PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Bone Plates”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Fixed mandibular complete denture prostheses supported by mandibular staple bone plate implant.

The staple bone plate implant has been used to stabilize and retain an mandibular overdenture. This implant-with-pin configuration, with four pins penetrating the bone and mucosa, was used to support a mandibular fixed complete denture. The prosthesis was completely implant supported. All of the occlusal loads were directed to the bone through the implant pins. Results for six patients were reported. The implant and the prosthesis were well tolerated.

Adult↗

Survey of experiences with the mandibular staple bone plate.

The mandibular staple bone plate has been used to reconstruct the atrophic or deformed mandible in more than 400 cases. A survey was undertaken to evaluate those cases; results indicate that 90% of patients have satisfactory function.

Accidents, Traffic↗

The electron microscope appearance of the subchondral bone plate in the human femoral head in osteoarthritis and osteoporosis.

The subchondral bone plate supports the articular cartilage in diarthrodial joints. It has a significant mechanical function in transmitting loads from the cartilage into the underlying cancellous bone and has been implicated in the destruction of cartilage in osteoarthritis (OA) and its sparing in osteoporosis (OP), but little is known of its composition, structure or material properties. This study investigated the microscopic appearance and mineral composition of the subchondral bone plate in femoral heads from patients with OA or OP to determine how these correspond to changes in composition and stiffness found in other studies. Freeze-fractured full-depth samples of the subchondral bone plate from the femoral heads of patients with osteoarthritis, osteoporosis or a matched control group were examined using back scattered and secondary emission scanning electron microscopy. Other samples were embedded and polished and examined using back-scattered electron microscopy and electron probe microanalysis. The appearances of the samples from the normal and osteoporotic patients were very similar, with the subchondral bone plate overlayed by a layer of calcified cartilage. Osteoporotic samples presented a more uniform fracture surface and the relative thicknesses of the layers appeared to be different. In contrast, the OA bone plate appeared to be porous and have a much more textured surface. There were occasional sites of microtrabecular bone formation between the trabeculae of the underlying cancellous bone, which were not seen in the other groups, and more numerous osteoclast resorption pits. The calcified cartilage layer was almost absent and the bone plate was apparently thickened. The appearance of the osteoarthritic subchondral bone plate was, therefore, considerably different from both the normal and the osteoporotic, strongly indicative of abnormal cellular activity.

Aged↗

[Use of bone plates in external osteosynthesis].

The author applied the bone plate for external osteosynthesis in 6 patients. Three of them had open fractures of 2nd grade in the area of shin, one patient in the area of forearm. In 2 patients there occurred unstable pseudoarthrosis of shin with significantly trophically changed soft tissue covering. On the shin he always two broad bone plates on the anteromedial aspect of the shin, and namely in the V-configuration. For the increase of the stability of the assemblage he used the interconnection of two broad plates by one or two narrow moulded plates the subsequent modification of which allowed to apply the rubber traction for the training of the sole. He had not met with any reaction to the inserted screws. In unstable pseudoarthrosis he used the combination of the clamp telescopic fixator and a broad bone plate and namely on the anteromedial aspect of the shin. He considers the combination of these methods perspective for the application of clamp fixators in unstable fractures and pseudoarthrosis of tibia. By means of the application of bone plates for external fixation we can achieve adequate fixation also in case of short fragments in both the proximal and distal parts of tibia and thus avoid the application of a fixator over the adjacent joint. In 3 patients he has succeeded in ensuring full healing with full range of mation in the adjacent joints, in 2 patients the bone consolidation is proceeding successfully and in a short time it will be possible to remove the fixators. The application of this method on the forearm had not ensured the healing. It was necessary to remove the fixator due to the intermittent inflammatory reaction around the screws. The bone consolidation was then achieved by spongioplasty. The method presented does not allow secondary correction of fragments, its application is limited.

Adult↗

A multicenter retrospective review of the mandibular staple bone plate.

The mandibular staple bone plate, herein referred to as the staple, has been used as a reconstructive device to improve mandibular function for more than a decade. This report presents the clinical and radiographic findings of a retrospective survey of 160 patients from three separate practices over an eight-year period (1975-1983). The criteria established at the 1978 NIH-Harvard Consensus Development Conference on Dental Implants were used to evaluate results. The study also evaluates experiences with other procedures used in conjunction with the staple.

Bone Plates↗

Poly(L-lactide) bone plates and screws for internal fixation of mandibular swing osteotomies.

This study evaluated bone healing after mandibular swing osteotomies fixed with biodegradable poly(L-lactide) (PLLA) bone plates in four patients. A step osteotomy treated with two PLLA bone plates (n=3), and a straight osteotomy treated with one PLLA bone plate (n=1) were performed. Bone healing was uneventful in all patients; only in the patient with the straight osteotomy was callus observed. After 5.5 years, radiologic changes at the site of implantation were observed in the remaining patient. Histologic examination revealed a nonspecific foreign-body reaction on highly crystalline PLLA remnants which were still present. It is concluded that the PLLA bone plates provided enough strength to enable undisturbed bone healing. The long-term degradation results are comparable with those of other studies on as-polymerized PLLA implants.

Biodegradation, Environmental↗

Bone strain following application of a rigid bone plate: an in vitro study in human mandibles.

This study evaluated the effect of a bone plate on mandibular bone strain patterns during static loading. A stainless steel bone plate was unilaterally attached to five human mandibles, which were then subjected to static loads of 60 kiloponds. Four strain gauges attached to the cortical bone were used to measure the strain patterns within the mandible both before and after the bone plate was attached. The results showed that statistically significant alterations in the strain patterns occurred following plating of the mandible. The mandible with the plate attached became more stiff, presumably due to the difference in modulus of elasticity between the plate and the bone. However, this increase in stiffness was relatively small when compared with both total strain under load and strain produced by tightening of the bone screws.

Adult↗

Stress shielding reduced by a silicon plate-bone interface. A canine experiment.

Effects of modifying the plate-bone interface with Silastic were tested. The experimental plate, i.e., a conventional plate with a Silastic backing was compared with the standard plate. In vitro four-point bending tests showed similar strain per load behavior in the experimental and standard plate models. In vitro plate-bone contact was greater and interface pressure was lower for the experimental as compared with the standard plate. An in vivo implant study was conducted where the plates were tested on intact canine femurs. At 27 weeks postimplantation, there was less porosity and remodeling in the haversian envelope of bone plated with a Silastic interface.

Animals↗

Meniscectomy leads to an early increase in subchondral bone plate thickness in the rabbit knee.

We evaluated morphological changes in the tibial bone after meniscectomy in a rabbit model. 15 rabbits subjected to a medial meniscectomy in the right knee and a sham-operation in the left. Histomorphometric parameters were evaluated in the subchondral bone plate and the underlying trabecular bone, 13, 25 and 40 weeks after surgery. 5 rabbits were used as unoperated controls. Meniscectomized knees had a thicker subchondral bone plate than sham-operated contralateral ones in 13 of the 15 rabbits (p = 0.01), but the trabecular bone showed no morphological differences. The meniscectomized knees of these rabbits developed mild osteoarthrosis, described elsewhere, which may have been partly due to a change in the mechanical properties of the thickened subchondral bone plate. Our findings suggest that the first bony response after meniscectomy occurs in the subchondral bone plate rather than in the trabecular bone.

Animals↗

Simultaneous cortex bone plate graft with particulate marrow and cancellous bone for reliable closure of palatal fistulae associated with cleft deformities.

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of simultaneous cortex bone plate (CBP) graft with particulate marrow and cancellous bone (PMCB) graft for reliable closure of palatal fistulae associated with alveolar clefts. DESIGN: Following standard secondary bone graft preparation of the cleft site, CBP harvested from the medial iliac crest was inserted into the palatal deficiency. This was followed by suturing the palatal mucosa. PMCB was then packed between the cortical bone and the reconstructed nasal floor. SETTING: Ten consecutive patients with palatal fistula were operated on at Tokyo Medical and Dental University Hospital from 1998 to 2000. Primary palatal repair was performed in 7 out of 10 patients at our center and in 3 out of 10 patients at other hospitals. PATIENTS: Ten patients (6 boys and men, 4 girls and women) with a palatal fistula associated with an alveolar cleft were studied. Ages ranged from 12 to 26 years. INTERVENTIONS: All patients underwent simultaneous CBP graft with PMCB graft for closure of palatal fistula under general anesthesia. RESULTS: Complete closure of palatal fistulae were obtained in 8 out of 10 cases. A very small asymptomatic fistula remained in one patient. Total necrosis of the labial flap with a residual palatal fistula occurred in one patient. CONCLUSIONS: Simultaneous CBP graft with PMCB graft could be more reliable than PMCB alone for closure of a cleft associated palatal fistula.

Adolescent↗

Fatigue fracture of bone plates.

Of all the possible causes of bone plate failure, by far the most common is failure by fatigue. The effect of the environment and loading regime on the fatigue life is discussed. The use of the corrosion potential for the evaluation of fatigue experiments and the detection of fatigue cracks in explanted plates is described. The authors demonstrate that the surface finish and the possibility of a loss in fatigue strength after plate remodelling are factors that should not be ignored when testing bone plates.

Bone Plates↗

The effect of long-term bone plate application for fixation of radial fractures in dogs.

This study was divided into two phases. In the in vitro phase, a stainless steel bone plate was applied to the cranial surface of the radius in 14 canine limbs. The effect of the presence of a bone plate on bone density analysis using radiographic photodensitometry (RP) was evaluated by comparing the density measurement of the unplated limb to the density measurement of the plated limb. The optical density of the plated bones was 12% greater than that of the unplated bones. This information was used as a correction factor for the in vivo study. In the in vivo phase, 23 dogs with radial and ulnar fractures were examined for complications associated with the long-term application of a stainless steel plate applied to the cranial surface of the radius. In 14 dogs, RP analysis was used to compare the plated limb with the normal, contralateral limb. No significant differences in radial cortical bone density existed between the plated limb and the contralateral limb after taking into account the effect a bone plate had on photodensitometry readings. There was no significant correlation between the change in radial cortical density and the duration of bone plate application, suggesting that a steady state between bone loss and bone production occurs after long-term plate fixation of the fractured canine radius. The majority (87%) of the dogs with a plate applied to the radius greater than 1 year had normal limb usage when standing, walking, or running.

Absorptiometry, Photon↗

Influence of resorbable poly(L-lactide) bone plates and screws on the dose distributions of radiotherapy beams.

Metallic bone plates have been shown to affect radiation in vitro. Although no damage has ever been demonstrated in vivo these plates may cause dose enhancements and shielding of the adjacent tissue. Resorbable high molecular weight as-polymerized poly(L-lactide) (PLLA) bone plates have recently been used for reconstruction in the maxillofacial area. To determine their influence on dose distribution, a 4-hole bone plate and screws of PLLA were exposed to electron and photon beams. A tissue-equivalent phantom of perspex was irradiated and measurements were made with LiF thermoluminescent dosimeters. No significant changes in dose deviations could be determined when the dose distribution in the homogeneous phantom was compared with that of the phantom in which the PLLA material was placed. From this study it can be concluded that the PLLA material can be regarded as tissue-equivalent and can, thus, be safely used for fracture fixation of bone fragments when postoperative irradiation is anticipated.

Bone Plates↗

High strength bioresorbable bone plates: preparation, mechanical properties and in vitro analysis.

Biodegradable bone plates were prepared as semi-interpenetrating networks (SIPN) of crosslinked polypropylene fumarate (PPF) within a host matrix of either poly(lactide-co-glycolide)-85:15 (PLGA) or poly(1-lactide-co-d,l-lactide)-70:30 (PLA) using N-vinylpyrrolidone (NVP), ethylene glycol dimethacrylate (EGDMA), 2-hydroxyethyl methacrylate (HEMA), and methyl methacrylate (MMA) as crosslinking agents. Hydroxyapatite (HAP), an inorganic filler material, was used to further augment mechanical strength. The control crosslinking agent (NVP) was replaced partially and totally with other crosslinking agents. The amount of crosslinking agent lost, the characterization change in the mechanical properties and the dimensional stability of the bone plates after in vitro treatment was calculated. The optimum crosslinking agent was selected on the basis of low in vitro release of NVP from SIPN matrix. Bone plates were then prepared using this crosslinking agent at 5 MPa pressure and at temperatures between 100-140 degrees C to determine if there was any augmentation of mechanical properties in the presence of the crosslinked network. In vitro analysis showed that 90% of the crosslinking agent was lost on plates using NVP as a crosslinking agent. This loss was reduced to 50% when NVP was partially replaced with EGDMA or MMA. EGDMA was determined to be superior because (1) its low release as a crosslinking agent, (2) flexural plate strength of 50-67 MPa, (3) flexural modulus of 7-13 GPa, and (4) manufacturability stiffness of 300-600 N/m. HAP-loading resulted in an additional increase in values of mechanical parameters. Substituting PLGA with PLA in the PPF-SIPN did not show any additional improvement of mechanical properties.

Absorbable Implants↗

Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study.

UNLABELLED: There is uncertainty regarding whether and how the subchondral bone plate should be treated during acetabular preparation for cemented cup fixation in a total hip arthroplasty. We hypothesized that removing the bone plate would improve the cement-bone interface without jeopardizing the initial cup stability, and therefore, be advantageous to long-term cup survival. We randomized 50 patients with primary osteoarthritis into two groups, one for removal and one for retention of the subchondral bone plate. The patients were evaluated during 2 years followup using repeated radiostereometric examinations, analyses of radiolucent lines, and clinical followups. Patient scoring was done using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12, and the Harris hip score. Removal of the subchondral bone plate resulted in a superior cement-bone interface with less development of radiolucent lines. The radiostereometry results showed small migrations in both groups. We found no differences in cup stability between groups, although a difference was observed in rotational behavior with the removal group stabilizing in a slightly vertical position whereas the retention group showed slight but progressive rotation into a more horizontal position. No differences were found during clinical followups. Removing the subchondral bone plate, where possible, improves the cement-bone interface without jeopardizing the stability, implying better long-term cup survival. However, it is a more demanding surgical technique. LEVEL OF EVIDENCE: Therapeutic study, Level I (high quality randomized controlled trial with statistically significant difference or no statistically significant difference but narrow confidence intervals). See the Guidelines for Authors for a complete description of levels of evidence.

Acetabulum↗

Open reduction and bone plate stabilization, compared with closed reduction and external fixation, for treatment of comminuted tibial fractures: 47 cases (1980-1995) in dogs.

OBJECTIVE: To compare open reduction and bone plate fixation with closed reduction and external skeletal fixation as treatment for severely comminuted fractures of the tibia. Limb alignment, fracture reduction, operating time, hospitalization time, postoperative care, time to unrestricted activity, bone healing, complications, and number of surgical procedures were considered. DESIGN: Retrospective case series. ANIMALS: 47 dogs with severely comminuted fractures of the tibia treated with open reduction and bone plate application (22 dogs) or closed reduction and external fixation (25 dogs). PROCEDURE: Medical records of all dogs included in this study were reviewed. Postoperative and follow-up radiographs were evaluated by 2 independent observers. RESULTS: Differences were not found in hospitalization time, time to unrestricted activity, or time to earliest radiographic evidence of bone healing between dogs with fractures treated with a bone plate and dogs with fractures treated with an external fixator. Fractures treated with an external fixator had more caudal malalignment, and fractures treated with a bone plate had more valgus malalignment. Malalignments were determined not to be related to clinical problems. Dogs with fractures treated with an external fixator had shorter surgery times and more recheck examinations. Dogs with fractures treated with a bone plate had more complications. CLINICAL IMPLICATIONS: Open reduction with bone plate fixation and closed reduction with external fixation were both effective for treatment of comminuted tibial fractures. External fixation was associated with shorter surgery time, but dogs required more extensive postoperative care. Bone plate fixation was associated with more complications.

Animals↗

Bone plating in patients with type III osteogenesis imperfecta: results and complications.

The results of bone plating in four children (6 femurs, 2 tibias) with osteogenesis imperfecta type III were analyzed. Average age at time of operation was 44 months. In three of the femurs, multiple platings were performed for a total of 13 bone platings in the eight bones studied. Average time to revision following plating was 27 months. Indications for revision included fracture (6), deformity (3), hardware failure (3), and nonunion (1). Other complications included one case of compartment syndrome. All eight bones were ultimately revised to elongating intramedullary Bailey-Dubow rods. Bone plating in skeletally immature patients with osteogenesis imperfecta does not provide better outcome than elongating rods. Complications from bone plating leading to revision, such as refracture or hardware failure, are higher than in those children managed with elongating rods, as previously reported in the literature.

Adolescent↗