both cushioning properties and dissipation of exerted forces.

Athletic Injuries↗

Relationship between temporomandibular joint dynamics and mouthguards: feasibility of a test method.

A test system was developed establishing the feasibility of collecting biomechanical data as they relate to the use of mouthguards. Previous experimental studies have examined the physical and mechanical properties of mouthguard materials. This information has been used as a guide for establishing material standards and specifications for the fabrication of mouthguards, but it lacks the key biomechanical parameters required for a thorough mouthguard evaluation. The current study was designed to assess whether the impact force, condylar deflection, and strain superior to the temporomandibular joint region could be measured. A drop test was conducted on a cadaveric specimen to simulate loading at the chin point. To measure the force of impact, an accelerometer was attached to an impactor of known mass. High-speed biplanar (1000 frames per second) radiographs were used to determine condylar displacement. Radio-opaque markers were inserted into the bone at predetermined locations. Total displacement of these markers was determined in reference to anatomical landmarks. Strain gauges were attached to the mandible and skull to monitor the effects of the condyle impacting the base of the skull. Based on the data collected, forces were calculated by determining the product of the time-based acceleration and known mass. A measurable change in force between the mouthguards and the control (no mouthguard) was demonstrated. The average condylar displacement was successfully measured and indicated as an increase in total deflection for impacts conducted with mouthguards. Quantifiable strain was measured in the region above the mandibular fossa with and without the insertion of a mouthguard at all impact conditions. However, it was determined that additional gauges would provide critical data. Key biomechanical parameters for chin-point impacts were determined in the current study. The technique demonstrated that both displacement within the mandibular fossa and loading of the condyles occur during the impact event. Although the current study established a technique that can be used to examine the relationship between mouthguards and jaw-joint injuries, the role, if any, mouthguards play in the reduction of injuries cannot be established until a thorough analysis is completed.

Acceleration↗