PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Mandibular Prosthesis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Primary malignant fibrous histiocytoma of the mandible: surgical approach and report of a case.

A case of histologically proven malignant fibrous histiocytoma (MFH) of the mandible is presented. This tumor rarely occurs as a primary neoplasm of the mandible. An intraoral block resection of the mandible, including adjacent clinically normal soft tissue was performed. To maintain the soft tissue bed and esthetics, and to preserve mandibular function, immediate reconstruction was carried out with methyl methacrylate, the anatomical configuration of which was derived from the resected specimen.

Female↗

CT evaluation of TMJ disc replacement with a Proplast-Teflon laminate.

A series of 12 temporomandibular joints treated by discectomy and replacement with Proplast nonporous Teflon laminates were examined retrospectively using direct sagittal and coronal computed tomography. Radiographic findings included severe condylar, glenoid fossa, and eminence remodeling changes; implant migration and fragmentation; and loss of implant adaptation to the temporal bone. The radiographic changes generally occurred in patients who were completely asymptomatic clinically.

Adult↗

Functional alveolar reconstruction in a patient with total mandibular replacement.

Alveolar reconstruction in a case of total mandibular replacement is presented. The placement of hydroxylapatite bone substitute and the staple bone plate into a previously grafted area demonstrates that the properties of transplanted bone are similar to natural bone. Furthermore, the safety and effectiveness of the utilization of these biomaterials in areas of previous osseous reconstruction is documented. An awareness of biologic tissue response may have also contributed to successful functional restoration. In addition, a major question about the functions of the muscles of mastication arises.

Adult↗

Tomographic evaluation of temporomandibular joints following discoplasty or placement of polytetrafluoroethylene implants.

A retrospective comparison was made of tomographic change in the temporomandibular joint (TMJ) of patients who had been treated by either discoplasty or discectomy with polytetrafluoroethylene (PTFE) disc replacement. Fifty-five PTFE- and 18 discoplasty-treated joints were evaluated. More than 60% of the PTFE-treated joints showed severe, destructive osseous change, whereas none of the discoplasty joints showed such change. Histologic examination of the tissues surrounding removed PTFE implants showed a foreign body giant cell reaction. The severity of radiographic change raises questions about the propriety of PTFE as a disc replacement material.

Adolescent↗

Analysis of reconstruction for anterior mandibular defects using AO plates.

The functional and cosmetic outcome of 11 patients who had anterior arch mandibulectomy for stage II-IV oral cavity carcinoma and were reconstructed with AO stainless-steel or titanium plates was retrospectively analyzed. Although the complication rate was high, plate removal was uncommon. Patients were afforded good function and cosmesis. Severity of postoperative infection corresponded to a low preoperative absolute lymphocyte count, which suggests that increased preoperative diet supplementation may decrease the incidence of early infections. Improved mandibular function and esthetics may allow future patients to be offered early reconstruction routinely.

Adult↗

Critical analysis of mandibular reconstruction using AO reconstruction plates.

Forty-one cases (37 patients) of mandibular reconstruction using AO plates were reviewed. The patients' ages ranged from 27 to 83 years (mean, 52.3 +/- 18.1 years) and their cases were followed for 6 to 42 months (mean, 12.7 +/- 8.3 months). Cases were grouped by the location of reconstruction: anterior mandible crossing midline as group A (12 cases), body segment of the mandible as group B (16 cases), condyle and ramus of the mandible as group C (13 cases). The incidence of revision as a measure of outcome was calculated by actuarial methods accounting for loss to follow-up or death. Revision or plate removal occurred in 22.2% (9 of 41 cases), with an incidence of 52.2% (6 of 12 cases) in group A, 12.5% (2 of 16 cases) in group B, and 7.7% (1 of 13 cases) in group C. Combined use of an AO plate and bone graft had a revision rate of 33.3% (4 of 12 cases), whereas the reconstructions with only a plate had a revision rate of 17.2% (5 of 29 cases). The difference between the immediate reconstructions (19.2%; 5 of 26 cases) and delayed reconstructions (26.7%; 4 of 15 cases) was not significant, but delayed reconstruction of the anterior mandible resulted in the highest failure rate (57.1%; 4 of 7 cases). The revision incidence was significantly higher when the area had been radiated (33.3% of 24 radiated cases and 5.7% of nonradiated cases required revision). In particular, the radiated group A had a remarkably higher failure rate (63.2% of 10 cases).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Rigid reconstruction plates for immediate reconstruction following mandibular resection for malignant tumors.

Thirty-four primary alloplastic reconstructions of segmental mandibular defects caused by surgery for oral malignancy were performed during a 6-year period. Eighty-eight percent of the tumors were classified as stage III or IV. One third of the patients died during follow-up, nine with their primary reconstruction plate in place. During the follow-up, 12 patients required plate removal because of complications; four of them were treated with another plate. Nineteen of 21 patients alive at the end of follow-up were free of disease. Ten had their primary plate in place, and four had had a secondary plate installed because of plate fracture or screw loosening. Three patients had their mandible permanently reconstructed with bone. The functional and esthetic results were considered excellent or fair in a majority of the cases. Because the 5-year survival rate for patients with advanced mandibular malignancies is 15% to 20%, extensive, definitive reconstructive procedures during primary surgery are usually not justified.

Adult↗

Oral and maxillofacial reconstruction.

Advances in surgical technique and dental implant technology have benefitted both patients and practitioners alike. Earlier diagnosis and treatment, along with increased survival, has made it incumbent on the dental professional to be aware of what can be done for the formerly unrestorable patient. This cooperative team approach works to everyone's advantage.

Bone Plates↗

Mandibular reconstruction with the Dacron urethane tray: a radiologic assessment of bone remodeling.

A retrospective study was made of 22 consecutive patients who underwent mandibular reconstruction with a Dacron (Osteo-mesh, Xomed Inc, Jacksonville, FL) tray technique from September 1988 to April 1992. Free autogenous iliac bone, in the form of particulate cancellous chips and marrow, was densely packed into the Dacron tray, that was adapted to bridge the mandibular segmental defect. Sixteen cases underwent uneventful healing with the formation of a continuous bony bridge and union with the remaining mandible. The pattern of bone remodeling and rate of resorption in these cases were assessed by sequential panoramic radiographs taken up to 3 years postoperatively. The mean horizontal dimension of the mandibular defects was 75 mm and the mean vertical reconstructed height was 25 mm. When the grafted bone was radiographically of uniform density, it progressed into a mature trabecular pattern matching that of the normal mandible. However, when there were areas of radiolucency, most likely from inadequate condensation of the graft, such areas were not replaced by bone in the long term. The bony height at both ends and the middle of the reconstructed segment underwent reasonably even resorption and retained about 80% of the bony height over a 3-year period. The rate of resorption was highest in the first 6 months and stabilized at about 2 years. There were six failures, all showing significant irregular bony resorption prior to tray removal.

Adolescent↗

Long term results of reconstruction plates in lateral mandibular defects. Revision of nine cases.

OBJECTIVE: Although microsurgical bone transplant is still the gold standard, mandibular reconstruction plates (MRP) were for several years considered a fast and safe way to restore mandibular continuity without using a bone graft. New plate designs with locking screws have been recently introduced, and these may overcome some of the complications related to previous designs. We review the results of mandibular reconstruction plates in our institution from 1991 to 1995. METHODS: The records of nine cancer patients who underwent lateral mandibular resections (with preservation of both condyle and symphysis) followed by reconstruction with a mandibular reconstruction plate, were retrospectively reviewed. Patients were treated between 1991 and 1995 with regular Synthes and Leibinger plates (without locking screws). Immediately after tumour resection, the bone defect was reconstructed with an MRP without bone grafting. Three cases required soft tissue coverage: two flaps and one buccal fat pad flap. RESULTS: There was immediate orocervical fistula in six cases, one of which required surgical closure; and late complications were common. One patient died due to distant metastasis 13 months after surgery without symptoms related to the plate. The remaining eight patients had their plates removed at between 9 and 52 months after reconstruction, due to screw loosening (four cases), plate exposure (one case), or both (three cases). CONCLUSION: Lateral mandibular reconstruction with non-locking screws and regular profile plates is no longer recommended. New plates with improved designs are currently available. Their low profile and locking screws are the usual characteristics of these new plates. More clinical experience is necessary before plate reconstruction can be recommended over microvascular bone transfer.

Aged↗