PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DUCTUS ARTERIOSUS. PATENT”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Simultaneous double or triple coil technique for closure of moderate sized (> or = 3.0 mm) patent ductus arteriosus.

One important complication of coil occlusion of patent ductus arteriosus using the conventional Gianturco coil is migration of coils into peripheral vessels. Especially in patients having relatively larger size ductus, the risk for such complication could be increased. In this regard, a detachable coil may have some technical benefits in performing coil occlusion and reducing the incidence of complications such as migration of coil. Based on our clinical experiences, we describe the clinical efficacy of a simultaneous double or triple coil occlusion technique using the Cook detachable coil system to close the ductus arteriosus, especially in patients whose ductus diameter more than 3.0 mm.

Adolescent↗

Char syndrome, an inherited disorder with patent ductus arteriosus, maps to chromosome 6p12-p21.

BACKGROUND: Patent ductus arteriosus (PDA) is a relatively common form of congenital heart disease. Although polygenic inheritance has been implicated, no specific gene defects causing PDA have been identified to date. Thus, a positional cloning strategy was undertaken to determine the gene responsible for the Char syndrome, an autosomal dominant disorder characterized by PDA, facial dysmorphism, and hand anomalies. METHODS AND RESULTS: A genome scan was performed with 46 members of 2 unrelated families in which the disease was fully penetrant but the phenotype differed. Significant linkage was achieved with several polymorphic DNA markers mapping to chromosome 6p12-p21 (maximal 2-point LOD score of 8.39 with D6S1638 at theta=0.00). Haplotype analysis identified recombinant events that defined the Char syndrome locus with high probability to a 3. 1-cM region between D6S459/D6S1632/D6S1541 and D6S1024. CONCLUSIONS: A familial syndrome in which PDA is a common feature was mapped to a narrow region of chromosome 6p12-p21. Additional analysis with other families and polymorphic markers as well as evaluation of potential candidate genes should lead to the identification of the Char syndrome gene, which will provide insights into cardiogenesis as well as limb and craniofacial development.

Chromosome Mapping↗

Comparison of the one-and-a-half-year results of closure of patent ductus arteriosus by transcatheter coils placement with surgical ligation.

Patent ductus arteriosus (PDA) is a common type of congenital cardiovascular lesion. It usually needs surgical ligation in a full-term baby after 1 year of age. Transcatheter implantation of coils was introduced for the closure of small- to moderate-sized PDA in 1992. From November 1995 to November 1998, the authors closed the PDA in 153 patients by transcatheter implantation of coils and by surgical ligation in 10 patients. One hundred fourteen of them were studied for more than 1(1/2) years. The regular follow-up studies, including physical examination; electrocardiography; and pulsed, continuous-wave, and color Doppler flow mapping, were performed on day one and day 2, and 1 week, 1 month, 3 months, 6 months, and 1 year after the procedure. The results of the closure of PDA by surgical ligation or coil placement were compared and analyzed in all the patients.

Adolescent↗

Transcatheter closure of the patent ductus arteriosus using an Amplatzer duct occluder in adults.

Patent ductus arteriosus (PDA) is a congenital heart disease that frequently escapes detection until the patient reaches adulthood. Percutaneous closure of the PDA has been established as a safe alternative to surgery, the Amplatzer duct occluder (ADO) is a new device that has been recently reported in paediatric patients. Our initial experience with an of ADO in an adult population appears to be encouraging and as good as in paediatric patients.

Adolescent↗

Snare-assisted transcatheter coil occlusion of patent ductus arteriosus.

Transcatheter occlusion of a small or moderate patent ductus arteriosus (PDA) using Gianturco coils is safe and effective. Several investigators have reported using different techniques with variable results. To eliminate the serious potential complications of inadvertent coil embolization to undesirable sites and to improve control of the coil throughout the procedure, a modified snare-assisted method with approach from the main pulmonary artery was developed. However, articles discussing this technique are still limited. Herein, we report our successful experience of the snare-assisted technique to occlude small or moderate PDAs in three children aged from 1 to 8 years old. We achieved immediate total occlusion in all three cases with no complications. All three patients were discharged the next day and there was no coil dislodgement, left pulmonary stenosis, or residual shunting during the follow-up period of up to 3 years. This technique had the advantages of safety, optimal positioning, and improved stability of coil implantation.

Cardiac Catheterization↗

Clinical profile and management of symptomatic patent ductus arteriosus in premature infants.

Twenty cases of symptomatic patent ductus arteriosus (PDA) in preterm inborn infants were studied retrospectively. The diagnostic criteria were a systolic or a systolodiastolic murmur, tachycardia (greater than 160 per minute), hyperdynamic precordium, collapsing arterial pulses, cardiomegaly or a need for intermittent positive pressure ventilation or continuous distending airway pressure. The incidence was found to be 2.48/1000 live births and 1.5% of SCBU admission. All babies were less than 35 weeks gestation and 18/20 weighed less than 1750 g at birth. Ten babies were treated with indomethacin (0.2 mg/kg) and two of these babies died before the course of treatment was completed. Ten babies were treated with conservative therapy. They could not be administered indomethacin because two died of fulminant sepsis soon after the diagnosis was made; two babies had sepsis and DIC but recovered from it, three had thrombocytopenia, one had azotemia, two babies had hyperbilirubinemia requiring exchange transfusion. The two groups of babies matched in respect to gestational age, sex, age at presentation, birth weight and associated illnesses. Two babies in each group died soon after diagnosis. Of the eight babies in each group, six babies closed the ductus on indomethacin therapy as against two on conservative therapy. This difference was significant (p less than 0.05). The babies who responded to indomethacin were all treated within two weeks of age. None of them showed any complication of drug therapy or recurrence of PDA. We conclude that intragastric indomethacin given early in the management of symptomatic PDA in term infants is a safe and effective modality.

Ductus Arteriosus, Patent↗

[The transcatheter closure of patent ductus arteriosus. The initial experience].

Percutaneous closure of the patent ductus arteriosus (PDA) has been recently reported to be an effective alternative in the treatment of patients with ductal shunting. We report the initial experience and results during follow-up of percutaneous ductal occlusion with the Rashkind occluder (USCI) in six patients with isolated PDA. Ages ranged from 3 to 23 years. Diagnosis was corroborated with two dimensional and Doppler echocardiography in all patients. During cardiac catheterization systolic pulmonary artery pressure oscillated between 22 and 64 mmHg and Qp/Qs ratio between 1.3 and 4.1. In two patients prosthesis of 12 mm were used and in the remaining prosthesis of 17 mm. Only one patient demonstrated total occlusion during immediate control aortography, the other patients presented central residual shunting over the occluder. In the three patients occlusion with balloon-catheter was added to the procedure, resulting in total occlusion in two and significant reduction of the shunt magnitude in one. Two technical problems were resolved satisfactorily. None of the cases presented device embolization. Mean follow-up was 23.8 months with control echocardiograms at 24 hours, 1, 4, 12 and 24 months. In all patients immediate reduction of the left atrial dimension was demonstrated. Three patients presented residual shunts in the first 24 hours. In two of them total occlusion had occurred after one month and the other patient persisted with a small residual shunt until one year after the procedure. In conclusion, in this small study group good results were obtained with percutaneous ductal closure.

Adult↗

Doppler ultrasonic flow detection as an adjunct in the diagnosis of patent ductus arteriosus in premature infants.

Since ligation of a patent ductus arteriosus in the neonate with idiopathic respiratory distress syndrome seems to improve the clinical condition of the infant, we have attempted to identify those neonates earlier with the noninvasive Doppler ultrasonic technique, recording brachial arterial flow signals. Sixteen patients were studied. In the 5 with reversed brachial flow who were operated upon, ligation of a PDA resulted in improvement and postoperative correction of brachial flow reversal as evidenced by the Doppler ultrasonic technique.

Doppler Effect↗

[Transfemoral vein catheter occlusion of patent ductus arteriosus].

Between February 1988 and September 1989, 15 patients underwent closure of patent ductus arteriosus by the Rashkind technique modified by Mullins. The insertion of the occluder was achieved in all cases; however, in one patient, the prosthesis migrated to the abdominal aorta several hours after implantation. No other complications were observed. All patients were discharged from hospital under 24 hours after the procedure. The follow-up period ranges from 3 to 12 months. The rate of complete closure of the ductus was 50% 24 hours after implantation, 57% at 3 months, 66% at 6 months and 82% 12 months after the procedure. Our results suggest that the Rashkind technique for the closure of patent ductus arteriosus by the transvenous femoral approach is an effective and low risk procedure.

Adolescent↗

Summary and Comparison of Patent Ductus Arteriosus Closure Devices.

A number of patent ductus arteriosus (PDA) occluding devices have been studied in an attempt to develop a transcatheter method of closure of PDA. Some devices were tested in only animal models, whereas others progressed to clinical trials in human subjects. Some devices have been discontinued, some received approval for general clinical use, and many have not yet received approval by regulatory authorities. No prospective randomized clinical trials have been undertaken and, therefore, data on separate clinical trials are used to determine relative efficacy of the devices. Selection of a method of PDA closure depends largely on its minimal diameter and to some degree on its shape. Silent PDAs do not need occlusion. Very small to small PDAs may be occluded by free or detachable Gianturco coils (Cook Cardiology, Bloomington, IN). Moderate-to-large PDAs require closure by devices, conventional surgery, and videothoracoscopic interruption. The choice in the latter group depends largely on the availability of a given method at a given institution at that particular time. Approval of several of the devices by regulatory authorities may result in conduct of prospective randomized clinical trials and use of a device or method most appropriate to the size and shape of the PDA.

Journal Article↗

[Diagnosis and surgical treatment of 102 cases of ventricular septal defect with patent ductus arteriosus].

OBJECTIVE: To summarize the experience of diagnosis and surgical treatment of ventricular septal defect with patent ductus arteriosus. METHODS: We retrospectively analyzed the clinical data of 102 cases of ventricular septal defect combined with patent ductus arteriosus who underwent surgical treatment. Preoperative ultrasonic cardiogram (UCG) showed ventricular septal defect combined with patent ductus arteriosus in 82 cases and ventricular septal defect in 20 cases. RESULTS: The hospital mortality was 4.9% (5/102). The reasons for death included low cardiac output syndrome (1 case), pulmonary hypertension crisis (2 cases) and respiratory failure (2 cases). In the remaining patients,the perioperative complications included lung infection (7 cases), pulmonary atelectasis (5 cases), hydrothorax (1 case), and pulmonary hypertension crisis (2 cases); and all the 15 patients recovered lastly. The pulmonary hypertension of all living patients decreased to some degree. The therapeutical effectiveness was satisfactory. CONCLUSION: Ventricular septal defect with patent ductus arteriosus is easy to be confused with ventricular septal defect clinically. At the same time,it is diffcult to form a correct diagnosis in some patients by UCG preoperatively. To prevent the occurrence of perfusive lung, it is important to reinforce preoperative diagnosis and exploration during operation. Because pulmonary hypertension in patients with ventricular septal defect with patent ductus arteriosus emerges early and develops quickly, it tends to result in organic pulmonary hypertension which can make patients lose operation chances and influence the long-term therapeutical effect. Surgical operation should be performed as soon as possible. Optimal operative timing and proper perioperative management play important roles in surgical results.

Abnormalities, Multiple↗

Management of patent ductus arteriosus in preterm babies.

There is a higher incidence of delayed closure of the patent ductus arteriosus in premature babies with respiratory distress syndrome. From July, 1975, to December, 1977, 57 small, preterm infants with patent ductus arteriosus were diagnosed at our neonatal intensive care unit. From July, 1975, until September, 1976 (first period), 23 patients were diagnosed, and 11 underwent surgical ligation of a patent ductus arteriosus. There were 3 early deaths. From October, 1976, until December, 1977, out of a total of 34 patients with diagnosed patent ductus, 18 were treated with indomethacin, and only 3 required ligation. Our present policy for patent ductus arteriosus with respiratory distress syndrome in the premature baby is to initiate early treatment with indomethacin. If this treatment fails and the infant's status deteriorates, we perform early surgical ligation of the ductus in order to minimize the time on mechanical ventilation and lessen the chances of the development of bronchopulmonary dysplasia.

Ductus Arteriosus↗

Aortic stent-graft for patent ductus arteriosus in adults: the aortic exclusion technique.

The risk of closure of a patent ductus arteriosus in the elderly is high because of the fragility of the aorta and aneurysmal change in the ductus. Stent-grafting has emerged as a method of treatment of pathology of the aorta. We describe a case where this new endovascular technique has been successfully applied for closure of a patent ductus arteriosus in a high-risk patient. It may become part of the armamentarium for this pathology in adults.

Aged↗