PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Fixed”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling.

Hertzian cone cracks visible at the loading site of 20 all-ceramic fixed partial dentures (FPDs), tested in vitro, led to the hypotheses that failure was due to the propagation of localized contact damage crack systems (Hertzian stress state) and that such damage was an unlikely clinical failure mode. Fractographic analysis of the 20 laboratory-failed and nine clinically-failed all-ceramic FPDs allowed for definitive testing of these hypotheses and a comparison between in vitro and in vivo failure behavior. In all cases, failure occurred in the FPD connectors (none from contact damage), with approximately 70 to 78% originating from the interface between the core and veneer ceramics. The coincidence between failure origins provides strong evidence that the in vitro test modeled aspects of structural behavior having clinical importance. The fractographic observations, coupled with the in vitro failure load data, furnished very specific boundary conditions which were applied to constrain mathematical models of FPD connector failure. Finite element analysis (FEA) of the laboratory FPDs found that maximum principal tensile stresses would occur at locations consistent with the fractographic observations only if: (1) there were appropriate elastic moduli differences between the ceramics; and (2) a small amount of abutment rotation was allowed. Weibull failure probability (Pf) calculations, incorporating FEA stress profiles, very closely replicated the laboratory failure distribution only when: (1) the veneer ceramic was much weaker than the core ceramic; and (2) the Weibull modulus of the core-veneer interface was much lower than that for the free veneer surface (i.e., the interface is of lower quality with regard to defects).(ABSTRACT TRUNCATED AT 250 WORDS)

Ceramics↗

Resin-bonded fixed partial dentures: ten-year follow-up.

PURPOSE: The aim of the study was to evaluate the survival rate of resin-bonded fixed partial dentures delivered between 1993 and 2003 in the Department of Prosthodontics of the University of Turin and in several private practices. MATERIALS AND METHODS: The analysis took into consideration the following variables: preparations, metallic alloys, metal preparation and conditioning of the inner surfaces, isolation during cementation, type of cement, kind of prostheses, number of abutments, and number of missing teeth included in the prostheses. RESULTS: The estimated survival probability for the first debonding or failure was 85% after 5 years and 71% after 10 years. CONCLUSIONS: The use of dental dam during cementation reduced the risk of debonding. No differences in survival rate were found for the other parameters.

Cementation↗

Clinical long-term results of VITA In-Ceram Classic crowns and fixed partial dentures: A systematic literature review.

PURPOSE: VITA In-Ceram Classic is a system designed to fabricate all-ceramic crowns and fixed partial dentures (FPDs) with a glass-infiltrated aluminum oxide core material. This systematic literature review gives an overview of the clinical performance of the VITA In-Ceram Classic Alumina, Spinell, and Zirconia restorations. MATERIALS AND METHODS: Based on a systematic literature review, an evidence-based selection and assessment of clinical studies of VITA In-Ceram Classic ceramics was carried out. RESULTS: A total of 299 publications were found, 21 of which met the inclusion criteria. Only a few meaningful studies of In-Ceram Alumina FPDs and In-Ceram Zirconia crowns and FPDs were found. The 5-year survival rate of In-Ceram Alumina crowns and In-Ceram Spinell crowns ranged from 91.7% to 100% and is similar to the survival rate of conventional metal-ceramic crowns. The 5-year survival rate of single-retainer In-Ceram Alumina resin-bonded FPDs (RBFPDs) was 92.3%, which is higher than that of 2-retainer RBFPDs. CONCLUSION: In-Ceram Classic Alumina can be recommended for anterior and posterior crowns as well as for anterior single-retainer RBFPDs. Further studies should be initiated to evaluate in detail the clinical performance of In-Ceram Classic Alumina FPDs. In-Ceram Classic Spinell can be recommended for anterior crowns, especially if highly esthetic results are requested. For In-Ceram Classic Zirconia crowns or FPDs no statement can be made presently because of insufficient data.

Aluminum Oxide↗

Finite element analysis of fixed partial denture replacement.

The purpose of this study was to investigate, by means of the finite element method the mechanical behaviour of three designs of fixed partial denture (FPD) for the replacement of the maxillary first premolar in shortened dental arch therapy. Two-dimensional, linear, static finite element analyses were carried out to investigate the biomechanics of the FPDs and their supporting structures under different scenarios of occlusal loading. Displacement and stress distribution for each design of FPD were examined, with particular attention being paid to the stress variations along the retainer-abutment--and the periodontal ligament-bone interfaces. The results indicated that displacement and maximum principal stresses in the fixed-fixed, three-unit FPD were substantially less than those in the two-unit cantilever FPDs. Of the two cantilever FPDs investigated, the distal cantilever design was found to suffer less displacement and stresses than the mesial cantilever design under similar conditions of loading. The highest values for maximum principal stress in the cantilever FPDs were found within the connector between the pontic and the retainer, and within the periodontal ligament and adjacent bone on the aspect of the retainer away from the pontic.

Bicuspid↗

Flexural properties of the bulk fiber-reinforced composite DC-tell used in fixed partial dentures.

PURPOSE: The aim of this study was to measure the flexural properties of fiber-reinforced composite (FRC) used in frameworks of fixed partial dentures. In addition, the influence of water storage on the properties was determined. MATERIALS AND METHODS: Rhombic test specimens for four groups were milled from bulk FRC material DC-Tell. The test specimens of the first group were stored and tested dry. In the second group, the test specimens were water stored for 3 months at 37 +/- 1 degrees C and tested in water. The specimens of the third group were also water stored, but they were tested dry at room temperature. Water-stored test specimens of the fourth group were dehydrated and tested dry at room temperature. A three-point bending test was used to measure the flexural properties. The quantity of glass fibers in the test specimens was determined by combustion analysis. Water uptake was calculated after 3 months of water immersion. The direction and length of fibers were examined, and elemental composition was determined. RESULTS: Water storage decreased the flexural strength by 66% and flexural modulus by 60%. After dehydration, the flexural strength did not recover to the same level as the flexural strength of the dry-group specimens. The fiber content was 38% by volume. Water uptake was 3 wt%. The reinforcement of DC-Tell was short fibers in random orientation, and the elemental composition of fibers was similar to that of E-glass. CONCLUSION: Water storage decreases the flexural properties of the bulk fiber-reinforced composite DC-Tell. This may restrict the use of DC-Tell as a framework of crowns and bridges in the oral cavity in the long term.

Analysis of Variance↗

A preliminary prospective evaluation of all-ceramic crown-retained and inlay-retained fixed partial dentures.

PURPOSE: The purpose of this preliminary prospective study was to evaluate the clinical outcome of crown-retained and inlay-retained fixed partial dentures (FPDs) made from a new lithium-disilicate glass-ceramic (IPS e.max Press, Ivoclar Vivadent). MATERIALS AND METHODS: Eighty-one 3-unit FPDs were placed in 68 patients. The FPDs replaced teeth in the anterior (8%) and posterior region (92%). All teeth were prepared according to a standardized protocol. The size of the proximal connector of the FPDs was 12 mm2 (anterior) or 16 mm2 (posterior), respectively. Crown-retained FPDs were cemented either with glass ionomer (n = 20) or resin composite (n = 16), while all inlay-retained FPDs (n = 45) were cemented with resin composite. Initial follow-up was performed at 6 and 12 months and annually thereafter. RESULTS: The mean observation periods were 48 months (for crown-retained FPDs) and 37 months (for inlay-retained FPDs). None of the crown-retained FPDs failed during the observation period, while 6 inlay-retained FPDs (13%) had to be replaced. Six cases failed because of debonding (n = 3) or a combination of debonding and fracture (n = 3). During the observation period, 2 patients died and the status of another 5 patients is unknown. The 4-year survival rate according to Kaplan-Meier was 100% for crown-retained FPDs and 89% for inlay-retained FPDs. The differences between the groups were statistically significant. CONCLUSION: Crown-retained 3-unit FPDs made from a new glass-ceramic have a significantly better outcome up to 5 years than inlay-retained 3-unit FPDs over the observation period.

Adult↗

Longevity of a maxillary 2-unit cantilever fixed partial denture: clinical report.

In this clinical report, we discuss the length of service and subsequent replacement of a maxillary anterior 2-unit cantilever fixed partial denture (FPD). The FPD provided 53 years of service to the patient and was finally replaced with a 2-unit porcelain-fused-to-metal (PFM) FPD. The original prosthesis replaced a missing maxillary lateral incisor using a partial coverage metal retainer, whereas the new FPD was designed with a complete coverage PFM retainer.

Aged↗

Fixation of 5-unit implant-supported fixed partial dentures and resulting bone loading: a finite element assessment based on in vivo strain measurements.

PURPOSE: It is believed that implant-supported fixed partial dentures (FPDs) should display passive fit. The objective of this in vivo-based finite element analysis (FEA) was to quantify the magnitude of bone loading occurring on account of the fixation of cemented or screw-retained 5-unit superstructures. MATERIALS AND METHODS: Based on a patient situation with 3 implants, 4 different groups of restorations with 10 samples each were fabricated. Strain gauges on the pontics of the restorations were used for in vivo measurements. Using the values obtained, bone loading in 3-dimensional FE models was simulated as von Mises equivalent stress. RESULTS: The in vivo measured mean strain values ranged from 32 microm/m to 458 microm/m at the different sites. FEA revealed stresses between 5 and 30 MPa in the cortical area, while in trabecular bone values ranging from 2 MPa to 5 MPa were observed. Stress of a similar magnitude was found for axial implant loading with 200 N. DISCUSSION: Assuming that the axial loading of a single implant with 200 N is within the realm of the bone's adaptation ability, it would appear that the amount of stress resulting from the fixation of superstructures alone does not constitute a risk. CONCLUSIONS: The level of precision of fit which can be obtained in superstructure fabrication would appear to suffice to produce restorations that do not cause bone damage.

Bite Force↗

Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain.

Four three-dimensional numerical models of a fixed partial denture were constructed, analyzed, and compared by means of the finite element method. Each model consisted of three elements destined to compensate the loss of a first molar. The second proemolar and the second molar were used as abutments. The connector surface was varied and then tested. A unidirectional axial force was applied to the center of the occlusal surface of the pontic. For each model, we measured the strain undergone by the connectors that link the pontic to each abutment. Results show that the strain measured in the mesio-distal direction was much more significant than in any other direction. Strain originated on either side of the loading point, centrally located on the cervical side of the pontic. The 0.15% strain threshold, beyond which rupture is possible, was only reached in one model (connector surface = 3.3 mm2). Increasing both the height and the width of the connectors by 1 mm resulted in extending the surface by 3.3 to 7.95 mm2. Although the surface increased by 141%, the strain threshold was not reached. This first result indicates that extending the surface of the connectors, which is less consistent with periodontal clinical requirements, is not necessary to ensure resistance to rupture.

Bite Force↗

Two-unit cantilevered resin-bonded fixed partial dentures--a retrospective, preliminary clinical investigation.

PURPOSE: The aim of this study was to retrospectively evaluate the clinical retention and abutment movement of 2-unit cantilevered resin-bonded fixed partial dentures (FPD) that were inserted at Prince Philip Dental Hospital in Hong Kong. MATERIALS AND METHODS: Of 45 patients who were identified from a hospital computer search after receiving a 2-unit cantilevered resin-bonded FPD, 31 were clinically examined (33 FPDs). For each patient the following data were recorded: gender, age, cementation date, endodontic treatment if performed, bone support, tooth mobility, and FPD tipping or drifting. Data about any debonds with subsequent treatment and patient satisfaction on a 10-point scale were also recorded. RESULTS: The mean service life for the 33 prostheses was 30 +/- 18 months, with a range of 72 days to 67 months. One prosthesis debonded, resulting in a clinical retention rate of 97%. No rotation, drifting, or tipping was observed for any of the prostheses during the short period of this study. CONCLUSION: Two-unit cantilevered resin-bonded FPDs are successful in the short term, but further research is required to determine if they offer a viable alternative to fixed-fixed resin-bonded FPD designs.

Adolescent↗

Survival and complication rates of combined tooth-implant-supported fixed partial dentures.

OBJECTIVES: The objective of this study has been to review the incidence of biological and technical complications in case of tooth-implant-supported fixed partial denture (FPD) treatments on the basis of survival data regarding clinical cases. MATERIAL AND METHODS: Based on the treatment documentations of a Bundeswehr dental clinic (Cologne-Wahn German Air Force Garrison), the medical charts of 83 patients with tooth-implant-supported FPDs were completely recorded. The median follow-up time was 4.73 (time range: 2.2-8.3) years. In the process, survival curves according to Kaplan and Meier were applied in addition to frequency counts. RESULTS: A total of 84 tooth-implant (83 patients) connected prostheses were followed (132 abutment teeth, 142 implant abutments (Branemark, Straumann). FPDs: the time-dependent illustration reveals that after 5 years, as many as 10% of the tooth-implant-supported FPDs already had to be subjected to a technical modification (renewal (n=2), reintegration (n=4), veneer fracture (n=5), fracture of frame (n=2)). In contrast to non-rigid connection of teeth and implants, technical modification measures were rarely required in case of tooth-implant-supported FPDs with a rigid connection. There was no statistical difference between technical complications and the used implant system. Abutment teeth and implants: during the observation period, none of the functionally loaded implants (n=142) had to be removed. Three of the overall 132 abutment teeth were lost because of periodontal inflammation. The time-dependent illustration reveals, that after 5 years as many as 8% of the abutment teeth already required corresponding therapeutic measures (periodontal treatment (5%), filling therapy (2.5%), endodontic treatment (0.5%)). After as few as 3 years, the connection related complications of implant abutments (abutment or occlusal screw loosening, loss of cementation) already had to be corrected in approximately 8% of the cases. In the utilization period there was no screw or abutment fracture. CONCLUSION: Technical complications of implant-supported FPDs are dependent on the different bridge configurations. When using rigid functional connections, similarly favourable values will be achieved as in case of solely implant-supported FPDs. In this study other characteristics like different fixation systems (screwed vs. cemented) or various implant systems had no significant effect to the rate of technical complications.

Adult↗

Implant-supported, long-span fixed partial denture for a scleroderma patient: a clinical report.

Scleroderma poses many difficulties and challenges for the treating dentist. Until now, dental implant treatment for patients with scleroderma was limited to either complete overdentures or short-span fixed partial dentures. This clinical report describes the use of modified techniques to fabricate a long-span fixed prosthesis delivered after serial extractions and implant placement.

Dental Care for Chronically Ill↗

Dimensions of metal framework components of metal-ceramic fixed partial dentures constructed in a dental school setting.

OBJECTIVES: The aims of this study were to measure the dimensions of connectors and retainer copings of metal-ceramic fixed partial denture (FPD) frameworks and to explore, by means of a questionnaire, the factors viewed by technicians as important in their planning and provision of such dimensions. METHOD AND MATERIALS: Using two calliper devices, measurements were made of 66 consecutive FPDs under production in a dental school-based laboratory. The dimensions of 176 connectors and 124 retainers were analyzed with reference to FPD length and to number of pontics in a span. Questionnaires were completed by all 14 technicians working in the fixed prosthodontics section of the laboratory. RESULTS: The largest mean vertical connector dimensions were in the anterior regions of both arches, while the largest mean horizontal dimensions were in the posterior regions. Dimensions were unrelated to FPD size and length of interabutment span. The minimum thickness of the retainer coping walls was generally below optimal recommendations. Available space was the factor most commonly cited by technicians as dictating the dimensions that they applied. CONCLUSION: Dimensions were generally smaller than current recommendations, which the questionnaire responses indicate are largely due to space constraints.

Attitude of Health Personnel↗

Resin-bonded fixed partial denture technique: results of a medium-term clinical follow-up investigation.

Results of a clinical investigation with cast metal, electrolytically etched, resin-bonded fixed partial dentures (FPDs) are reported. These FPDs were inserted under standardized conditions. The FPDs had been in place and functioning for an average time of 21.4 months. Sixty-five patients with a total of 82 resin-bonded FPDs were followed up. There was a retentive failure in only one FPD. All patients were satisfied from both functional and esthetic points of view. The results of this study indicate that the concept of treatment with resin-bonded FPDs should be considered as an alternative to conventional treatment.

Acid Etching, Dental↗

Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up.

OBJECTIVES: The purpose of this prospective clinical cohort study was to determine the success rate of 3- to 5-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 3 years of function. METHOD AND MATERIALS: Forty-five patients in need of at least 1 FPD to replace 1 to 3 posterior teeth were included. The frameworks were produced by means of a prototype computer-assisted manufacture system. They were milled with a precisely calculated increase in size out of presintered zirconia blanks and subsequently shrunk to the required size. Fifty-seven FPDs were cemented using either Variolink or Panavia TC cement. Clinical and radiographic examinations were performed at baseline, 12, 24, and 36 months after cementation. Statistical analysis was performed by descriptive statistics and the Kaplan-Meier survival analysis. Comparisons of probing depth, Plaque Index, and bleeding on probing between test (abutment) and control (contralateral) teeth were done with the McNemar test. RESULTS: Thirty-six patients with 46 FPDs were available for examination after 36 months. No fractures occurred, rendering a 100% success rate of the zirconia frameworks. Seven FPDs had to be replaced because of biologic and technical problems. The survival rate, therefore, was 84.8%. Secondary caries was found in 10.9% of the FPDs, and chipping of the veneering ceramic was found in 13.0%. There were no significant differences regarding the probing depth in test and control teeth. CONCLUSION: Zirconia frameworks demonstrated sufficient stability for replacement of posterior teeth. However, the high rates of technical problems should be reduced by further developments of the prototype processing technology.

Cementation↗

Resin-bonded fixed partial dentures: a recall study.

A clinical recall program was initiated at the University of Minnesota to evaluate the longevity and factors affecting longevity of resin-bonded fixed partial dentures (FPDs). Of the 49 resin-bonded FPDs evaluated in the clinic, 43 were acid-etched metal, resin-bonded FPDs, four were combinations of resin-bonded and conventional FPDs, and two were composite resin pontics. None of the combination FPDs and one of the two composite resin pontics were judged as failed at the examination. Of the 43 acid-etched metal resin-bonded FPDs, 15 were found to be debonded (failure rate = 34.9%). The average length of service for the 43 FPDs was 47.3 months. The average time of placement to debondment was 33 months for the 15 debonded FPDs. The failure rate for maxillary FPDs and FPDs with two retainers were significantly lower than the failure rate for mandibular FPDs and FPDs with more than two retainers (p greater than 0.05). The clinical significance of the present study was discussed.

Adolescent↗

Discrimination ability in patients with extensive fixed partial dentures on mandibular canine teeth.

To study discrimination ability under different test situations, a psychophysiologic test was performed in a group of patients with 12-unit mandibular fixed partial dentures supported on the 2 canines. The cantilever segments were exchangeable. Analyses of discrimination ability were performed with regard to periodontal and endodontic status of the abutment teeth and to type of mucosal contact in cantilever regions. Discrimination ability was markedly reduced with a strongly reduced periodontal bone contact area. The endodontic status did not affect discrimination ability. A tendency towards better discrimination ability was seen when the cantilever sections without mucosal contacts were compared with those with mucosal contacts through pontics or saddles.

Alveolar Bone Loss↗

Prosthodontic decision making among general dentists in Sweden. III: The choice between fixed partial dentures and single implants.

PURPOSE: The purpose of this study was to describe how dentists evaluated the importance of various items related to a treatment choice between fixed partial dentures (FPD) and single implants, and to analyze if the differences could be explained by dentist-related variables such as social and demographic attributes, job situation, and attitudes. MATERIALS AND METHODS: Questionnaires were sent to a random sample of 2,059 Swedish general dentists, with a response rate of 76%. In the questionnaire, the choice between an FPD and a single-implant restoration in a clinical situation was presented. Fifteen items were constructed and the dentists were asked to mark on visual analogue scales the relative importance he or she gave the different items. The items were analyzed through principal components analysis, where a three-factor solution was obtained; the factors were labeled as "time," "health," and "comfort." The factors were run as dependent variables in multiple regression analyses. RESULTS: The items evaluated as most important were "prognosis for delivered treatment" and "patient's wish." Large individual differences were seen, but the differences between groups of dentists were small. Male dentists considered the "health" and the "comfort" factors to be more important compared to female dentists. The attitudinal variable "patient information" was significantly associated with the "time" factor and, inversely, with the "comfort" factor. CONCLUSION: Differences between individuals were great, but between groups of dentists the differences were only minor. Multivariately, the attitudinal variable "patient information" showed significant associations with the "time" and the "comfort" factors. Dentist-related variables explained little of the variations. The results further indicated a low personal knowledge concerning implant treatments. Psychologic methods might explain more of the individual differences in prosthodontic decision making, but these are not easily used in a questionnaire study.

Alveolar Process↗