PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Chromatography, Liquid”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

High temperature liquid chromatography and liquid chromatography-mass spectroscopy analysis of octylphenol ethoxylates on different stationary phases.

Temperature was investigated as active parameter in the liquid chromatography (LC) analysis of octylphenol ethoxylates. Significant differences in selectivity were observed when the oligomers were analyzed by reversed phase LC (RPLC) on silica-, zirconia- and polystyrene/divinylbenzene based stationary phases at low (ambient), medium and elevated temperature with acetonitrile/water as mobile phase. As ascertained by LC-mass spectroscopy (MS), in most cases the elution order of the oligomers was completely reversed comparing ambient and high temperature separations. On a graphitized carbon type column, the selectivity remained unchanged, regardless the analysis temperature. Also in normal phase LC, the elution order remained unaffected by temperature variations both for acetonitrile/water and methanol/water mixtures as mobile phase. Surprisingly, when reversed phase LC on a octadecylsilicagel column at different temperatures was repeated with methanol instead of acetonitrile as mobile phase ingredient, the reversal of elution order did not take place. Results are evaluated in terms of thermodynamic parameters.

Chromatography, Liquid↗

Determination of trans octadecenoic acids by silver-ion chromatography-gas liquid chromatography: an intercomparison of methods.

Several silver-ion chromatography-gas liquid chromatography (GLC) techniques for the determination of trans octadecenoic acids in partially hydrogenated vegetable fats were collaboratively evaluated. Twelve laboratories participated in the study. All collaborators used high polarity fused silica capillary columns for the separation of fatty acid methyl esters by GLC; 7 collaborators isolated trans monoenes by silver-ion liquid chromatography (Ag-LC) and the remainder used silver-ion thin-layer chromatography (Ag-TLC). Eight artificially prepared materials [soybean oil spiked with either methyl elaidate, trielaidin, or trans octadecenoates isolated from partially hydrogenated sunflower oil (PHSO)] and 2 matrix materials (PHSO and a blend of PHSO and palm oil) served as test samples. Ag-TLC and Ag-LC proved to be equivalent techniques for the prefractionation of trans monoenes. Recovery of methyl elaidate, trielaidin, or trans octadecenoates isolated from PHSO varied between 97.9-103.7% over a concentration range of 1 to 30 g trans fatty acids/100 g. Reproducibility relative standard deviation (RSDR) for the spiked samples were in the range of 3.1-8.6% for 30-1% trans monoene content. For the 2 matrix samples (mean 3.75 and 19.08% trans monoene content) RSDR was 13.2 and 3.6%. The hyphenated techniques tested proved to be highly accurate and sufficiently precise methods for the determination of trans monoenes in partially hydrogenated vegetable fats. Procedural variations of the silver-ion chromatography prefractionation step (separation mode, mobile phase, and detection systems) did not significantly influence the results of the test. Therefore, silver-ion chromatography is a robust method, which does not need rigorous standardization to achieve high precision of test results. A further benefit of the hyphenated technique is that any type of efficient polar capillary column can be used.

Chromatography, Gas↗

Determination of drug enantiomers in biological samples by coupled column liquid chromatography and liquid chromatography-mass spectrometry.

Liquid chromatography-mass spectrometry (LC-MS) and coupled column chromatography can be used to overcome problems likely to occur in direct separation and determination of drug enantiomers in biological samples. This is exemplified here with the direct separation and determination of terbutaline in human plasma at the nmol/l level. A beta-cyclodextrin column with an aqueous mobile phase was used for chiral separation. For coupled column chromatography, the concentration of each enantiomer was calculated from the enantiomeric area ratio and the racemate concentration. A deuterium-labelled internal standard was used in the LC-MS experiments.

Chromatography, Gas↗

Separation and characterization of underivatized oligosaccharides using liquid chromatography and liquid chromatography-electrospray ionization mass spectrometry.

Native cyclodextrin-based columns are particularly useful for the analysis of oligosaccharides because the retention of these carbohydrates is based mainly on the hydrogen bonding interactions of oligosaccharide hydroxyl groups with the stationary phase. Thus, the retention time predictably increases with the number of analyte hydroxyl groups, which corresponds to the elongation of the oligosaccharide chain. High-performance liquid chromatography (HPLC) coupled to electrospray ionization (ESI) mass spectrometry (MS) was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 pg, all individual components of oligosaccharide mixtures (up to 11 glucose units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. Low flow rates and narrow I.D. columns increase the ESI-MS sensitivity significantly. The method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace levels of individual oligosaccharide or oligosaccharide isomers from biological systems.

Acetonitriles↗

Separation of stereoisomers of several furan derivatives by capillary gas chromatography-mass spectrometry, supercritical fluid chromatography, and liquid chromatography using chiral stationary phases.

The direct separation of several stereoisomers (enantiomers and geometrical isomers) of furan derivatives, important intermediates for the synthesis of physiologically active natural products, was achieved using capillary gas chromatography/mass spectrometry with a per-O-methyl-beta-cyclodextrin, supercritical fluid chromatography and high-performance liquid chromatography with a tris(3,5-dimethylphenylcarbamate) of cellulose or amylose for the chiral stational phases, respectively. The temperature dependence of the peak resolution (Rs) and the retention factor (k) over the range of 110-130 degrees was studied using crotyl furfuryl ether in gas chromatography. Successive increases in the Rs value and of the difference between the k value of the E-isomer and the k value of the Z-isomer were observed when the gradient temperature was decreased. The per-O-methyl-beta-cyclodextrin column was suitable for use with volatile furan ethers whose molecular masses are between 150 and 180. In conclusion, the separation of thermally unstable furan derivatives was accomplished using supercritical fluid chromatography and high-performance liquid chromatography.

Chromatography, High Pressure Liquid↗

Determination of selected polycyclic aromatic hydrocarbons and oxygenated polycyclic aromatic hydrocarbons in aerosol samples by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry.

Fine and ultrafine particles are probably responsible for numerous health effects, but it is still unclear whether and to what extent the particle itself or organic compounds adsorbed or condensed on the particle are responsible for the effects observed. One important class of particle-bound substances are the polycyclic aromatic hydrocarbons (PAH) and their oxygenated derivatives. To improve the tools used for chemical characterization of particulate matter analytical methods for the determination of PAH and oxygenated PAH in aerosol samples of different origin have been developed and optimized. PAH on high-volume filters and on soot aerosols were analyzed by using accelerated solvent extraction for extraction and high-performance liquid chromatography with fluorescence detection for separation and quantification. Total PAH concentrations were in the range 0.3-9.3 ng m(-3). For analysis of selected oxygenated PAH on high-volume filters a liquid chromatography-tandem mass spectrometric method was developed and optimized. Preliminary investigations showed that oxygenated PAH at pg m(-3) concentrations can be determined.

Aerosols↗

Determination of phenols in water using liquid phase microextraction with back extraction combined with high-performance liquid chromatography.

Liquid phase microextraction with back extraction (LPME/BE) combined with high-performance liquid chromatography (HPLC) was studied for the determination of a variety of phenols in water samples. The target compounds were extracted from 2-ml aqueous sample adjusted to pH 1 (donor solution) through a microliter-size organic solvent phase (400-microl n-hexane), confined inside a small PTFE ring, and finally into a 1-microl basic aqueous acceptor microdrop suspended inthe aforementioned solvent phase from the tip of a microsyringe needle. After extracting for a prescribed time, the microdrop was taken back into the syringe and directly injected into an HPLC for detection. Factors relevant to the extraction procedure were studied. At the optimized extraction conditions, a large enrichment factor (more than 100-fold) can be achieved for most of the phenols within 35 min. The detection limit range was 0.5-2.5 microg/l for different analytes in aqueous samples. The results demonstrate the suitability of the LPME/BE approach to the analysis of polar compounds in aqueous samples.

Chromatography, High Pressure Liquid↗

Simultaneous determination of pirlindole enantiomers and dehydropirlindole by chiral liquid chromatography.

Liquid chromatography was employed for the determination of pirlindole enantiomers and its oxidation product dehydropirlindole (DHP). The direct separation of pirlindole enantiomers and DHP was achieved on a cellulose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase (Chiralcel OD-R). Acetonitrile was used as the organic modifier and sodium perchlorate was used as an ionic additive in the mobile phase. The influence of acetonitrile and sodium perchlorate concentrations on enantioselectivity and achiral selectivity towards DHP was investigated in order to find suitable conditions for the determination of low amounts of each analyte. The mobile phase selected consisted of a mixture of acetonitrile and phosphate buffer (pH 5.0) containing sodium perchlorate (0.05 M) (35:65, v/v) and the UV detector was set at 220 nm. The method developed was validated and was found to be linear in the 0.1-5 microg ml(-1) range (r2 = 0.999 for the three compounds). Repeatability and the intermediate precision for the three analytes at a concentration of 0.1 microg ml(-1) were about 3 and 4%, respectively. This concentration corresponds to the quantification of 0.1% for the minor enantiomer. Actual determinations of enantiomeric purity for single enantiomers of pirlindole were performed.

Acetonitriles↗

Comprehensive two-dimensional liquid chromatography and hyphenated liquid chromatography to study the degradation of poly(bisphenol A)carbonate.

Size exclusion chromatography (SEC), gradient polymer elution chromatography (GPEC) and liquid chromatography at critical conditions (LC-CC) have been developed and applied to observe chemical changes in poly(bisphenol A)carbonate (PC) due to hydrolytic degradation. Especially LC-CC appeared to be very successful to observe differences in functionality of PC as result of hydrolytic degradation. Observed differences due to degradation could be identified by (semi) on-line coupling to matrix assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The differences in functionality could be attributed to the formation of different end-groups, i.e. OH end-groups. In addition, comprehensive two-dimensional liquid chromatography (2D-LC) has been applied successfully to study the hydrolytic degradation of PC. LC-CC x SEC showed that the formation of PC with different end-groups occurred over the whole molecular mass range. This information could not be obtained with the separate liquid chromatographic techniques, thereby illustrating the added value of 2D-LC.

Benzhydryl Compounds↗

Quantification of carotenoids in chicken plasma after feeding free or esterified lutein and capsanthin using high-performance liquid chromatography and liquid chromatography-mass spectrometry analysis.

The present study reports about the plasma carotenoid levels of chickens achieved after feeding diets containing free and esterified lutein (from marigold) and capsanthin (from red pepper) by applying HPLC analyses using a RP-C30 column. Forty chickens were divided at random into four groups and were fed 2 wk with different diets after receiving a basal diet with a low carotenoid content for carotenoid depletion (3 wk). One group was fed a diet containing free lutein (G1), another group received a diet with esterified lutein (G2), two other diets contained free (R1) and esterified capsanthin (R2), respectively. To unequivocally identify plasma carotenoids, liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis was applied, which had never been used as an analytical tool to evaluate the carotenoids of chicken plasma; HPLC chromatograms of chicken plasma following capsanthin feeding have not been presented. The study showed that not only lutein but also capsanthin appeared in the blood stream after feeding free or esterified xanthophylls, demonstrating that capsanthin esters were bioavailable. Quantitative analysis showed comparable concentrations of plasma lutein and capsanthin, respectively, no matter if free or esterified carotenoids were fed.

Animal Nutritional Physiological Phenomena↗

Analysis of eight capsaicinoids in peppers and pepper-containing foods by high-performance liquid chromatography and liquid chromatography-mass spectrometry.

Diverse procedures have been reported for the isolation and analysis of secondary metabolites called capsaicinoids, pungent compounds in the fruit of the Capsicum (Solanaceae) plant. To further improve the usefulness of high-performance liquid chromatography (HPLC), studies were carried out on the analysis of extracts containing up to eight of the following capsaicinoids: capsaicin, dihydrocapsaicin, homocapsaicin-I, homocapsaicin-II, homodihydrocapsaicin-I, homodihydrocapsaicin-II, nonivamide, and nordihydrocapsaicin. HPLC was optimized by defining effects on retention times of (a) the composition of the mobile phase (acetonitrile/0.5% formic acid in H2O), (b) the length of the Inertsil column, and (c) the capacity values (k) of the column packing. Identification was based on retention times and mass spectra of individual peaks. Quantification was based on the UV response at 280 nm in HPLC and recoveries from spiked samples. The method (limit of detection of approximately 15-30 ng) was successfully used to quantify capsaicinoid levels of parts of the pepper fruit (pericarp, placenta, seeds, and in the top, middle, and base parts of whole peppers) in 17 species of peppers and in 23 pepper-containing foods. The results demonstrate the usefulness of the method for the analysis of capsaicinoids ranging from approximately 0.5 to 3600 microg of capsaicin equiv/g of product. The water content of 12 fresh peppers ranged from 80.8 to 92.7%. The described freeze-drying, extraction, and analysis methods should be useful for assessing the distribution of capsaicinoids in the foods and in defining the roles of these biologically active compounds in the plant, the diet, and medicine.

California↗

Characterization of in vitro metabolites of toad venom using high-performance liquid chromatography and liquid chromatography-mass spectrometry.

The characterization of the in vitro metabolites of toad venom, which has been widely used as a traditional Chinese drug, Ch'an Su, has been completed. Toad venom contains bufotoxins (such as marinobufotoxin; marinobufagin 3-suberoylarginine ester) and bufogenins (such as marinobufagin and bufalin) as the main cardiac steroids. An in vitro experiment using the rat or human liver cytosolic fraction disclosed that marinobufotoxin produced marinobufagin, but not its 3-hemisuberate. Marinobufagin was subjected to the enzyme reaction using the rat or human liver microsomal fraction together with NADPH and NAD, which produced 3-dehydromarinobufagin and 3-epimarinobufagin. Marinobufagin produced its 3-sulfate upon treatment with the rat or human liver cytosolic fraction and 3'-phosphoadenosine 5'-phosphosulfate. Bufalin was also subjected to the above enzyme reactions and showed almost the same results except for the result that the hydroxylation occurred at the 5beta-position. On the other hand, small amounts of marinobufagin 3-glucuronide were obtained only by treatment with the human liver microsomal fraction and uridine 5'-diphosphoglucuronic acid. The structures of these metabolites were confirmed using authentic samples regarding their high-performance liquid chromatographic behavior and/or liquid chromatography-mass spectrometry analysis.

Amphibian Venoms↗

Broad range analysis of endocrine disruptors and pharmaceuticals using gas chromatography and liquid chromatography tandem mass spectrometry.

Endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) have been globally detected in impacted natural waters. The detection of trace quantities of EDCs and PPCPs in the environment is of great concern since some of these compounds have known physiological responses at low concentrations. EDCs can have a wide range of polarities, acidic and basic moieties, and exist in trace quantities, which often requires numerous complex extractions, large sample collection volumes, and multiple instrumental analyses. A comprehensive method has been developed allowing for the analysis of 58 potential EDCs in various water matrices using a single solid-phase extraction (SPE) of a 1L sample with subsequent analyses using both gas chromatography and liquid chromatography, each coupled with tandem mass spectrometry (GC-MS/MS and LC-MS/MS). Instrument detection limits ranged between 0.12-7.5 pg with corresponding method reporting limits of 1-10 ng l(-1) in water. Recoveries for most compounds were between 50% and 112% with good reproducibility (RSD 6-22%).

Chromatography, Liquid↗

Comparison of supercritical fluid chromatography and liquid chromatography for the separation of urinary metabolites of nobiletin with chiral and non-chiral stationary phases.

Nobiletin (NOB), a polymethoxylated flavone found in sweet orange (Citrus sinensis) peel, is currently recognized as a promising anti-inflammatory and anti-tumor agent. It is believed that, by undergoing metabolic biotransformation in vivo, nobiletin is demethylated by hepatic P450 enzymes, yielding multiple hydroxylated metabolites. However, it has not been possible to date to separate the two demethylated nobiletin metabolites, 3'-demethyl-NOB and 4'-demethyl-NOB (regio-isomers) on reversed-phase liquid chromatography (RPLC). Additionally, both display similar mass spectrometric fragmentation, resulting in difficulties to identify the dominant metabolite. A successful separation method was developed by utilizing supercritical fluid chromatography (SFC) with chiral stationary phase. The separation was also attempted with normal-phase liquid chromatography (NPLC) in both chiral and non-chiral modes. Chromatographic separation for the two nobiletin metabolites was superior by SFC than by LC, especially using chiral stationary phase. By comparing the SFC profile of the synthesized standards, the major nobiletin metabolite in mouse urine was identified as 4'-demethyl-NOB, with the concentration of 28.9 microg/mL.

Animals↗

A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography.

A novel approach for the selection of the operational parameters (linear velocity, column length) for a comprehensive 2D-LC system is discussed. Starting point for the calculations is a given second dimension ((2)D) separation and a desired peak capacity for the 2D system. Using the theory developed here the optimum settings for the first dimension ((1)D) column can be derived. Theory clearly indicates that the choice of the (1)D conditions is basically limited to just one set of column lengths and linear velocities. The new method is tested on a comprehensive two-dimensional liquid chromatography system which uses size-exclusion chromatography (SEC) followed by reversed phase liquid chromatography (RPLC). A novel LC/LC interface, using a six-port valve rather than storage loops, joins the two chromatographic dimensions. From a theoretical comparison of continuous low flow and stop-flow operation the latter method was found to be an attractive mode of interfacing. The common idea that stop-flow operation results in additional band broadening is shown to be incorrect. The new interface design operated in the stop-flow mode permits the use of conventional analytical diameter HPLC columns, 7.8mm for SEC and 4.6mm for RPLC. The reversed phase chromatography utilizes a monolithic C-18 modified silica column, which produces fast and efficient analyses. As test samples complex mixtures of peptides were analyzed.

Chromatography, Gel↗

Development of analyses by high-performance liquid chromatography and liquid chromatography/tandem mass spectrometry of bilberry (Vaccinium myrtilus) anthocyanins in human plasma and urine.

Anthocyanins are potent antioxidants that may possess chronic disease preventive properties. Here, rapid, reliable, and reproducible solid-phase extraction, high-performance liquid chromatography (HPLC), and mass spectrometry techniques are described for the isolation, separation, and identification of anthocyanins in human plasma and urine. Recoveries of cyanidin-3-glucoside (C3G) were 91% from water, 71% from plasma, and 81% from urine. Intra- and interday variations for C3G extraction were 9 and 9.1% in plasma and 7.1 and 9.1% in urine and were less than 15% for all anthocyanins from a standardized bilberry extract (mirtoselect). Analysis of mirtoselect by HPLC with UV detection produced spectra with 15 peaks compatible with anthocyanin components found in mirtoselect within a total run time of 15 min. Chromatographic analysis of human urine obtained after an oral dose of mirtoselect yielded 19 anthocyanin peaks. Mass spectrometric analysis employing multiple reaction monitoring suggests the presence of unchanged anthocyanins and anthocyanidin glucuronide metabolites.

Anthocyanins↗

Quantitative determination of coenyzme Q10 by liquid chromatography and liquid chromatography/mass spectrometry in dairy products.

The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25 degrees C on a Hyperclone ODS 5 microm 150 x 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 +/- 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3:0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 microm, 150 x 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 +/- 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+ m/z 863.4 +/- 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75-90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.

Acetic Acid↗

[Qualitative and quantitative analysis of bioactive principles in Zingiberis Rhizoma by means of high performance liquid chromatography and gas liquid chromatography. On the evaluation of Zingiberis Rhizoma and chemical change of constituents during Zingiberis Rhizoma processing].

As a continuing study on the evaluation of various Zingiberis Rhizoma and the chemical characterization of the processing, a quantitative method by high performance liquid chromatography (HPLC) for 6, 8, 10-gingerol (1, 2, 3), 6,8-shogaol (4, 5), 6-dehydrogingerdione (6), and galanolactone (7) has been developed. By the use of this HPLC method, the contents of these compound in twenty kinds of Zingiberis Rhizoma [originating in China, Taiwan, Vietnam, and Japan (Shizuoka Prefecture)] and fresh ginger root cultivated in Shizuoka Prefecture were examined. It was found that Japanese Zingiberis Rhizoma and fresh ginger root contained 6-gingerol (1), 6-dehydrogingerdione (6), and galanolactone (7) as major constituents, whereas 7 was not detected in imported Zingiberis Rhizoma and 6 was detected in Vietnamese Zingiberis Rhizoma. Furthermore, the contents of 1 and 7 in fresh ginger root decreased remarkably during the processing procedure for Zingiberis Rhizoma. In addition, anti-ulcer sesquiterpene constituents in seven kinds of Zingiberis Rhizoma were analyzed by means of gas liquid chromatography (GLC).

Chromatography, Gas↗