Mechanisms of aortic valve incompetence: finite-element modeling of Marfan syndrome.

OBJECTIVES: Progressive aortic root dilatation and an increased aortic root elastic modulus have been documented in persons with Marfan syndrome. To examine the effect of aortic root dilatation and increased elastic modulus on leaflet stress, strain, and coaptation, we used a finite-element model. METHODS: The normal model incorporated the geometry, tissue thickness, and anisotropic elastic moduli of normal human roots and valves. Four Marfan models were evaluated, in which the diameter of the aortic root was dilated by 5%, 15%, 30%, and 50%. Aortic root elastic modulus in the 4 Marfan models was doubled. Under diastolic pressure, regional stresses and strains were evaluated, and the percentage of leaflet coaptation was calculated. RESULTS: Root dilatation and stiffening significantly increased regional leaflet stress and strain compared with normal levels. Stress increases ranged from 80% to 360% and strain increases ranged from 60% to 200% in the 50% dilated Marfan model. Leaflet stresses and strains were disproportionately high at the attachment edge and coaptation area. Leaflet coaptation was decreased by approximately 20% in the 50% root dilatation model. CONCLUSIONS: Increasing root dilatation and root elastic modulus to simulate Marfan syndrome significantly increases leaflet stress and strain and reduces coaptation in an otherwise normal aortic valve. These alterations may influence the decision to use valve-sparing aortic root replacement procedures in patients with Marfan syndrome.

Aortic Valve↗

Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement.

PURPOSE: This study sought to establish the relationships between bone density, elastic modulus, and ultimate compressive strength of trabecular bone in the human mandible, and to determine the influence that the cortical plates have on these values. MATERIALS AND METHODS: Nine fresh-frozen human mandibles between the ages of 56 and 90 years were cut into anterior (incisors and canine), middle (premolars), and distal (molars) sections. Seventy-six cylindrical trabecular bone specimens with bone marrow in situ were then prepared and tested in compression in the vertical direction. These tests were performed at a constant strain rate of 0.01 s(-1) with and without the presence of the cortical plates. RESULT: The density of mandibular trabecular specimens with bone marrow in situ ranged from 0.85 to 1.53 g/cm3, with a mean value of 1.14 g/cm3 (SD = 0.15). With the cortical plates present, the elastic modulus ranged from 24.9 to 240.0 megapascals (MPa), with a mean value of 96.2 MPa (standard deviation (SD) = 40.6). Without the cortical plates present, the elastic modulus ranged from 3.5 to 125.6 MPa, with a mean value of 56.0 MPa (SD = 29.6). The ultimate compressive strength of the trabecular bone ranged from 0.22 to 10.44 MPa, with a mean value of 3.9 MPa (SD = 2.7). CONCLUSION: This study indicates that the trabecular bone in the human mandible possesses significantly higher density, elastic modulus, and ultimate compressive strength in the anterior region than in either the middle or distal regions. The absence of cortical plates decreases the bone elastic modulus. These findings quantitatively confirm the need for clinical awareness in altering implant treatment plans and/or design in relation to bone density and the presence of the cortical plates.

Adolescent↗

Relationships between the modulus of elasticity and tensile strength for pharmaceutical drugs and excipients.

The relationship between the modulus of elasticity and tensile strength for a variety of pharmaceutical drugs and excipients has been explored as a means of generating algorithms for use in computer simulations and expert systems. From literature data two equations have been developed to enable the formulator, from knowledge of one property, to predict the other with a reasonable degree of accuracy. Such relationships are invaluable for use in computer simulation programs or formulation expert systems, enabling formulators to screen potential formulations quickly without the need for extensive experimental work.

Algorithms↗

Glucocorticoid-treated mice have localized changes in trabecular bone material properties and osteocyte lacunar size that are not observed in placebo-treated or estrogen-deficient mice.

UNLABELLED: This study compares changes in bone microstructure in 6-month-old male GC-treated and female ovariectomized mice to their respective controls. In addition to a reduction in trabecular bone volume, GC treatment reduced bone mineral and elastic modulus of bone adjacent to osteocytes that was not observed in control mice nor estrogen-deficient mice. These microstructural changes in combination with the macrostructural changes could amplify the bone fragility in this metabolic bone disease. INTRODUCTION: Patients with glucocorticoid (GC)-induced secondary osteoporosis tend to fracture at higher bone mineral densities than patients with postmenopausal osteoporosis. This suggests that GCs may alter bone material properties in addition to BMD and bone macrostructure. MATERIALS AND METHODS: Changes in trabecular bone structure, elastic modulus, and mineral to matrix ratio of the fifth lumbar vertebrae was assessed in prednisolone-treated mice and placebo-treated controls for comparison with estrogen-deficient mice and sham-operated controls. Compression testing of the third lumbar vertebrae was performed to assess whole bone strength. RESULTS: Significant reductions in trabecular bone volume and whole bone strength occurred in both prednisolone-treated and estrogen-deficient mice compared with controls after 21 days (p < 0.05). The average elastic modulus over the entire surface of each trabecula was similar in all the experimental groups. However, localized changes within the trabeculae in areas surrounding the osteocyte lacunae were observed only in the prednisolone-treated mice. The size of the osteocyte lacunae was increased, reduced elastic modulus around the lacunae was observed, and a "halo" of hypomineralized bone surrounding the lacunae was observed. This was associated with reduced (nearly 40%) mineral to matrix ratio determined by Raman microspectroscopy. These localized changes in elastic modulus and bone mineral to matrix ratio were not observed in the other three experimental groups. CONCLUSIONS: Based on these results, it seems that GCs may have direct effects on osteocytes, resulting in a modification of their microenvironment. These changes, including an enlargement of their lacunar space and the generation of a surrounding sphere of hypomineralized bone, seem to produce highly localized changes in bone material properties that may influence fracture risk.

Animals↗

[Biomechanical properties of the acromioclavicular joints].

The purpose of this study was to investigate the biomechanical properties of the cartilagenous element of the acromioclavicular joint. Experimental specimens of the distal end of the clavicle were selected from operative excisions from patients with acromioclavicular joint dislocation. Dynamic stiffness, tan delta, cartilagenous thickness, elastic modulus and creep modulus were measured with a Biomechanical Spectrometer. The results were as follows: There was a negative correlation between age and values of dynamic stiffness as well as between age and the values of elastic modulus. The values of dynamic stiffness, tan delta, cartilagenous thickness, elastic modulus and creep modulus correlated significantly with the number of days after injury. The values for the anterior parts, excluding dynamic stiffness, were markedly higher than those for the other parts. Aging of the articular cartilage may be a factor in the lowering of dynamic stiffness and elastic modulus. Degenerative change is evidenced by a decrease in cartilaginous thickness and a softening of the articular cartilage. The anterior part of the articular surface showed good load-relaxation and viscoelastic properties. The anterior parts may act as the center of the rotational axis of the clavicle and the fulcrum of the horizontal adduction of the scapula when the arm is raised.

Acromioclavicular Joint↗

Bend testing of wrought wire removable partial denture alloys.

The flexibility of the wrought wire clasp is related to a number of factors, including the type and gauge of the alloy. The purpose of this study was to compare the bend behavior of five wrought wire alloys used in removable partial dentures. The alloys and their gauge diameters (in millimeters) were Ticonium (18, 19, 20), platinum-gold-palladium (18, 19), Wironium (18, 20), Jelenko Standard (18, 19, 20), and Denture Clasp (18, 19, 20). A total of 12 to 15 samples of each dental alloy were tested. Three-point bending was performed on a servohydraulic testing system controlled by a computer at 1.00 mm/sec until fracture or actuator contact occurred. Maximum stress and elastic modulus in bending were determined for each gauge diameter. Analysis of variance and post hoc Scheffe statistical analyses revealed significant maximum stress and elastic modulus in bending differences for different alloys of the same gauge and for different gauges of the same alloy. The choice of material and the gauge diameter significantly influenced the mechanical property of bending for wrought wire removable partial denture alloys. The Ticonium alloy had the greatest elastic modulus (stiffest) at all levels and the Denture Clasp and the Jelenko Standard alloys had the lowest elastic modulus (most flexible). These data indicate that knowledge of the bending properties of an alloy is equally as important as the gauge size when selecting a wire clasp.

Analysis of Variance↗

Elastic behavior of zymogen granule membranes in response to changes in pH and pCa.

In the process of secretion, the membrane of secretory granules is expected to change its elastic behavior. Elastic modulus of the membrane of zymogen granules, prepared from the rat pancreas acinar cell, was measured by an osmotic swelling method. The elastic modulus of the granule membrane at pCa 8 reduced from the maximal value of 230 dyn/cm at pH 6.0 to almost zero at pH 7.5. In a cytosol of an acinar cell, calcium ions play an important role as a second messenger in secretion. The elastic modulus of the granule membrane reduced in a sigmoidal fashion at pCa between 7.0 and 6.0. This range of pCa corresponds to a physiological rise of free Ca2+ concentrations in the cell cytosol when stimulated by external secretagogues. Reduction of the elastic modulus indicates that the state of the granule membrane switches to a more flexible one in which the granule is easy to appose to the cell plasma membrane and then swell as a final step of exocytosis.

Animals↗

Aging, vertebral density, and disc degeneration alter the tensile stress-strain characteristics of the human anterior longitudinal ligament.

The mechanical properties of the human lumbar anterior longitudinal ligament were investigated, and the influence of aging, disc degeneration, and vertebral bone density on these properties was determined. Tensile mechanical properties of the vertebra-anterior longitudinal ligament-vertebra complex were determined for 16 segments from cadavera of individuals who had been 21-79 years old (mean, 52.1 years) at the time of death. Regional strain patterns associated with three sites across the width and three sites along the length of the anterior longitudinal ligament were measured with use of a video-based motion analysis system. In the young, normal anterior longitudinal ligament, the elastic moduli of the insertion and substance regions of the ligament were similar (approximately 500 MPa). During aging (21-79 years), the elastic modulus of the substance region increased 2-fold, whereas the elastic modulus of the insertion decreased 3-fold; this resulted in an approximately 5-fold difference in elastic modulus between these regions in the older spine. The strength of the bone-ligament complex decreased approximately 2-fold (from 29 to 13 MPa) over this same age range. The outer portion of the anterior longitudinal ligament consistently had the highest peak tensile strains (11.8 +/- 2.7%) in all of the specimens examined. Preparations with nondegenerated discs and high bone density were significantly stronger (66%) and failed in the ligament substance; in contrast, segments from older individuals with degenerated discs and lower bone density failed in the ligament insertion regions.

Adult↗

Effects of chemical modification, tropomyosin, and myosin subfragment 1 on the yield strength and critical concentration of F-actin.

The effects of coupling with tetramethylrhodamine-5-iodoacetamide and of the decoration with tropomyosin and with myosin subfragment 1 on the elastic properties of F-actin filament are investigated. At 22 degrees C, in 15 mM orthophosphate and 3 mM MgCl2, tetramethylrhodamine F-actin displays a yield strength of 3.69 +/- 0.213 pN and an elastic modulus by stretching of 0.91 MPa. Decoration with tropomyosin increases the yield strength of tetramethylrhodamine F-actin to 10.51 +/- 0.24 pN and the elastic modulus by stretching to 23-75 MPa. Mixtures of myosin subfragment 1 and tetramethylrhodamine F-actin at the 0.2:1, 0.4:1, 0.6:1, 0.8:1, and 1:1 molar ratios are also studied. Both yield strength and the elastic modulus by stretching are found to increase progressively with the ratio. At the 1:1 molar ratio, the yield strength is 15.81 +/- 0.26 pN and the elastic modulus by stretching is 13.45 to 40 MPa. Decoration of tetramethylrhodamine F-actin with both tropomyosin and myosin subfragment 1, at the 1:1 molar ratio with the actin monomer, produces filaments with an yield strength of 22.3 +/- 0.48 pN.

Actins↗

Membrane elastic shear modulus of red blood cells with glucose-6-phosphate dehydrogenase and pyruvatekinase enzymopathies.

The membrane elastic shear modulus mu determined by a micropipette technique was found to be elevated by 25% to 200% for red blood cells (RBC) from 7 patients with glucose-6-phosphate dehydrogenase (G-6-PD) and 9 patients with pyruvate-kinase (PK) enzymopathies above the mean value for normal controls. All patients exhibit chronic nonspherocytic hemolytic anemias. A negative linear correlation (r = -0.72) between mu and the number of reticulocytes was obtained in G-6-PD deficiencies. In contrast, a positive correlation (r = 0.88) was found for red blood cells of patients with PK deficiency. A mechanically induced swelling of RBC was observed for some deficient cells. The results are discussed in the framework of structural alterations of the RBC membrane due to the disturbed pentose-phosphate pathway and the diminished ATP supply through glycolysis, respectively.

Elasticity↗

New experiments on shear modulus of elasticity of arteries.

Although the mechanical properties of blood vessels have been studied extensively, the shear modulus of the blood vessel wall is still unknown. New data on the shear modulus of elasticity of rat arteries and its variation with axial stretch and blood pressure are presented. The data were obtained from a new instrument designed and constructed by us to perform simultaneous torsion, inflation, and longitudinal stretching tests. It was found under physiological conditions (pressure = 120 mmHg or 16 kPa; longitudinal stretch = 1.2 relative to zero-stress state), the shear modulus of normal rat thoracic aorta is G = 137 +/- 18 kPa. The difference of shear modulus at body temperature (37 degrees C) and room temperature (25 degrees C) is within 10%. The shear modulus varies significantly with changing longitudinal and circumferential strains in proportion to the strain energy due to these strains. A constitutive equation based on a pseudo strain energy function is proposed. The vessel wall is not transversely isotropic in the incremental sense. When the rat was subjected to high blood pressure due to constriction of its aorta, the shear modulus does not vary significantly with the length of time the animal was subjected to hypertension.

Animals↗

Stress wave velocities in bovine patellar tendon.

The velocity of longitudinal stress waves in an elastic body is given by the square root of the ratio of its elastic modulus to its density. In tendinous and ligamentous tissue, the elastic modulus increases with strain and with strain rate. Therefore, it was postulated that stress wave velocity would also increase with increasing strain and strain rate. The purpose of this study was to determine the velocity of stress waves in tendinous tissue as a function of strain and to compare these values to those predicted using the elastic modulus derived from quasi-static testing. Five bovine patellar tendons were harvested and potted as bone-tendon-bone specimens. Quasi-static mechanical properties were determined in tension at a deformation rate of 100 mm/s. Impact loading was employed to determine wave velocity at various strain levels, achieved by preloading the tendon. Following impact, there was a measurable delay in force transmission across the specimen and this delay decreased with increasing tendon strain. The wave velocities at tendon strains of 0.0075, 0.015, and 0.0225 were determined to be 260 +/- 52 m/s, 360 +/- 71 m/s, and 461 +/- 94 m/s, respectively. These velocities were significantly (p < 0.01) faster than those predicted using elastic moduli derived from the quasi-static tests by 52, 45, and 41 percent, respectively. This study has documented that stress wave velocity in patellar tendon increases with increasing strain and is underestimated with a modulus estimated from quasi-static testing.

Animals↗

Effects of stem design and material properties on stresses in hip endoprostheses.

With the aid of a three-dimensional finite element stress analysis a parameteric study of the essential aspects of the femoral component of hip endoprostheses was carried out. Various designs were investigated; these included the prosthetic stem length, the existence or non-existence of the prosthetic collar and the elastic modulus of stem and cement. Variations in the stem length have only minor effects on the stress distribution for a stem length greater than 100 mm, but the elastic modulus of the prosthetic stem has a considerable influence on the stresses. A high elastic modulus of the stem increases the stresses in the stem but it decreases stresses in the cement. The cement stresses increase with an increase in the modulus of elasticity of the cement.

Bone Cements↗

Fracture toughness of water-aged resin composite restorative materials.

OBJECTIVES: The purpose of this study was to assess the effects of aging experimental dimethacrylate resin composites in water at 37 degrees C for periods up to 6 wk by measuring the variations in fracture toughness (K(c)), elastic modulus (E), fracture energy (G(c)), and water sorption. METHODS: Six experimental resins were formulated from dimethacrylate resins, and were filled to 86 wt% (ca. 70 vol%) with treated inorganic filler to form six experimental composites. The fracture toughness was determined using a double torsion technique, the elastic modulus was measured in flexure, and the fracture energy was calculated from the fracture toughness and elastic modulus. RESULTS: As a result of aging in water, K(c) and the G(c) increased, and the elastic modulus decreased, but all values approached a plateau near 6 wk. Water sorption also occurred during this period, mainly during the first 2 wk. SIGNIFICANCE: Variations in the mechanical properties are interpreted as being due to plasticization of the resin matrix by water, which appears to lower the yield stress and increase in the size of the plastic zone ahead of the crack, thereby causing the observed increase in G(c) and K(c). After approximately 6 wk, no further changes in properties occurred.

Absorption↗

Diffusing wave spectroscopy microrheology of actin filament networks.

Filamentous actin (F-actin), one of the constituents of the cytoskeleton, is believed to be the most important participant in the motion and mechanical integrity of eukaryotic cells. Traditionally, the viscoelastic moduli of F-actin networks have been measured by imposing a small mechanical strain and quantifying the resulting stress. The magnitude of the viscoelastic moduli, their concentration dependence and strain dependence, as well as the viscoelastic nature (solid-like or liquid-like) of networks of uncross-linked F-actin, have been the subjects of debate. Although this paper helps to resolve the debate and establishes the extent of the linear regime of F-actin networks' rheology, we report novel measurements of the high-frequency behavior of networks of F-actin, using a noninvasive light-scattering based technique, diffusing wave spectroscopy (DWS). Because no external strain is applied, our optical assay generates measurements of the mechanical properties of F-actin networks that avoid many ambiguities inherent in mechanical measurements. We observe that the elastic modulus has a small magnitude, no strain dependence, and a weak concentration dependence. Therefore, F-actin alone is not sufficient to generate the elastic modulus necessary to sustain the structural rigidity of most cells or support new cellular protrusions. Unlike previous studies, our measurements show that the mechanical properties of F-actin are highly dependent on the frequency content of the deformation. We show that the loss modulus unexpectedly dominates the elastic modulus at high frequencies, which are key for fast transitions. Finally, the measured mean square displacement of the optical probes, which is also generated by DWS measurements, offers new insight into the local bending fluctuations of the individual actin filaments and shows how they generate enhanced dissipation at short time scales.

Actin Cytoskeleton↗

Effects of clonidine on aortic pressure-diameter and elastic stiffness-stress relations in anaesthetized rabbits.

1. The effects of clonidine on the aortic pressure-diameter relationship were studied in anaesthetized rabbits by means of an ultrasonic dimension technique. Midwall aortic stress and aortic elastic modulus were calculated. 2. In spite of a significant decrease in mean aortic blood pressure, aortic diameter was slightly but not significantly increased after intravenous clonidine injection (25 microgram/kg body wt., intravenously over 30 s). 3. Midwall aortic stress was decreased when compared at the same aortic radius and aortic elastic modulus was increased when compared at a common blood pressure level. However, when aortic elastic modulus was plotted as a linear function of the stress, no difference was observed before and after clonidine. 4. The results suggest that the pressure-diameter changes induced by clonidine were primarily reflecting the mechanical changes in the aortic wall due to changes in smooth muscle tension. Furthermore it seems that the elastic modulus of the aorta tends to remain constant by adaptive changes in the aortic wall which over-ride the concurrent geometrical changes to maintain a level of elasticity consistent with the degree of aortic stress.

Animals↗

Trabecular bone mineral and calculated structure of human bone specimens scanned by peripheral quantitative computed tomography: relation to biomechanical properties.

The relationship of cortical bone mineral density (BMD), and geometry to bone strength has been well documented. In this study, we used peripheral quantitative computerized tomography (pQCT) to acquire trabecular BMD and high-resolution images of trabeculae from specimens to determine their relationship with biomechanical properties. Fifty-eight human cubic trabecular bone specimens, including 26 from the vertebral bodies, were scanned in water and air. Trabecular structure was quantitated using software developed with Advanced Visual Systems interfaced on a Sun/Sparc Workstation. BMD was also obtained using a whole-body computerized tomography scanner (QCT). Nondestructive testing of the specimens was performed to assess their elastic modulus. QCT and pQCT measurements of BMD of specimens in water were strongly correlated (r2 = 0.95, p < 0.0001), with a slope (0.96) statistically not significantly different from 1. Strong correlations were found between pQCT measurements of specimens in water and in air, for BMD (r2 = 0.96, p < 0.0001), and for apparent trabecular structural parameters (r2 = 0.89-0.93, p < 0.0001). Correlations were moderate between BMD and apparent trabecular structural parameters (r2 = 0.37-0.64, p < 0.0001). Precision as coefficient of variation (CV) and standardized coefficient of variation (SCV) for these measurements was < 5%. For the vertebral specimens, the correlation was higher between elastic modulus and BMD (r2 = 0.76,p < 0.0001) than between elastic modulus and apparent trabecular structural parameters (r2 = 0.58-0.72, p < 0.0001), while the addition of apparent trabecular nodes and branches to BMD in a multivariate regression model significantly increased the correlation with the elastic modulus (r2 = 0.86, p < 0.01). Thus, pQCT can comparably and reproducibly measure trabecular bone mineral in water or air, and trabecular structure can be quantitated from pQCT images. The combination of volumetric BMD with trabecular structural parameters rather than either alone improves the prediction of biomechanical properties. Such a noninvasive approach may be useful for the preclinical study of osteoporosis.

Adult↗

Quantitative ultrasound does not reflect mechanically induced damage in human cancellous bone.

This study investigated the ability of quantitative ultrasound (QUS) to detect reductions in the elastic modulus of cancellous bone caused by mechanical damage. Ultrasonic velocity and attenuation were measured using an in-house parametric imaging system in 46 cancellous bone cores from the human calcaneus. Each core was subjected to a mechanical testing regime to (a) determine the predamage elastic modulus, (b) induce damage by applying specified strains in excess of the yield strain, and (c) measure the postdamage elastic modulus. The specimens were divided into four groups: a control group subjected to a nominally nondestructive 0.7% maximum strain (epsilonm) and three damage groups subjected to increasing strain levels (epsilonm = 1.5, 3.0, and 4.5%). QUS measurements before and after the mechanical testing showed no significant differences between the control group and damage groups, despite highly significant (p < 0.001) reductions in the elastic modulus of up to 72%. These results indicate that current QUS techniques do not intrinsically reflect the elastic properties of cancellous bone. This is consistent with ultrasonic properties being determined by other factors (apparent density and/or architecture), which normally are associated strongly with elastic properties, but only when bone is mechanically intact. Clinically, this implies that ultrasound cannot be expected to detect bone fragility in the absence of major changes in bone density and/or trabecular architecture.

Aged↗