PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Calibration”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

In situ calibration and evaluation of the accuracy of a waste water monitoring system.

A new method to estimate the reliability of a waste water monitoring system was developed and substantiated. To estimate the reliability means (1) to verify the representativeness of the sample fed into the monitoring system, and (2) to calibrate the detectors of the monitoring system. To verify the representativeness, test water spiked with 32P was prepared in a storage tank, and the monitoring system was operated. For all of the experiments, the radioactivity concentrations of the water fed into the monitoring system agreed well with those of the water in the storage tank at 725 +/- 45 s after the start of the sampling pump. Therefore, the representativeness was verified. Calibration was carried out with active water in the storage tank and in a specially designed calibration tank. The efficiency of a plastic scintillation detector (PSD), one of the detectors used in the monitoring system, for 32P was determined to be 4.91 +/- 0.10%. Using the calibration tank significantly reduced the cost and labor for calibration. In addition, calibration with natural potassium (40K) proved to be effective for periodic checks of the detector.

Calibration↗

Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

RATIONALE AND OBJECTIVES: To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS: Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers were detected by using a Hough transform and were computed at subpixel precision by using either a novel, iterative center-of-gravity approach (CGA) or a symmetry filter. Curve-fitting procedures were used to reject false-positive marker detections and to calculate intermarker distances. The calibration factor was calculated from the true marker distance and the average of the measured distances in pixels. Results were compared statistically with a grid calibration method, which was taken as the gold standard. A simulation study was performed to assess the influence of image noise on the CGA method. RESULTS: The iterative CGA method was convergent and faster than the symmetry-based technique. For four II sizes (17, 20, 25, and 31 cm), the results from the CGA method were not significantly different from the results obtained with grid calibration. For the II size of 38 cm, a significant difference (0.3% of the grid calibration factor) was found; however, this was caused by the quantification error in the image data and was not clinically relevant. In general, the performance of the CGA method improved with increasing signal-to-noise ratio. CONCLUSIONS: A practical new calibration method for small catheter sizes was developed and validated for quantitative vascular arteriography.

Algorithms↗

Lack of sphygmomanometer calibration causes over- and under-detection of hypertension: a computer simulation study.

OBJECTIVE: To estimate the contribution of inadequate sphygmomanometer calibration to over- and under-detection of hypertension. DESIGN: Monte Carlo simulation of the measurement of blood pressure (BP) of a population with calibrated and uncalibrated sphygmomanometers. Simulated BP measurements included systematic sphygmomanometer error and random variability. MAIN OUTCOME MEASURES: The percentage of hypertensive adults (BP > 140/90 mmHg) not detected and the percentage of adults incorrectly classified hypertensive due to sphygmomanometer error. The percentage of the false positives and false negatives attributable to sphygmomanometer error. The number of additional visits patients need to make to obtain the same improvement in hypertension detection as is obtained by sphygmomanometer calibration. RESULTS: After three visits, uncalibrated sphygmomanometer error causes 20 and 28% of all undetected adult systolic and diastolic hypertension, respectively, and 15 and 31% of all falsely detected adult systolic and diastolic hypertension. In some groups, under-detection is worse; for example, sphygmomanometer error causes 27% of all missed systolic hypertension in 35-44-year-old females. In some age groups, over-detection is worse; for example, after three visits, sphygmomanometer error causes 63 and 50% of falsely detected systolic and diastolic hypertension in 18-24-year-old females, respectively. In-service sphygmomanometer calibration achieves the same or greater improvement in hypertension detection as an additional two visits. CONCLUSIONS: Uncalibrated sphygmomanometers are a preventable cause of clinically significant over- and under-detection of hypertension. Sphygmomanometers should be calibrated regularly by accredited organizations or technicians. Standards and guidelines governing sphygmomanometers in service should be revised. Sphygmomanometer calibration is a cost-effective way of improving hypertension detection.

Adolescent↗

Novel pachometry calibration.

PURPOSE: The purpose of this study was to develop a simple method for cross-calibrating instruments that measure corneal thickness. METHODS: Fourteen rigid lenses of different thicknesses were manufactured using a material with refractive index of 1.376. Center thickness of the lenses (CT) was measured using a computerized optical pachometer (OP), two optical coherence tomographers (OCTs), and a confocal microscope (CM). Accuracy of measurements was compared between the four instruments. RESULTS: Before calibrating the machines, there was a significant effect of the measurement device (p < 0.05). The differences between instruments were eliminated (p > 0.05) after applying calibration equations for each device. In addition, after each instrument was calibrated with lenses of 1.376 refractive index, there was no significant difference (p > 0.05) between measured values of lens center thickness by OP, each OCT, CM, and the physical center thickness of the lenses. CONCLUSIONS: Using calibration lenses with the same refractive index as the cornea (1.376) allows rapid and simple calibration of the pachometers so that corneal thickness measurements from different devices can be used interchangeably.

Calibration↗

Implementation, calibration and accuracy testing of an image-enhanced endoscopy system.

This paper presents a new method for image-guided surgery called image-enhanced endoscopy. Registered real and virtual endoscopic images (perspective volume renderings generated from the same view as the endoscope camera using a preoperative image) are displayed simultaneously; when combined with the ability to vary tissue transparency in the virtual images, this provides surgeons with the ability to see beyond visible surfaces and, thus, provides additional exposure during surgery. A mount with four photoreflective spheres is rigidly attached to the endoscope and its position and orientation is tracked using an optical position sensor. Generation of virtual images that are accurately registered to the real endoscopic images requires calibration of the tracked endoscope. The calibration process determines intrinsic parameters (that represent the projection of three-dimensional points onto the two-dimensional endoscope camera imaging plane) and extrinsic parameters (that represent the transformation from the coordinate system of the tracker mount attached to the endoscope to the coordinate system of the endoscope camera), and determines radial lens distortion. The calibration routine is fast, automatic, accurate and reliable, and is insensitive to rotational orientation of the endoscope. The routine automatically detects, localizes, and identifies dots in a video image snapshot of the calibration target grid and determines the calibration parameters from the sets of known physical coordinates and localized image coordinates of the target grid dots. Using nonlinear lens-distortion correction, which can be performed at real-time rates (30 frames per second), the mean projection error is less than 0.5 mm at distances up to 25 mm from the endoscope tip, and less than 1.0 mm up to 45 mm. Experimental measurements and point-based registration error theory show that the tracking error is about 0.5-0.7 mm at the tip of the endoscope and less than 0.9 mm for all points in the field of view of the endoscope camera at a distance of up to 65 mm from the tip. It is probable that much of the projection error is due to endoscope tracking error rather than calibration error. Two examples of clinical applications are presented to illustrate the usefulness of image-enhanced endoscopy. This method is a useful addition to conventional image-guidance systems, which generally show only the position of the tip (and sometimes the orientation) of a surgical instrument or probe on reformatted image slices.

Adolescent↗

Calibration of transmission electron microscopic mass determination using objects with known mass distribution.

An improved calibration procedure is described for dry mass determination methods, that are based on microdensitometry of transmission electron micrographs. Polystyrene latex spheres, that are supposed to have a homogeneous mass distribution, are used for the calibration procedure. By computer fitting of the theoretically expected mass distribution to the distribution measured in a line through the centre of a sphere, a mass calibration factor is obtained. The number of measurements required for a predetermined calibration accuracy can be decreased considerably as compared to other calibration methods. Accurate calibration and reproducible adjustment of the electron optical magnification are required.

Calibration↗

Approaches for optimizing the calibration standard of Tewameter TM 300.

Calibration of devices measuring transepidermal water loss (TEWL) is in intensive discussion. Comparative studies revealed that comparable measuring systems, e.g. open and closed chamber systems, do not always deliver the same results, even when expressing the measured values in SI units, namely in g/m(2)/h. Therefore, adequate and reliable calibration procedures need to be established. We were able to test the reliability of a multi-step calibration algorithm for an open chamber system such as Tewameter TM 300. In order to achieve reliable measurements, the maintenance of stable microclimate conditions without air turbulences is mandatory. The TEWL values should be compared with those determined gravimetrically on heated skin simulators. The reproducibility of the results is warranted by consecutive measurements on different adjacent spots of a defined area. Preheating of the probe sensors is an effective approach for shortening the measuring time and gaining a rapid steady-state. The accurate calibration of the probe can be checked under laboratory conditions any time. The critical point of the calibration and ultimately the accuracy of in vivo measurements maintain the steady functional capacity of the probes during the entire duration of continuous studies. The studied calibration procedure ensures these requirements.

Air↗

Calibration of new high dose rate 192Ir sources.

The increased popularity of high dose rate (HDR) brachytherapy in the treatment of neoplastic disease has resulted in the introduction of new or redesigned 192Ir sources by various manufacturers. In order to provide accurate clinical dosimetry, accurate calibration of these sources is required. In this work, two new sources are calibrated with the standard, NIST traceable, in-air calibration technique. These sources are the Varian VariSource (VS2000) and the newly redesigned Nucletron MicroSelectron source. An uncertainty budget was performed to determine the overall uncertainty of the measurement, and a total relative expanded uncertainty (k = 2) of 2.15% was calculated. The results of the source calibration using the in-air technique and that obtained based upon the 1991 standard calibration all lie well within this uncertainty. In addition to the in-air calibration, contact autoradiographs of the sources were made with International Specialty Products model HD810 radiochromic film to demonstrate the sources relative dose distributions.

Air↗

Rapid radiographic film calibration for IMRT verification using automated MLC fields.

A method for measuring a film sensitometric curve using a single sheet of film exposed with a two field step-and-shoot MLC treatment was developed and tested with Kodak XV2 and EDR2 films. With this technique a film sensitometric curve can be completed in only 10 minutes, making it practical to generate new film calibrations daily. This method is applicable to film calibrations for all purposes, but is particularly useful in IMRT treatment verification due to the method's use of small fields. This method agrees with the traditional large-field multifilm calibration within 0.5% and will produce sensitometric curves with errors less than 1% throughout the dose range, including uncertainties in dose delivery, film response, and optical density measurements. OD values for XV2 and EDR2 films were consistent in the middle of exposure areas at high depths, but the XV2 film penumbra regions showed large amounts of over-response as the calibration depth increased. If XV2 film is used for IMRT treatment verification, it is necessary to reduce the fluence of low energy photons in areas around the film by using thin lead shields. EDR2 film was shown to have minimal energy dependence, as it accurately represented penumbra areas and yielded identical sensitometric curves generated with 6 and 18 MV photons. However, its darker tint may make it more sensitive to scanning laser film digitizers' horizontal nonuniformities. This single film method proved to be superior to the traditional calibration method and allows fast daily calibrations of films for highly accurate IMRT delivery verifications.

Calibration↗

Fast radiographic film calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification.

Film dosimetry offers an advantageous in-phantom planar dose verification tool in terms of spatial resolution and ease of handling for quality assurance (QA) of intensity modulated radiation therapy (IMRT) plans. A critical step in the success of such a technique is that the film calibration be appropriately conducted. This paper presents a fast and efficient film calibration method for a helical tomotherapy unit using a single sheet of film. Considering the unique un-flattened cone shaped profile from a helical tomotherapy beam, a custom leaf control file (sinogram) was created, to produce a valley shaped intensity pattern. There are eleven intensity steps in the valley pattern, representing varying dose values from 38 to 265 cGy. This dose range covers the most commonly prescribed doses in fractionated IMRT treatments. An ion chamber in a solid water phantom was used to measure the dose in each of the eleven steps. For daily film calibration the whole procedure, including film exposure, processing, digitization and analysis, can be completed within 15 min, making it practical to use this technique routinely. This method is applicable to film calibration on a helical tomotherapy unit and is particularly useful in IMRT planar dose verification due to its efficiency and reproducibility. In this work, we characterized the dose response of the KODAK EDR2 ready-pack film which was used to develop the step valley dose maps and the IMRT QA planar doses. A comparison between the step valley technique and multifilm based calibration showed that both calibration methods agreed with less than 0.4% deviation in the clinically useful dose ranges.

Calibration↗

In situ calibration of fura-2 and BCECF fluorescence in adult rat ventricular myocytes.

Quantitation of Ca+ and H+ activities within cells using presently available fluorescent probes is optimal when the fluorescence signal is calibrated in situ after each experiment. Fura-2 and 2',7'-bis(2-carboxy-ethyl)-5,6-carboxyfluoroscein (BCECF) are difficult to calibrate in freshly dissociated adult cardiac myocytes because calibration procedures produce cellular hypercontracture. In situ calibration was accomplished in rat ventricular cells by saturating fura-2 with La3+, an agent known to produce myocardial relaxation. Since fura-2 has different spectral properties when complexed with La3+ than with Ca2+, scaling factors were defined in vitro and then verified by experiments in cultured neonatal myocytes. In adult rat myocytes using the La3+ method, intracellular Ca2+ concentration ([Ca2+]i) was 131 +/- 47 nM (n = 14) in quiescent cells; diastolic [Ca2+]i and systolic [Ca2+]i in myocytes stimulated at 1 Hz were 140 +/- 56 and 1,088 +/- 211 nM (n = 5), respectively. BCECF fluorescence was calibrated in situ by a method that prevented cellular hypercontracture and reported a pH value of 7.10 +/- 0.10 in cells stimulated at 1.5 Hz. An additional advantage of both methods is that the buffers employed prevented large changes in the redox state of intracellular pyridine nucleotides, thus preventing a change in cellular autofluorescence during the calibration procedure.

Aging↗

Design and calibration of unicapillary pneumotachographs.

This study presents a method for design and calibration of unicapillary pneumotachographs for small-animal experiments. The design, based on Poiseuille's law, defines a set of internal radius and length values that allows for laminar flow, measurable pressure differences, and minimal interference with animal's respiratory mechanics and gas exchange. A third-order polynomial calibration (Pol) of the pressure-flow relationship was employed and compared with linear calibration (Lin). Tests were done for conditions of ambient pressure (Pam) and positive pressure (Ppos) ventilation at different flow ranges. A physical model designed to match normal and low compliance in rats was used. At normal compliance, Pol provided lower errors than Lin for mixed (1-12 ml/s), mean (4-10 ml/s), and high (8-12 ml/s) flow rate calibrations for both Pam and Ppos inspiratory tests (P < 0.001 for all conditions) and expiratory tests (P < 0.001 for all conditions). At low compliance, they differed significantly with 8.6 +/- 4.1% underestimation when Lin at Pam was used in Ppos tests. Ppos calibration, preferably in combination with Pol, should be used in this case to minimize errors (Pol = 0.8 +/- 0.5%, Lin = 6.5 +/- 4.0%, P < 0.0005). Nonlinear calibration may be useful for improvement of flow and volume measurements in small animals during both Pam and Ppos ventilation.

Animals↗

Local INR calibration of the Owren type prothrombin assay greatly improves the intra- and interlaboratory variation. A three-year follow-up from the Swedish national external quality assessment scheme.

In 1999, a simplified procedure for calibration of the Owren prothrombin time (Owren PT) assay was introduced by a working group of the organisation for national quality assurance in laboratory medicine in Sweden. The new protocol allowed local calibration by means of only two lyophilised national plasma calibrators and expression of results as an international normalized ratio (INR). This is our report of a three-year follow-up involving the analysis of data from all laboratories, in hospitals (n=88 in 2002) and primary health care units (n=246 in 2002) that perform the Owren PT assay in Sweden. The interlaboratory variation was significantly improved after the introduction of the new calibration procedure. For the larger hospital-based laboratories, the mean coefficient of variation (CV) was reduced from 7.9% to 5.2% (p<0.0001) when analysing test materials with INR range 2-4. In the higher INR range (>4), the CV was reduced even further, from 10.4% to 6.8% (p<0.0001). The corresponding results from smaller laboratories in the primary health care units showed a similar decrease in CV from 8.2% to 5.7% in the INR range 2-4 (p<0.0001). At the INR range >4, the CV was reduced from 9.5% to 7.8%. The intralaboratory variation was also improved for both types of laboratory categories. This study shows an improved precision, with CV less than 6% at the therapeutic INR range, for both hospital-based laboratories and smaller laboratories in the primary health care system. The results indicate that the Owren PT assay is well suited for local INR calibration employing only two calibrant plasmas in a simplified procedure.

Calibration↗

Validation of respiratory inductive plethysmography using different calibration procedures.

We devised a new calibration procedure [least squares method (LSQ)] for respiratory inductive plethysmography (RIP) and compared it with our previously reported simultaneous equation method (SEQ) of analyzing data in 2 body positions and with the method of Stagg and associates using the analysis of individual breaths in a single body position. The values from RIP were compared with simultaneous spirometry (SP) in 20 normal subjects placed in the standing (STD), supine (SUP), sitting, prone, semi-recumbent, right lateral decubitus, and left lateral decubitus postures. The LSQ gave the most accurate results followed closely by SEQ. In addition, LSQ was compared with the isovolume angle maneuver (ISV) calibration procedure in supine (ISV-SUP) and standing (ISV-STD) postures. Each of the 10 normal subjects breathed at tidal volumes of 250, 750, and 1,250 ml in the SUP and STD postures. Of the values obtained by the LSQ method, 93% were within +/- 10% of SP in SUP and STD positions. Without a change in the posture in which the calibration was made, 83% of values with ISV-SUP and 90% of values with ISV-STD were within +/- 10% of SP. When body position was changed, 65% of the values obtained with ISV-SUP and 38% of the values obtained with ISV-STD were within +/- 10% of SP. With the LSQ, 45% of isovolume angles in SUP and STD position were within 45 +/- 3 degrees; 40% of isovolume angles with ISV-SUP and 60% with ISV-STD were within 45 +/- 3 degrees when body position was changed from position calibrated. In estimating fractional contribution of rib cage and abdominal compartments. LSQ was comparable to ISV in the standing posture but generally gave lesser values for the rib cage contribution in the supine posture than ISV. The optimal calibration procedure for respiratory inductive plethysmography in terms of accuracy and ease of subject performance is the least squares calibration procedure.

Calibration↗

Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.

We investigated the accuracy of a computer-assisted, respiratory inductive plethysmograph (Respicomp) on 50 awake human newborns who were lying supine. Breaths were selected with different rib cage (RC) to pneumotach (PNT) and abdomen (AB) to pneumotach (PNT) values. The equation RC/PNT + AB/PNT = 1 was solved using the least squares method (LSQ) of calculation of calibration factors. Validation of the calibration factors was performed with a range of consecutive breaths between 6 and 22. Of the 1,128 validation or revalidation breaths, 628 (56%) were within 10% of the simultaneously measured PNT volume, 1,024 (91%) were within 20%, and 1,128 (100%) were within 30%. The RC or AB compartment contributions to ventilation changed spontaneously in the awake newborns. This change eliminated the need to wait for varying sleep states to obtain calibration factors and reduced total time required for calibration. (Some loss of accuracy is a compromise with this method; the calibration factors obtained do not remain accurate while the infant is asleep.) This method provided a reliable and rapid calibration and validation technique of the respiratory inductive plethysmograph (Respicomp) on awake newborns.

Abdomen↗

Comparison of a flexible laryngoscope with calibrated sizing function to intraoperative measurements.

OBJECTIVES: The objectives were to assess the clinical performance and accuracy of a prototype fiberoptic transnasal laryngeal endoscope with an auxiliary optical system that allows images to be spatially calibrated. METHODS: A novel fiberoptic endoscope was developed that projects green laser beams across the field of view from a separate optical channel. According to the location of the spots in the field of view, the images can be calibrated with a software routine. To assess its performance, we compared measurements of 14 lesions imaged with the calibrated endoscope and during microlaryngoscopy, where a calibration instrument was placed next to the lesions. Four clinicians measured lesion length, width, and area from the collected images. RESULTS: The calibrated endoscope performed as well as current flexible fiberoptic laryngoscopes in terms of image quality and patient comfort. For lesions with well-defined borders, the error ranged from 14% to 23% for length, from 20% to 30% for width, and from 33% to 50% for area across observers. Factors contributing to larger errors in some subjects were identified. CONCLUSIONS: The calibrated endoscope is capable of providing useful sizing information for laryngeal structures, and these measures correspond quite well to more direct measurements in the operating room. Objective sizing of laryngeal lesions is complicated by subjective judgments of lesion boundaries, which can be indistinct in many cases.

Adult↗

Research diagnostic criteria for temporomandibular disorders: a calibration and reliability study.

The aim of this study was to investigate the reliability between different examiners when using the axis I of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). The hypothesis was that the standardized RDC/TMD examination protocol enables calibrated examiners to evaluate all examination items reliably. After calibration training by the RDC/TMD calibration team including the calibration of palpation pressure and the performance of the standardized examination protocol, four examiners, blinded to the patients' medical histories examined 24 subjects in a randomized sequence. One experienced examiner was the standard (hierarchical calibration). The recorded measurements strictly followed the RDC/TMD. Intraclass correlation coefficients (ICC), bias and precision were calculated to estimate interrater reliability. Acceptable (0.75 > or = CC > 0.4) to excellent (ICC > 0.75) reliability was found for 20 of the 23 (87%) examinations. Only sub-retromandibular muscle palpation and joint sound vibration recordings on lateral excursion showed poor-results (ICC < or = 0.4). The RDC/TMD examination protocol enables calibrated examiners to perform most (87%) examination items with satisfactory reliability. Therefore multi-site studies based on the RDC/TMD examination protocol may become feasible, keeping in mind the unsatisfactory reliability of 13% of the items (clicking during laterotrusion to the ipsilateral side, palpation of the posterior and submandibular region).

Adolescent↗

Microarray scanner calibration curves: characteristics and implications.

BACKGROUND: Microarray-based measurement of mRNA abundance assumes a linear relationship between the fluorescence intensity and the dye concentration. In reality, however, the calibration curve can be nonlinear. RESULTS: By scanning a microarray scanner calibration slide containing known concentrations of fluorescent dyes under 18 PMT gains, we were able to evaluate the differences in calibration characteristics of Cy5 and Cy3. First, the calibration curve for the same dye under the same PMT gain is nonlinear at both the high and low intensity ends. Second, the degree of nonlinearity of the calibration curve depends on the PMT gain. Third, the two PMTs (for Cy5 and Cy3) behave differently even under the same gain. Fourth, the background intensity for the Cy3 channel is higher than that for the Cy5 channel. The impact of such characteristics on the accuracy and reproducibility of measured mRNA abundance and the calculated ratios was demonstrated. Combined with simulation results, we provided explanations to the existence of ratio underestimation, intensity-dependence of ratio bias, and anti-correlation of ratios in dye-swap replicates. We further demonstrated that although Lowess normalization effectively eliminates the intensity-dependence of ratio bias, the systematic deviation from true ratios largely remained. A method of calculating ratios based on concentrations estimated from the calibration curves was proposed for correcting ratio bias. CONCLUSION: It is preferable to scan microarray slides at fixed, optimal gain settings under which the linearity between concentration and intensity is maximized. Although normalization methods improve reproducibility of microarray measurements, they appear less effective in improving accuracy.

Calibration↗