PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “AORTIC DISEASES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Three-dimensional imaging in aortic disease by lighthouse transesophageal echocardiography using intravascular ultrasound catheters. Comparison to three-dimensional transesophageal echocardiography and three-dimensional intra-aortic ultrasound imaging.

Two-dimensional (2D) transesophageal echocardiography (TEE) and 2D intravascular ultrasound (IVUS) imaging face their greatest limitation in visualizing aortic disease in patients. With the aid of three-dimensional (3D) image reconstruction, TEE and IVUS can potentially overcome this limitation but still provide only limited spatial appreciation in aortic disease because 3D imaging of the thoracic aorta requires a broader spatial visualization of the mediastinum than provided by both techniques. Moreover, for timely decision making about aortic disease TEE is limited by a large probe, which requires sedation. Therefore, we developed an approach called 3D lighthouse transesophageal echocardiography (LTEE) using a thin intravascular ultrasound catheter, which provides a full circumferential (360 degree) image and requires no sedation. The purpose of this study was to compare the feasibility and accuracy of 3D TEE, 3D IVUS, and 3D LTEE for obtaining spatial visualization of the thoracic aorta to detect aortic diseases in patients. 3D image datasets were obtained for 3D LTEE by a manual pullback of a 3.3 mm thick, 10 MHz intravascular ultrasound catheter positioned in the esophagus; for 3D TEE using a conventional 15 mm thick probe; and for 3D IVUS using a 2.6 mm thick, 20 MHz intravascular ultrasound catheter. In 12 consecutive patients, three with aortic dissection (two with type III, one with type I) and 11 with suspected artherosclerosis, we analyzed and compared spatial visualization of the thoracic aorta, 3D image quality, patient discomfort, and study time. Providing a 3D dataset of 360-degree tomographic images of the mediastinum, 3D LTEE was the only approach that allowed broad spatial visualization of the aortic arch (9 of 12 patients) with the detection of aortic dissection or atherosclerotic plaques. Spatial visualization of the aortic arch by 3D TEE was incomplete because of the relatively narrow 90-degree image sector. However, in other segments 3D image quality by 3D TEE was superior to 3D LTEE and 3D IVUS. Because of the thin catheter, patient discomfort (p < 0.0001) and examination time (p = 0.015) were significantly less for 3D LTEE compared with 3D TEE. 3D LTEE is a promising new technique for 3D imaging of the thoracic aorta and detection of aortic disease with improved spatial visualization and reduced patient discomfort compared with 3D TEE and 3D IVUS.

Aortic Dissection↗

Aortic arch aneurysm. A sentinel of extensive aortic disease requiring subtotal and total aortic replacement.

Aneurysm of the thoracic aorta is a serious form of disease because it may be extensive or associated with a more distant aneurysm. This manifestation occurs in about one-third of the cases. The actuarial 5-year survival of nontreated patients is only 13% with many patients dying from aortic rupture. The 5-year survival of our patients with aneurysm of the descending thoracic aorta treated by graft replacement is 58% with the two most common causes of late death being myocardial infarction and rupture of another aortic aneurysm. Effective treatment consists of initial total aortic examination, continued follow-up examination, and total replacement of disease. Aneurysmal disease that involves the entire aortic arch is especially prone to extensive involvement because it is due to diffuse aortic dissection or medial degenerative disease in most cases. The latter is most common, being present in 63 of our 81 patients requiring total arch replacement. The disease was extensive in all cases with degenerative medial disease and required extensive graft replacement. In fact, the entire thoracic aorta was involved in ten, the entire thoracic aorta and substantial segments of abdominal aorta in ten, and the entire aorta in 12 patients. Most of these patients were women (84%) over 65 years of age (63%) or older, ten (37%) were over 70 years. Associated pulmonary disease was frequent, aortic valvular insufficiency was present in 12 (38%), and symptoms were present in most. Treatment consisted of removing the disease when possible in stages, the arch in one and the remaining disease in another with the sequence and interval depending upon indications and condition of the patient. A total of 53 operations were performed in these 32 patients, the arch replaced in 29, the descending thoracic aorta in eight, and the thoracoabdominal aortic segment in 16 patients. All of the disease was replaced in 21, including the entire aorta in eight and incompletely replaced in 11 patients. Sixteen (76%) of the former are still alive 4 months to 6 1/3 years. Six (55%) of those in whom operation was limited to replacement of the symptomatic aortic segment because of limited risk are still alive. Of the ten deaths occurring during the study period, four (40%) and perhaps five (50%) were due to natural rupture of unresected disease which indicates its progressive nature and suggests the need for aggressive surgical treatment.

Adult↗

[Change of paradigms in the surgical treatment of complex thoracic aortic disease].

One of the main issues in complex thoracic aortic disease, requiring the replacement of the ascending aorta, the entire aortic arch and the descending aorta, is the vast amount of surgery necessary to cure the patient. Though one-stage repair is feasible by a clamshell thoracotomy, the associated surgical trauma and perioperative morbidity limit this approach to younger patients only. Classic surgical repair consist of a two-stage strategy, whereby, in the first step, the ascending aorta and the aortic arch are replaced via a midline sternotomy. In the second step, via a lateral thoracotomy, the descending aorta is replaced. The two stages may sum up to a mortality of 20%; furthermore, the waiting period between the stages is associated with a mortality rate of 10% of its own. Additionally, the two-stage strategy has an inherent limitation, due to the comorbidity and advanced age of the majority of patients. Therefore, the second stage cannot be offered to up to 30% of patients. New developments and improvements in aortic surgery were introduced to overcome these shortcomings and to simplify the surgical repair. The "elephant trunk" principle, introduced by Borst et al. in 1983, was an important step to facilitate surgical repair, but still required the second step. With the introduction of endovascular repair of thoracic aortic disease with stent grafts implanted retrograde via the femoral artery, new therapeutic concepts emerged. In the late 1990s, two Japanese groups reported first trials to stabilize the free-floating "elephant trunk" prosthesis by implantation of nitinol stent grafts into the vascular graft. The applied devices were purely custom-made and nonstandardized. The availability of industrially made and CE-marked stent-graft devices raised the possibility to apply them in open aortic arch surgery. The experience with stent-graft devices implanted antegrade into the descending aorta (Medtronic Talent) was reported first by the Essen and the Vienna group. The experience gained with these devices revealed the limitations of the devices designed for pure retrograde aortic delivery. This required a complete redesign and new construction of the stent graft itself as well as the introducer system. In a preliminary series of 14 patients the required stent-graft properties were presented in detail and resulted in the first industrially manufactured standardized and CE-marked Hybrid stent graft (Essen 1 prosthesis, E-vita Open, Jotec), especially made for antegrade open stent grafting of the descending aorta. This device consists of a stent graft with an integrated Dacron vascular prosthesis, enabling for direct and continuous aortic arch replacement after stent grafting of the descending aorta. From 01/2005 to 03/2006, this hybrid prosthesis was implanted in 16 patients (one aneurysm and 15 aortic dissections). In all cases, the underlying pathology within the thoracic aspect of the aorta could be excluded in a one-stage approach. In case of aortic dissection, thrombosis of the false lumen was detectable by transesophageal echocardiography already at the end of surgery. Though long-term results using this new method are not yet available, the initial promising results postoperatively are encouraging toward true one-stage repair by combining classic aortic surgery with open antegrade stent grafting utilizing the newly designed hybrid prosthesis. While surgical trauma is markedly reduced, this treatment option can be offered to elderly patients as well.

Adult↗

Increased ICAM-1 expression in aortic disease.

PURPOSE: In this investigation we evaluated the expression of vascular adhesion molecules: intercellular adhesion molecule-1 (ICAM-1), E-selectin, and vascular cell adhesion molecule-1 (VCAM-1) in normal and diseased aorta. METHODS: Aortic tissue was obtained during operations for abdominal aortic aneurysms (AAA) (inflammatory, n = 3, noninflammatory, n = 6), aortic occlusive disease (AOD) (n = 6), or from fresh cadavers (NL) (n = 5). The tissue was stained with the avidin-biotin complex with the following primary antibodies: anti-ICAM-1-AA6, anti-E-selectin-BB11, and anti-VCAM-1-4B9. The slides were assigned an inflammatory score of 0 to 3, and the percentage of each cell type staining, 0% to 100%. RESULTS: A trend towards a higher inflammatory score was found in the vessel wall in AAA (2.4 +/- 1.8) as compared with AOD (1 +/- 0.37) or NL (0.2 +/- 0.2). There was no statistical difference. A significant elevation in ICAM-1 expression (p < or = 0.06), however, was demonstrated in the adventitial endothelial cells of AAA (85.8% +/- 7.8%), and AOD (80.0% +/- 11.1%), as compared with NL (30.8% +/- 12.2%). Both E-selectin and VCAM-1 were expressed in all groups, but no statistical difference was demonstrated. CONCLUSIONS: Patients with AAA and AOD display a significant upregulation of the expression of ICAM-1, suggesting a role for this protein in the initiation or maintenance of degenerative aortic diseases.

Aged↗

[Usefulness of transesophageal echocardiography in thoracic aortic disease: comparison with computed tomography and angiography].

To evaluate the usefulness of transesophageal echocardiography in thoracic aortic disease, transesophageal echocardiography was performed in 11 patients with thoracic aortic disease (true aortic aneurysm in two patients, aortic dissection in nine patients). Findings obtained by transesophageal echocardiography were compared with those obtained by computed tomography (nine patients) and angiography (six patients). Results were as follows: 1. True aortic aneurysm: Although transesophageal echocardiography and computed tomography could evaluate the size of the aorta and detect mural thrombus, angiography underestimated degree of aortic dilatation because of the presence of mural thrombus. 2. Aortic dissection: Although computed tomography could not differentiate thrombus in the false lumen from mural thrombus in two patients, transesophageal echocardiography could discriminate those two easily in one patient from properties and motion of the intimal flap, and flow information in the false lumen. Angiography could not evaluate the range of dissection in any patients with thrombus in the false lumen. With transesophageal echocardiography we could detect the entry in all six patients with aortic dissection of DeBakey type III except 1 patient with aortic dissection of DeBakey type I. Transesophageal echocardiography could obtain real-time image of most of the aorta except for a part of the ascending aorta. Therefore, transesophageal echocardiography was useful for diagnosing thoracic aortic disease and distinguishing between true aortic aneurysm and aortic dissection.

Aged↗

Possible role of cytomegalovirus in the pathogenesis of inflammatory aortic diseases: a preliminary report.

To search for possible evidence of a relationship between human cytomegalovirus and aortic diseases, we examined 41 aortic lesions excised at surgery and 16 aortic tissues obtained at autopsy for the presence of cytomegalovirus DNA, by use of polymerase chain reaction. Cytomegalovirus DNA was present in seven (88%) of eight lesions of inflammatory aortic diseases with periaortic fibrosis, five of six inflammatory aneurysms, and all of two aortic occlusive lesions with inflammation. Cytomegalovirus DNA was detected in 20 (61%) of 33 atherosclerotic aneurysms, whereas it was detected in only five (31%) of 16 autopsy samples that showed neither inflammation nor atherosclerosis. Thus the possibility that cytomegalovirus may play a role in the pathogenesis of inflammatory aortic diseases warrants further attention.

Adult↗

Noninvasive evaluation of suspected thoracic aortic disease by contrast-enhanced computed tomography.

Traditionally, suspected thoracic aortic disease has been evaluated by aortography, which has associated risks because it is invasive. With the introduction of computed tomography (CT), a noninvasive alternative has become available. In the present retrospective study, the potential clinical value of CT in providing correct diagnoses and pertinent information required for current therapies is evaluated. For this purpose, results of CT in 200 patients examined for suspected thoracic aortic disease were compared with "hard" (surgical and autopsy findings) or "soft" (follow-up clinical information) evidence of the true diagnoses. Aortographic results, available in 51 patients (26%), were also compared with available clinical evidence. Excluding inadequate examinations, the diagnostic accuracy of the independently and blindly interpreted results of CT and aortography were similar (86% and 87%, respectively) in patients with true diagnoses confirmed by hard evidence. When patients evaluated for aortic damage from acute blunt chest trauma were also excluded, the accuracy was 90% for CT and 86% for aortography. Specifically, CT was 83% and 67% accurate in proved (i.e., confirmed by hard evidence) type A and type B dissections, respectively (75% for both type A and B by aortography). In the 183 patients suspected of having thoracic aortic disease not attributable to acute blunt chest trauma and with follow-up information, 91% would have been managed appropriately based on their CT evaluation alone. In the subset of patients who underwent aortographic evaluation as well, 91% would have been managed appropriately based on aortography alone. The accuracy for combined CT and aortography was 94%.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Dissection↗

The short-to-midterm results of endovascular stent grafting for acute thoracic aortic diseases in Chinese patients.

OBJECTIVE: To review the results of endovascular treatment of acute thoracic aortic diseases in a group of Chinese patients. DESIGN: Retrospective study. SETTING: A tertiary referral hospital with a cardiothoracic surgery service. PATIENTS: All 15 patients presenting with acute thoracic aortic diseases between September 2001 and October 2005 inclusive, of whom eight had traumatic rupture, four had complicated acute dissections, two had mycotic aneurysms, and one an aneurysm with an aortobronchial fistula. INTERVENTIONS: Thoracic aortic stent grafting. MAIN OUTCOME MEASURES: Immediate success, 6-month and 1-year survival rates. RESULTS: The median follow-up period was 20.6 months (range, 0-50.1 months). Stent grafts were deployed with immediate success in all patients. Two patients had ancillary bypass surgery for the supra-aortic branches. There were two in-hospital deaths. Four sustained access artery injury and needed graft repair. Computed tomography at 1 month showed complete thrombosis of the aneurysmal lumen or the thoracic aortic false lumen in 12 of 13 survivors. Computed tomography at 6 months showed complete thrombosis of the aneurysmal lumen or the false lumen in nine of 10 patients due for follow-up. Both 6-month and 1-year survival rates were 87%. CONCLUSIONS: Thoracic aortic stent grafting for acute thoracic aortic disease is feasible and has a high success rate, with good short-to-midterm results. However, the large size of the stent graft introducer set imposes a high risk of access artery injury, for which further improvements are necessary.

Aortic Dissection↗

Thoracic aortic endografting is the treatment of choice for elderly patients with thoracic aortic disease.

OBJECTIVE: To assess the effect of age on outcomes following thoracic aortic endografting. SUMMARY BACKGROUND DATA: Endograft therapy for thoracic aortic disease is rapidly evolving. This therapy is less invasive, and elderly patients with significant medical comorbidities are more frequently referred for endografting. We hypothesized that elderly patients over the age of 75 have worse outcomes after thoracic endografting than patients under the age of 75. METHODS: We retrospectively reviewed the charts of the first 42 patients who underwent endografting for thoracic aortic pathology. Charts were reviewed for demographics, comorbid conditions, perioperative complications and death, endoleaks, and results at 3, 6, and 12 months. Preexisting medical conditions were also evaluated to determine if any patient characteristics were associated with adverse outcomes. Perioperative morbidity included cardiac, pulmonary, renal, hemorrhagic, and neurologic (stroke and spinal cord injury) complications. RESULTS: Twenty-four patients were under the age of 75, and 18 patients were 75 or older. Baseline demographics and comorbidities were similar between the 2 groups. There were no differences in operative time, length of stay, perioperative mortality, or the incidence of significant complications between the 2 age groups. Gender, however, was associated with a statistically significant difference between the occurrence of complications, with more women experiencing complications than men (P = 0.026, relative risk = 2.36). One patient (age >75 years) in the entire cohort of 42 (2.4%) suffered a spinal cord injury. At 3 months, endoleaks were more common in the older age group (P = 0.059). CONCLUSION: Endograft therapy for thoracic aortic disease can be performed safely in elderly patients with no significant increase in perioperative morbidity or mortality compared with younger patients. Female gender is associated with a higher likelihood of perioperative complications, regardless of age. The overall incidence of spinal cord injury is very low. Endograft therapy, when anatomically possible, is the treatment of choice for thoracic aortic disease in elderly patients.

Adult↗

Differential expression of prostaglandin E2 and interleukin-6 in occlusive and aneurysmal aortic disease.

BACKGROUND: Both aortoiliac occlusive disease (AIOD) and abdominal aortic aneurysm disease (AAA) are traditionally considered degenerative conditions that are caused by atherosclerosis. Although it is becoming apparent that the pathophysiology of each condition has its own determinants, inflammation is thought to play a role in each. The purpose of this study was to analyze the inflammatory cytokines interleukin-6 (IL-6) and prostaglandin E2 (PGE2) in aortic disease and compare AAA with AIOD, as well as to compare both with normal aorta. METHODS: Aortic tissue was harvested at the time of aortic reconstructive surgery for AAA (n = 13) and AIOD (n = 14) or at time of organ harvest for normal (n = 16) aortic specimens. Whole organ cultures were immediately established, and the culture medium was collected after 72 hours. An enzyme-linked immunosorbent assay was used to assay for PGE2 and a lymphoproliferative assay was used to quantitate IL-6. Statistical analysis was performed using paired 2-tail t tests. RESULTS: Normal aorta expressed much less PGE2 (384 +/- 67 ng/mL) than either AAA (11,093 +/- 7,411 ng/mL) (P < .001) or AIOD (13, 719 +/- 3,355 ng/mL) (P < .002). However there was no statistically significant difference in PGE2 expression between the AAA and AIOD groups (P = . 44). The IL-6 assay also showed that normal aorta had very little expression (1,861 +/- 334 U/mL) compared with either AAA (14,329 +/- 4,159 U/mL) (P = . 02) or AIOD (39,805 +/- 8,426) (P < .001). Comparison between AAA and AIOD revealed significantly higher expression of IL-6 by the AIOD cultures (P = .03). CONCLUSIONS: AAA and AIOD are associated with increased expression of the proinflammatory cytokines PGE2 and IL-6. However, AIOD is associated with a much higher level of IL-6 expression than is AAA, although the level of PGE2 expression is the same. This differential expression of IL-6 may help explain the pathogenesis of these 2 distinct aortic diseases.

Aorta, Abdominal↗

[Treatment of the infrequent complications after stent graft placement for aortic disease].

OBJECTIVE: To explore the infrequent complications and treatment after endoluminal stent graft implantation for aortic diseases. METHODS: Review of the characters and complications for five cases of aortic diseases by stent graft implantation. RESULTS: The complications of 4 cases have been relieved by operation or re-stent implantation, 1 case was died. CONCLUSION: The complications are difficult to forecast for stent graft placement in aortic diseases, the surgeon should be well practiced in surgical and interventional technique, so as to treat the complications in time.

Aged↗

Combined open and endovascular treatment of complex aortic disease.

The purpose of this article is to report whether combined open and endovascular treatment could be applied in patients with complex aortic disease. A retrospective study including four patients with complex aortic disease was undertaken. In all patients, extra-anatomic bypass to the visceral arteries was made through a laparotomy while the aortic lesion was repaired by stent grafting. One patient died on the first postoperative day and another died 3 months after treatment from a myocardial infarction. The other two patients were alive 13 and 34 months after treatment, respectively. However, a patient treated for a ruptured thoracoabdominal type 2 aneurysm on the basis of a dissection suffers from postoperative paraplegia. The combination of open surgery with extra-anatomic bypass to visceral arteries and stent grafting could be an option for the treatment of patients with complex aortic disease, especially in high-risk cases in which more extensive open surgery is contraindicated.

Aged↗

Simultaneous abdominal aortic replacement and thoracic stent-graft placement for multilevel aortic disease.

PURPOSE: Patients with aneurysmal disease involving both the descending thoracic and abdominal aorta have historically required simultaneous or sequential conventional operations, but the morbidity rate is high with either approach in these patients, who often exhibit coexisting cardiopulmonary disease. Transluminally placed endovascular grafts have recently been developed for repair of aortic aneurysms, and we have implemented these techniques to eliminate the need for a thoracotomy in patients with multilevel aortic disease. METHODS: Since January 1994, 18 patients have undergone conventional abdominal aortic replacement with endovascular stent-graft placement into the descending thoracic aorta under fluoroscopic guidance through a 10 mm Dacron side limb off the abdominal graft. Abdominal aortic replacement required a tube graft in eight patients and bifurcated grafts in 10 patients. Thoracic stent-grafts (custom fabricated, woven Dacron covered, self-expandable stents) averaged 12.2 +/- 4.2 cm (mean +/- SD) in length. RESULTS: One patient died, resulting in a hospital mortality rate of 6%. No patients required further surgical intervention to treat their aortic disease. Seventeen patients (94%) are currently well 14 +/- 8 months after surgery (range, 3 to 29 months) with completely excluded thoracic aortic disease, no stent migration, and no change in stent configuration documented by serial radiologic examinations. CONCLUSIONS: Simultaneous abdominal aortic replacement and deployment of a thoracic stent-graft can safely exclude multilevel aortic aneurysmal disease and may be a valuable treatment option for these otherwise high-risk patients.

Aged↗

C-reactive protein and mortality in patients with acute aortic disease.

OBJECTIVE: The association of acute-phase reaction and outcome of patients with acute vascular diseases is controversial. The prognostic value of admission C-reactive protein (CRP) in patients with acute aortic aneurysm or dissection has not yet been investigated. DESIGN AND SETTING: Cohort study including 255 consecutive patients from an aneurysm registry with symptomatic thoracic or abdominal aortic aneurysm and/or dissection in an emergency department of a tertiary care university hospital. PATIENTS: Patients were included who had symptoms of aortic disease admitted between 1 January 1992 and 31 November 1998 and were followed up until 31 December 1999 for survival. MEASUREMENTS: Admission CRP (mg/dl) levels were categorized in quartiles: quartile 1, less than 0.5; quartile 2, 0.50-1.30; quartile 3, 1.31-6.30; quartile 4, higher than 6.30. Each group contained about 60 patients. RESULTS: Cumulative mortality 1, 3, and 6 months after presentation was 32%, 37%, and 40%, respectively. Increased CRP levels were independently associated with mortality, adjusted for age, sex, hemodynamic shock, mechanical ventilation, coronary artery disease, aortic rupture, hemoglobin, diabetes, and treatment strategy (surgery vs. conservative). Hazard ratios in patients with CRP levels in quartiles 2-4 compared to quartile 1 were 0.7, 1.8, and 2.6, respectively. CONCLUSIONS: Elevated admission CRP values in patients with symptomatic aortic aneurysm/dissection were independently associated with poor prognosis. CRP levels higher than 6.3 mg/dl indicate a high risk for short-term mortality.

Acute-Phase Reaction↗

Operative management of coexistent aortic disease and horseshoe kidney.

The presence of horseshoe kidney in conjunction with abdominal aortic disease significantly increases the technical difficulty of aortic reconstruction. Preservation of the renal blood supply and collecting system during the surgical procedure is the goal of operative management. The pertinent issues that remain unresolved include the need for specific preoperative studies, the optimal operative approach and the safety of isthmus division. From 1979 to 1994 eight patients with horseshoe kidney underwent operative intervention for aortic disease. Five men and three women who had a mean age of 66 years underwent seven reconstructions for aneurysmal disease and one for aortoiliac occlusive disease. All operations were elective and the transperitoneal approach was used in all cases. In the patients with aneurysmal disease the mean maximal aortic diameter was 7.3 cm. The mean preoperative serum creatinine value was 1.1 mg/dl. Preoperative identification of horseshoe kidney was accomplished in all seven patients with aneurysmal disease but not in the patient with occlusive disease. The anomaly was correctly identified by CT scan in seven of seven (100%) patients, arteriography in two of eight (25%) patients, ultrasonography in two of seven (29%) patients, and renal scan in one patient. In the three patients who underwent intravenous pyelography (IVP) the caliceal system was demonstrated to be completely separate from the isthmus. Renal artery anomalies were present in six (75%) patients; in three (50%) these anomalies could be not visualized on the preoperative arteriogram. Renal revascularization was accomplished by a variety of techniques, including reimplantation of multiple (one patient) and single (four patients) renal arteries and branch grafting to an individual renal artery (one patient).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

[Experience on transplantation of auto-pulmonary graft treating with congenital aortic disease].

OBJECTIVE: To summarize the experience on auto-pulmonary transplantation (Ross procedure) treating with congenital aortic disease. METHODS: From October 1994 to November 2003, 20 cases of Ross procedure were performed to treat with congenital aortic disease, Male: 15 cases; Female: 5 cases; age: 25 years; DIAGNOSIS: congenital heart disease (CHD), aortic abnormalities: 12 cases; aortic valve prolapse: 5 cases; aortic valve hypogenesis: 3 cases; combined with subacute bacterial endocarditis (SBE): 4 cases, and ventricle septal defect (VSD): 2 cases; UCG showed aortic stenosis(AS) and/or aortic insufficience (AI) (moderate to severe), Left ventricle diastole diameter (LVDD): (60.51 +/- 11.87) mm, the grade pressure across aortic valve: (27.04 +/- 6.80) mmHg, heart function (NYHA): Class II: 13 cases; Class III: 3 cases; all cases were performed under CPB and moderate hypothermia, the operation procedure was following: (1) taking off auto-pulmonary artery valve; (2) removing dysfunctional aortic valve and auto-transplantation of pulmonary valve on aortic root; (3) putting a pulmonary homograft to rebuild right ventricular outflow tract. RESULTS: The mortality was 0 during stay at hospital, aortic valve function were all normal, LVDD decreased significantly (t = 3.4007, P = 0.0008), the grade pressure across aortic valve was in normal limitation, (6.8 +/- 0.19) mmHg. Follow-up showed heart function was in Class I (NYHA), aortic and pulmonary valve function was very well. CONCLUSION: Ross procedure is a kind of effective alterative operation for treating with congenital aortic valve disease, with good short and middle term results.

Adolescent↗

[Emergency endovascular treatment of acute aortic diseases].

PURPOSE: To investigate the safety and efficacy of emergency treatment of acute aortic diseases with endovascular stent grafts. METHODS: In 11 patients (median age 55 years, range 18 - 85) with acute complications of descending aortic diseases endovascular emergency treatment was performed: traumatic aortic rupture (n = 4), penetrating ulcer with aortobronchial fistula or hematothorax (n = 4), acute type B dissection (n = 2, one with penetration, one with subacute mesenteric ischemia), and symptomatic aneurysm of the thoracic aorta (n = 1) with pain and diameter progression. 15 stent grafts were implanted (Talent n = 11, Vanguard/Stentor n = 4). Stent extension was necessary in 4 cases. In 2 cases graft extension was done during the first procedure (due to distal migration and due to the total length of the aortic aneurysm). In 2 cases graft extension was performed 5 days (due to a new aortic ulcer at the proximal stent struts) and 5 months after the initial procedure (recurrent aortobronchial fistula due to aneurysm progression). 14 of 15 implantations required general anesthesia, one symptomatic thoracic aneurysm was performed in local anesthesia and sedation. RESULTS: 14 of 15 graft procedures were performed using the femoral or iliac approach. One procedure required aortofemoral bypass grafting due to extensive arteriosclerotic stenosis and the stent graft was inserted via the bypass graft. The orifice of the subclavian artery was crossed with bare stent struts in 4 cases without neurological complications. Median follow-up is 27 months (range 6 to 72 months). In traumatic aortic ruptures, immediate sealing of bleeding was achieved and follow-up is inconspicuous at a maximum of 72 months. In cases of aortobronchial fistulas, follow-up is satisfactory (maximum 72 months) despite the necessity for reintervention and graft extension. In one acute type B dissection retrograde dissection of the aortic arch occurred during stent release with stable disease during follow-up without neurological complications. In one type B dissection with mesenteric ischemia the mesenteric blood flow was restored. A second look operation confirmed pulsatile flow in the mesenteric trunk but a total necrosis of the small intestine and the patient consequently died. CONCLUSION: Endovascular treatment is safe and effective for emergency treatment of life-threatening complications in selected acute aortic syndromes. Mid-term results are encouraging, however, regular follow-up is mandatory to recognize late complications of the stent graft.

Acute Disease↗