PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Digital subtraction angiography for arteriovenous malformations in stereotactic radiosurgery.

Images coming from digital subtraction angiography (DSA) are affected by a perspective distortion due to the use of image intensifiers. As a result, DSA cannot be used for the accurate definition of stereotactic coordinates. A correction method has been developed to enable the use of DSA for the radiosurgery of arteriovnous malformations. A software program and a special phantom tool were employed. The phantom is made by a computer-controlled drilling machine which makes holes in a Plexiglas plate. It has 865 calibration steel spheres with coordinates determined with a precision of 0.01 mm. A calibration image is acquired by a personal computer, and the software calculates the transformation algorithm to superimpose the image on the known positions of the phantom. This algorithm is saved and then recalled to transform the diagnostic images.

Angiography, Digital Subtraction↗

Organ doses from cardiac and carotid digital subtraction angiography.

Estimates of mean organ doses from cardiac and carotid digital subtraction angiography (DSA) are obtained from measurements done using a Rando-Alderson tissue-equivalent phantom. Thermoluminescent dosemeter chips and discs were calibrated and used for all measurements in the primary and scattered radiation fields. Skin doses as well as mean doses received by the thyroid, lung, lens of the eye, breast, uterus and the ovaries were measured. A 30 degree right anterior oblique (RAO) cardiac DSA study produces a beam entrance dose of about 121 mGy at a rate of 0.48 mGy/frame. The highest mean organ dose from cardiac DSA was to the lung with a value of 14.4 mGy. The rest of the organs received doses below 1 mGy. In carotid DSA, the mean entrance doses resulted from the RAO, left anterior oblique, and the Towne's view projections give an average of 168 mGy at a rate of 8.4 mGy/frame. The highest mean organ dose from the three projections, 21 mGy, was received by the thyroid. The uterus and ovaries received the lowest doses from both procedures with values below 0.04 mGy. Patient and phantom surface exposures were compared using an exposure area product system. Hence, exposure conditions used for measuring organ doses on the phantom were adjusted to resemble those used for patients.

Angiocardiography↗

A comparison of digital subtraction angiography and noninvasive testing in the diagnosis of cerebrovascular disease.

Among the 1,892 patients who underwent cerebrovascular digital subtraction angiography at our hospital over the past 18 months, there was a subgroup of 34 patients (65 carotid arteries) for whom noninvasive cerebrovascular test results and standard cerebral arteriograms were also available. These patients were reviewed retrospectively and the ability of both methods to detect hemodynamically significant lesions, defined as a greater than 50 percent reduction in the diameter of the carotid artery, was determined using the arteriograms as the "gold standard." Noninvasive cerebrovascular tests had a sensitivity of 81 percent, a specificity of 95 percent, a positive predictive value of 92 percent, a negative prediction value of 88 percent, and an overall accuracy of 89 percent. Digital subtraction angiography had a sensitivity of 84 percent, a specificity of 92 percent, a positive predictive value of 88 percent, a negative predictive value of 89 percent, and an overall accuracy of 89 percent. If the four cases of hemodynamically significant stenosis of the carotid siphon not detected by digital subtraction angiography had been considered as false-negatives, its sensitivity would have been reduced to 72 percent. In patients with hemispheric cerebral ischemia, we found noninvasive cerebrovascular tests neither necessary nor cost-effective. Digital subtraction angiography, on the other hand, often provided definitive diagnostic information in such patients if the intracranial circulation was well defined and the extracranial lesion corresponded to the patients' symptoms. Noninvasive cerebrovascular testing was the safest and most cost-effective technique for screening patients with asymptomatic bruits, atypical, nonhemispheric cerebral symptoms, and those who have undergone carotid endarterectomy. If the noninvasive cerebrovascular test result was positive or equivocal, digital subtraction angiography was performed to localize the responsible lesion and exclude carotid occlusion.

Adolescent↗

Digital subtraction angiography in head and neck radiology.

Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

Adult↗

Evaluation of a digital subtraction angiography unit.

The operating characteristics of a digital subtraction angiography unit were evaluated. Measurements included image intensifier and system linearity, uniformity, quantum and system noise, and iodine contrast. Various approaches to noise measurement were analyzed and tested, leading to the following conclusions: the video level should be maximized; changes in signal-to-noise ratio (SNR) due to changes in x-ray exposure do not necessarily reflect changes in quantum SNR alone, due to dependence of video levels on x-ray exposure; an understanding of the separate contributions of quantum and video SNRs to the total SNR guides proper selection of variables to minimize patient dose and x-ray tube heat loading.

Angiography↗

Hybrid intravenous digital subtraction angiography of the carotid bifurcation.

A hybrid digital subtraction angiography technique and noise-reduction algorithm were used to evaluate the carotid bifurcation. Temporal, hybrid, and reduced-noise hybrid images were obtained in right and left anterior oblique projections, and both single- and multiple-frame images were created with each method. The resulting images were graded on a scale of 1 to 5 by three experienced neuroradiologists. Temporal images were preferred over hybrid images (average score = 3.2 and 2.4, respectively). The percentage of nondiagnostic examinations, as agreed upon by two readers, was higher for temporal alone than temporal + hybrid (4 and 1, respectively). In addition, also by agreement between two readers, temporal + hybrid images significantly increased the number of bifurcations seen in two views (87%) compared to temporal subtraction alone (64%).

Aged↗

Digital subtraction angiography of the extremities using table translation.

Digital subtraction angiography (DSA) of the extremities has been performed with both intravenous and intraarterial injections of contrast material. Intravenous studies are usually site specific and are limited by contrast material load; a complete intraarterial study with multiple injections of contrast material may be time consuming. A feasibility study to evaluate a DSA technique that would allow table translation and imaging of two contiguous regions following a single injection of contrast material--bolus-chase DSA--was performed. Forty-five examinations were performed, 13 intravenously and 32 intraarterially. Twelve intravenous and 16 intraarterial DSA examinations were totally satisfactory. Inadequate studies were predominantly caused by slow arterial clearance of contrast material in the distal calf and by operator error. Compared with conventional DSA, anatomic studies of lower-extremity vessels could be obtained faster and with lower contrast material loads using bolus-chase DSA.

Adult↗

Digital subtraction angiography: current clinical applications.

The applications of digital subtraction angiography (DSA) in neurologic diagnosis have been evolving as clinical experience with this technology accumulates. Initial enthusiasm with the intravenous contrast material injections has been tempered by often equivocal results. Intravenous DSA (IV-DSA) is still an accurate screening technique for extracranial carotid atherosclerosis, comparable to duplex ultrasound. Intracranial imaging is less satisfying with intravenous injections but reliable information is available in the assessment of the venous sinuses and parasellar internal arteries. The future of DSA lies with intraarterial contrast injections, as this technique substantially decreases the risks and costs of definitive cerebrovascular investigation.

Aged↗

[Diagnosis of pulmonary embolism and monitoring of post-embolic changes in the vessels using pulmonary digital subtraction angiography].

The group comprises 48 patients where digital subtraction angiography revealed embolization of the lungs. Forty-four of the patients were examined on account of clinical suspicion of embolism of the lungs, in the remaining four the examination was made on account of other indications. In four instances of 48 patients where we diagnosed or suspected embolism of the lungs DSA was also used to follow up the effect of heparinization and anti-aggregation therapy in relatively extensive findings revealed during the first examination. Based on their experience, the authors summarize angiographic pictures into four morphological types: perfusion defect, localized thinning and reduction of peripheral arterioles, sudden discontinuation of lobar and segmental arteries ("cut-off") and intraluminal defects in the contrast filling of arteries. The authors evaluate objectively the advantages and disadvantages of DSA and compare in the discussion the course of the examination, as well as the results with classical angiography, with perfusion and ventilation scan and try to find the correct place in the algorithm of visualization methods when embolism of the lungs is suspected. Based on the assembled experience, DSA of the lungs can be used as the first diagnostic method or after screening perfusion scan, if the latter is available immediately after development of complaints, as the second method. The authors analyze also the reasons of the relatively less frequent and very often late indication of this examination in this country.

Adult↗

[Arterial and venous digital subtraction angiography. A current study technic for otorhinolaryngology].

Digital subtraction angiography (DSA) is a rather new radiographic technique for imaging different vascular alterations, particularly in the head and neck area, and can replace angiography in most cases. Nevertheless, routine application of DSA - intravenously or intraarterially - seems to present a problem to many clinicists. In the present paper, therefore, we try to introduce these important techniques by means of several examples from patients who have undergone these procedures to demonstrate the actual indications of DSA for oto-rhino-laryngological diseases.

Carotid Artery Diseases↗

The significance of internal carotid artery occlusion shown by i.v. digital subtraction angiography.

A retrospective review of 493 IV digital subtraction angiography examinations performed for cervicocerebral vascular disease revealed 27 apparent occlusions of the internal carotid artery. We identified 20 patients whose occlusions did not warrant further investigation. Fourteen occlusions were on the asymptomatic side, two were in patients who preferred medical treatment, two were in patients unsuitable for carotid endarterectomy, and two patients with bihemispheric transient ischemic attacks were treated for the contralateral carotid. Four very tight stenoses were found in the other seven patients, one of whom refused endarterectomy. As the signs of a very tight stenosis are subtle, and the number of such stenoses that are treatable is low (three in 493), cerebral angiography is justified in doubtful cases to avoid missing potentially treatable lesions.

Arterial Occlusive Diseases↗

[Application of digital subtraction angiography (DSA) in the neurosurgical field].

Intraarterial digital subtraction angiography (DSA) was applied 44 times to 39 neurosurgical cases. We emphasize the advantage of DSA in relation to conventional angiography. The examination consisted of 25 aortography and 19 selective arteriography. By single small dose injection of contrast medium using DSA, aortic arch and thoracic major vessels were well visualized, so that we could obtain useful information for catheterization to the selective artery. High time resolution of DSA made possible to recognize dynamics of circulation in very short interval, especially in the case of subclavian steal syndrome and right aortic arch. Major four vessels in the cervical region could be visualized by single injection of contrast medium using DSA. Stenosis of carotid artery was recognized by DSA as well as conventional angiography. By aortic injection using DSA, circulatory dynamics of intracranial vessels including collateral circulation were recognized especially in the case of moyamoya disease. Gradual injection of small dose contrast medium reduced jet-effect of the catheter tip and enabled the selective arteriography. Real time display of DSA reduced the time required for examination and enabled repeated angiography to recognize the change of hemodynamics under the different limb position in the case of thoracic outlet syndrome.

Cerebral Angiography↗

Localization of parathyroid adenomas by digital subtraction angiography. A report of 4 cases.

Intravenous digital subtraction angiography provides an accurate but not specific method for localization of small vascular tumours. It is carried out on outpatients as an intravenous procedure and takes only 40 minutes. It appears to be eminently suited to the demonstration of parathyroid adenomas and shows that a hyperplastic parathyroid gland can produce a significant enough vascular blush to create a visible image.

Adenoma↗

Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.

BACKGROUND AND PURPOSE: Our aim was to develop 3D dynamic MR digital subtraction angiography with high temporal resolution without sacrificing spatial resolution by using sensitivity encoding for the evaluation of cerebral arteriovenous malformations. METHODS: Nineteen patients with 19 angiographically proven arteriovenous malformations (16 supratentorial and 3 infratentorial) were assessed by conventional catheter angiography and 3D dynamic MR digital subtraction angiography. A 3D contrast-enhanced gradient-echo sequence with sensitivity encoding based on a parallel imaging technique was performed and acquired 20 dynamic images, repeated 18 times every 1.7 seconds. Three-dimensional dynamic MR digital subtraction angiograms were analyzed independently by two radiologists in a blinded fashion with regard to arteriovenous malformation nidus and venous drainage. Conventional catheter angiography was used as reference. RESULTS: All MR imaging examinations were assessable. Interobserver agreement was excellent for the detection of nidus and for the evaluation of nidus size (kappa = 1 and 0.875, respectively) but moderate for the visualization of the venous drainage (kappa = 0.56). All nidi detected on conventional catheter angiography were clearly depicted on 3D dynamic MR digital subtraction angiography. The evaluation of the size of the nidus by both techniques was similar. On 3D dynamic MR angiograms, veins were correctly analyzed in 17 of 19 arteriovenous malformations. CONCLUSION: Our preliminary study demonstrates that 3D dynamic MR digital subtraction angiography using sensitivity encoding with a high spatial resolution is appropriate for the assessment of arteriovenous malformations.

Adult↗

Noninvasive investigation for renal artery stenosis: contrast-enhanced magnetic resonance angiography and color Doppler sonography as compared to digital subtraction angiography.

INTRODUCTION: The question about the most appropriate non-invasive method for detecting a renal artery stenosis (RAS) when comparing contrast enhanced magnetic resonance angiography (MRA) and color Doppler sonography (CDS) is still under discussion. Therefore we conducted a prospective study in order to evaluate both methods as compared to digital subtraction angiography (DSA). PATIENTS/METHODS: Thirtysix consecutive patients (53,9 +/- 13,7 years) with suspected RAS were investigated. MRA was performed using gadolinium for contrast enhancement. CDS was performed using a 2.5 and 3,5 MHz transducer. A peak systolic velocity (Vmax) >200 cm/sec within renal arteries and/or a side to side difference of the resistive index (RI) of >0,05 were used to discriminate stenosis. A diameter reduction of > or = 60% by DSA was considered a stenosis relevant to the patient. RESULTS: Sixty-eight main renal arteries and 9 accessory vessels were detected by DSA. Twenty main and 3 accessory arteries were found to be stenosed > or = 60%, while 4 main and 1 accessory artery presented with occlusion. MRA detected 70 renal vessels (65 main and 5 accessory arteries). Twenty-one stenosed arteries and 4 occluded vessels were correctly diagnosed by MRA. With CDS 68 renal vessels (62 main and 6 accessory arteries) could be visual- ized out of which 21 stenoses were diagnosed because of increased Vmax and 6 stenoses were detected because of a side to side difference of RI. For main renal arteries sensitivities and specificities were 96% and 86% for MRA and 96% and 89% for CDS. CONCLUSIONS: MRA and CDS are both comparable methods for detection of a renal artery stenosis > or = 60%. Despite several limitations, CDS can at the moment still be favored as a screening method.

Adult↗

Intraoperative digital subtraction angiography after thromboembolectomy: preliminary experience.

PURPOSE: To evaluate the potential influence of intraoperative digital subtraction angiography (DSA) on surgical strategy after balloon thromboembolectomy for acute lower limb ischemia. METHODS: Thirty-six consecutive patients with critical limb ischemia were treated with balloon catheter thromboembolectomy assessed by intraoperative digital subtraction angiography. The need for further intervention was determined by the surgeon based on the DSA information. Primary completion DSAs were made in every procedure; subsequent completion DSAs were performed after reinterventions at the discretion of the surgeon. RESULTS: Initial treatment in this patient group consisted of 14 embolectomies and 26 thrombectomies. From the completion DSAs of these 40 procedures, a reintervention was judged necessary in 27 (68%). Of these 27 reinterventions, 17 underwent a secondary DSA; evidence supporting a third intervention was found in 11 (64%). Overall, a total of 69 DSAs were performed in these patients. Mortality was 22% (8 patients); 38% (5) in embolectomy patients and 13% (3) in the thrombectomy cohort. Eighty-eight percent of the embolectomy survivors had an uneventful recovery, while only 25% of the thrombectomy survivors experienced an uncomplicated follow-up. In one quarter of the surviving thrombectomy patients, a surgical revascularization resulted in limb salvage; in 45%, a major amputation was the outcome. CONCLUSIONS: In this study, the completeness of balloon catheter thromboembolectomy was assessed by intraoperative DSA. As a result, 68% of the procedures required one or more reinterventions for residual lesions. Intraoperative DSA is a simple and quick technique that may be a promising adjunct to intraoperative balloon thromboembolectomy.

Angiography, Digital Subtraction↗

Digital subtraction angiography of the aortic arch.

We evaluated the utility of intravenous digital subtraction angiography (IV DSA) for diagnosing lesions of the aortic arch and great vessels in 25 patients. Digital subtraction angiography (DSA) was found useful in evaluating congenital and acquired lesions of the arch and great vessel origins, and it proved adequate for follow-up of patients who had graft replacement. Cases examined included: right aortic arch, double arch, aortic coarctation, aberrant vascular origins, aortic aneurysm and pseudoaneurysm, changes in atherosclerotic great vessels, and revascularization procedures for patients with pulmonary atresia and aortic interruption. In our experience, DSA is a useful tool for screening and following patients with aortic arch or great vessel lesions; it is often the only diagnostic imaging examination necessary.

Adult↗