PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Removable”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Laboratory considerations in rotational path removable partial dentures.

Clinical indications and contraindications have been well covered in the literature for rotational path removable partial dentures (RPDs). However, only minimal coverage has been devoted to problems encountered that may prevent the proper fabrication of these restorations by dental technicians. The purpose of this article is to illustrate 2 problems that dental technicians occasionally encounter that make the fabrication of rotational path RPDs difficult or impossible. Design modifications by the clinician can eliminate 2 problems faced by technicians fabricating rotational path RPDs.

Contraindications↗

Evaluation of a computer-aided learning program in removable partial denture framework designing.

Assessment of a computer-assisted learning (CAL) program dealing with designing removable partial dentures was performed as both formative and summative evaluation. Formative evaluation was obtained through open-ended questions in a written questionnaire administered to 60 junior students from two Australian Dental Schools and through observation of four groups of these students as they worked through the program. Formative evaluation, fundamental to completion of the program, led to several changes and additions. Observation of the students using the program during its final stages of development was one of the most informative and helpful parts of the evaluation. It allowed nuances of expression and body language to be noted that would not have been apparent in written or numerical data. Summative evaluation was obtained through structured questions in the questionnaire and through a post-CAL test under examination conditions. Summative assessment showed that students could attain a desired standard of knowledge if a lecture series was replaced by the CAL program; that the program was user-friendly, even for students with little or no computer experience; and that most students considered it to be a useful learning resource. More than half the students were concerned about using CAL to replace human instruction. It is significant that students were particularly impressed by aspects of the program that could not be duplicated by a book; the interactive nature of the learning process and the ability to rotate the diagnostic casts. This highlights the need for CAL programs to use the full potential of computer capability, rather than merely replicate a textbook on a screen.

Computer-Assisted Instruction↗

The use of removable partial denture splints in the treatment of postsurgical tooth mobility.

The theory and clinical use of removable partial denture splints has been offered as a tenable solution to the problem of postsurgical tooth mobility. The close cooperation of the periodontic and prosthetic specialties is in many cases vital to the ultimate success of treatment and longevity of the dentition. Although not presented as a panacea, it is hoped that clinicians will bear this clinical entity in mind as an option in the treatment of periodontally debilitated dentitions.

Denture Design↗

[A systematic approach for removable partial denture design].

Patients' attitudes, medical, surgical and financial considerations lead to the use of a removable partial denture (RPD) as the chosen prosthetic restoration even in the "dental implant era". The aim of this article is to describe a systematic approach to RPD design, so the RPD will be a long-term solution that will not harm the remaining oral tissues. There is an unlimited RPD design options. Choosing the right one involves considering biochemical factors, aesthetics and patients' comfort. A systematic approach starts with a correct diagnosis of the remaining hard and soft tissues, followed by a careful planning of support, stability and retention in that order. Additional elements should be added only at a later stage. A systematic track starting with a preliminary design, surveying of the model and analyzing the preliminary design on that surveyed model. If needed, that track should be reversed until an acceptable design is found. Support should ideally be achieved by using metal rests on healthy tooth structure. Tooth supported RPD are the most convenient ones and have a very good long-term prognosis. Old restorations or caries might impose changes from the ideal supporting rests. When posterior teeth are missing or when the edentulous area is vast, tooth-tissue supported RPD are used. In these cases one should gain initial support from the teeth and an additional support from the soft tissues. A denture base that is similar to a full denture base that would have been prepared for a fully edentulous patient should achieve this. If the prognosis of the potential supporting teeth is poor, a tissue-tooth supported RPD is considered. In these cases, the denture base is the primary supporting element, and stress relieving clasp-assemblies such as the RPI/RPA should be considered. Stability is achieved primarily by metal contacts between teeth and the metal framework of the RPD. In fact, any embracing part of the clasp assembly and a correct denture base can contribute to the stability. The distal parts of the retentive clasps produce the active retention. Since these parts generate lateral forces on the abutment teeth, a reciprocating element should be used. True reciprocation can only be achieved if the reciprocating element touches the tooth before the retentive clasp. After designing support, stability and retention, other parts should be considered. When a distal extension RPD is considered, an indirect retainer should be incorporated into the framework in order to prevent upward rotational movement of the denture. The major connector converts forces from one side to the other. In the upper jaw, that part acts also as a supporting element in Kennedy class I and class II cases. In other cases, a minimal type of a major connector should be chosen. As for minor connectors, these should only be added if other parts--such as guiding planes--couldn't be used for the purpose of connecting functional elements to the major connector. In any case, a 5 mm distance between two adjacent minor connectors should be allowed in order to prevent food from being trapped in that space. A systematic approach starts with diagnosis of the remaining tissues and with finding the correct prosthetic solution with the patient. If a RPD is the chosen solution, start designing with analysis of support, followed by stability and only then, decide upon the necessary retentive elements. All other parts should be considered later. Such a systematic approach will ensure a long-term solution and a happy patient.

Dental Abutments↗

Cast connectors as cores for ceramometal pontics on removable partial dentures and for splinting anterior crowns.

A cast connector is a solderless union between two metal components, an alternative to soldering. Cast connectors depend upon mechanical retention for their strength and integrity and are mostly used in repairing or adding to prostheses cast in base metal alloys. Two techniques using cast connectors are described. One is for a removable partial denture that requires the replacement of an anterior tooth or teeth incorporating diastemas or unusual surface anatomy and color variations. Stock denture teeth may not adequately replicate such teeth. A solution to the problem is to extend a porcelain-compatible base metal cast connector from the removable partial denture framework onto the pontic site. A ceramometal pontic reproducing the unusual characteristics of the natural teeth may then be placed by vacuum-firing porcelain directly onto the framework. A second technique is described whereby multiple ceramometal anterior crowns may be splinted together by creating interproximal retentive zones in the frameworks, casting connectors into the retentive zones, and proceeding with porcelain application.

Acrylic Resins↗

Cantilever bridges or removable partial dentures in geriatric patients: a two-year study.

The purpose of this study was to compare prosthetic, functional and occlusal conditions in twenty-seven patients treated with distally extending cantilever bridges and twenty-six patients treated with removable partial dentures (RPD) in the mandible. All patients had a complete upper denture. Mean age of the patients in both groups was about 69 years. The patients were under a supervised oral hygiene care throughout the 2-year study period. There were 6.9 +/- 1.7 mandibular teeth left in the bridge group and 7.5 +/- 1.7 in the RPD group and the mean number of posterior teeth (natural teeth/denture teeth/pontics) in occlusion was 4.1 +/- 1.1 and 7.3 +/- 1.4, respectively. During the study period signs and symptoms of mandibular dysfunction became significantly aggravated in the RPD group, P less than 0.05. A balanced occlusion in the muscular contact position was observed in 90% of the patients in the bridge group and in 76% of the RPD wearers. During the study period the need for dental or prosthetic treatment was negligible in the patients treated with bridges. In the RPD group, twenty-two teeth were restored with fillings due to caries and in eight patients major adjustments of the sublingual bar were necessary due to irritation of the oral mucosa. This study has shown that treatment with distally extending cantilever bridges in the mandible is a favourable alternative to treatment with removable partial dentures in elderly patients with a reduced dentition.

Aged↗

A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying.

Although computer-aided design and manufacture techniques have shown some promising applications in the fabrication of crowns, inlays, and maxillofacial and oral surgery, the field of removable prosthodontics has not embraced these technologies so far. This article describes the development and investigation of computer-aided techniques that may eventually enable prosthodontic procedures such as surveying and the production of sacrificial patterns to be performed digitally. A 3-dimensional computer model of a conventional cast from a patient was obtained using an optical surface capture device (a scanner). The shape of a number of components of a removable partial denture framework was modeled on the 3-dimensional scan electronically, using computer-aided design software. A physical plastic shape of the components was produced using a Rapid Prototyping machine and used as a sacrificial pattern. Techniques to allow digital cast surveying before the production of sacrificial patterns were also developed. The results show that digital dental surveying and machine-produced sacrificial patterns can be accomplished. This article forms a basis for further developments leading to a fully integrated approach to the computer-aided design and fabrication of removable partial denture frameworks.

Computer Simulation↗

Photoelastic analysis and comparison of force-transmission characteristics of intracoronal attachments with clasp distal-extension removable partial dentures.

This investigation photoelastically compared the load-transfer characteristics of various bilateral distal-extension removable partial denture designs embodying intracoronal attachments and clasp assemblies. Six distal-extension designs that included the RPI clasp assembly, cast circumferential clasp, P.D. locking semiprecision, Thompson dowel nonlocking semiprecision, and McCollum and Stern G/L precision attachments were tested. Each prosthesis was subjected to various simulated occlusal loads. Evaluation of the load-transfer characteristics of the various designs was based on comparison of the recorded isochromatic fringe distributions. The RPI clasp assembly generated the most uniform stresses. In general, the four intracoronal retainer frameworks produced higher stresses than did the two clasp frameworks. The highest stresses were developed by the Stern G/L precision attachment.

Bicuspid↗

The hinged-clasp assembly removable partial denture.

Severe undercuts and malpositioning of teeth can create problems with the path of insertion of removable partial dentures. Prostheses that have conventional clasp designs are not well-suited for these situations because a common path of placement must exist for all clasps. A technique that incorporates a hinged-clasp assembly to overcome this problem is described.

Dental Abutments↗

An accurate method for occlusal registration and altered-cast impression for removable partial dentures during the same visit as the framework try-in.

Preparation of mandibular distal-extension removable partial dentures usually requires a secondary impression (the altered-cast impression) to improve the stability of the prosthesis. A potential problem with conventional altered-cast impression procedures is incorrect or incomplete seating of the framework in the mouth or on the cast. This article describes a procedure for obtaining the interjaw relationship and an accurate altered-cast impression in a single appointment (that of the framework try-in).

Acrylic Resins↗

A 25 year longitudinal study of patients treated with removable partial dentures.

A 25 year longitudinal study was carried out on a number of patients fitted with removable partial dentures (RPDs) in 1969. Before the prosthetic treatment all patients were given oral hygiene motivation and instructions in order to create a high level of co-operation. The RPDs, most of which were lower bilateral distal extension dentures, were carefully planned and designed. During the first 10 years the patients were examined in our clinic at yearly intervals at which time encouragement and reinstruction regarding oral hygiene were given and various treatment procedures were performed as required. After the initial 10 years the patients were advised, for practical reasons, to continue to have yearly controls on their own initiative. Of the initial 30 patients from 1969, 23 were still alive in 1994, all of whom were examined. In five of those 23 the original RPD situation had changed more or less due mainly to general illness contracted and/or change to other therapies. In the remaining 18 patients wearing in total 20 RPDs, 13 (65%) of the original RPDs were still functioning. Seven RPDs were new with principally the same design as the original ones. Among these 18 patients the number of lost teeth, the number of new DF surfaces and the increased number of endodontically treated teeth were few. No apparent changes took place regarding the periodontal condition during the follow-up period.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

[The functional capability of removable partial dentures in various classifications of reduced dentitions].

Based on the functional capability of the prosthesis, 462 removable partial dentures worn by 351 patients were grouped into five classifications (according to the topographical distribution of the remaining teeth E. Körber, K. Eichner and V. L. Steffel, and according to the number of remaining teeth per jaw). A statistical evaluation of the data showed that the Steffel classification provided the most reliable prognostic indications for the expected functional state.

Denture Repair↗

Dimensional changes in casting titanium removable partial denture frameworks.

The difficulties encountered in casting titanium and its alloys have until recently hindered any widespread use of titanium in restorative dentistry. Now both equipment and materials are available for the routine use of titanium in the dental laboratory. This study used one of the casting systems and examined dimensional changes that occur during the construction of a removable partial denture framework. Nineteen castings were measured for horizontal and vertical plane changes. Results show these castings to have cross arch contraction, vertical plane expansion, and near neutral anterio-posterior change. It seems that pure titanium is within the range of dimension changes generally accepted for base metal removable partial denture alloys of the nickel-chromium variety.

Dental Casting Investment↗

Evaluation of prefabricated lingual rest seats for removable partial dentures.

An investigation into the feasibility of using prefabricated lingual rest seats bonded to mandibular canines and incisors with an orthodontic enamel bonding system was undertaken. 1. A prefabricated lingual rest seat was designed and constructed to closely approximate the lingual contours of anterior teeth. 2. An in vitro study compared the mean failure loads of three orthodontic bonding systems. Two of the three have mean failure loads that are greater than twice the maximum occlusal-gingival forces that were applied to the abutments by removable partial dentures in the study by Maxfield et al. 3. A demonstration of the clinical feasibility of using these prefabricated lingual rests for support of removable partial dentures has been reported.

Dental Abutments↗

All-cast-titanium removable partial denture for a patient with a severely reduced interarch distance: a case report.

A patient had a maxillary posterior edentulous area and severely reduced interarch distance that precluded the use of a conventional removable partial denture. An all-cast-titanium denture base and occlusal surface was designed to fabricate a removable denture to restore the edentulous area. Titanium was cast in a centrifugal casting machine with electric are melting design. The desirable characteristics of titanium, such as favorable mechanical properties, low density, and comparatively low cost, make this metal particularly effective and suitable for construction of an all-cast-metal denture base with a metal occlusal surface.

Adult↗

Removable partial denture abutments restored with all-ceramic surveyed crowns.

All-ceramic crowns are used as alternatives to conventional metal-ceramic crowns for the restoration of single teeth. Traditionally all-ceramic restorations possessed physical properties that contraindicated their use in many treatment situations. The strength that zirconia ceramics exhibit seems to support the hypothesis that, in specific situations, an all-ceramic crown may be used to restore removable partial denture (RPD) abutments in areas previously reserved for metal or metal-ceramic restorations. Abutments for RPDs may now be fabricated with Procera AllZirkon with the classically prepared guide planes and rest seats. This article provides an overview of a technique for the fabrication of a zirconia-based crown to be used in conjunction with removable partial dentures using the Procera CAD/CAM technology.

Ceramics↗