PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spirometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Breath sound intensity in patients with airway provocation challenge test positive by spirometry but negative for wheezing: a preliminary report.

Wheeze detection has been proposed as an indicator of bronchial responsiveness during airway provocation challenge (APC) test. However, there is evidence that wheeze may be occasionally absent in subjects whose APC is positive by spirometry. We tested the hypothesis that, in this case, inspiratory breath sound intensity (BSI) over the chest is noticeably decreased. Six patients (3 asthmatics and 3 patients with atopic rhinitis) were selected, whose forced expiratory volume in 1 s (FEV1) fell by 20% or more at the end point of the challenge in the absence of concurrent wheezing. Lung sounds were recorded at the right posterior lung base and analysed by computer. Inspiratory BSI at the end point of the challenge was markedly decreased in all patients, a change almost completely reverted by the inhalation of 200 micrograms of salbutamol in all of them but one. These results support the view that BSI monitoring is potentially useful as an indicator of bronchoconstriction during bronchial provocation testing. However, further studies are necessary to confirm this hypothesis.

Adolescent↗

Arm span-height relationships in patients referred for spirometry.

Arm span has been proposed as a surrogate for standing height in the prediction of lung volumes in patients with thoracic deformities or who are unable to stand. The relationship between arm span and height has previously been reported as either a fixed ratio unaffected by age or as a regression equation in which the ratio varies as a function of age. We studied the relationship between standing height, arm span, race, sex, and age in 202 patients (ages 20 to 88 yrs) referred for screening spirometry. Multiple linear regression analysis found arm span, race, sex, and age to be predictive of standing height (r2 = 0.8659, p < 0.0001). Subgroup analysis revealed that age was a significant factor among males of either race, but not among females of either race. Fixed arm span to height ratios were also calculated for each group and may be used to estimate standing height with reasonable accuracy except at extremes of stature.

Adult↗

Exhaled nitric oxide following repeated spirometry or repeated plethysmography in healthy individuals.

Subjects with asthma have higher concentrations of exhaled nitric oxide (NO) than normal individuals. It has been demonstrated that in asthmatics, repeated FVC maneuvers reduce NO. Although the cause of this phenomenon is not known, it has been hypothesized that deep breaths associated with FVC maneuvers reduce exhaled NO by affecting neural sources of NO, possibly via a mechanism related to the pathobiology of asthma. To establish whether FVC maneuvers influence NO concentrations in normal individuals, we measured exhaled NO at baseline values and after FVC maneuvers performed every 15 min for 1 h in subjects without asthma. To investigate the role of deep breaths in reducing exhaled NO, we compared these results with concentrations of exhaled NO after plethysmography. Repeated FVC maneuvers over 60 min produced a decrease in NO concentrations in mixed expired gas (F(E)NO; 24.6 +/- 5.1% decrease for F(E)NO, p < 0. 01 versus baseline). In contrast to the results after spirometry, repeated specific airway conductance (sGaw) maneuvers do not have a significant effect on F(E)NO (p = 0.16). These results, which demonstrate that in nonasthmatic subjects FVC maneuvers-but not panting maneuvers-produce a fall in NO, suggest that the mechanism responsible for the reduction in exhaled NO after FVC maneuvers is related to volume history of the lung rather than the pathobiology of asthma.

Adult↗

Design strategies for longitudinal spirometry studies: study duration and measurement frequency.

Measuring the longitudinal change in FEV(1) is useful for assessing the adverse effects of respiratory exposures and pulmonary diseases. Investigators seek to estimate the "true" mean FEV(1) slope (mu(beta)) of an infinite population. The difference between the estimated mean FEV(1) slope (mu(beta)) and the true mean slope, resulting from biological variation and measurement errors, can be minimized by increasing the number of subjects (N), years of follow-up (D), or the frequency of measurements (P). We defined maximum error e(max) such that P[|mu(beta) - mu(beta)| < or = e(max)] = 0.95, and thus e(max) is one-half the width of the 95% confidence interval for mu(beta). We computed the values of e(max) on the basis of actual data obtained from 160 coal miners and working nonminers who had completed 11 spirometry measurements, using recommended equipment and procedures, at 6-mo intervals over 5 yr. Individual 5-yr FEV(1) slopes (Delta FEV(1)) were calculated by linear regression. For a range of values of N, D, and P, tables are provided for e(max), the magnitude of detectable differences in Delta FEV(1) between two groups, and the recommended number of subjects needed in each of two groups to reliably detect the anticipated differences in Delta FEV(1). The tables provide unique guidance for investigators in selecting among various study design options.

Adult↗

Serial relationships between ventilation-perfusion inequality and spirometry in acute severe asthma requiring hospitalization.

Patterns of VA/Q distribution and their relationship to spirometric indices were studied in 10 patients with acute severe asthma requiring hospitalization (7 women and 3 men 41.0 +/- 5.6 yr of age, mean +/- SEM) on admission and during subsequent recovery. On admission, all patients received the standard therapeutic regimen for our hospital. Spirometry and essentially noninvasive multiple inert gas elimination measurements were obtained serially, approximately once every day, whereas conventional arterial blood gases were determined every 3 days. On admission, all patients showed severe air-flow obstruction (FEV1/FVC% = 34.1 +/- 4.3%) and moderate to severe hypoxemia without CO2 retention (PaO2 = 50.5 +/- 2.6 mm Hg; PaCO2 = 37.1 +/- 2.4 mm Hg; AaPO2 = 53.7 +/- 3.0 mm Hg). Nine of the 10 patients showed bimodal blood flow distributions (dispersion of blood flow distribution, log SD Q = 1.34 +/- 0.11; normal range, 0.3 to 0.6) with only small amounts of shunt (1.09 +/- 0.8%). However, no significant interindividual correlations were observed between maximal expiratory flow rates (FEV1 and FEF25(-75) and log SD Q (r2 = 0.14 and 0.006, respectively). This lack of correlation persisted throughout hospitalization. Despite both clinical and spirometric improvement in all patients, there was simultaneous improvement in VA/Q matching in only one patient. Statistically significant negative correlations between maximal expiratory flow rates and gas exchange did develop toward the end of the study (Weeks 3 and 4 after discharge) when maximal recovery of physiologic changes associated with the acute asthma attack was achieved.(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗

Breath-stacking increases the depth and duration of chest expansion by incentive spirometry.

Although the objective of incentive spirometry is to achieve and hold high lung volumes, many patients with pain or weakness are unable to sustain the effort needed to perform effective exercises. We questioned whether using a one-way valve to prevent exhalation would allow rest between inspiratory efforts and cause volume to cumulate during successive tidal efforts, improving both the depth and duration of the inspiratory maneuver. We studied 26 cooperative but naive patients recovering from surgery, trauma, or critical illness whose pain or weakness impaired ability to achieve and sustain deep inspiration. All subjects breathed via mouthpiece from a spirometer prefilled with 100% oxygen. Three different maneuvers were performed in random order by all subjects: (1) standard inspiratory capacity without valve or inspiratory hold, (2) inspiratory capacity (IC) with breathholding aided by a one-way valve, and (3) uncoached breath-stacking, during which successive tidal breaths were cumulated by one-way valving. A fourth maneuver was added in the last 13 subjects studied: an initial coached IC effort with subsequent valved stacking of tidal efforts. When compared with IC, "breath stacking" (valved) maneuvers increased inspired volume by an average of 15 to 20% (p less than 0.05). More importantly, there was a severalfold increase in the time over which high lung volume was sustained (p less than 0.001). Our results indicate that one-way valving helps to achieve and sustain deep inspiration, even in uncoached patients.

Humans↗

Trial of standard versus modified expiration to achieve end-of-test spirometry criteria.

To assess whether satisfying American Thoracic Society (ATS) end-of-test spirometry criteria can be enhanced by modifying the patient's expiratory technique, we conducted a cross-over trial of two expiratory techniques in 48 patients with a range of pulmonary functions (Group 1, n = 12: FEV1/FVC < 0.45; Group 2, n = 11: FEV1/FVC, 0.45 to 0.60; Group 3, n = 16: FEV1/FVC, 0.61 to 0.74; Group 4, n = 9: FEV1/FVC > or = 0.75). After randomizing the order of testing, each patient performed three exhalations using a "standard" forced expiratory maneuver and a modified expiratory technique consisting of an initial maximal expiratory effort followed by a "relaxed expiration" for as long as possible. Patients initiated "relaxed expiration" when instructed by the supervising technician, who issued the instruction to relax when expiratory airflow fell to < or = 200 ml/s (as determined by flow-volume loop analysis). ATS end-of-test criteria were satisfied significantly more often using the modified expiratory technique (58.3% of testing sessions) than using the standard technique (18.7% of sessions, p = 0.001) because of prolongation of the forced expiratory time (FET) with the modified technique in all patient groups. In the 38 patients with FEV1/FVC < or = 0.75, the largest FVC and FET rose significantly using the modified expiratory technique, without compromising the largest FEV1 in any group. In patients with FEV1/FVC > or = 0.75, FET increased without concomitant changes in FVC or FEV1.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

Adolescent↗

A controlled trial of intermittent positive pressure breathing, incentive spirometry, and deep breathing exercises in preventing pulmonary complications after abdominal surgery.

Controversy exists regarding the routine use of aids to lung expansion in the prevention of pulmonary complications after abdominal surgery. We prospectively randomized 172 patients into 1 of 4 groups: the control group (44 patients) received no respiratory treatment, the IPPB group (45 patients) received intermittent positive pressure breathing therapy for 15 min 4 times daily, the IS group (42 patients) was treated with incentive spirometry 4 times daily, and the DBE group (41 patients) carried out deep breathing exercises under supervision for 15 min 4 times daily. Roentgenographic changes, observed 24 h after surgery, were comparable in the 4 groups (20.5 to 36.6%). Pulmonary complications were defined as the development of 3 or more of 6 new findings: cough, phlegm, dyspnea, chest pain, temperature greater than 38 degrees C, pulse rate more than 100 beats/min. The frequency of development of pulmonary complications was 48% in the control group, 22% in the IPPB group (p less than 0.05), 21% in the IS group (p less than 0.05), and 22% in the DBE group (p less than 0.05). Side effects of respiratory treatment were observed only in the IPPB group (18%; p less than 0.05). Hospital stay in patients undergoing upper abdominal surgery was significantly shorter in the IS group (mean +/- SD, 8.6 +/- 3 days) than in the control group (13 +/- 5 days). This difference was not observed for the other 2 treatment groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Abdomen↗

A longitudinal study of spirometry in young black and young white children.

Spirometry was performed longitudinally over a period of 8 yr on 72 children (29 black females, 26 black males, 9 white females, and 8 white males) starting as early as 3 yr of age. Weighted straight-line regressions of 6 maximal expiratory flow-volume parameters--forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), forced expiratory flow during the middle half of the FVC (FEF25-75), and maximal expiratory flows after 50 and 75% of the FVC had been exhaled (Vmax50 and Vmax75, respectively) - on height were computed and were found to describe adequately the data over a height range of 100 to 150 cm. Statistical comparisons of regression lines revealed significant differences for FVC and FEV1 when white females were compared with white males, white females with black females, and white males with black males, but not for black females with black males. Regressions of FEF25-75 and Vmax50 for black females were significantly lower than for white females, and those for white males were lower than those for white females, but no differences were detected when black females and white males were compared with black males. Only white females compared with black females revealed significant differences for Vmax75. There were no significant differences for any of the comparisons for PEF. The data presented expand the age range for evaluating lung function in children, indicate the feasibility of testing pre-school-age subjects, and provide new approaches to analysis of longitudinally collected information.

Anthropometry↗

Effects of spirometry standards in two occupational cohorts.

Characteristics of subjects with nonreproducible lung function tests (test failures) are described in two studies of occupational respiratory disease. According to current guidelines for spirometry, subjects with test failure are excluded from analyses of epidemiologic pulmonary function data. Among 415 Chinese cotton textile workers, the prevalence of byssinosis was 5.8% for subjects with repeatable tests and 13.3% for subjects with test failure. In regression analysis, the estimate of the association between cotton dust exposure and FEV1 decreased when subjects with test failure were excluded. In a second cohort of 378 asbestos-exposed machinists, the prevalence of chronic bronchitis was significantly greater among those with test failure. Considering only subjects with repeatable measurements, FEV1 was lower among textile workers with byssinosis and machinists with chronic bronchitis than among their asymptomatic coworkers. This suggests that, on average, subjects with poor test performance had lower (unobserved) FEV1 values, and therefore that the exclusion of subjects with test failure may cause selection bias.

Adult↗

Once-daily sustained-release theophylline reduces diurnal variation in spirometry and symptomatology in adult asthmatics.

In 22 adult asthmatics (mean age, 55.2 +/- 15.4 yr), we compared Uniphyl given once a day to Theo-Dur given twice a day using a randomized, double-blind, two-phase crossover trial. All patients demonstrated acute bronchodilator responsiveness (FEV1 increase greater than 15%) to inhaled salbutamol and were dependent upon both orally administered theophylline and inhaled salbutamol at time of entry. Each phase lasted 9 days, the first 2 days of which were a theophylline washout. Uniphyl was given once a day at 8 P.M. and Theo-Dur was given twice a day at 8 A.M. and at 8 P.M. For each patient, the total daily theophylline dose was the same during both phases. Asthma symptoms, drug side effects, and PEFR were recorded at 8 A.M. and at 4 and 8 P.M. each day. On Days 7, 8, and 9 of each phase, serum theophylline concentrations were measured and spirometry was performed at 8 A.M. and at 4 and 8 P.M. The results demonstrated significant differences in both pharmacokinetic and clinical efficacy between the 2 drugs. Uniphyl produced greater "peak" and lower "trough" theophylline concentrations than did Theo-Dur, although both lower "trough" theophylline concentrations than did Theo-Dur, although both drugs maintained concentrations within the accepted therapeutic range. In contrast to the pharmacokinetic findings, Uniphyl was associated with significantly less fluctuation in pulmonary function throughout the day, and the values at 8 A.M. for FEV1, PEFR, and wheeze demonstrated significant clinical efficacy in favor of Uniphyl.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Health locus of control and adherence with home spirometry use in lung transplant recipients.

Home monitoring is an effective tool that can be used to promote the health of lung transplant recipients, but only if the recipients transmit data to the healthcare team. This study examines the relationship of the Multidimensional Health Locus of Control scale to adherence with home spirometry use. Form C of this scale was mailed to 139 eligible lung and heart-lung transplant recipients. Eighty-three respondents returned the questionnaire. The respondents were on average 4 years older and had greater adherence than nonrespondents. Men tended to score higher than women on all the subscales. These scales were not related to type of transplant or underlying disease. Adherence was also unrelated to the Multidimensional Health Locus of Control scale, with little difference in adherence across persons with various levels of the health locus of control subscales.

Female↗

Questionnaires, spirometry and PEF monitoring in epidemiological studies on elderly respiratory patients.

Questionnaires are the most used subjective instrument of measurement in respiratory epidemiology. The standardisation of the questionnaires aims to limit bias by maximising validity and reliability, and comparability. Within the European Union project BIOMED1, a compendium of respiratory standard questionnaires (CORSQ) was developed for adults covering 18 topics from general information to early life events, through environmental risk factors and respiratory symptoms and diseases. Reliable spirometry data needs a rigorous quality control programme, as in the "Salute Respiratoria nell'Anziano" (Sa.R.A.) project, Italian for "Respiratory Health in the Elderly". Reproducibility rates were 95.8% for forced expiratory volume in one second (FEV1). Male sex and age were independent risk factors for a poorer reproducibility, as well as cognitive and physical impairment (shorter 6-min walking distance) and lower educational level for a poorer acceptability. Reference values for people aged 65-85 yrs have been produced; these results suggest that the effect of aging should be corrected for physical and mental disability. A revision of interpretative strategies included in current guidelines is needed. Peak expiratory flow monitoring has several methodological problems: reliability and sensitivity of the measurement in order to detect changes in airway calibre; compliance with long-term monitoring; choice of the best variability index; difference between asthmatic and nonasthmatic subjects; age-related differences. Despite these methodological problems, peak expiratory flow monitoring has been successfully used in the evaluation of the effects of air pollution in normal and asthmatic subjects, and in the elderly.

Adult↗

Chronic dyspnea unexplained by history, physical examination, chest roentgenogram, and spirometry. Analysis of a seven-year experience.

The purpose of this article is to describe the spectrum and frequency of diseases presenting as unexplained dyspnea and to develop a logical diagnostic approach to such patients. Seventy-two consecutive physician-referred patients had dyspnea greater than one-month duration unexplained by the initial history, physical examination, chest roentgenogram, and spirometry. Patients underwent a standard diagnostic evaluation. A definite cause for dyspnea was recognized in 58 patients, and no answer was found in 14. Twenty-two diseases were recognized in the patient group. Dyspnea was due to pulmonary disease in 26 (36 percent) patients, cardiac disease in ten (14 percent) patients, hyperventilation in 14 (19 percent) patients, and only 3 patients had extrathoracic disease causing dyspnea. Age younger than 40 years, intermittent dyspnea, and normal alveolar-arterial oxygen pressure difference (P[A-a]O2) at rest breathing room air was strongly predictive of bronchial hyperreactivity or hyperventilation. No patient diagnosed as having disease of the lung parenchyma or vasculature had a P(A-a)O2 less than or equal to 20 mm Hg. The differential diagnosis to explain dyspnea in patients with nondirective histories, normal findings from physical examinations, normal chest roentgenograms, and normal spirograms is extensive. The patient's age and measurement of gas exchange at rest help to formulate a diagnostic approach.

Adult↗

Stacked inspiratory spirometry reduces pulmonary shunt in patients after coronary artery bypass.

Atelectasis is a major factor in postoperative morbidity for patients undergoing cardiopulmonary surgery. We evaluated the effectiveness of stacked inspiratory spirometry (STIS) in 17 patients status postcoronary artery bypass graft in a nonrandomized fashion. We measured pulmonary shunt as an endpoint, and compared the magnitudes before and after the STIS maneuver. Our results showed an 8.66 percent reduction in pulmonary shunt (p < 0.05). The reduction in shunt was modest; however, repetitive maneuvers might result in greater improvement.

Aged↗

Cardiorespiratory responses to incremental exercise in sarcoidosis patients with normal spirometry.

Patients with sarcoidosis are known to have histologic pulmonary abnormalities despite normal lung fields or conventional pulmonary function or both. These patients permit a useful assessment of the alleged greater sensitivity of the various measurements made during incremental cardiorespiratory exercise testing. Abnormal responses on such testing may provide insight into such complaints as dyspnea in these patients. Incremental exercise testing was performed on 30 patients with biopsy-proven sarcoidosis who had normal spirometry; 13 had clear lung fields radiographically. Of these patients, the 21 who had normal single-breath diffusing capacity for carbon monoxide (Dsb; [group A]) were compared with the 9 who had decreased Dsb (group B). Half of the group A patients had excessive ventilation and 38% had increased dead space to tidal volume ratio (Vd/Vt), but frequencies of these abnormalities were greater in group B, 89 and 78%, respectively. Ventilatory response, as minute ventilation to oxygen consumption ratios ventilatory equivalents, and deadspace to tidal volume ratio (Vd/Vt) ratios were higher in group B. Widened alveolar-arterial oxygen pressure differences were seen in 7 of 9 group B patients but only 1 of 17 group A patients. This study supports the clinical impression that occult pulmonary impairment may be present in patients (in this case, sarcoidosis patients) with normal pulmonary function, and corroborates the utility of exercise testing in demonstrating such impairment. Reduction in Dsb predicted greater frequency of abnormal exercise responses, especially in oxygenation.

Adult↗

Gas trapping as a predictor of positive methacholine challenge in patients with normal spirometry results.

Methacholine challenge studies are often conducted to diagnose asthma in patients with mild or intermittent respiratory symptoms when screening spirometry results are normal. We hypothesized that in patients with increased nonspecific bronchial hyperreactivity (NSB-HR), gas trapping might be present and that this information could be a factor in clinical decision making. To assess the relationship between gas trapping and NSBHR, we conducted a retrospective chart review of 500 patients who had undergone pulmonary function testing, including lung volume measurement and methacholine challenge. Measurements of airflow, lung volumes, and methacholine PC20 values were compiled and analyzed. FRC was determined by body plethysmography (FRCB) and by helium dilution (FRC-He). FRCB-FRC-He, RV (percent of predicted) RV/TLC, and RV/TLC (percent of predicted) were used as measures of gas trapping. RV% and RV/TLC% were the best predictors of a PC20 < or = 8 mg/mL. In the subset of 169 patients who had FEV1/FVC > or = 90% of pred, an RV/TLC% value of 125% of predicted or greater had a positive predictive value of 62.5% and a negative predictive value of 62.0%. RV/TLC% was the only measure of gas trapping that was associated with a PC20 < or = 8 mg/mL (p < 0.05). Linear regression revealed no correlation between any measure of gas trapping and quantified PC20 value (< or = 16 mg/mL). These results suggest that patients with a normal FEV1/FVC who show gas trapping have an increased likelihood of a positive methacholine challenge study. Furthermore, in these patients, RV/TLC (percent of predicted) is the best predictor of a positive methacholine challenge and this parameter may be useful in raising the clinical suspicion of asthma in the large population of patients presenting with respiratory symptoms and normal flow rates.

Adolescent↗