PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Respiratory Protective Devices”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Respiratory symptoms and ventilatory function of the bakery workers in Ibadan, Nigeria.

A total of five hundred Bakery workers were studied to assess occupational induced lung impairment as a result of exposure to grain and flour dust. Occupational related symptoms were recorded using structured questionnaire. Age and sex matched controls consisting of 500 University College Hospital (UCH) Ibadan workers and students were used. They were apparently healthy and work and live at places free of fumes and smoke. Peak expiratory flow rate (PEFR) was measured in all subjects. However, full spirometry work up was done on 100 bakery workers and 100 control subjects that had been selected using simple random sampling technique. The most frequent pulmonary symptoms among the bakery workers were sneezing and running nose (53.30%) and periodic breathlessness/chest tightness (23.16%) while the symptom of cough/phlegm present in (21.53%) of the subjects. The mean PEFR of the bakery workers (463.20 + 51.39 L/ min) was significantly lower (P < 0.0001) than that of the control subjects (538.0 + 47.23 L/min). Similarly, the mean values of FEV1, FVC and FEV1% were also significantly lower than the control subjects. The findings indicate that respiratory symptoms are common during the working hours among the bakery workers and 23.16% of the subjects studied suffered some degree of airway obstruction.

Adolescent↗

Changes in work practice after a respiratory health survey among welders in New Zealand.

AIMS: To assess changes in work practice among eight New Zealand engineering sites, following a study of occupational respiratory symptoms in welders two years previously. METHODS: In 1996, we found that an acute decrease in lung function was more common in welders working without local exhaust ventilation. Findings were reported back to management, study participants and the media. Two years later we re-visited the eight welding sites. RESULTS: Of the eight engineering sites, two had local exhaust ventilation present in both Study 1 and Study 2, one site had installed local exhaust ventilation in part of the site since Study 1 and one site had moved to larger premises. The remaining four sites had no exhaust ventilation or change to the workplace between studies. Five welders (12.8%) used respiratory protection in both Study 1 and Study 2, seven welders (18%) used respiratory protection in Study 1 but not Study 2, four welders (10.3%) did not have respiratory protection in Study 1 but did in Study 2 and nine welders (23.1%) did not use respiratory protection at all in Study 1 or Study 2. CONCLUSION: Further effort is required to ensure that such studies lead to significant improvements in the work environment.

Air Pollutants, Occupational↗

Do health care workers need to wear masks when caring for patients with pulmonary tuberculosis?

Outbreaks of hospital acquired tuberculosis (TB) in the 1990s, some of which affected staff, highlight the fact that TB still poses a risk to health care workers (HCWs). This risk is best minimised by the primary controls of early identification and treatment, good infection control practice such as early isolation, patients covering mouths when coughing, and engineering controls such as negative pressure isolation. There is no direct evidence to prove that the use of respiratory protective devices has prevented HCWs from acquiring TB, but modelling has shown that environmental controls are not enough to prevent exposure. Masks that filter aerosols (including TB) and have at least 95% efficiency of filtering particles 0.3 micron in diameter can reduce exposure. Environmental controls in the United Kingdom (UK) do not (always) include a specified minimum number of air-changes per hour or negative pressure. Therefore it seems reasonable to advise that HCWs should use masks as advocated by national guidelines for high risk procedures. Masks are also of value when entering any body cavity or dissecting any viscus/organ in which TB is suspected, as in the necropsy room or operating theatre. This is recommended in current guidelines from the United States but not those from the UK.

Guidelines as Topic↗

Developing a Respiratory Protection Program. Understanding the written elements.

1. Respirators can be the last defense for the estimated 5 million employees who use them for protection from dusts and fibers, fumes, mists, gases, vapors, and biological hazards. Because of these potentially lethal respiratory hazards, occupational and environmental health nurses need to be able to determine the need for, understand, develop, update, and implement an actionable respiratory protection program (RPP). 2. Regulated per 29 CFR 1910.134, a written RPP becomes the map or guideline process specific to the workplace that needs to be followed to ensure employee protection. 3. The nine required written elements of a RPP include respirator selection; fit testing; respirator use in routine and emergency situations; respirator maintenance and change schedules; ensuring adequate breathing air supply, quantity, and flow for atmosphere supplying respirators; regular evaluation of program effectiveness; medical evaluation; training employees in the respiratory hazards in routine and emergent situations; and training employees in proper use of the respirator. 4. Occupational and environmental health nurses are in a unique position to be a RPP program administrator, its designated licensed health care professional, or an active member of a team implementing the RPP process.

Equipment Design↗

Filtration efficiency of the ramathibodi nasal filter evaluated by rhinomanometry in high concentration level of laser smoke particle.

Under conditions with a high concentration level of laser smoke particles, the filtration efficiency of the Ramathibodi nasal filter was studied. Different kinds of filter material in the Ramathibodi nasal filter were evaluated in human adults with an anterior standard rhinomanometric method. The Ramathibodi nasal filter with three-layers of a half-face mask filter and a 4 mm thickness polyurethane foam put inside was applied in a simulated human airway. The experiment was conducted in the Otolaryngology Department, Ramathibodi Hospital from October to December 2001. The amount and size of laser smoke particles were measured by a laser diode portable dust monitor. The amount of residual laser smoke particles in the simulated human airway without the Ramathibodi nasal filter of PM2.5, PM10 and PM15 were 100.91 +/- 7.65, 109.10 +/- 7.87 and 120.18 +/- 14.28 mcg/m3 respectively. The amount of residual laser smoke particles in the simulated human airway with the Ramathibodi nasal filter of PM2.5, PM10 and PM15 were 85.55 +/- 3.42, 92.18 +/- 4.40 and 99.72 +/- 5.02 mcg/m3 respectively. The filtration efficacy of the Ramathibodi nasal filter showed a high statistically significant difference with a p-value of <0.001 for three particle sizes. High concentration of laser smoke particles in an operative room represented suspended particulate matters which are very dangerous for human healths. The Ramathibodi nasal filter as a personal respiratory protective device applied in human nasal vestibules could protect the human airway from atmospheric suspended particulate matter.

Adult↗

Effects of duration of exposure to wood dust on peak expiratory flow rate among workers in small scale wood industries.

OBJECTIVES: Occupational and environmental lung diseases are one of major problems of clinical medicine. Several occupations are associated with adverse health effects, and the lung is one of the parts of the body most vulnerable to airborne hazards. Exposure to gas, fume, and dust can lead to occupational lung diseases. The objective of the study was to assess the effects of wood dust and the duration of exposure on peak expiratory flow rate (PEFR) and additionally, to minimize possible health risks for wood workers by providing them with information about wood dust related hazards. METHODS: The present study was conducted under the supervision of the Department of Physiology, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the year 2002. It was designed as a matched case-control cross-sectional study of spirometry in forty six non-smoking wood workers, aged 20-60 years, who worked without the benefit of wood dust control ventilation or respiratory protective devices. PEFR measurements were performed using an electronic spirometer. RESULTS: The present study results demonstrated that in wood workers exposed for longer periods than 8 years, PEFR was significantly reduced as compared with their matched controls. CONCLUSION: Based on the results of the present study, we conclude that PEFR in wood workers is impaired and the stratification of results shows a dose-response effect of years of wood dust exposure on its value.

Adult↗

Occupational exposure to hexavalent chromium. Final rule.

The Occupational Safety and Health Administration (OSHA) is amending the existing standard which limits occupational exposure to hexavalent chromium (Cr(VI)). OSHA has determined based upon the best evidence currently available that at the current permissible exposure limit (PEL) for Cr(VI), workers face a significant risk to material impairment of their health. The evidence in the record for this rulemaking indicates that workers exposed to Cr(VI) are at an increased risk of developing lung cancer. The record also indicates that occupational exposure to Cr(VI) may result in asthma, and damage to the nasal epithelia and skin. The final rule establishes an 8-hour time-weighted average (TWA) exposure limit of 5 micrograms of Cr(VI) per cubic meter of air (5 [mu]g/cu m). This is a considerable reduction from the previous PEL of 1 milligram per 10 cubic meters of air (1 mg/10 cu m, or 100 [mu]g/cu m) reported as CrO3, which is equivalent to a limit of 52 [mu]g/cu m as Cr(VI). The final rule also contains ancillary provisions for worker protection such as requirements for exposure determination, preferred exposure control methods, including a compliance alternative for a small sector for which the new PEL is infeasible, respiratory protection, protective clothing and equipment, hygiene areas and practices, medical surveillance, recordkeeping, and start-up dates that include four years for the implementation of engineering controls to meet the PEL. The final standard separately regulates general industry, construction, and shipyards in order to tailor requirements to the unique circumstances found in each of these sectors. The PEL established by this rule reduces the significant risk posed to workers by occupational exposure to Cr(VI) to the maximum extent that is technologically and economically feasible.

Air Pollutants, Occupational↗

[Retention of radioactive aerosols (products of radon-222 decay) by various types of anti-dust masks].

The paper presents results of measurements of the efficiency of retention of radon decay products, occurring as radioactive aerosols, by anti-dust masks. The efficiency of three types of masks: PM-1, PM-3, PP-2 "Delta" was studied under various conditions of equilibrium between radon and products of its decay in the air. It was concluded that the efficiency of retention of radon decay products, occurring as radioactive aerosols, by the mentioned types of masks, comes to 75--87%. Anti-dust PM-1 (F-14 filter) and PM-3 (F-13 filter) masks are recommended as most efficient.

Aerosols↗