PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Testing”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Use of an inclinometer to measure flexibility of the iliotibial band using the Ober test and the modified Ober test: differences in magnitude and reliability of measurements.

STUDY DESIGN: Test-retest design to evaluate the reliability of the measurement of iliotibial (IT) band flexibility using an inclinometer to measure the hip adduction angle. OBJECTIVES: The primary objective was to determine the intrarater reliability of the Ober test and the modified Ober test for the assessment of IT band flexibility using an inclinometer to measure the hip adduction angle. A secondary objective was to determine if a difference existed between the measurements of IT band flexibility between the Ober and modified Ober test. BACKGROUND: The Ober test and the modified Ober test are frequently used for the measurement of IT band flexibility. To date, data documenting the objective measurement of flexibility of the IT band is scarce in the literature. METHODS AND MEASURES: Sixty-one subjects, with a mean age of 24.2 (SD = 4.3) years, were measured during 2 measurement sessions over 2 consecutive days. During each measurement session, subjects were positioned on their left side and, with an inclinometer at the lateral epicondyle of the femur, hip adduction was measured during the Ober test (knee at 90 degrees of flexion) and the modified Ober test (knee extended). If the limb was horizontal, it was considered to be at 0 degrees, if below horizontal (adducted), it was recorded as a positive number, and if above horizontal (abducted), it was recorded as a negative number. RESULTS: The ICC values calculated for the intrarater reliability of the repeated measurement were 0.90 for the Ober test and 0.91 for the modified Ober test. Results of the dependent t test indicated a significantly greater range of motion of the hip in adduction using the modified Ober test as compared to the Ober test. DISCUSSION AND CONCLUSION: The use of an inclinometer to measure hip adduction using both the Ober test and the modified Ober test appears to be a reliable method for the measurement of IT band flexibility, and the technique is quite easy to use. However, given that the modified Ober test allows significantly greater hip adduction range of motion than the Ober test, the 2 examination procedures should not be used interchangeably for the measurement of the flexibility of the IT band.

Adult↗

[Evaluation of three testing strategies for detection of hepatitis C in a hospital medical consultation and in an HIV testing center].

AIMS: Testing for hepatitis C virus (HCV) is recommended. The purpose of this study was to evaluate the efficacy of HCV testing in a medical consultation without an appointment and in an HIV testing center based on three testing strategies: 1997 French Consensus Conference, "Lettre de la Direction Générale de la Santé" (January 1996), and extension to other risk factors. PATIENTS AND METHODS: For 6 months a free blood test was offered to any patient with a risk factor according to the literature. RESULTS: There were 1 736 new patients at the medical consultation and 1 616 at the testing center. The patients were younger at the testing center than at the medical consultation (31.1 vs 43.3 years; P<0.001). Acceptance of screening was better at the testing center (97.8% vs 75.2%; P<0.001). There were more patients exposed to one of the risk factors at the testing center (31.2% vs 13.9%; P<0.001). Tests were more efficient at the testing center: 30 HCV positive patients/1 616 (1.86%) vs 11/1 736 (0.63%, P<0.01). Tests based on the 1997 French Consensus Conference provided detection in 27/30 (90%) of HCV positive patients at the testing center but only 4/11 (36.3%) at the medical consultation (P<0.01). CONCLUSION: Testing was effective in both places but was more efficient at the testing center. Efficacy of the testing strategies differs significantly according to the place of screening. At the testing center, screening can be restricted to patients with a history of intravenous drug use and blood transfusion. At the medical consultation, screening should be extended to other risk factors.

Adult↗

Voluntary testing and counselling for HIV. "Are adults in rural communities ready to test?" A descriptive survey.

OBJECTIVE: To describe rural adult preparedness to test for HIV, perceived susceptibility, response to peer group opinion, perceived positive and negative outcome expectations of testing. DESIGN: Cross sectional descriptive study. SETTING: Mashonaland West Province, Zimbabwe. SUBJECTS: Purposive convenience sample; 204 adults, 102 females, aged 18 to 50. MAIN OUTCOME MEASURES: Stage of preparedness to test for HIV, perceptions of susceptibility, response to peer group opinion, negative and positive expectations about testing. RESULTS: None of the 204 participants had knowingly been tested for HIV prior to the study; 55.8% had heard about Voluntary Counselling and Testing (VCT) and 21.0% had thought about testing. Of these, 15 (34.8%) had already talked to somebody about testing. When compared with married respondents, significantly more singles expressed preparedness to test for HIV in the next six months (p = 0.040). Only 14.2% of respondents expressed willingness to pay for a test. Females worried more than males about "getting HIV in the future" (p = 0.019). Singles were more likely to worry about their partners' current HIV status than married and once married respondents (p < 0.001). When compared with women, men showed more likelihood of responding to pressure from friends to test for HIV (p = 0.039). Strongly articulated fears about testing included being seen by friends at a VCT centre, stigmatisation, violence and stress. Significantly more women than men were fearful that an HIV test would be painful (p = 0.006). Similarly, women were more fearful than men about taking an HIV test (p = 0.007), the possibility of waiting for the result (p = 0.022) and returning for results (p = 0.020). Anticipated positive outcomes of testing included getting assistance in the early stage of the disease. CONCLUSION: Knowledge of HIV status acquired voluntarily in a psychologically and socially supportive environment will be a significant motivator for individuals and their partners to initiate and maintain safer sexual behaviour. Our study showed some preparedness among adults from two rural communities to test for HIV. While current strategies to promote VCT in urban areas reflect sensitivity to many of the fears of adults expressed in this study, the initiative must be expanded to embrace rural communities. There is a need to build on positive perceptions about testing and embrace a strategy that disables fear, particularly among women. The initiative must go beyond the individual as the primary target and be promoted within the broader context of the community with the assistance of credible opinion leaders. It should also link closely with other services that offer primary prevention, pilot treatment and support activities.

Adult↗

Comparative testing for weak expression of D antigen: manual tube testing vs. a semiautomated IgG gel system.

Donor RBCs nonreactive in initial tests for D must be tested further for evidence of weak expression of D antigen. Performing this test in test tubes is labor intensive and prone to inconsistencies in readings (relative strength of agglutination) and interpretation (positive versus negative). These inconsistencies can lead to repeat testing, additional documentation, and delay in releasing units. We evaluated use of the Tecan MEGAFlex-ID pipettor to perform this test in anti-IgG gel cards. Results with this semi-automated gel test were compared with results obtained with 37 D- and 99 weak D samples, as determined by previous testing with a manual IAT tube test. Hands-on time was determined for both methods and both methods were evaluated for inconsistency, or nonagreement, between the interpretation of the current weak D test and the results on record for any prior donations. There were no discordant results obtained, with the majority of weak D samples giving stronger reactions with the gel test. The semiautomated gel test required less hands-on time, with an average savings of more than 70 seconds per test. There were no inconsistencies with the gel method, whereas manual tube testing was found to have an inconsistency rate of 0.035 percent of total samples tested. Semiautomated IgG gel is now used for all weak D testing, with a labor savings of more than 10 hours per week. Thus far, more than 70,000 donors have been tested, with no inconsistencies reported.

Journal Article↗

Test offering, not additional information, may increase HIV testing uptake in a knowledgeable population.

OBJECTIVES: To evaluate patient HIV knowledge and testing experience and assess the effect of an HIV informational handout on HIV testing propensity. DESIGN: Cross sectional, descriptive techniques were employed to assess demographics, HIV knowledge and HIV testing experience. A randomized controlled trial was performed to determine if an HIV/AIDS information sheet influenced testing propensity. SETTING: Blantyre Adventist Hospital Outpatient Clinic. SUBJECTS: Non-emergency patients over 18 years old attending during consulting hours. INTERVENTIONS: All subjects answered a questionnaire. For the randomized controlled trial component, half received an HIV information handout. MAIN OUTCOME MEASURES: Proportions were calculated to evaluate testing experience. Logistic regression was used to assess impact of written information and demographics on HIV testing propensity. RESULTS: 490 participants were recruited, of whom 57% had never been tested for HIV. Of the untested, 88% had never been offered an HIV test. Of those that had never been offered a test, 46% desired one. The sample was highly knowledgeable about HIV. Reading an information sheet had no impact on HIV knowledge (p=0.736 to 0.788) or desire for testing (p=0.387). However, age (OR=0.97, 95%CI (0.95,0.99)) and gender (OR=1.85, 95%CI (1.06, 3.23)) significantly correlated with testing propensity. CONCLUSIONS: A large percentage of patients who have never been offered HIV testing desire testing. More frequent HIV test offering by clinicians could improve testing rates. Clinician education programmes should be developed to increase test offering. Furthermore, written health information in a setting of high HIV/AIDS knowledge may not change behaviour. Alternative methods should be employed to encourage HIV testing uptake.

AIDS Serodiagnosis↗

Power wheelchair range testing and energy consumption during fatigue testing.

The range of a power wheelchair depends on many factors including: battery type, battery state, wheelchair/rider weight, terrain, the efficiency of the drive train, and driving behavior. The purpose of this study was to evaluate the feasibility of three methods of estimating power wheelchair range. Another significant purpose was to compare the current draw on pavement to current draw on an International Standards Organization (ISO) Double Drum tester at one m/sec. Tests were performed on seven different power wheelchairs unloaded, and loaded with an ISO 100 kg test dummy. Each chair was configured according to the manufacturer's specifications, and tires were properly inflated. Experienced test technicians were used for the tennis court tests, and treadmill tests. An ISO 100 kg test dummy was used for the ISO Double Drum test. Energy consumption was measured over a distance of 1500 m for each of the three test conditions. The rolling surface was level in all cases. Repeated measure analysis of variance (ANOVA) revealed a significant difference (p = 0.0001) between the predicted range at maximum speed for the three tests. Post hoc analysis demonstrated a significant difference (p < 0.01) in estimated range at maximum speed between the Double Drum test and the treadmill test, as well as between the Double Drum test and the tennis court test. Our results indicate no significant difference (p > 0.05) between the predicted range at maximal speed between the treadmill and tennis court tests. A simple relationship does not exist between the results of range testing with the Double Drum tester and the tennis court. An alternative would be to permit the use of a treadmill for range testing as simple relationships between all pertinent treadmill and tennis court range data were found. For the Double Drum tester used, the current demand is higher than under normal usage. This presents a problem as current is related to load torque in a power wheelchair. Hence, the Double Drum tester friction must be reduced. The predicted range for the tennis court test at maximum speed ranges from a low of 23.6 km to a high of 57.7 km. The range of the power wheelchair can be improved by the use of wet lead acid batteries in place of gel lead acid batteries.

Electric Power Supplies↗

Counseling and testing for HIV prevention: costs, effects, and cost-effectiveness of more rapid screening tests.

New rapid human immunodeficiency virus (HIV) antibody tests permit many individuals to receive test results and appropriate counseling at one clinic visit. Because currently used tests require significant time for processing, all individuals must return for a second visit for test results and counseling. Since return rates for the second visit are low, the more rapid tests present an opportunity to improve the efficiency of HIV counseling and testing. The authors compared the costs and effectiveness of the currently used counseling and testing procedure and a streamlined procedure made possible by the new, more rapid screening tests. When test-positive clients are given preliminary screening test results, the rapid procedure is more cost-effective than the current procedure. Since over 90% of the clients in most clinics will test negative, the rapid counseling and testing procedure allows the vast majority of clients to be counseled and tested and to receive their results and posttest counseling in one visit. However, in the case where the goal of HIV counseling and testing is to focus only on infected individuals, if information regarding a positive result from the rapid screening test is not given to clients at the initial visit before a confirmatory test is performed, then the rapid counseling and testing procedure is not more cost-effective than the current procedure.

AIDS Serodiagnosis↗

No advantage of the new combined octreotide-GHRH test over established GH-stimulation tests in the diagnosis of growth hormone deficiency (GHD) in adults.

OBJECTIVE: To evaluate the sensitivity and specificity of a combined octreotide (SMS)-GHRH test we compared it with established GH stimulation tests in the diagnosis of growth hormone deficiency (GHD) in adults. DESIGN: Because there is no universally agreed gold standard for the diagnosis of GHD in adults it is difficult to define the relative merits of different tests in patients with structural pituitary disease. We have addressed this by grouping patients according to the degree of concordance between three established tests (insulin (IHT), arginine (ARG) and GHRH stimulation test (GHRH)) and serum IGF-I levels and have subsequently analysed the frequency destribution of test results across defined groups: group 1, with complete GHD in all tests, group 2, with differences between tests with regard to the diagnosis of GHD and group 3, with normal GH response in all tests. The patients also underwent a new combined SMS-GHRH test, the results of which were compared with IHT, ARG and GHRH. MEASUREMENTS: Five hours after an octreotide injection GHRH was given intravenously and GH measured. RESULTS: ARG had the highest sensitivity (Se = 100%) and specificity (Sp = 100%) of the tests used. The IHT also diagnosed GHD with precision but showed false positive as well as false negative results (Se = 90%, Sp = 100%). Se and Sp of GHRH were lower than those of IHT and ARG (Se = 100%, Sp = 89%). The SMS-GHRH worked well and was superior to GHRH but had less precision than IHT and ARG (Se = 88%, Sp = 100%). CONCLUSION: We conclude that there is discordance between the three established tests and that the octreotide-GHRH test does not have any advantages for diagnosing GHD in adults. IGF-I levels can be used as a screening test only. The arginine test was the best conventional test in our study.

Adolescent↗

Reproducibility of constant-load treadmill testing with various treadmill protocols and predictability of treadmill test results in patients with intermittent claudication.

BACKGROUND: Most trials on the reliability of constant-load treadmill testing use one pair of treadmill settings (speed, grade) only. The question of whether the results can be applied to tests with different settings is left open. Also, claudication distances measured with differing settings are not comparable, rendering the comparison of the results from different trials difficult. This study evaluates the reliability of constant-load testing with various workloads and compares them with claudication distances achieved with walking at normal speed on level ground but also evaluates whether metabolic equivalent (MET) normalization can be used to translate the results of different treadmill tests into each other. METHODS: Fifteen patients with claudication underwent repeated treadmill testing with different treadmill settings, including speeds of 2.0, 3.2, and 4.0 km/h (1.25, 2.0, and 2.5 mph, respectively) and grades of 0% and 12%. The walking capacity was also tested on level ground with a speed chosen by the individual patient. Results of virtual treadmill tests with all possible combinations of the speeds and the grades used were predicted from real tests, with MET normalization. The relationship between real and predicted claudication distances was tested with regression modeling. RESULTS: Reliability coefficients (RCs) for the absolute claudication distance (ACD) were superior to RCs for the initial claudication distance. RCs for ACD ranged between 0.61 and 0.95, with increasing values found with increasing workloads. The best coefficients for the regression of measured on predicted claudication distances were achieved with a model on the basis of a power function (r = 0.963). The model was only appropriate for the prediction of group mean results from clinical trials but cannot be applied to single patient data. For proof of concept, the model was tested with six published studies in which the claudication distances of a patient sample were double treadmill tested with different workloads. The result of the second test was predicted from the first test, and estimated and measured claudication distances were compared. The mean difference (all trials) was 7.9%, whereas the maximum difference amounted to 16.5%. CONCLUSION: For an optimal treadmill test reliability, higher workloads should be used and ACD should be preferred over initial claudication distance. MET normalization provides the basis for the comparability of treadmill test results achieved with different test conditions.

Aged↗

A quantitative immunochemical faecal occult blood test is more efficient for detecting significant colorectal neoplasia than a sensitive guaiac test.

BACKGROUND: The sensitive guaiac faecal occult blood test, Haemoccult SENSA (HOS; Beckman Coulter, Fullerton, CA, USA), is our standard screening test for significant colorectal neoplasia. We evaluated an automatically-developed, quantified human haemoglobin immunochemical faecal test, OC-MICRO (Eiken Chemical Co., Tokyo, Japan), to improve test specificity and so reduce the colonoscopy burden. AIM: To compare guaiac faecal occult blood test and immunochemical faecal test diagnostic efficacy and costs for identifying significant neoplasia. METHODS: Colonoscopies were performed on patients who prepared three daily guaiac faecal occult blood tests with or without immunochemical faecal tests. RESULTS: Total colonoscopy was performed on 151 subjects who prepared both guaiac and immunochemical faecal tests (group 1) and the positive predictive values (PPV) were also compared to those of 162 subjects undergoing colonoscopy for positive guaiac faecal occult blood tests (group 2). In group 1, comparative sensitivity, specificity, and PPVs for significant neoplasia with guaiac faecal occult blood test were 75%, 34%, and 12% (PPV, 18% for group 2) and with immunochemical faecal test were 75%, 94% and 60% (P < 0.01 for specificity). The number of colonoscopy examinations needed to detect a significant neoplasm because of positive faecal occult blood tests was six to eight with HOS and two with OC-MICRO at 21-31% the cost of evaluating a positive guaiac faecal occult blood test. CONCLUSION: An immunochemical faecal test maintains the high sensitivity of guaiac faecal occult blood test, but significantly reduces the colonoscopy burden and screening costs.

Aged↗

Is electrodermal testing as effective as skin prick tests for diagnosing allergies? A double blind, randomised block design study.

OBJECTIVE: To evaluate whether electrodermal testing for environmental allergies can distinguish between volunteers who had previously reacted positively on skin prick tests for allergy to house dust mite or cat dander and volunteers who had reacted negatively to both allergens. DESIGN: Double blind, randomised block design. SETTING: A general practice in southern England. PARTICIPANTS: 15 volunteers who had a positive result and 15 volunteers who had a negative result on a previous skin prick test for allergy to house dust mite or cat dander. INTERVENTION: Each participant was tested with 6 items by each of 3 operators of the Vegatest electrodermal testing device in 3 separate sessions (a total of 54 tests per participant). For each participant the 54 items comprised 18 samples each of house dust mite, cat dander, and distilled water, though these were randomly allocated among the operators in each session. A research nurse sat with the participant and operator in all sessions to ensure blinding and adherence to the protocol and to record the outcome of each test. OUTCOME: The presence or absence of an allergy according to the standard protocol for electrodermal testing. RESULTS: All the non-atopic participants completed all 3 testing sessions (810 individual tests); 774 (95.5%) of the individual tests conducted on the atopic participants complied with the testing protocol. The results of the electrodermal tests did not correlate with those of the skin prick tests. Electrodermal testing could not distinguish between atopic and non-atopic participants. No operator of the Vegatest device was better than any other, and no single participant's atopic status was consistently correctly diagnosed. CONCLUSION: Electrodermal testing cannot be used to diagnose environmental allergies.

Adult↗

Validity of a novel biopsy urease test (HUT) and a simplified 13C-urea breath test for diagnosis of Helicobacter pylori infection and estimation of the severity of gastritis.

This prospective study was designed to validate a novel biopsy urease test as well as a simplified 13C-urea breath test for the detection of Helicobacter pylori. In addition, the hypothesis was tested that both the reaction velocity of the urease test and the 13CO2 excess of the urea breath test may allow a prediction of the severity of gastritis. Seventy dyspeptic patients with unknown H. pylori status were included. The H. pylori status was assessed by means of culture and histology after Warthin and Starry stain. One antral and one body biopsy specimen were separately analyzed by the novel biopsy urease test (HUT). Also, a 13C-urea breath test using 75 mg 13C-labelled urea and orange juice as test meal was performed in all patients. Forty-seven patients (67%) were H. pylori positive as judged from histology and culture. In 46 patients, H. pylori infection was also detected by the novel biopsy urease test and by the urea breath test as well (sensitivity 97.9%). False-positive results were not observed by either method (specificity 100%). Both the reaction velocity of the urease test and the 13CO2 excess of the breath test significantly correlated with H. pylori density and grade and activity of gastritis. The determination coefficients, however, indicated that both methods allow a reliable prediction of the severity of gastritis only in about 40-50% of the patients. In conclusion, the novel biopsy urease test and the simplified 13C-urea breath test proved to be highly accurate in diagnosing H. pylori infection. Despite a significant correlation, neither the reaction velocity of the urease test nor the 13CO2 excess of the breath test are clinically useful for the prediction of the severity of gastritis.

Adolescent↗