PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Optimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Constrained global optimization for estimating molecular structure from atomic distances.

Finding optimal three-dimensional molecular configurations based on a limited amount of experimental and/or theoretical data requires efficient nonlinear optimization algorithms. Optimization methods must be able to find atomic configurations that are close to the absolute, or global, minimum error and also satisfy known physical constraints such as minimum separation distances between atoms (based on van der Waals interactions). The most difficult obstacles in these types of problems are that 1) using a limited amount of input data leads to many possible local optima and 2) introducing physical constraints, such as minimum separation distances, helps to limit the search space but often makes convergence to a global minimum more difficult. We introduce a constrained global optimization algorithm that is robust and efficient in yielding near-optimal three-dimensional configurations that are guaranteed to satisfy known separation constraints. The algorithm uses an atom-based approach that reduces the dimensionality and allows for tractable enforcement of constraints while maintaining good global convergence properties. We evaluate the new optimization algorithm using synthetic data from the yeast phenylalanine tRNA and several proteins, all with known crystal structure taken from the Protein Data Bank. We compare the results to commonly applied optimization methods, such as distance geometry, simulated annealing, continuation, and smoothing. We show that compared to other optimization approaches, our algorithm is able combine sparse input data with physical constraints in an efficient manner to yield structures with lower root mean squared deviation.

Algorithms↗

Effect of unrealistic optimism, perceived control over disease, and experience with female cancer on behavioral intentions of Israeli women to undergo screening tests.

Early detection of cancer can lower mortality rates. Detection tests are available for some cancers such as breast and cervical cancer. Unrealistic optimism can affect compliance with health recommendations. Factors such as past experience (personal or at workplace) and perceived control over the disease influence unrealistic optimism. The purpose of this study was to examine the influence of past experience and perceived control over disease on unrealistic optimism towards breast and cervical cancer, and to examine the effect of unrealistic optimism, perceived control over the disease, and past experience on intentions to undergo screening tests. The study design was quasi-experimental correlative. Past experience was measured among 3 groups of women living in Tel-Aviv ranging in age from 21 to 60 years: oncology nurses (n = 50), obstetric nurses (n = 50), and laywomen (n = 50). These groups were presumed to differ from each other in the extent to which they were aware of cancer. In addition, the 2 types of malignancy represented different levels of awareness. Questionnaires were used to measure the study variables. Experience had a strong impact on unrealistic optimism with both cancers. However, the cancers differed in the impact of unrealistic optimism on behavioral intentions. With breast cancer (the more frequent), there was only a main effect of unrealistic optimism. A 3-way interaction was found with cervical cancer. The results indicate that unrealistic optimism plays a role in predicting participation in early detection testing and should be considered as an influencing factor in health-promoting plans.

Adult↗

Which factors determine the optimal pedaling rate in sprint cycling?

INTRODUCTION: Mechanical power output in sprint cycling depends on pedaling rate, with an optimum at around 130 revolutions per minute (rpm). In this study, the question is addressed if this optimal pedaling rate can be understood from a Hill-type description of muscular dynamics. In particular, it is investigated how 1) the power-velocity relationship that follows from Hill's force-velocity relationship and 2) activation dynamics (from the perspective of which the optimal pedaling rate is near-zero) affect the optimal pedaling rate. METHODS: A forward dynamics modeling/simulation approach is adopted in this study. The skeletal model is a 2D linkage of rigid segments; it is actuated by eight Hill-type "muscles." Input of the model is the neural stimulation of the muscles, output is the resulting movement and variables dependent thereupon, such as pedal forces. For a wide range of isokinetic pedaling rates, the neural stimulation is optimized with respect to the average mechanical power output. RESULTS: Correspondence between experimental data and simulation results regarding 1) the (pedaling-rate dependent) muscle phasing, 2) pedal forces, and 3) the power-pedaling rate relationship is good. At the optimal pedaling rate predicted by the model (120 rpm), muscles contract at velocities well below those that maximize their power output. Finally, when a model is considered that lacks activation dynamics, it is found that both the optimal pedaling rate and the maximal power output increase substantially. DISCUSSION: From the results pertaining to the standard model, it is concluded that the optimal pedaling rate is not uniquely specified by the power-velocity relationship of muscle, as suggested in literature. From the results pertaining to the model lacking activation dynamics, it follows that activation dynamics plays a surprisingly large role in determining the optimal pedaling rate. It is concluded that the pedaling rate that maximizes mechanical power output in sprint cycling follows from the interaction between activation dynamics and Hill's power-velocity relationship.

Bicycling↗

Preload optimization using "starling curve" generation during shock resuscitation: can it be done?

Preload-directed resuscitation is the standard of care in U.S. trauma centers. As part of our standardized protocol for traumatic shock resuscitation, patients who do not respond to initial interventions of hemoglobin replacement and fluid volume loading have optimal preload determined using a standardized algorithm to generate a "Starling curve." We retrospectively analyzed data from 147 consecutive resuscitation protocol patients during the 24 months ending August 2002. Fifty (34%) of these patients required preload optimization, of which the optimization algorithm was completed in 36 (72%). The average age of those who required preload optimization was 44 +/- 3 years vs. 34 +/- 1 years for patients who did not. Execution of the algorithm caused PCWP to increase from 18 +/- 1 mmHg to a maximum of 25 +/- 2 mmHg and CI to increase from 3.2 +/- 0.1 L/min m(-2) to 4.5 +/- 0.4 L/min m(-2). Algorithm logic determined PCWP = 24 +/- 2 to be optimal preload at the maximum CI = 4.8 +/- 0.4, and as the volume loading threshold for the remaining time of the resuscitation process. Starling curve preload optimization was begun 6.5 +/- 0.8 h after start of the resuscitation protocol and required 36 +/- 5 min and 4 +/- 0.4 fluid boluses (1.6 +/- 0.2 L). Comparison of early response of those patients who required preload optimization and those who did not indicated hemodynamic compromise apparent in the 1st 4 h of standardized resuscitation. We conclude that preload optimization using sequential fluid bolus and PCWP-CI measurement to generate a Starling curve is feasible during ICU shock resuscitation, but that there is the disadvantage that increasing and maintaining high PCWP may contribute to problematic tissue edema.

Abdominal Injuries↗

Optimal control of neuronal activity.

We investigate the optimal control of neuronal spiking activity for neurons receiving a class of random synaptic inputs, characterized by a positive parameter alpha. Optimal control signals and optimal variances are found exactly for the diffusion process approximating an integrate and fire model. When synaptic inputs are "sub-Poisson" (alpha<0.5), we find that the optimal synaptic input is a delta function (corresponding to bang-bang control) and the optimal signal is not unique. Poisson synaptic input is the critical case: The control signal is unique, but the control signal is still a delta function. For "supra-Poisson" (alpha>0.5) inputs, the optimal control is smooth and unique. The optimal variance obtained in the current paper sets the lowest possible bound in controlling the stochasticity of neuronal activity. We also discuss how to implement the optimal control signal for certain model neurons.

Action Potentials↗

Electrical defibrillation optimization: an automated, iterative parallel finite-element approach.

To date, optimization of electrode systems for electrical defibrillation has been limited to hand-selected electrode configurations. In this paper we present an automated approach which combines detailed, three-dimensional (3-D) finite-element torso models with optimization techniques to provide a flexible analysis and design tool for electrical defibrillation optimization. Specifically, a parallel direct search (PDS) optimization technique is used with a representative objective function to find an electrode configuration which corresponds to the satisfaction of a postulated defibrillation criterion with a minimum amount of power and a low possibility of myocardium damage. For adequate representation of the thoracic inhomogeneities, 3-D finite-element torso models are used in the objective function computations. The CPU-intensive finite-element calculations required for the objective function evaluation have been implemented on a message-passing parallel computer in order to complete the optimization calculations in a timely manner. To illustrate the optimization procedure, it has been applied to a representative electrode configuration for transmyocardial defibrillation, namely the subcutaneous patch-right ventricular catheter (SP-RVC) system. Sensitivity of the optimal solutions to various tissue conductivities has been studied. Results for the optimization of defibrillation systems are presented which demonstrate the feasibility of the approach.

Algorithms↗

Optimization of wide-band linear arrays.

An optimization method is proposed for linear arrays to be used in ultrasound systems under wide-band operation. A fast algorithm, the threshold accepting, has been utilized to determine the element positions and weight coefficients of a linear array that generates a desired beam pattern. To reduce the computational burden in the optimization procedure, an efficient numerical routine for the beam pattern evaluation has been implemented. We address the optimization problem of both dense and sparse wide-band arrays. In the first case, the goal is to minimize the side-lobe energy by varying the element weights; we compare the optimized beam pattern with that obtained with classical shading functions, showing that better results can be achieved with a wide-band optimization. We also consider the optimization of the layout (positions and weights) of a sparse linear array to achieve a desired beam pattern with a fixed or minimum number of array elements. The comparison of the proposed method with a narrow-band optimization algorithm is presented, showing that better performances (about -7 dB further reduction of the side-lobe level) can be achieved with a wide-band sparse array optimization. Further numerical simulations are given, showing that the proposed method yields better results than wide-band sparse random arrays and periodic arrays with the same aperture width.

Journal Article↗

On optimal current patterns for electrical impedance tomography.

We develop a statistical criterion for optimal patterns in planar circular electrical impedance tomography. These patterns minimize the total variance of the estimation for the resistance or conductance matrix. It is shown that trigonometric patterns (Isaacson, 1986), originally derived from the concept of distinguishability, are a special case of our optimal statistical patterns. New optimal random patterns are introduced. Recovering the electrical properties of the measured body is greatly simplified when optimal patterns are used. The Neumann-to-Dirichlet map and the optimal patterns are derived for a homogeneous medium with an arbitrary distribution of the electrodes on the periphery. As a special case, optimal patterns are developed for a practical EIT system with a finite number of electrodes. For a general nonhomogeneous medium, with no a priori restriction, the optimal patterns for the resistance and conductance matrix are the same. However, for a homogeneous medium, the best current pattern is the worst voltage pattern and vice versa. We study the effect of the number and the width of the electrodes on the estimate of resistivity and conductivity in a homogeneous medium. We confirm experimentally that the optimal patterns produce minimum conductivity variance in a homogeneous medium. Our statistical model is able to discriminate between a homogenous agar phantom and one with a 2 mm air hole with error probability (p-value) 1/1000.

Algorithms↗

Optimization of physical parameters for exo-biopolymer production in submerged mycelial cultures of two entomopathogenic fungi Paecilomyces japonica and Paecilomyces tenuipes.

AIMS: In the present study, two different optimization techniques were used to determine the suitable operating parameters for exo-biopolymer production in submerged mycelial cultures of two entomopathogenic fungi Paecilomyces japonica and Paecilomyces tenuipes. METHODS AND RESULTS: First, the rotating simplex method, a nonstatistical optimization technique, was employed to obtain the best combination of physical parameters (viz. pH, agitation intensity, aeration rate) for maximum exo-biopolymer production by P. japonica in a batch bioreactor. The optimal combination was determined to be a pH of 8.06, an aeration of 3 vvm, without any impeller agitation, producing a 17-time increase in exopolymer production (34.5 g l(-1)) when compared with that achieved in unoptimized flask cultures. Second, the uniform design method, a statistical optimization technique, was employed to determine the best operating parameters for submerged culture of P. tenuipes. The optimal combination for mycelial growth was determined to be a pH of 4.88, an aeration of 2 vvm and an agitation of 350 rpm, while a pH of 4, an aeration of 2 vvm and an agitation of 150 rpm was best for exo-biopolymer production. CONCLUSIONS: The exo-biopolymer production in P. japonica optimized by the rotating simplex method was strikingly improved (max. 34.5 g l(-1)), and the exo-biopolymer production in P. tenuipes optimized by the uniform design method was also significantly increased (max. 3.4 g l(-1)). SIGNIFICANCE AND IMPACT OF THE STUDY: The successful application of these two different optimization techniques in this study implies that these methods are worthy of applying to other fermentation systems for the production of bioactive mycelial biomass and exo-biopolymers in liquid culture of higher fungi.

Biomass↗

Long-term variations in optimal programming of cardiac resynchronization therapy devices.

The optimal follow-up and long-term programming of cardiac resynchronization therapy (CRT) devices are uncertain. The aim of this study was to quantify the temporal variations in programming parameters to optimize the follow-up of these devices. Before, during, and at specified intervals over 9 months after implant, 40 recipients of CRT devices were studied. At each visit, the patients were tested with a fixed sequence of stimulation parameters during echocardiographic and electrocardiographic (ECG) recordings. The optimal AV delay and inter-ventricular delays (V-V) were determined according to echocardiographic criteria. The echocardiographic data were, in turn, compared with the ECG recordings. Among the 40 patients, the optimal stimulation parameters remained unchanged throughout the follow-up in only three patients. In 18 patients, adjustments were required at each follow-up sessions. There was a trend toward reduction in the left ventricular (LV) predominance of the optimal V-V delay and an increase in the AV delay during follow-up. The mean optimal V-V delay at implant was 22 ms (-12 to +32 ms) with the LV activated first, versus 12 ms (-16 to +32 ms) at 9 months. The mean AV delay at implant was 115 ms versus 137 ms at 9 months. Individual changes could not be accurately predicted. The optimal stimulation parameters for CRT vary over time. Detailed, regular reevaluations, and reprogramming of optimal parameters may be appropriate.

Cardiac Pacing, Artificial↗

A dose-volume histogram based optimization algorithm for ultrasound guided prostate implants.

The task of treatment planning for prostate implants is to find an optimal seed configuration, comprising the target coverage and dosimetric consideration of critical structures such as the rectum and urethra. An efficient method to accomplish this is to use an inverse planning technique that derives the optimized solution from a prescribed treatment goal. The goal can be specified in the voxel domain as the desired doses to the voxels of the target and critical structures, or in the dose volume representation as the desired dose volume histograms (DVHs) of the target and critical structures. The DVH based optimization has been successfully used in plan optimization for intensity-modulated radiation therapy (IMRT) but little attention has been paid to its application in prostate implants. Clinically, it has long been known that some normal structure tolerances are more accurately assessed by volumetric information. Dose-volume histograms are also widely used for plan evaluation. When working in the DVH domain for optimization one has more control over the final DVHs. We have constructed an objective function sensitive to the DVHs of the target and critical structures. The objective function is minimized using an iterative algorithm, starting from a randomly selected initial seed configuration. At each iteration step, a trial position is given to a randomly selected source and the trial position is accepted if the objective function is decreased. To avoid being trapped in a less optimal local minimum, the optimization process is repeated. The final plan is selected from a pool of optimized plans obtained from a series of randomized initial seed configurations.

Algorithms↗

Optimized dynamic rotation with wedges.

Dynamic rotation is a computer-controlled therapy technique utilizing an automated multileaf collimator in which the radiation beam shape changes dynamically as the treatment machine rotates about the patient so that at each instant the beam shape matches the projected shape of the target volume. In simple dynamic rotation, the dose rate remains constant during rotation. For optimized dynamic rotation, the dose rate is varied as a function of gantry angle. Optimum dose rate at each gantry angle is computed by linear programming. Wedges can be included in the optimized dynamic rotation therapy by using additional rotations. Simple and optimized dynamic rotation treatment plans, with and without wedges, for a pancreatic tumor have been compared using optimization cost function values, normal tissue complication probabilities, and positive difference statistic values. For planning purposes, a continuous rotation is approximated by static beams at a number of gantry angles equally spaced about the patient. In theory, the quality of optimized treatment planning solutions should improve as the number of static beams increases. The addition of wedges should further improve dose distributions. For the case studied, no significant improvements were seen for more than 36 beam angles. Open and wedged optimized dynamic rotations were better than simple dynamic rotation, but wedged optimized dynamic rotation showed no definitive improvement over open beam optimized dynamic rotation.

Humans↗

Neural networks for the optimization of crude oil blending.

Crude oil blending is an important unit in petroleum refining industry. Many blend automation systems use real-time optimizer (RTO), which apply current process information to update the model and predict the optimal operating policy. The key unites of the conventional RTO are on-line analyzers. Sometimes oil fields cannot apply these analyzers. In this paper, we propose an off-line optimization technique to overcome the main drawback of RTO. We use the history data to approximate the output of the on-line analyzers, then the desired optimal inlet flow rates are calculated by the optimization technique. After this off-line optimization, the inlet flow rates are used for on-line control, for example PID control, which forces the flow rate to follow the desired inlet flow rates. Neural networks are applied to model the blending process from the history data. The new optimization is carried out via the neural model. The contributions of this paper are: (1) Stable learning for the discrete-time multilayer neural network is proposed. (2) Sensitivity analysis of the neural optimization is given. (3) Real data of a oil field is used to show effectiveness of the proposed method.

Industry↗

Matching between feline left ventricle and arterial load: optimal external power or efficiency.

We tested the hypothesis that the feline left ventricle normally works at optimal external power as opposed to optimal efficiency by (re)analyzing data from five isolated, blood-perfused cat hearts and 39 open-thorax cats. In the isolated hearts, we measured pump function, external steady power, myocardial oxygen consumption, and efficiency. Optimal external power and optimal efficiency were found at different left ventricular outputs (6.94 +/- 0.33 and 8.35 +/- 0.37 ml/s, respectively; P less than 0.001). In the in situ cat hearts the working point was found at an output of 4.72 +/- 0.32 ml/s, whereas optimal external power was found at 4.84 +/- 0.26 ml/s. These values were not significantly different. Assuming that the point of optimal efficiency was located at the same fraction of the maximal unloaded left ventricular output (Fmax) as in the isolated hearts, i.e., 0.7, we found the point of optimal efficiency for the in situ heart at a flow of 5.83 +/- 0.32 ml/s, which was significantly different (P less than 0.001) from the flow in the working point. Our data therefore indicate that the left ventricle in the open-thorax cat is matched to the arterial load such that its external power output rather than efficiency is optimized.

Algorithms↗

Signal-averaged electrocardiogram. Improved identification of patients with ventricular tachycardia using a 28-lead optimal array.

BACKGROUND: Although the signal-averaged ECG (SAECG) is currently the best noninvasive test to identify patients with ventricular tachycardia (VT) following myocardial infarction (MI), it is still a relatively insensitive test. Body surface mapping has improved the sensitivity of ECG in detecting various cardiac diseases. This study applied body surface mapping to the SAECG in the form of a clinically practical, 28-lead optimal array and compared its sensitivity and specificity with those of an orthogonal array. METHODS AND RESULTS: Two hundred twenty-three patients with previous MI (82 with inducible VT) underwent SAECG using 28 surface electrodes from which were obtained a three-lead orthogonal array and a 28-lead optimal array (optimal). From the orthogonal array, two QRS durations (QRSd) were obtained using the combined vector magnitude method (CVM) and the earliest onset to latest offset of the three individually filtered leads (individual). From the optimal array, 28 QRSd were obtained, each defined as the duration from the earliest onset of any of the 28 leads to the offset of each individually filtered lead. QRSd > 120 msec in > or = 3 leads was considered abnormal. For CVM and individual, QRSd of > 120 msec were considered abnormal. While the specificity of each method was comparable (84%, 86%, and 84% for CVM, individual, and optimal, respectively), the sensitivity of optimal (70%) was significantly greater than the sensitivity of CVM (54%) (p = 0.001) or individual (59%) (p = 0.004). The magnitude of improvement in sensitivity, 16% and 15%, respectively, was equal for anterior (n = 120) and inferior (n = 103) infarctions. CONCLUSIONS: Body surface mapping using the 28-lead optimal array significantly improved the sensitivity of the SAECG without loss of specificity. The increased sensitivity was of equal magnitude for inferior and anterior infarctions. The superiority and practicality of the 28-lead optimal array make it worth pursuing as an option for further refinement in SAECG:

Aged↗

Evaluation of nonlinear optimization for scheduling of follow-up cystoscopies to detect recurrent bladder cancer. The Bladder Cancer follow-up Group.

Standard recommendations for patients who have had superficial bladder cancer are inspection by cystoscopy quarterly for a year or two after tumor removal, then half-yearly and yearly. The authors assessed the potential for improvement in scheduling cystoscopies according to probabilistic optimization techniques. Eight hypothetical practices were created, based on retrospective analysis of 918 bladder-cancer-patient charts. Standard and alternative recommendations for the interval to next cystoscopy were compared. The alternatives were derived from patient-specific predictions of future tumor risks (based on the patient's prior recurrence rate and tumor stage and grade) and a nonlinear optimization approach to allocation of the same number of cystoscopies as were available for standard follow-up. The optimization proposed longer intervals between visits for low-risk patients and shorter intervals for high-risk patients. Overall, optimization reduced expected tumor detection delays by 30%, from 12.6 to 8.7 weeks. When optimization intervals were shorter than standard, cancer was found more often at subsequent cystoscopies (34% vs 27%, p less than 0.05), suggesting that the optimization was a better predictor of cancer recurrence. If reduction in tumor-detection delay is the goal of follow-up for recurrent cancers, then urologists can improve monitoring by using probabilistic optimization methods for scheduling cystoscopies. Further understanding of the accuracy of predictive models for bladder-cancer recurrence rates is desirable. Subsequently, the optimization method developed here may be tested prospectively.

Aftercare↗

Optimal wave-front reconstruction strategies for multiconjugate adaptive optics.

We propose an optimal approach for the phase reconstruction in a large field of view (FOV) for multiconjugate adaptive optics. This optimal approach is based on a minimum-mean-square-error estimator that minimizes the mean residual phase variance in the FOV of interest. It accounts for the C2n profile in order to optimally estimate the correction wave front to be applied to each deformable mirror (DM). This optimal approach also accounts for the fact that the number of DMs will always be smaller than the number of turbulent layers, since the C2n profile is a continuous function of the altitude h. Links between this optimal approach and a tomographic reconstruction of the turbulence volume are established. In particular, it is shown that the optimal approach consists of a full tomographic reconstruction of the turbulence volume followed by a projection onto the DMs accounting for the considered FOV of interest. The case where the turbulent layers are assumed to match the mirror positions [model-approximation (MA) approach], which might be a crude approximation, is also considered for comparison. This MA approach will rely on the notion of equivalent turbulent layers. A comparison between the optimal and MA approaches is proposed. It is shown that the optimal approach provides very good performance even with a small number of DMs (typically, one or two). For instance, good Strehl ratios (greater than 20%) are obtained for a 4-m telescope on a 150-arc sec x 150-arc sec FOV by using only three guide stars and two DMs.

Journal Article↗

Optimization of photonic crystal structures.

We report on the numerical structural optimization of two-dimensional photonic crystal (PhC) power dividers by using two different classes of optimization algorithms, namely, a modified truncated Newton (TN) gradient search as deterministic local optimization scheme and an evolutionary optimization representing the probabilistic global search strategies. Because of the severe accuracy requirements during optimization, the proper PhC device has been simulated by using the multiple-multipole program that is contained in the MaX-1 software package. With both optimizer classes, we found reliable and promising solutions that provide vanishing power reflection and perfect power balance at any specified frequency within the photonic bandgap. This outcome is astonishing in light of the discrete nature inherent in the underlying PhC structure, especially when the optimizer is allowed to intervene only within a very small volume of the device. Even under such limiting constraints structural optimization is not only feasible but has proven to be highly successful.

Journal Article↗