PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Gravity, Altered”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Artificial gravity considerations for a mars exploration mission.

Artificial gravity (AG), as a means of preventing physiological deconditioning of astronauts during long-duration space flights, presents certain special challenges to the otolith organs and the adaptive capabilities of the CNS. The key issues regarding the choice of AG acceleration, radius, and rotation rate are reviewed from the viewpoints of physiological requirements and human factors disturbances. Head movements and resultant Coriolis forces on the rotating platform may limit the usefulness of economical short centrifuges for other than brief periods of intermittent stimulation.

Aerospace Medicine↗

The next small step.

Explore the source record for details and available documents.

Adaptation, Physiological↗

Effects of alveolated duct structure on aerosol kinetics. I. Diffusional deposition in the absence of gravity.

We examined the effects of alveolar duct structure on particle deposition in the pulmonary acinus. The low Reynolds number velocity field of carrier gas in a geometric model of the alveolated duct was solved numerically. Particle trajectories were computed from the Langevin equation. Conditional probabilities of the trajectories were calculated with an eigenfunction expansion technique in the absence of gravity. For submicron particles, Brownian motion dominated the process; the deposition rate dramatically decreased with boundary layer growth. For fine particles, fully developed boundary layer profiles determined the deposition over most of the acinar length. The assumption of a uniform radial profile results in a substantial overestimation of the local deposition rate. The deposition rate in an alveolated duct was always smaller than that in an equivalent straight tube of the same volume. Within the alveolus the deposition pattern was markedly nonuniform, with higher deposition near the alveolar entrance ring; this finding is consistent with experimental observations in animals (e.g., see Zeltner et al. J. Appl. Physiol. 70: 1137-1145, 1991). We conclude that the structure of the alveolar duct has an important influence on aerosol particle deposition in the lung acinus.

Aerosols↗

Differential response of macrophage subpopulations to soleus muscle reloading after rat hindlimb suspension.

The hypothesis that distinct populations of macrophages are associated with muscle necrosis and regeneration was examined in Wistar rat soleus muscle after 10 days of hindlimb suspension and 2, 4, and 7 days after the resumption of weight bearing. Necrosis was identified using histological features, such as muscle fiber infiltration, and regeneration was identified using immunohistochemical techniques for developmental myosin heavy chain (dMHC). Light-microscopic observations show that necrotic fibers in 2-day reloaded soleus muscle were invaded by ED1+ and Ia+ macrophages. The number of invaded fibers in muscles reloaded for 2 days increased to 2.8/mm2 compared with 0.2/mm2 in age-matched normal muscle but returned to control values by the 4th day of resumed weight bearing. In the interstitial spaces of 2-day recovery muscle, ED1+ and Ia+ macrophages numbered 369 and 332/mm2, respectively, compared with 12 and 72/mm2, respectively, in control soleus. After 7 days of reloading, the number of ED1+ cells was similar to that of control. Ia+ macrophages decreased to 240/mm2 at 4 days but after 7 days rose above control values to 429/mm2. ED2+ macrophages in 4- and 7-day reloaded soleus increased 70-80% in the interstitial spaces compared with control but were not observed to infiltrate necrotic muscle fibers at any time points. Immunohistochemistry and immunoblots using a monoclonal anti-dMHC antibody demonstrate a greater proportion of myofibers expressing dMHC isoforms after 4 and 7 days of reloading. These findings indicate that macrophage subpopulations are associated with distinct stages during the recovery process from hindlimb suspension: ED1+ macrophages are associated with muscle necrosis, whereas ED2+ cells are associated with muscle regeneration.(ABSTRACT TRUNCATED AT 250 WORDS)

Acid Phosphatase↗

Effects of gravity and blood volume shifts on cardiogenic oscillations in respired gas.

During the cardiac cycle, cardiogenic oscillations of expired gas (x) concentrations (COS([x])) are generated. At the same time, there are heart-synchronous cardiogenic oscillations of airway flow (COS(flow)), where inflow occurs during systole. We hypothesized that both phenomena, although primarily generated by the heartbeat, would react differently to the cephalad blood shift caused by inflation of an anti-gravity (anti-G) suit and to changes in gravity. Twelve seated subjects performed a rebreathing-breath-holding-expiration maneuver with a gas mixture containing O2 and He at normal (1 G) and moderately increased gravity (2 G); an anti-G suit was inflated to 85 mmHg in each condition. When the anti-G suit was inflated, COS(flow) amplitude increased (P = 0.0028) at 1 G to 186% of the control value without inflation (1-G control) and at 2 G to 203% of the control value without inflation (2-G control). In contrast, the amplitude of COS of the concentration of the blood-soluble gas O2 (COS([O2/He])), an index of the differences in pulmonary perfusion between lung units, declined to 75% of the 1-G control value and to 74% of the 2-G control value (P = 0.0030). There were no significant changes in COS(flow) or COS([O2/He]) amplitudes with gravity. We conclude that the heart-synchronous mechanical agitation of the lungs, as expressed by COS(flow), is highly dependent on peripheral-to-central blood shifts. In contrast, COS([blood-soluble gas]) appears relatively independent of this mechanical agitation and seems to be determined mainly by differences in intrapulmonary perfusion.

Adaptation, Physiological↗

Effect of changing the gravity vector on respiratory output and control.

We studied the respiratory output in five subjects exposed to parabolic flights [gravity vector 1, 1.8 and 0 gravity vector in the craniocaudal direction (Gz)] and when switching from sitting to supine (legs bent at the knees). Despite differences in total respiratory compliance (highest at 0 Gz and in supine and minimum at 1.8 Gz), no significant changes in elastic inspiratory work were observed in the various conditions, except when comparing 1.8 Gz with 1 Gz (subjects were in the seated position in all circumstances), although the elastic work had an inverse relationship with total respiratory compliance that was highest at 0 Gz and in supine posture and minimum at 1.8 Gz. Relative to 1 Gz, lung resistance (airways plus lung tissue) increased significantly by 52% in the supine but slightly decreased at 0 Gz. We calculated, for each condition, the tidal volume changes based on the energy available in the preceding phase and concluded that an increase in inspiratory muscle output occurs when respiratory load increases (e.g., going from 0 to 1.8 Gz), whereas a decrease occurs in the opposite case (e.g., from 1.8 to 0 Gz). Despite these immediate changes, ventilation increased, going to 1.8 and 0 Gz (up to approximately 23%), reflecting an increase in mean inspiratory flow rate, tidal volume, and respiratory frequency, while ventilation decreased (approximately -14%), shifting to supine posture (transition time approximately 15 s). These data suggest a remarkable feature in the mechanical arrangement of the respiratory system such that it can maintain the ventilatory output with small changes in inspiratory muscle work in face of considerable changes in configuration and mechanical properties.

Acceleration↗

Circulatory galanin levels increase severalfold with intense orthostatic challenge in healthy humans.

The purpose of this study was to test the hypothesis that plasma galanin concentration (pGal) is regularly increased in healthy humans with extensive orthostatic stress. Twenty-six test persons (14 men, 12 women) were brought to an orthostatic end point via a progressive cardiovascular stress (PCS) protocol consisting of 70 degrees head-up tilt plus increasing levels of lower body negative pressure until either hemodynamically defined presyncope or other signs of orthostatic intolerance occurred (nausea, clammy skin, excessive sweating, pallor of the skin). We further tested for possible gender, gravitational, and muscular training influences on plasma pGal responses: PCS was applied before and after 3 wk of daily vertical acceleration exposure training on a Human Powered Centrifuge. Test persons were randomly assigned to active (with bicycle work) or passive (without work) groups (seven men, six women in each group). Resting pGal was 26+/-3 pg/ml in men and 39+/-15 pg/ml in women (not significant); women had higher galanin responses (4.9-fold increase) than men (3.5-fold, P=0.017) to PCS exposure. Overall, PCS increased pGal to 186+/-5 pg/ml (P=0.0003), without significant differences between presyncope vs. orthostatic intolerance, pre- vs. postcentrifuge, or active vs. passive gravitational training. Increases in pGal were poorly related to synchronous elevations in plasma vasopressin. We conclude that galanin is regularly increased in healthy humans under conditions of presyncopal orthostatic stress, the response being independent of gravity training but larger in women than in men.

Adult↗

Gravitoinertial force background level affects adaptation to coriolis force perturbations of reaching movements.

We evaluated the combined effects on reaching movements of the transient, movement-dependent Coriolis forces and the static centrifugal forces generated in a rotating environment. Specifically, we assessed the effects of comparable Coriolis force perturbations in different static force backgrounds. Two groups of subjects made reaching movements toward a just-extinguished visual target before rotation began, during 10 rpm counterclockwise rotation, and after rotation ceased. One group was seated on the axis of rotation, the other 2.23 m away. The resultant of gravity and centrifugal force on the hand was 1.0 g for the on-center group during 10 rpm rotation, and 1.031 g for the off-center group because of the 0.25 g centrifugal force present. For both groups, rightward Coriolis forces, approximately 0.2 g peak, were generated during voluntary arm movements. The endpoints and paths of the initial per-rotation movements were deviated rightward for both groups by comparable amounts. Within 10 subsequent reaches, the on-center group regained baseline accuracy and straight-line paths; however, even after 40 movements the off-center group had not resumed baseline endpoint accuracy. Mirror-image aftereffects occurred when rotation stopped. These findings demonstrate that manual control is disrupted by transient Coriolis force perturbations and that adaptation can occur even in the absence of visual feedback. An increase, even a small one, in background force level above normal gravity does not affect the size of the reaching errors induced by Coriolis forces nor does it affect the rate of reacquiring straight reaching paths; however, it does hinder restoration of reaching accuracy.

Adaptation, Physiological↗

Effect of G-force on bicuspid aortic valve in aviators.

BACKGROUND AND AIMS: Bicuspid aortic valve (BAV) is a common congenital cardiac malformation. The major complications are aortic stenosis (AS), aortic regurgitation (AR), infectious endocarditis and aortic dissection. This paper aims to assess the hemodynamic importance of incidentally-found BAV in military aviators and evaluate the effect of high G-force on disease progression. METHODS: Aviators with BAV were detected by reviewing all cardiac assessment records between 1987 and 2005. All aviators underwent annual flight surgeon examination. Echocardiography was performed as recommended by our cardiologists and flight surgeons. RESULTS: Eight newly diagnosed cases of BAV were found. All of the aviators continued active aviation throughout the study period. Repeat echocardiography demonstrated progressive widening of the aortic diameter in five of the eight aviators. No worsening of valve dysfunction was seen in those with mild aortic regurgitation at diagnosis. Left ventricular dimensions and function did not deteriorate. No new valve complications, including infectious endocarditis, were seen. The age at diagnosis strongly correlated with the root diameter change; both total (r = 0.74, p = 0.02) and annualized (r = 0.78, p = 0.02) change. Over a mean follow-up period of 12.1 years, no difference was seen in the progression of BAV in high-performance as compared to low-performance aviators. CONCLUSIONS: Exposure to G-force and anti-G maneuvers does not appear to worsen cardiac and valve function in aviators with BAV.

Adolescent↗

Bone cell survival in microgravity: evidence that modeled microgravity increases osteoblast sensitivity to apoptogens.

Studies were performed to evaluate the effects of modeled microgravity on the induction of osteoblast apoptosis. MC3T3-E1 osteoblast-like cells were cultured in alginate carriers in the NASA-approved high aspect ratio vessel (HARV). This system subjects the cells to a time-averaged gravitational field (vector-averaged gravity) to simulate low gravity conditions. Cells were cultured in the HARV for five days, and then examined for apoptosis. In simulated microgravity, the cells remained vital, although analysis of expressed genes indicated that there was loss of the mature osteoblast phenotype. Additionally, we noted that there was a loss of the mitochondrial membrane potential, a low level of the antiapoptotic protein Bcl-2, as well as Akt protein, and the redox status of the cells was disturbed. All of these parameters indicated that vector-averaged gravity disrupts mitochondrial function, thereby sensitizing osteoblasts to apoptosis. We then used a challenge assay to evaluate the apoptotic sensitivity of the cells subjected to vector-averaged gravity. When challenged with staurosporine, cells subjected to vector-averaged gravity evidenced elevated levels of cell death relative to control cell populations. Another objective of the study was to improve upon conventional carriers by using alginate encapsulation to support cells in the HARV. We have demonstrated that the alginate carrier system affords a more robust system than surface-seeded carriers. This new system has the advantage of shielding cells from mechanical damage and fluid shear stresses on cells in the HARV, permitting carefully controlled studies of the effects of vector-averaged gravity.

3T3 Cells↗

The measurement of solute diffusion coefficients in dilute liquid alloys: the influence of unit gravity and g-jitter on buoyancy convection.

Liquid diffusion experiments conducted on the MIR space station using the Canadian Space Agency QUELD II processing facility and the microgravity isolation mount (MIM) showed that g-jitter significantly increased the measured solute diffusion coefficients. In some experiments, milli-g forced vibration was superimposed on the sample when isolated from the ambient g-jitter; this resulted in markedly increased solute transport. To further explore the effects arising in these long capillary diffusion couples from the absence of unit-gravity and the presence of the forced g-jitter, the effects of a 1 milli-g forcing vibration on the mass transport in a 1.5 mm diameter long capillary diffusion couple have been simulated. In addition, to increase understanding of the role of unit gravity in determining the extent to which gravity can influence measured diffusion coefficient values, comparative experiments involving gold, silver, and antimony diffusing in liquid lead have been carried out using a similar QUELD II facility to that employed in the QUELD II/MIM/MIR campaign but under terrestrial conditions. It was found that buoyancy-driven convection may still persist in the liquid even when conditions are arranged for a continuously decreasing density gradient up the axis of a vertical long capillary diffusion couple due to the presence of small radial temperature gradients.

Acceleration↗

Meiotic progression of isolated mouse spermatocytes under simulated microgravity.

Progression through the prophase of the first meiotic division can be obtained in culture by treatment of mouse spermatocytes with the serine/threonine phosphatase inhibitor okadaic acid. Chromosome condensation during this G2/M transition involves the activation of the MAPK pathway, which causes the activation of Nek2 and the phosphorylation of the chromatin architectural protein Hmga2. In an effort to set up conditions to allow a spontaneous progression of mouse spermatocytes through meiosis, we have investigated the cell-cycle features of these cells cultured for 24 h with a rotary cell culture system in a humidified atmosphere in a thermostatic incubator to simulate a microgravity environment. Morphological analysis of nuclear squashes indicated a 2-fold increase in late-pachytene spermatocytes with highly condensed chromosomes, and a contemporaneous decrease of mid-pachytene cells with less condensed chromatin. Microgravity induced a 2-fold activation of the cyclinB-cdc2 complex, confirming at the molecular level that cell-cycle progression had occurred. Moreover, using immuno-kinase assays with specific substrates we have demonstrated that the meiotic progression obtained under microgravity conditions is accompanied by activation of the Erk1/p90Rsk2 pathway. These data indicated that activation of the MAPK pathway correlates with chromatin condensation even under conditions in which meiotic progression occurs spontaneously and is not induced by a drug. We suggest that culture under microgravity conditions might help to release the block that inhibits isolated spermatocytes from progressing through prophase at unit gravity, and to study the physiological events of germ cell differentiation in vitro.

Animals↗

Development of centrifugal phytotron to study the gravity effect on vegetable plant growth.

The present Spacetron is used to cultivate plants over a long term by controlling environment condition. The cultivation drum was rotated in perpendicular direction creating fluctuation in gravity. Centrifugal force plus 1 G ground gravity, are distributed unevenly over the cultivation drum. This fluctuation effect on plant growth was not clear. In the modified Spacetron the cultivation drum rotates horizontally whereas the plant stage rotated in the perpendicular direction. To find the basic information for design of centrifugal phytotron the two axes Spacetron Junior (clinostat) was developed to formulate the micro and hypergravity environment. It would be used to study the effect on a plant growth process of different gravity conditions. In order to produce the different values of gravity, the clinostat's axis was rotated with a stepping motor at different angular velocity. The axis rotated at 5.2 revolutions per minute (rpm) to create a centrifugal force equivalent to 0.01 G and the plant stage was rotated at 5.2 rpm. The chlorophyll value is higher in the plants under microgravity condition of 0.01 G whereas the fresh weight and dry weight are higher in the plants under control condition of 1 G earth gravity. The result of this study showed that the plant growth was affected by microgravity along with other known factors such as vibration and unknown factors.

Biomass↗

Physiological tremor under pseudo-fraction gravity.

The effect of pseudo-fraction gravity on physiological tremor of the human finger (finger tremor) has been examined experimentally by immersing an index finger into water at different immersion levels. The pseudo-fraction gravity, gamma G, was established by water buoyancy at immersion level omega, G being gravitation acceleration and gamma between zero and unit. The nature of variations of finger tremor under the influence of gamma G is estimated based on FFT spectral analysis. It is illustrated that with a decrease in gamma, or equivalently an increase in omega, two dominant peaks remaining approximately constant in frequencies around 10Hz and 20Hz are found, while peak amplitude is decreased rapidly for higher peak and slowly for lower one. Theoretically the effect of pseudo-fraction gravity is analyzed in terms of a specific model for finger tremor. The experimental results presented in this paper are predicted rather well by two resonant modes which occurred in our model system. It is possible to conclude that the model, which is characterized by a pair of antagonistic muscles and two reflex pathways, provides an adequate quantitative description of finger tremor.

Adult↗

[Aquatic animals and use of centrifuge in space experiments].

There are some experiments which do not need a centrifuge apparatus in space, however, for other space experiments the use of centrifuge is indispensable as the control. The characteristics of these two types of space experiments are explained. Generally, the more quantitatively the phenomenon is analyzed, the greater the need of centrifuge apparatus becomes. The centrifuge in space can realize various gravity values ranging from 0 to 1 G, and this will extend the present biology to a more universal biology.

Animals↗