PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Immediate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Immediate anterior tooth replacement using fibre-reinforced composite.

The loss of anterior teeth can be psychologically and socially damaging to the patient the trauma of which can be minimized by immediate replacement of the teeth, preferably using a fixed prosthesis. This paper describes the immediate replacement of a lateral incisor using a fibre-reinforced composite with the natural tooth as the pontic. The abutment teeth can be conserved with minimal or no preparation, thus keeping the technique reversible, and can be completed at the chairside thereby avoiding laboratory costs. It can be used as an interim measure or as a definitive prosthesis. The advantages of this technique over other methods are also discussed.

Cementation↗

[Therapeutic immediate denture, class II].

Without posterior support and because of dysfunction many people have very loose joints: their condyles are in a most retruded and downward situation. The occlusion cannot be stable in this relationship. The most retruded clinical position should not be used for prosthetic restoration. We must establish a therapeutic centric occlusion more anteriorly without increasing the vertical dimension. The amount of anterior condylar repositioning is determined by viewing the original TMJ tomographs. The position and the orientation of a normal occlusal plane can only be accurately determined by cephalometric analysis. This good occlusal scheme programmes the muscle coordination and maintains the anterior mandibular position.

Activator Appliances↗

Immediate restoration of single implants placed immediately after tooth extraction.

BACKGROUND: Some of the original surgical protocols for implant surgery have been reassessed to satisfy the patient's continuously increasing expectation for shorter rehabilitation time, improved esthetics, and increased comfort. The aim of this study was to evaluate the 12-month clinical success of 18 single-tooth implants inserted immediately after tooth extraction and restored the same day with non-functional loading. METHODS: A total of 18 patients (12 women and six men), 22 to 60 years old, were enrolled in this study. Eighteen single implants were inserted in fresh extraction sockets and immediately restored with temporary abutments and crowns. All experimental sites showed an absence of fenestrations or dehiscences of the bone walls and a residual gap between implant surfaces and surrounding bone walls < or =2 mm. All temporary prostheses were positioned the same day of surgery and were not in occlusal contact with opposing arches. The comparison between the baseline and 12-month visits was performed with the Student t test for paired data (statistically significant at a level of alpha = 0.05). RESULTS: During the 12-month follow-up period, one fixture was removed 4 weeks after implant placement following an abscess. All remaining implants healed uneventfully with no complications and were assessed as stable and successful at the 12-month checkup. No technical complications such as screw loosening, resin fracture, or pain during chewing were registered during the 12-month period. CONCLUSIONS: Within the limits of the data from this study, it can be suggested that immediate placement and restoration of a single implant can be a valid and successful option of treatment in the case of single compromised teeth. Moreover, this treatment protocol eliminates the need for removable provisional restoration and seems to maintain the preexisting architecture of soft and hard tissues in most cases. Nonetheless, further prospective and long-term studies are required to obtain a better insight into the limitations of this protocol.

Adult↗

Fibre reinforced composites--alternative for lost teeth replacement.

The loss of an anterior tooth can affect a patient psychologically and socially. This trauma can be minimized by the immediate replacement of the lost tooth, preferably using a fixed prosthesis. This paper describes the immediate replacement of anterior lost teeth by using fibre reinforced composite materials, although these techniques can be employed very successfully in the replacement of posterior teeth as well. The abutment teeth can be conserved, with little or no preparation, making this procedure truly minimally invasive and keeping the technique reversible. Additional advantages are that the procedure is completed at the chairside in a single visit, thereby avoiding laboratory costs and saving time while waiting for the finished prosthesis. This technique can be used as an interim measure or as a permanent prosthesis.

Aged↗

The immediate replacement of incisor teeth by cantilevered adhesive bridgework.

Adhesive bridgework is now an accepted alternative to conventional bridgework especially in teeth with minimal tooth substance loss and where occlusal forces are not excessive. Several designs have been described and these can be divided into bridges with perforated or non-perforated retainers. The perforated design was described by Rochette while the non-perforated design was pioneered by Livaditis and Thompson and became popularly known as the "Maryland bridge". It is now common practice to simply sandblast non-precious alloy retainers which are then bonded with specific chemically active adhesives.

Adult↗

Buccal and coronal bone augmentation using forced eruption and buccal root torque: a case report.

The following case report describes the buccal and coronal bone augmentation around an irretrievable tooth using forced eruption and buccal root torque for immediate nonsubmerged implant placement. A mandibular left second premolar with degree 2 mobility, severe buccal bone resorption, and interproximal angular bony defects was subjected to forced eruption and buccal root torque. Five months after this process, the tooth was displaced 15 mm coronally and the root apex faced buccally. Buccal and coronal bone augmentation and soft tissue enlargement were evident at reentry surgery. This technique enabled proper implant placement in a situation where the bone was compromised.

Alveolar Ridge Augmentation↗

Immediate loading of single-tooth ITI implants in the anterior maxilla: a prospective 5-year pilot study.

The aim of the present study was to evaluate the success rate of immediately loaded single-tooth ITI solid plasma-sprayed (TPS) implants in the maxilla. Eight implants were loaded immediately after placement in eight different patients, and were followed for five years. Temporary acrylic resin restorations, which were fabricated from impressions that were taken immediately after implant placement, were connected one week later. These temporary restorations were adjusted in order to avoid any direct occlusive contacts. After six months, the provisional crowns were replaced by definitive ceramic crowns. Regular follow-ups were performed during the investigation period. No implants were lost, and the mean marginal bone level for the eight implants increased by 0.53 mm (range - 0.83 to + 1.54 mm) from placement to the final examination. Only minor complications were noted, and overall patient satisfaction was high.

Adolescent↗

Immediate and early replacement implants and restorations.

UNLABELLED: There have been rapid developments in dental implant treatment protocols to reduce the time between implant placement and restoration. Implants may be placed immediately following tooth extraction or following a period of healing to allow resolution of residual infection or sufficient bone and soft tissue healing. Early restoration and loading of implants has to be carefully controlled to avoid increased failure and complications. Advantages and disadvantages of the various techniques are described. CLINICAL RELEVANCE: The clinician should adopt a treatment protocol that ensures a high success rate and a long-term functional and aesthetic implant restoration. Rapid treatment protocols can be considered when they do not compromise these goals, and the clinician is sufficiently experienced in their application.

Dental Implantation, Endosseous↗

A systematic review of marginal soft tissue at implants subjected to immediate loading or immediate restoration.

OBJECTIVES: The objective of this systematic review was to critically evaluate marginal soft-tissue aspects at implants subjected to immediate loading or immediate restoration. METHODS: An electronic Medline search from 1966 up to August 2005 was conducted to identify prospective and retrospective studies on immediate implant loading. The search strategy was complemented by hand searching in peer-reviewed journals. Studies reporting on soft-tissue aspects at implants subjected to immediate loading or immediate restoration and with a follow-up time of at least 1 year were included. Assessment of identified studies and data extraction was performed independently by two reviewers. An attempt was made to isolate and categorize studies with similar protocols in order to identify trends and relevant factors. Variables that were considered included marginal and interproximal soft-tissue stability, marginal plaque accumulation, probing depth, bleeding on probing, peri-implant mucositis and peri-implantitis. RESULTS: From an initial yield of 581 titles, 240 articles were selected for text analysis, finally resulting in 17 studies that met the inclusion criteria. Six studies on immediate implant loading or restoration were controlled studies, whereas the remainder was prospective case series. Seven studies reported on a 1-year data, and the longest follow-up within the included studies was 4 years. The total number of patients treated within the 17 studies was 432 including a total 706 implants studied. Overall, the articles reported on many different procedures and follow-up times, time points and evaluated soft-tissue parameters varied considerably between the different articles. CONCLUSION: Within the limits of the evaluated data it can be cautiously concluded that once immediately loaded or restored implants integrate successfully, they appear to show a soft-tissue reaction with regard to periodontal as well as morphologic aspects comparable with those of conventionally loaded implants. However, follow-up periods are generally short, number of patients and/or implants per study are few, and most studies present only limited data on peri-implant soft-tissue evaluation. More accurate long-term studies with a stronger study design (i.e., RCT) reporting more detailed on treatment and follow-up protocols are required to allow for proper comparisons and conclusions.

Dental Implantation, Endosseous↗

Immediate versus delayed functional loading of implants in the posterior mandible: a 2-year prospective clinical study of 12 consecutive cases.

The aim of this investigation was to evaluate the clinical success of immediately loaded implants versus implants loaded in a delayed fashion in the posterior mandible. Three implants were placed distal to the canines bilaterally in the edentulous distal mandibular ridges of 12 patients. One side was randomly selected for placement of three implants (delayed loading; control sites) with a progressive thread design for submerged healing, and after 3 months the implants were exposed and loaded with provisional splinted crowns, which were replaced 6 weeks later by the definitive restorations. Three additional implants (immediately loaded; test sites), of the same size were placed in the contralateral side of the mandible. The test implants had abutments placed and were loaded immediately using the same protocol as the control implants. After a mean loading period of 25.3 months, the patients showed normal mean clinical values without significant differences (P < 0.05) for test and control implants, respectively, as follows: Plaque Index: 0.4 versus 0.8; Sulcus Bleeding Index: 0.5 versus 0.3; probing pocket depth: 1.9 mm versus 2.1 mm; width of keratinized mucosa: 2.5 mm versus 3.3 mm; Periotest value: -3.7 versus -3.2. Twenty-nine of the examined sites showed no bone loss. After 2 years of loading in the posterior mandible, test and control implants had the same prognosis.

Bicuspid↗

One-piece root-form implants: a return to simplicity.

Immediately loaded 1-piece dental implants were a standard treatment modality more than 30 years ago and, on occasion, resulted in excellent clinical successes. However, this technology also became associated with significant failure rates and fell out of favor. Since then, understanding of the site requirements and placement procedures necessary to ensure primary stability have advanced considerably. Implant designs and surface treatments also have evolved. In light of this greater understanding, a 1-piece root-form implant system has been developed. This article describes 4 clinical cases in which use of the new system was employed. In each case, the results included excellent stability, esthetics, and patient satisfaction.

Adolescent↗

Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and loading.

PURPOSE: This report of a clinical patient series indicates the relative safety and illustrates the procedures involved in the extraction of remaining teeth followed by immediate implant placement and loading with a simple acrylic resin fixed denture. MATERIALS AND METHODS: Ten consecutive patients who selected tooth extraction and implant-supported fixed denture rehabilitation of the mandible were treated using a 1-visit approach for extraction, implant placement, and restoration. Healthy individuals (10 women) were treated under local anesthesia. Fifty-four implants were placed in 10 patients. Five or 6 Astra Tech implants (11 or 13 mm long) were placed into the edentulous parasymphyseal region of the mandible. Four to 6 implants (48 of 54) were immediately loaded by the fabrication of a simple acrylic resin fixed denture. The criterion for loading was clinical judgment of primary stability, ie, the absence of axial or lateral mobility with physical resistance to rotation. Patients were recalled at 1, 3, and 12 weeks. At 12 weeks, impressions were made for the fabrication of a screw-retained fixed denture. The fixed dentures were completed using conventional fabrication and prosthetic techniques. RESULTS: After a period of 6 to 18 months, all 54 implants had survived and were considered 100% successful by independent testing of mobility and radiographic evidence of osseointegration. There were no surgical complications. Fracture and debonding of the acrylic resin provisional denture occurred for 1 patient during the first 12 weeks of treatment. DISCUSSION: Advantages to extraction with simultaneous replacement include the maintenance of vertical dimension, elimination of reline procedures and interim denture therapy, and potential improvement of soft tissue healing. CONCLUSION: This therapeutic approach simplifies patient care without apparent additional risk.

Adult↗

Preliminary report of immediately loaded Altiva Natural Tooth Replacement dental implants.

BACKGROUND: Osseointegration may be described as a direct contact between living bone and an alloplastic implant. It is thought that a period of undisturbed healing is required to ensure osseointegration. The length of the healing period is dependent on a number of factors, such as implant material, surface configuration, site preparation technique, bone quality, healing capacity of the osteotomy, and implant design. Elimination of the healing period offers distinct advantages in terms of cost of therapy and convenience to patients. Recently, a new one-piece implant design was proposed that provides improved stability of the implant to allow immediate support of an interim prosthesis. PURPOSE: This article presents the initial clinical experiences when the Altiva Natural Tooth Replacement one-piece implant was used in a human clinical trial. MATERIALS AND METHODS: This was a prospective multicenter study of the placement and immediate loading of the one-piece implant. A total of 142 implants were placed in the jaws of 93 patients. Implants were placed consecutively and were followed at specified intervals in three private clinical practices. Clinical performance was recorded relative to implant survival and prosthesis support. RESULTS: The implant survival rate was 93.7%, with similar responses in the maxilla (95.0%) and the mandible (92.7%). When implant failure occurred, it was observed as mobility without infection within 3 to 5 weeks of implant insertion. CONCLUSIONS: On the basis of this trial, there is promising evidence that this implant design can succeed at rates similar to other designs that require conventional healing times.

Adult↗

Achieving aesthetic success with an immediate-function implant and customized abutment and coping.

UNLABELLED: The absence of teeth in the anterior region often results in a number of negative consequences compromising appearance and facial anatomy, as well as patients' self-esteem and social behavior. Dental implants have increasingly become a viable option for achieving natural-looking restorations. The success of anterior restorations, however, depends upon several factors. The following case presentation discusses these factors as well as the implementation of clinical and laboratory procedures for the restoration of a missing anterior tooth. LEARNING OBJECTIVES: This article demonstrates an implant surgical procedure and restorative sequence used to replace a fractured single anterior tooth. Upon reading this article, the reader should: Understand how dental implants can be a viable solution based upon factors within the proximity of the region being restored. Realize that optimal aesthetics can be achieved when the final abutment is installed at the time of implant placement.

Adolescent↗

Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results.

Restoring patients with implant-supported fixed-detachable bridges according to the protocol established by Brånemark necessitates a period of several months when complete dentures must be worn to allow for a stress-free healing period of the implants. For many patients, especially when they still have some natural teeth remaining, this is unacceptable. An approach was developed that overcomes these limitations, offering an alternative to the transitional removable approach. Five or six Nobelpharma fixtures were placed between and two additional fixtures were placed distolingual to the foramina. Abutments were connected at implant insertion to these two fixtures and to one fixture in the symphyseal region. The remaining fixtures were allowed to heal in the conventional manner. A previously constructed mandibular denture was converted to a fixed bridge supported by these three implants. This method was successfully applied in seven patients who were reconstructed with mandibular fixed-detachable bridges without ever wearing a removable prosthesis. The overall, long-term implant therapy was not adversely affected by this technique.

Aged↗

Immediate and early implant loading protocols: a literature review of clinical studies.

The purpose of this literature review is to present the outcomes of clinical studies on immediate and early loading protocols, identify shortcomings, and suggest a number of questions that still require exploration. English language clinical studies, limited to peer-reviewed journals between 1975 and 2004, were reviewed to identify treatment outcomes with these loading protocols. The data were tabulated from studies reporting on patients treated with fixed and overdenture prostheses. The former included partially edentulous patients treated with single or multi-unit prostheses. Within the limitations of this review, it can be concluded that these treatment protocols are predictable in the anterior mandible, irrespective of implant type, surface topography, and prosthesis design (success rates 90%-100%). Limited evidence for the edentulous maxilla (success rates 90%-100%) and the partially edentulous patient (success rates 93%-100%) are available, underscoring the need for further research. Studies suggest that to achieve predictable results in extraction sites, implant placement should be restricted to sites without a history of periodontal involvement (success rates 61%-100%). A number of questions require further exploration. There is a need to thoroughly investigate clinical outcomes to measure the economic benefit of these protocols and the impact of treatment on a patient's quality of life. Furthermore, more accurate long-term studies reporting on treatment protocols for separate clinical situations are required to allow meaningful comparisons.

Dental Implantation, Endosseous↗

A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading.

PURPOSE: In this study, standard Brånemark System implants and Brånemark TiUnite implants were evaluated regarding primary stability and placement torque. The correlation between placement torque and primary stability as well as the influence of implant design on placement torque and primary stability were examined. MATERIALS AND METHODS: Twelve patients who presented bilateral loss of either maxillary lateral incisors or premolars were treated with 24 immediately loaded dental implants. Each patient received 1 standard 3.75 x 13-mm Brånemark System implant and one 3.75 x 13-mm TiUnite Mk III implant. One at a time, each implant was connected by a transducer to an Osstell machine that automatically translated a resonance frequency value for the implant into an implant stability quotient value. Osseocare equipment was used to measure the placement torque for both types of implants. RESULTS: Statistical analysis showed higher mean values for standard implants in relation to placement torque and resonance frequency values. DISCUSSION: There was no overall correlation between placement torque and resonance frequency values; this finding supported previous studies. CONCLUSION: Stability was shown to be higher for the standard implants. Mean values of torque resistance were higher for the standard implants than for the TiUnite implants. Implant design appeared to influence primary stability and placement torque.

Adult↗

Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants.

PURPOSE: The purpose of this study is to evaluate prospectively survival and success rates of implants placed in the interforaminal area of edentulous mandibles and immediately loaded with an implant-supported overdenture. MATERIALS AND METHODS: Eighty-two patients, 33 males and 49 females, aged between 42 and 87 years (mean age 58.6 yr), presenting edentulous mandibles were rehabilitated with an implant-supported overdenture in the mandible. Three hundred twenty-eight screw-type osseointegrated implants (164 Ha-Ti, Mathys Dental, Bettlach, Switzerland; 84 ITI Dental Implant System, Straumann Institute, Waldenburg, Switzerland; 40 Brånemark Conical, Nobel Biocare AB, Gothenburg, Sweden; 40 Frialoc, Friatec, AG Mannheiti, Germany), were placed in the intraforaminal area of the mental symphysis (4 implants per patient). Immediately after implant placement, a U-shaped gold or titanium bar was fabricated and implants were rigidly connected with the bar and immediately loaded with an implant-retained overdenture. Success rate of implants was evaluated clinically and radiographically every year after the loading of the prostheses according to the following parameters: (1) absence of clinical mobility of implants tested individually after bar removal, (2) absence of periimplant radiolucency evaluated on panoramic radiographs, (3) absence of pain and radiologic or clinical signs of neural lesion, and (4) periimplant bone resorption mesial and distal to each implant less than 0.2 mm after the first year of prosthetic load. RESULTS: Of 328 implants placed, 296 were followed up from a minimum of 36 months to a maximum of 96 months, with a mean follow-up of 62 months. Seven implants in 6 different patients were removed owing to loss of osseointegration, whereas 18 implants, although still osseointegrated, did not fulfill success criteria due to bone resorption > 0.2 mm/year after the first year of loading. Despite implant losses, all patients maintained their bars supporting overdentures, although in 6 patients they were supported by 3 instead of 4 implants. The only patient who lost 2 implants received 2 new implants, which survived normally. Therefore, the absolute success and survival rates were 91.6% and 97.6%, respectively, whereas the cumulative survival and success rates of implants obtained with a life table analysis were 96.1% and 88.2%, respectively. CONCLUSIONS: Results of this study seem to demonstrate that survival and success rates of immediately loaded implants placed in the intraforaminal area of the mandible and rigidly connected with a bar through an implant-supported overdenture are consistent with those reported in the international literature as far as delayed loading is concerned after 3 years of loading. After longer observation times, this study demonstrated that, while survival rates of implants and bar-supported overdentures are still consistent with results published in the international literature pertaining to delayed loading, a moderate decrease in success rates of implants was found. Nevertheless, it must be stressed that this decrease (88.8 and 90.4% after a 7- to 8-year observation period for Ha-Ti and ITI implants) is related only to two implant systems; no data are available for the other two implant systems because of the shorter follow-up period.

Adult↗