At least 325 records · Page 18Linked to original sources

Evaluation of patient and staff doses during various CT fluoroscopy guided interventions.

As CT scanners are more routinely used as a guidance tool for various types of interventional radiological procedures, concern has grown for high patient and staff doses. CT fluoroscopy provides the physician immediate feedback and can be a valuable tool to dynamically assist various types of percutaneous interventions. However, the fixed position of the scanning plane in combination with high exposure factors may lead to high cumulative patient skin doses that can reach deterministic threshold limits. The staff is also exposed to a considerable amount of scatter radiation while standing next to the patient during the procedures. Although some studies have been published dealing with this subject, data of patient skin doses determined by direct in vivo dosimetry remains scarce. The purpose of this study is to quantify and to evaluate both patient and staff doses by direct thermoluminescent dosimetry during various clinical CT fluoroscopy guided procedures. Patient doses were quantified by determining the entrance skin dose with direct thermoluminescent dosimetry and by estimating the effective dose (E). Staff doses were quantified by determining the entrance skin dose at the level of the eyes, thyroid, and both the hands with direct thermoluminescent dosimetry. For a group of 82 consecutive patients, the following median values were determined (data per procedure): patient E (19.7 mSv), patient entrance skin dose (374 mSv), staff entrance skin dose at eye level (0.21 mSv), thyroid (0.24 mSv), at the left hand (0.18 mSv), and at the right hand (0.76 mSv). The maximum recorded patient entrance skin dose stayed well below the deterministic threshold level of 2 Gy. Poor correlation between both patient/staff doses and integrated procedure mAs emphasizes the need for in vivo measurements. CT fluoroscopy doses are markedly higher than classic CT-scan doses and are comparable to doses from other interventional radiological procedures. They consequently require adequate radiation protection management. An important potential for dose reduction exists by limiting the fluoroscopic screening time and by reducing the tube current (mA) to a level sufficient to provide adequate image quality.

Adolescent↗

Fine wire frame-assisted intramedullary nailing of the tibia.

Intramedullary nailing is accepted as the technique of choice for treatment of unstable tibial diaphyseal fractures. Indirect closed reduction must first be obtained to allow passage of the guide wire and reamers. We describe the use of a simple frame that allows precise reduction, control of rotation and easy imaging access, without increasing operating or screening time.

Bone Nails↗

Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion.

STUDY DESIGN: An experimental model for the assessment of patient dose and associated radiogenic risks associated with pedicle screw internal fixation surgical procedures. OBJECTIVES: To provide data for the accurate determination of patient effective dose, gonadal dose, and entrance skin dose from fluoroscopically assisted pedicle screw insertion procedures and to investigate the potential of both stochastic and deterministic radiogenic effects to occur following such procedures. SUMMARY OF BACKGROUND DATA: There is increased concern on radiation exposure of patients undergoing fluoroscopically guided interventional procedures. METHODS: The cumulative screening time and dose area product, for each fluoroscopic projection used, were monitored in 20 patients undergoing pedicle screw internal fixation. The dose absorbed by each radiosensitive organ/tissue was determined from direct measurements obtained using an anthropomorphic phantom appropriately loaded with thermoluminescence dosimeters. RESULTS: An average pedicle screw insertion procedure requires 1.2 minutes and 2.1 minutes of fluoroscopic exposure along anteroposterior and lateral projections, respectively, resulting in a dose area product of 232 cGy cm and 568 cGy cm, correspondingly. Gender-specific normalized data for the determination of effective, gonadal, and entrance skin dose to patients undergoing fluoroscopically guided pedicle screw internal fixation procedures were derived. The effective dose from an average procedure was 1.52 and 1.40 mSv and the gonadal dose 0.67 and 0.12 mGy for female and male patients, respectively. The average radiogenic risks for fatal cancer and genetic defects were 115 and 4 per million of patients treated, respectively. Induction of skin injuries might be induced when fluoroscopy along the lateral projection is highly extended and the source to skin distance is kept low. CONCLUSIONS: Patient dose and radiogenic risks associated with an average pedicle screw internal fixation procedure are tolerable. However, for young patients with complex spinal disorders requiring extended fluoroscopy, radiogenic risks may be considerable. Present data may beused for estimation of effective dose, gonadal dose, and entrance skin exposure and associated radiogenic risks to patients undergoing fluoroscopically guided pedicle screw insertion in any institution.

Adult↗

Fermions obstruct dimensional reduction in hot QCD

We have studied, for the first time, screening masses obtained from glueball-like correlators in quantum chromodynamics with four light dynamical flavors of quarks in the temperature range 1. 5T(c)</=T</=3T(c), where T(c) is the temperature at which the chiral transition occurs. We have also studied pionlike and sigmalike screening masses and found that they are degenerate in the entire range of T. These obstruct perturbative dimensional reduction since the lowest glueball screening mass is heavier than them. Extrapolation of our results suggests that this obstruction may affect the entire range of temperature expected to be reached even at the Large Hadron Collider.

Journal Article↗

Premature ejaculation in non-insulin-dependent diabetic patients.

Aim of the study was to assess the prevalence and to analyse risk factors for premature ejaculation (PE) in patients with non-insulin-dependent diabetes. A total of 676 male diabetic patients were enrolled in this study. Patients were screened for PE. At the screening time, patients were also interviewed for sociodemographic data that included age, education, occupation and marital status. Medical history included diabetes, duration of diabetes and diabetes-related complications. Clinical and laboratory assessment included body mass index and glycosylated haemoglobin. Mean age for the study sample was 53.4 +/- 10.4 years. The prevalence of PE was 32.4% in patients below 50 years, which increased to 67.6% in patients above 50 years. Of patients without PE, 31.4% were below 50 years compared with 68.6% above 50 years of age (p > 0.05). Patients with >10 years of diabetes were 2.7 times as likely to report PE as men with diabetes of <5 years (p < 0.05). Men with poor metabolic control were 9.6 times as likely to report PE as those with good metabolic control (p < 0.05). Patients without PE were four times as likely to have normal erectile function as those with PE (p < 0.05). There was a significant association between PE and cardiovascular diseases (p < 0.05). PE is common among diabetic patients. The study offers a quantitative estimate of the prevalence of PE and its main risk factors in diabetic patients.

Adult↗

Heparin-induced thrombocytopenia following pancreatectomy and islet auto-transplantation.

We report the case of a female with chronic pancreatitis who underwent multiple surgical procedures leading to total resection of the pancreas with successful islet auto-transplantation. Postoperatively, she developed heparin-induced thrombocytopenia. Heparinization prior to islet infusion is currently recommended to prevent portal vein thrombosis. Antibodies against heparin are not standard pre-operative testing for islet transplantation. Timely screening for heparin-dependent anti-platelet antibody should be kept in consideration for elective surgical cases (especially following previous surgeries) including pancreatic islet allo- and auto-transplantation.

Adult↗

Evaluation of radiation dose and risk to the patient from coronary angiography.

BACKGROUND: Coronary angiography is a commonly performed diagnostic procedure with life saving benefits for the patient. However, because of its potential to deliver a high radiation dose, caution is warranted. AIM: The purpose of this study was to determine the effective dose to an average patient from coronary angiography, to estimate the associated radiation risk in terms of fatal malignancy, and to examine ways effective dose may be reduced. METHOD: The dose-area product data from 210 examinations was used to determine the effective dose to the average patient by means of a commercially available software programme. Subsequently, the effective dose was used to estimate radiation risk based on the population averaged probability coefficients given in ICRP 60 and contrasted against age-related risk coefficients from the NRPB. The components of effective dose and radiation risk were examined to identify the organs most at risk. RESULTS: The average effective dose was found to be 3.4 +/- 1.3 mSv. The risk of fatal malignancy was estimated as 170 per million cases, or around one in 6000. The average lung dose was 14.7 mSv, with the risk of fatal lung cancer estimated as 125 per million cases or one in 8000. CONCLUSIONS: The average effective dose in this study was less than half that of most other studies. The lung was identified as the critical organ and the estimated risk of fatal cancer amounted to an increase of 0.017% above the normal incidence for the general population. The study affirmed that using a reduced cine frame rate, low dose pulsed fluoroscopy, added copper filtration and a conscious effort to reduce screening time can significantly reduce patient dose.

Adult↗

Visual search in typically developing toddlers and toddlers with Fragile X or Williams syndrome.

Visual selective attention is the ability to attend to relevant visual information and ignore irrelevant stimuli. Little is known about its typical and atypical development in early childhood Experiment 1 investigates typically developing toddlers' visual search for multiple targets on a touch-screen. Time to hit a target, distance between successively touched items, accuracy and error types revealed changes in 2- and 3-year-olds' vulnerability to manipulations of the search display. Experiment 2 examined search performance by toddlers with Fragile X syndrome (FXS) or Williams syndrome (WS). Both of these groups produced equivalent mean time and distance per touch as typically developing toddlers matched by chronological or mental age; but both produced a larger number of errors. Toddlers with WS confused distractors with targets more than the other groups; while toddlers with FXS perseverated on previously found targets. These findings provide information on how visual search typically develops in toddlers, and reveal distinct search deficits for atypically developing toddlers.

Attention↗

Effects of transvenous pacing on cardiac troponin release.

Cardiac troponins are invaluable tools for the detection of minimal myocardial injury. No study to date has analyzed the effect of permanent cardiac pacing on minimal myocardial injury detection by cardiac troponin I (cTnI) measurement. We investigated 76 clinically stable patients (mean age 75 years, range 31-93 years, 59% men) listed for elective endocardial permanent pacemaker insertion. Patients were required to have normal levels of cardiac cTnI, aspartate transaminase (AST) and creatinine kinase (CK) on a venous blood sample taken immediately prior to elective pacemaker implantation. Repeat measurements of AST, CK, and cTnI were performed at a mean of 19.2 post implantation. There was a detectable small rise in cTnI levels above normal in 21% of patients in a second blood sample taken 18-21 hours later (mean cTnI 0.39 +/- 0.37 microg/L, normal < 0.15 microg/L). The only factor that correlated with this rise was prolonged x ray screening time for lead implantation.

Adult↗

Conceptus radiation dose assessment from fluoroscopically assisted surgical treatment of hip fractures.

Our aims in the present study were to (a) provide normalized dose data for the estimation of the conceptus dose from fluoroscopically assisted surgical treatment of hip fractures carried out during all trimesters of pregnancy and (b) estimate the conceptus radiation dose and risks associated with fluoroscopy during a typical treatment of hip fracture performed on a pregnant woman. Conceptus doses normalized to entrance surface dose (ESD) or dose area product (DAP) were obtained with the help of anthropomorphic phantoms simulating pregnancy in the three trimesters of gestation. ESD and conceptus dose measurements were carried out using thermoluminescent dosimeters. DAP to conceptus dose conversion factors were estimated for the first, second and third trimesters of gestation. Conceptus dose data normalized to ESD were also estimated to investigate whether these conversion factors may be used for procedures carried out in x-ray units not equipped with a DAP meter. Fluoroscopically assisted surgical treatments were performed in 18 women. The projections involved in these procedures are (a) posteroanterior (PA) and (b) lateral crosstable 45 degrees (LC). Radiation doses for a potential conceptus were estimated by using normalized dose data obtained in phantoms. The results consist of tabulated dose data normalized to DAP or ESD for the estimation of a conceptus dose. An important finding of this study was that the total DAP of a procedure, instead of the individual DAP values of each projection, could be used for the accurate estimation of the conceptus dose. Conceptus doses calculated using dose data normalized to ESD are about 23% higher compared to those estimated using data normalized to DAP. This discrepancy may be attributed to the contribution of scattering radiation from PA projection to ESD measurement of LC projection and vice versa. Therefore, dose data normalized to ESD do not provide accurate conceptus dose estimation. Doses normalized to DAP showed a dependence on (a) tube potential and (b) tube filtration. Data are provided to extent the doses normalized to DAP for the standard spectrum to other tube voltages and filtrations. The maximum dose for a potential conceptus was 0.425 mGy for a patient irradiated for 50 seconds during the PA projection and for 40 seconds during the LC projection. Although the total duration of fluoroscopy is usually less than 2 minutes during a typical procedure, screening time as long as 14 minutes has been reported in the literature for treatment of complex fractures. The relationship between conceptus dose and fluoroscopy time found in the current study showed that, in these cases, the radiation dose received by a conceptus may exceed 1 mGy. In conclusion, an accurate estimation of conceptus doses associated with fluoroscopically assisted surgical treatment of hip fractures can be made using the DAP normalized dose data provided in this study. Conceptus doses from a typical procedure is less than 1 mGy during all trimesters.

Dose-Response Relationship, Radiation↗

Excretion of myoglobin in urine after cardiac catheterisation.

Myoglobin levels were assayed in each urine specimen voided during 12 hours before and 48 hours after routine cardiac catheterisation in 146 patients using an indirect haemagglutination method detecting concentrations in excess of 0.015 mg/ml. Myoglobinuria was found in only one patient before but in 39 patients after cardiac catheterisation (27%), either in the first (34 patients) or the second (5 patients) post-catheterisation urine sample. Once detected, myoglobin was present in all subsequent urine specimens for the next 3 to 22 hours (mean 11.8 hours). The mean amount excreted +/- SE was 14.0 +/- 1.6 mg (range 2.6 to 30 mg) excluding the one patient with myoglobinuria before catheterisation. This patient, who had severe aortic stenosis and atherosclerotic heart disease, excreted 130 mg myoglobin. Patients with myoglobinuria required longer screening time to complete the procedures undertaken than those in whom myoglobin was not detected--15.6 +/- 1.4 and 11.1 +/- 0.6 minutes, respectively (mean +/- SE:P less than 0.01). We conclude that myoglobinuria is not uncommon after cardiac catheterisation, and that though the myoglobin detected may be released from skeletal muscle, it could be partly or wholly of cardiac origin and indicate transient, and presumably reversible, myocardial injury.

Cardiac Catheterization↗

Cost efficiency analysis of modern cytocentrifugation methods versus liquid based (Cytyc Thinprep) processing of urinary samples.

BACKGROUND/AIMS: Liquid based cytology (LBC) was developed as a replacement for cytocentrifugation in the treatment of cell suspensions. Because accurate data comparing the quality and total cost of modern cytocentrifugation methods versus LBC in non-gynaecological samples are not available, this study was designed to investigate these issues. METHODS: The study comprised 224 urine samples treated with the Thermo Shandon Cytospin 4 using reusable TPX chambers, disposable Cytofunnels for samples up to 0.5 ml, and disposable Megafunnels for samples up to 6 ml. Each method was compared with the Cytyc Thinprep processing of a paired sample. Quality was assessed by scoring cellularity, fixation, red blood cells, leucocytes, abnormalities of urothelial cells, and suitability for molecular studies. Wage costs, investment, and consumables allowed a "total cost" to be calculated on the basis of 200 specimens/month. Total cost and quality combined were used to calculate an index of total quality (ITQ). RESULTS: Cytocentrifugation with disposable chambers resulted in a global quality superior to that of Cytyc Thinprep LBC. Preparation and screening times were 2.25 and 1.33-2 times greater when using LBC compared with cytocentrifugation. The total cost each month reached 1960.23 $ to 2833.43 $ for cytocentrifugation methods and 5464.95 $ for Cytyc Thinprep LBC (92.8-178.8% increased cost). ITQ of cytocentrifugation with disposable chambers surpassed that of Cytyc Thinprep LBC (37.25/32.08 and 9.98, respectively). CONCLUSION: Cytyc Thinprep LBC and cytocentrifugation are both appropriate methods for cytology based molecular studies, but cytocentrifugation remains the quality standard for current treatment of urinary samples because of its lower cost.

Centrifugation↗

Alterations of the CARD15/NOD2 gene and the impact on management and treatment of Crohn's disease patients.

The recent identification of the CARD15/NOD2 gene as a susceptibility locus for Crohn's disease represents an important step towards the delineation of the immunopathogenesis of inflammatory bowel disease. CARD15 functions as an intracellular receptor for bacterial components and thus represents an important link between inflammatory bowel disease and innate immunity. Three major CARD15/NOD2 gene mutations have been associated with Crohn's disease in Caucasians in several independent studies. Together, they explain about 20% of the genetic susceptibility for Crohn's disease. Genotype-phenotype analyses demonstrated an association of these mutations with ileum-specific disease, an increased incidence of the fibrostenotic phenotype and an earlier age of disease onset. Beside these associations, no other relationship between the CARD15/NOD2 genotype and disease behavior or response to treatment has been detailed so far. Thus, the clinical impact of knowing the patient's genotype is limited at this time. Screening for CARD15 mutations in order to identify high-risk individuals or to introduce an individualized disease management is therefore currently not recommended.

Apoptosis↗

Kondous laventicus, a new ceboid primate from the Miocene of the La Venta, Colombia, South America.

A new genus and species of fossil primate, Kondous laventicus, part of the Miocene La Venta primate fauna of Colombia, South America, is described here for the first time. Screening at a new quarry within the Monkey Unit of the Honda Formation, the Kyoto Site, has revealed dental remains of this new form of a large-sized ceboid. The La Ventan vertebrate fauna is comparable to the Friasian Land Mammal Age, indicating a middle Miocene age. Biostratigraphic studies suggest a 13.6-15.2 Ma for the Friasian faunal zone. Kondous is most closely allied to extant spider monkeys, Ateles, providing the first fossil evidence of their phylogeny. It also implies a nearly three-fold discrepancy between the molecular and paleontological estimates of the age of the Ateles lineage.

Animals↗

Compact cell blocks. Use for body fluids, fine needle aspirations and endometrial brush biopsies.

OBJECTIVE: To obtain an ideal cell block wherein the maximal number of cells are displayed within the smallest area on the block surface. STUDY DESIGN: Cyto-Rich Red (AutoCyte, Inc., Elon College, North Carolina, U.S.A.) is added to fresh cellular sediment in a centrifuge tube at a ratio of 1:1. After two minutes, three to four drops of plasma and topical thrombin (5,000 U/10 mL) is added. The tube is then gently agitated for two minutes, until a gelatinous clot is obtained. The clot is then slid onto a lens tissue on top of paper towels. The lens tissue is folded once over the clot. By gently squeezing the excess fluid from it through the lens tissue into the paper towels, the clot is transformed into a flat, compact, densely cellular aggregate, which is painted with mercurochrome prior to fixation in formaldehyde. RESULTS: From each of the 495 cases, including 250 body cavity fluids, 170 fine needle aspirates and 75 endometrial brush biopsies, processed with the above protocol, there was a compact cell block containing packed cells or tissue fragments in a clean background devoid of red blood cells. CONCLUSION: The compact cell block is about 10-20% the size of a conventional cell block, yet more cells are on display, thus reducing the need for deeper cuts and screening time while increasing the efficiency of cytodiagnosis. The compact cell block technique is particularly helpful for endometrial brush biopsies.

Biopsy↗

Evaluation of the PAPNET system for prescreening triage of cervicovaginal smears.

OBJECTIVE: To assess the PAPNET System for prescreening triage of cervical smears. STUDY DESIGN: We prospectively prescreened 5,170 consecutive cervicovaginal smears with the PAPNET System. The slides were then manually screened by cytotechnologists blinded to the PAPNET diagnoses. Cases identified as abnormal by either PAPNET or manual screening were reviewed by a cytopathologist. The PAPNET and manual diagnoses were correlated. RESULTS: Diagnostic concordance between PAPNET and manual screening was seen in 4,340 (84%) of the cases (3,167 negative, 1,038 abnormal and 135 unsatisfactory). Noncorrelation between PAPNET and manual diagnosis occurred in 794 cases (543 abnormal by PAPNET and negative manually, 228 negative by PAPNET and abnormal manually, 8 abnormal by PAPNET and unsatisfactory manually, 29 unsatisfactory by PAPNET and negative manually, 7 negative by PAPNET and unsatisfactory manually). The diagnostic sensitivity of the PAPNET System was 82%, diagnostic specificity 85%, predictive value of a positive test 66% and predictive value of a negative test 93.4%. The false negative fraction of PAPNET was 6.4% for low grade squamous intraepithelial lesion and above. CONCLUSION: PAPNET performed effectively for prescreening triage, increasing the accuracy of screening and reducing the screening time.

Evaluation Studies as Topic↗

Saccomanno smear slides and Megafunnel slides for sputum specimens. A comparison.

OBJECTIVE: To compare Megafunnel slides to standard Saccomanno smear slides of sputum specimens and evaluate the use of Megafunnel slides for retrospective studies. STUDY DESIGN: Papanicolaou-stained Saccomanno smear and Megafunnel slides (Shandon Lipshaw, Inc., Shandon Inc., Pittsburgh, Pennsylvania, U.S.A.) of 65 clinical sputum specimens from 51 patients were compared for cellular morphology, staining, background and cytologic diagnosis. Recovery of diagnostic cells was quantitated using 10 of these specimens. Megafunnel slides prepared from the clinical sputum samples were immunocytochemically stained. Diagnostic cells were quantitated both before removal from 64 archived Saccomanno smear slides and after placement of these cells onto 238 Megafunnel slides. RESULTS: Saccomanno smear slides and Megafunnel slides of clinical specimens were similar in morphology, background, staining, diagnosis and cell recovery. Megafunnel slides were superior for multiple immunocytochemical stains. The production of multiple Megafunnel slides from archival smear slides provided a method of performing numerous retrospective studies. CONCLUSION: Megafunnel slides compared favorably to Saccomanno smear slides in the quality of specimens but are more expensive and labor intensive to prepare. However, the reduction in screening time by cytotechnologists may be advantageous. Additionally, their potential use for immunocytochemistry, fluorescence in situ hybridization, or other special clinical and research analyses is very promising.

Antibodies↗

Measuring radiation exposure during percutaneous drainages: can shoulder dosemeters be used to estimate finger doses?

Some previous studies have shown remarkably high finger doses to radiologists performing percutaneous drainage under fluoroscopy. To assess the possible need for extra finger dosemeters in addition to the general dosemeter, radiologists' and assistants' radiation exposure at both shoulders and at the third fingers of both hands were recorded using thermoluminescent dosemeters during 27 interventional drainage procedures. Under couch screening was used. Mean dose rates were calculated by dividing the doses by the screening time. The dose rates for the sites measured were correlated with each other. The radiologists' bilateral finger dose rates did not correlate with each other; nor did dose rates between the left shoulder and the right hand. The radiologists' dose rates at both shoulders, however, correlated with each other, as did the shoulder dose rates with the dose rates at the ispilateral hand. The right shoulder dose rates correlated with the left hand dose rates. The assistants' dose rates at the places of measurement all showed significant correlations with each other. It is therefore concluded that radiologists involved in percutaneous drainages should use finger dosemeters on both hands; for assistants this may not be necessary.

Drainage↗