PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymethacrylic Acids”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

pH-independent controlled-release microspheres using polyglycerol esters of fatty acids.

The release of a drug having low solubility in a certain pH range from controlled-release microspheres using tetraglycerol pentastearate and tetraglycerol monostearate in combination as the matrix base showed pH dependence. Trepibutone, an acidic drug having lower solubility in an acidic medium, was released pH-independently from the microspheres which incorporated magnesium oxide, a solid base. It might have resulted from the pH inside the matrix being kept in an optimum range for drug release due to the incorporation of a solid base. On the other hand, the addition of water soluble acidic or basic excipients was ineffective to achieve pH-independent release. For papaverine, a basic drug, pH-independent drug-release characteristics could be achieved by adding Eudragit L100-55, an enteric polymer. It is thought that the enteric polymer increased the pores for drug release by dissolving in a higher pH range, where the solubility of papaverine is low, and thereby made the release pH-independent. Further, selecting a polyglycerol ester of a fatty acid with an appropriate hydrophile-lipophile balance as the matrix could yield a drug with the desired release rate at any pH.

Acrylic Resins↗

Retention of composite inlays in enamel dentin cavities.

The retention of composite inlays depends on acid-etching of marginal enamel of the preparation. In many cases, only little marginal enamel is available, making loss of retention a liability. The present study evaluated the retention of three brands of composite inlays under various conditions. Inlays were fabricated and cemented in standardized enamel/dentin cavities prepared in extracted human teeth. The force necessary to extract a cemented inlay was used to express the retention of the inlay. The effects of thermocycling and choice of dentin-bonding agent on inlay retention were also determined. Inlays made of Estilux posterior C VS were more retentive than inlays of either Brilliant or SR-Isosit. The latter two products were found to provide similar retentive strengths. The retention of Estilux posterior C VS and SR-Isosit inlays declined when samples were thermocycled. Treatment with Gluma increased retention of inlays, resulting in retentive strengths of the same magnitude for all three inlay systems. The choice of dentin-bonding agent was found to affect composite inlay retention to a greater extent than the choice of either composite brand, mode of inlay curing, or effect of thermocycling.

Acid Etching, Dental↗

13C NMR analysis of the etching efficacy of acidic monomers in self-etching primers.

It is well understood that the application of a self-etching primer enhances the bonding of the resin to the tooth. In this study, the demineralisation aspects by the Mega Bond Primer (MB) or the UniFil Bond Primer (UB) on the tooth were investigated by using liquid-state and solid-state 13C NMR techniques. The addition of hydroxyapatite or dentine to MB and the addition of dentine to UB resulted in the decrease in the peak intensity of the 13C NMR peaks attributed to the methacryloxy decyl phosphoric acid, MDP in the MB or 4-methacryloyloxy ethoxy carbonylphthalic acid, 4-MET in the UB. This decrease was because the MDP or 4-MET demineralised the tooth and the calcium salts produced from the MDP or 4-MET were precipitated from the MB or UB solution. The NMR technique is very powerful in evaluating the demineralisation aspects of the tooth by a self-etching primer. However, the calcium salts produced by the MDP or 4-MET on the tooth surface would not facilitate retention in bonding, since these calcium salts were merely deposited on to the surface of the tooth.

Acid Etching, Dental↗

Production of chitosan pellets by extrusion/spheronization.

Chitosan pellets were successfully prepared using the extrusion/spheronization technology. Microcrystalline cellulose was used as additive in concentrations from 70 to 0%. The powder mixtures were extruded using water and diluted acetic acid solution in different powder to liquid ratios. The effects on bead formation using water and different acetic acid concentrations and solution quantities were analysed. Also, the morphological and mechanical characteristics of the obtained beads were investigated. With demineralized water as granulation fluid, pellets with a maximum of 50% (m/m) of chitosan could be produced. The mass fraction of chitosan within the pellets could be increased to 100% by using diluted acetic acid for the granulation step.

Acetic Acid↗

[Studies on heart-protecting musk pH-dependent gradient-release pellets].

AIM: To prepare heart-protecting musk pH-dependent gradient-release pellets and investigate the drug release in vitro and in vivo. METHODS: The pH-dependent gradient-release pellet system was prepared by using HPMC, Eudragit L-30D-55 and Eudragit L100-Eudragit S100 (1:5) combinations as coater. The release of borneol and total ginsenoside from pH-dependent gradient-release pellets were determined according to the method of Pharmacopoeia of the People's Republic of China (2000) in the simulated gastrointestinal pH conditions. The gastrointestinal transit and disintegration of pellets was investigated by using gamma-scintigraphic trace in volunteers. The pharmacokinetics of borneol of heart-protecting musk pH-dependent gradient-release pellets was studied in 6 healthy volunteers by GC methods. RESULTS: The f2 value of release data of borneol and total ginsenoside of the heart-protecting musk pH-dependent gradient-release pellets was 79.6 in the simulated gastrointestinal pH conditions. The gamma-scintigraphic trace evaluation demonstrated that the pellets coated with HPMC, Eudragit L-30D-55 or Eudragit L100-Eudragit S100 (1:5) combinations can disintegrate in stomach, duodenum and jejunum or ileum. The gastrointestinal transit time of pellets was about 5 hours in fasted state and about 6 hours in fed state. The concentration-time curves of borneol of heart-protecting musk pills fit in two-compartment model. The pharmacokinetics data showed that borneol had a short time of absorption and elimination. The mean residence time (MRT) of borneol of heart-protecting musk pills was 2.61 hours. The plasma concentration of borneol of heart-protecting musk sustained-release capsule which consisted of three kinds of pellets coated with HPMC, Eudragit L-30D-55 or Eudragit L100-Eudragit S100 (1:5) combinations was steadier than those of heart-protecting musk pills, its Cmax was lower than and Tmax was near to those of heart-protecting musk pills, its MRT was 4.0 hours, and its relative bioavailability was 96%. CONCLUSION: The lipidsoluble borneol and watersoluble total ginsenoside of heart-protecting musk pH-dependent gradient-release pellets can release simultaneously while sustained-releasing in vitro. The heart-protecting musk pH-dependent gradient-release pellets had the characteristics of pH-dependent gradient-releasing and disintegration while transiting in gastrointestinal tract. A characteristic of gradient sustained-release was shown in the concentration-time curves of borneol of heart-protecting musk sustained-release capsule in volunteers.

Adult↗

Moist versus dry dentin: its effect on shear bond strength.

This study compared the shear bond strengths of dentin bonding systems applied to air dried and blot (moist) dried dentin. Five systems with primers possessing hydrophilic properties were evaluated. Three contained acetone. All Bond, Amalgambond, Mirage Bond and Tenure all produced significant statistical improvement in shear bond strength values when applied to moistened dentin. Mirage Bond values quadrupled. Bond strength values with Gluma were compromised by the presence of moisture. It was concluded that acetone probably facilitated deeper and more complete penetration of resin into dentin to enhance micro-mechanical retention. Amalgambond, while free of acetone is strongly hydrophilic and is known to form substantial mechanical bonding through the formation of a resin rich superficial layer of dentin (hybridization). Gluma while hydrophilic does not appear to possess the same behavioral characteristics embodied in the other systems as evidenced from lack of a bond to moist dentin.

Acetone↗

Degradation of single bottle type self-etching primer effectuated by the primer's storage period.

PURPOSE: To examine the hydrolytic stability of the functional methacrylate monomer utilized in single bottle type self-etching primers, by using the 13C nuclear magnetic resonance (NMR) technique in order to understand why the bond strength of resin to the dentin decreased, when the primer's storage duration was prolonged. METHODS: After deuterium oxide was added to the Mega Bond Primer (MB), or Unifil Bond Primer (UB), the MB or UB solutions were then stored at 37 degrees C for 0, 3, and 10 weeks, respectively. At the end of the storage periods, 13C NMR observations of the MB or UB solution were performed at 25 degrees C by using an EX-270 spectrometer. RESULTS: The acidic and/or hydrophilic methacrylate monomer utilized in single bottle type self-etching primers became altered during the primer's storage period. Alteration of the functional monomer was possible since the acidic monomer, utilized in the self-etching primer, could supply sufficient amounts of hydronium ions, which were the result of the dissociation of the acidic group in the acidic monomer. The degradation of the primer, caused by the alteration of the functional monomer, would result in the degradation of the etching and/or priming efficacy on the tooth. The bond strength, as a result, would become decreased as the storage period was prolonged.

Acid Etching, Dental↗

Bonding of restorative materials to dentine.

The potential advantages of bonding a filling material to dentine have long been recognized by the dental profession. Such bonding would prevent recurrent decay and would provide a long-lasting restoration. Bonding of suitable filling materials to enamel can be easily accomplished by first etching the enamel with acid. This opens up areas in the enamel and permits filling materials to flow into the openings and form mechanical locks. It is not possible to do this with dentine since the acid used to etch enamel would harm the pulp when applied to dentine. The present status of dentine bonding is that a small number of products are now being marketed with claims of bonding to dentine. In addition, research is being conducted on some experimental products. Results in the laboratory show that the bond strengths achieved by composite resins, using the commercially available materials on dentine, do not reach those obtained with acid etched enamel. The correlation of these results with clinical performance is unknown. Therefore, the amount of available information is at present insufficient to make recommendations on the effectiveness or ineffectiveness of commercially available dentine bonding systems. However, it appears that caution should be employed when using any product requiring an etchant or acidic cleansing agent. There is a need for further research to gain better understanding of the biological safety and effectiveness of both the present commercial and experimental dentine bonding systems.

Acid Etching, Dental↗

Leakage of enteric (Eudragit L)-coated dosage forms in simulated gastric juice in the presence of poly(ethylene glycol).

Poly(methacrylic acid) (PMAA) and related copolymers strongly interact with poly(ethylene glycol) (PEG) in acidic fluids. Due to the in vitro experiments presented in this paper, there is a clear indication for a drug-drug interaction in vivo between PEG solutions, e.g., commercially available laxatives, and dosage forms with PMAA-based enteric-coatings (Eudragit L). In these studies, enteric-coated tablets did not fulfil the pharmacopoeias' criteria of the disintegration test if PEGs were present in the simulated gastric juice. Drug substances which are known to be unstable in acidic media or which can cause gastric irritation were released from their enteric-coated dosage forms in acidic PEG media (pH 1). Various drug dosage forms, single and multiple unit systems, were tested. They show higher and faster drug release in the presence of PEG. To get insight into the mechanism of the interaction, experiments and theoretical calculations were performed which reveal that PEGs with high molecular weight show stronger interactions with PMAA coatings indicating a contribution of hydrophobic interactions to the occurring intermolecular forces. Hydrogen bonds can be build between each monomeric unit of PEG and the acidic sequences of the copolymer.

Calorimetry, Differential Scanning↗

On the role of methacrylic acid copolymers in the intracellular delivery of antisense oligonucleotides.

The delivery of active biomacromolecules to the cytoplasm is a major challenge as it is generally hindered by the endosomal/lysosomal barrier. Synthetic titratable polyanions can overcome this barrier by destabilizing membrane bilayers at pH values typically found in endosomes. This study investigates how anionic polyelectrolytes can enhance the cytoplasmic delivery of an antisense oligonucleotide (ODN). Novel methacrylic acid (MAA) copolymers were examined for their pH-sensitive properties and ability to destabilize cell membranes in a pH-dependent manner. Ternary complex formulations prepared with the ODN, a cationic lipid and a MAA copolymer were systematically characterized with respect to their size, zeta potential, antisense activity, cytotoxicity and cellular uptake using the A549 human lung carcinoma cell line. The MAA copolymer substantially increased the activity of the antisense ODN in inhibiting the expression of protein kinase C-alpha. Uptake, cytotoxicity and antisense activity were strongly dependent on copolymer concentration. Metabolic inhibitors demonstrated that endocytosis was the major internalization pathway of the complexes, and that endosomal acidification was essential for ODN activity. Confocal microscopy analysis of cells incubated with fluorescently-labeled complexes revealed selective delivery of the ODN, but not of the copolymer, to the cytoplasm/nucleus. This study provides new insight into the mechanisms of intracellular delivery of macromolecular drugs, using synthetic anionic polyelectrolytes.

Active Transport, Cell Nucleus↗

Fissure sealants.

Explore the source record for details and available documents.

Acid Etching, Dental↗

Heterogeneous PHPMA hydrogels for tissue repair and axonal regeneration in the injured spinal cord.

A biocompatible heterogeneous hydrogel of poly[N-(2-hydroxypropyl) methacrylamide] (PHPMA) showing an open porous structure, viscoelastic properties similar to the neural tissue and a large surface area available for cell interaction, was evaluated for its ability to promote tissue repair and axonal regeneration in the transected rat spinal cord. After implantation, the polymer hydrogel could correctly bridge the tissue defect, from a permissive interface with the host tissue to favour cell ingrowth, angiogenesis and axonal growth occurred within the microstructure of the network. Within 3 months the polymer implant was invaded by host derived tissue, glial cells, blood vessels and axons penetrated the hydrogel implant. Such polymer hydrogel matrices which show neuroinductive and neuroconductive properties have the potential to repair tissue defects in the central nervous system by promoting the formation of a tissue matrix and axonal growth by replacing the lost of tissue.

Animals↗

Influence of carboxylic anhydrides on selected mechanical properties of heat-cured resin composites.

Resin composites are still in need of improved abrasion resistance for them to be ideal restorative materials for use in large occlusal cavities. The present study proposes a concept for additional cross-linking of dental monomers, by which mechanical properties and possibly the resistance to abrasion of the resin composites are increased. Cyclic acid anhydrides were added as cross-linking agents to different monomer mixtures, which were then loaded with filler. The monomer mixtures were varied with respect to type and ratio of monomer and anhydride. For measurement of diametral tensile strength, flexural strength, modulus of elasticity, and modulus of resilience, specimens were initially cured by light and then post-cured for one h at 150 degrees C. Resin composites based on UEDMA and HEMA were found to be superior to BISGMA- and TEGDMA-based composites. Increases in mechanical properties were highest when unsaturated anhydrides were used. An optimal effect of anhydride addition was found in resin composites also containing methacrylamide. Such materials resulted in a 20% increase in the mechanical properties investigated.

Acrylamides↗

Microtensile bond strengths of one-step and self-etching adhesive systems.

The microtensile bond strength of resin composite bonded to human enamel was evaluated utilizing four light-cure bonding agents. Human third molars were embedded in auto-cure acrylic and the buccal surfaces were sequentially abraded to 400 grit. Resin composite cylinders were then bonded using the four bonding systems according to the manufacturer's specifications. Each bonded tooth produced three to four longitudinal sections which were then laterally notched to give a square bond area (approximately 2.25 mm2). Specimens (n=10) were assigned to two groups: Group I was stored in distilled water at 37 degrees +/- 2 degrees C for seven days. Group II was stored in distilled water at 37 degrees +/- 2 degrees C for seven days, during which time it was thermocycled in hot and cold water baths for 1,000 cycles. In addition, a water sorption test was performed on three of the four adhesive systems. The microtensile bond strength of the conventional adhesive Optibond Solo Plus was significantly greater than that of the self-etching adhesives Tyrian SPE and Prompt L-Pop. Adhesive systems that were more hydrophilic tended to show lower bond strengths, especially after thermocycling.

Absorption↗

The effect of dentin primer on the shear bond strength between composite resin and enamel.

The purpose of this study was to determine the effect of accidental dentin primer contact with etched enamel on shear bond strength of composite resin to enamel. Four dentin bonding systems were included in this study: GLUMA Dentin Bond, Scotchbond, and Prisma Universal Bond 2 and 3. Eighty extracted human permanent anterior teeth were used and divided in eight test groups. The vestibular surfaces were ground and acid etched. For each dentin bonding system 10 samples were treated with dentin primer prior to placement of resin. Shear bond testing showed that enamel contact with dentin primer in the above two systems decreased the shear bond strength between composite and enamel by 31 to 44%.

Acid Etching, Dental↗

Studies on dressings for mucosa of the oral cavity. Part 3: Effect of preparation technology on the physical and chemical properties of stomatological xerogel dressings.

Adhesion of xerogel dressings prepared on Eudragit (E), methylcellulose (MC) and glycerol compositions, remaining within the range of 625-650 g, after addition polyvinylpyrolidone (PVP) amounts to 450-1250 g. Dissolution time from xerogel dressings without PVP additive both in water and in an artificial gastric juice amounts to 3 h. Addition of PVP results in reduction of the elution rate. In dependence upon the PVP/E/MC ratio elution time amounts to 3-3.5 h. Pharmaceutical availability of the Kunitz protease inhibitor in particular groups of then dressings depends upon concentration of hydrophilizing agent. The semi-liberation times amounts to 3.65-17.50 h.

Acrylic Resins↗