Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry.

This paper presents experimentally determined correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry. The correction factors were determined from measurements made in a PMMA phantom and calculation of ratios of measured charges. The ratios were corrected for the different volumes of the ionization chambers, determined in external high-energy electron beams. The correction factors for the central electrode effect and the wall material dependency in 60Co brachytherapy dosimetry agree with those used in external 60Co beam dosimetry. In 192Ir dosimetry, the central aluminium electrode increases the response of an NE2571 chamber compared with that of a chamber with a central graphite electrode. The increase is 1.1 and 2.1% at 1.5 and 5.0 g cm(-2) distance, respectively. Similar values are obtained with an NE2577 chamber. The wall correction factor in 192Ir dosimetry for a chamber with an A-150 wall has been determined to be 1.018, independent of the measurement distance. For a graphite walled chamber, the correction factor is 0.996 and 1.001 at 1.5 and 5.0 g cm(-2) distance, respectively. The values of the wall correction factors are evaluated by a theory presented. If the chamber is used according to the 'large cavity' principle, the correction factor to account for the replacement of the phantom material by the ionization chamber was determined to be 0.982 for an NE2571 chamber when used with a Delrin cap, and 0.978 for an NE2581 when used with a polystyrene cap. The correction factors for the 'large cavity' principle are valid at both 60Co and 192Ir qualities.

Biophysical Phenomena↗

The energy correction factor of LiF thermoluminescent dosemeters in megavoltage electron beams: Monte Carlo simulations and experiments.

The energy correction factor of LiF thermoluminescent dosemeters (TLDs) calibrated in Co-60 gamma-rays and used for measurements in megavoltage electron beams has been determined experimentally and theoretically using Monte Carlo simulations. The experiments show that the energy correction factor of 1 mm thick TLD-100 has an average for both rods and chips which varies from 1.036 +/- 1.3% (1 SD) for 4 MeV electron beams to 1.021 +/- 1.3% (1 SD) for 20 MeV electron beams for measurement performed at dmax in PMMA (Perspex). The results of the Monte Carlo simulations were within 0.6% of the experimental results and ranged from 1.041 +/- 0.9% (1 SD) for 2 MeV electrons to 1.028 +/- 0.8% (1 SD) for 20 MeV electron beams. There was no significant difference in the energy correction factors of LiF TLDs irradiated in PMMA or water by Monte Carlo simulation and experiments. Differences in the energy correction factors between rods and chips of the same thickness were negligible both in the experiments and in Monte Carlo calculation. When the diameter of the LiF TLD micro-rod was increased from 1 to 5 mm, the simulated energy correction factors increased by as much as 5% over this energy range. The energy correction factors changed by up to 4% for irradiation of TLD at depths other than at dmax for a 5 MeV mono-energetic electron beam.

Biometry↗

Correction factors for 13C-labelled substrate oxidation at whole-body and muscle level.

The oxidation of fatty acids, carbohydrates and amino acids can be measured by quantifying the rate of excretion of labelled CO2 following administration of 14C- or 13C-labelled substrates at whole-body and tissue level. However, there is a theoretical need to correct the oxidation rates for the proportion of labelled CO2 that is produced via oxidation but not excreted. Furthermore, depending on the substrate and position of the C label(s), there may also be a need to correct for labelled C from the metabolized substrate that does not appear as CO2, but rather becomes temporarily fixed in other metabolites. The bicarbonate correction factor is used to correct for the labelled CO2 not excreted. Recently, an acetate correction factor has been proposed for the simultaneous correction of CO2 not excreted and label fixed in other metabolites via isotopic exchange reactions, mainly in the tricarboxylic acid cycle. Changes in metabolic rate induced, for example, by feeding, hormonal changes and physical activity, as well as infusion time, have been shown to affect both correction factors. The present paper explains the theoretical and physiological basis of these correction factors and makes recommendations as to how these correction factors should be used in various physiological conditions.

Acetates↗

Hyponatremia: evaluating the correction factor for hyperglycemia.

PURPOSE: There are no controlled experimental data that assess the accuracy of the commonly used correction factor of a 1.6 meq/L decrease in serum sodium concentration for every 100 mg/dL increase in plasma glucose concentration. The purpose of this study was to evaluate experimentally the hyponatremic response to acute hyperglycemia. SUBJECTS AND METHODS: Somatostatin was infused to block endogenous insulin secretion in 6 healthy subjects. Plasma glucose concentrations were increased to >600 mg/dL within 1 hour by infusing 20% dextrose. The glucose infusion was then stopped and insulin given until the plasma glucose concentration decreased to 140 mg/dL. Plasma glucose and serum sodium concentrations were measured every 10 minutes. RESULTS: Overall, the mean decrease in serum sodium concentration averaged 2.4 meq/L for every 100 mg/dL increase in glucose concentration. This value is significantly greater than the commonly used correction factor of 1.6 (P = 0.02). Moreover, the association between sodium and glucose concentrations was nonlinear. This was most apparent for glucose concentrations >400 mg/dL. Up to 400 mg/dL, the standard correction of 1.6 worked well, but if the glucose concentration was >400 mg/dL, a correction factor of 4.0 was better. CONCLUSION: These data indicate that the physiologic decrease in sodium concentration is considerably greater than the standard correction factor of 1.6 (meq/L Na per 100 mg/dL glucose), especially when the glucose concentration is >400 mg/dL. Additionally, a correction factor of a 2.4 meq/L decrease in sodium concentration per 100 mg/dL increase in glucose concentration is a better overall estimate of this association than the usual correction factor of 1.6.

Adult↗

Correction factors for the INER-improved free-air ionization chambers calculated with the Monte Carlo method.

Monte Carlo method was used to simulate the correction factors for electron loss and scattered photons for two improved cylindrical free-air ionization chambers (FACs) constructed at the Institute of Nuclear Energy Research (INER, Taiwan). The method is based on weighting correction factors for mono-energetic photons with X-ray spectra. The newly obtained correction factors for the medium-energy free-air chamber were compared with the current values, which were based on a least-squares fit to experimental data published in the NBS Handbook 64 [Wyckoff, H.O., Attix, F.H., 1969. Design of free-air ionization chambers. National Bureau Standards Handbook, No. 64. US Government Printing Office, Washington, DC, pp. 1-16; Chen, W.L., Su, S.H., Su, L.L., Hwang, W.S., 1999. Improved free-air ionization chamber for the measurement of X-rays. Metrologia 36, 19-24]. The comparison results showed the agreement between the Monte Carlo method and experimental data is within 0.22%. In addition, mono-energetic correction factors for the low-energy free-air chamber were calculated. Average correction factors were then derived for measured and theoretical X-ray spectra at 30-50 kVp. Although the measured and calculated spectra differ slightly, the resulting differences in the derived correction factors are less than 0.02%.

Journal Article↗

Electron fluence perturbation correction factors for solid state detectors irradiated in megavoltage electron beams.

The perturbation correction factor gamma(p) is defined as the deviation of the absorbed dose in the medium from that predicted by the Spencer-Attix extension of the Bragg-Gray cavity theory where the medium occupies exactly the same volume as the solid state cavity and the electron fluence energy spectrum in the cavity is identical in shape, but not necessarily in magnitude, to that in the medium. The value of gamma(p) has been examined for TL detectors irradiated in megavoltage electron beams (5-20 MeV) using the EGS4 Monte Carlo code. LiF and CaF2 solid state detectors simulated were standard size discs of thickness 1 mm and diameter 3.61 mm irradiated in a water phantom with their centres at d(max) or close to it. Values of gamma(p) for LiF ranged from 0.998 +/- 0.005 to 0.994 +/- 0.005 for electron beams with initial energies of 5 and 20 MeV respectively. For CaF2 the corresponding values were 0.956 +/- 0.006 to 0.989 +/- 0.006 for the same size cavities irradiated at the same depth. EGS4 Monte Carlo simulations demonstrate that the total electron fluence (primary electrons and delta-rays) in these solid state detector materials is significantly different from that in water for the same incident electron energy and depth of irradiation. Thus the Spencer-Attix assumption that the electron fluence energy spectrum in the cavity is identical in shape to that in the medium is violated. Differences in the total electron fluence give rise to electron fluence perturbation correction factors which were up to 5% less than unity for CaF2, indicating a strong violation in this case, but were generally less than 1% for LiF. It is the density of the cavity which perturbs the electron fluence, but it is actually the atomic number differences between the medium and cavity that are responsible for the large electron fluence perturbation correction factors for detectors irradiated close to d(max) because the atomic number affects the change in stopping power with energy. When correction is made for the difference between the electron fluence spectrum in the uniform water phantom and the solid state cavity, the Spencer-Attix cavity equation predicts the dose to water within 0.3% in both clinical and monoenergetic electron beams. Harder's formulation for computing the average mass collision stopping power of water to calcium fluoride, surprisingly, requires perturbation correction factors that are closer to unity than those determined using the Spencer-Attix integrals at depths close to d(max).

Electrons↗

Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometers.

OBJECTIVE: To assess the effects of different oxygen concentrations and flow rates on the measurement errors of neonatal pneumotachometers in heated and unheated situations and to develop correction factors to correct for these effects. DESIGN: Prospective laboratory study. SETTING: Outpatient clinic with equipment in a standardized setting. SUBJECTS: Neonatal pneumotachometers. INTERVENTIONS: In standardized conditions, the tested pneumotachometer was calibrated at a flow rate of 3 L/min with 60% oxygen and was set in series with a closed spirometer system being used as a reference. Different air-flow levels (1-9 L/min) and oxygen concentrations (21-100%) were infused into the closed system with the pneumotachometer and spirometer. MEASUREMENTS AND MAIN RESULTS: The pneumotachometers were significantly affected by changing oxygen concentrations (p < .01) and increasing flow rates (p < .01), increasing the actually measured flow rate. Correction factors, developed by multiple regression analysis, significantly reduced the overall maximum errors of the pneumotachometers from -1.1 to 0.6 L/min to -0.5 to 0.4 L/min. CONCLUSIONS: The effects of changes in oxygen concentrations and flow rates on neonatal pneumotachometers could be considerably decreased by the use of correction factors such as were calculated in this study. This will preclude frequent calibration procedures with actual flow and oxygen levels during changes in experimental settings.

Equipment Design↗

Estimation of bioconcentration factors of nonionic organic compounds in fish by molecular connectivity indices and polarity correction factors.

A bioconcentration factor (BCF) estimation model for a wide range of nonionic organic compounds was developed on the basis of molecular connectivity indices and polarity correction factors. The nonlinear topological modeling using polarity correction factors resulted in the best BCF estimation quality for all of the 239 compounds studied, with a mean absolute estimation error of 0.478 log units. Residual analysis indicated that the estimation errors came from many sources including BCF measurement, test species, and selection of descriptors. Statistical robustness of the developed model was validated by modified jackknifed tests where random deletion of a set of compounds and specific deletion of a class of compounds were both performed. Comparison between the MCI-based (molecular connectivity indices) model and a Kow-based (octanol/water partition coefficient) model revealed that the BCF estimation based on topological parameters was as good as that achieved by Kow.

Animals↗

[Prediction of bioconcentration factors of organic compounds in fish by molecular connectivity indices and function correction factors].

Studies on the prediction models of bioconcentration factors(BCF) of 239 organic compounds showed that the BCFs of polar organic compounds could not be accurately predicted solely by the linear model based on molecular connectivity indices. Additionally, the linear model was not suitable for superphilic compounds. By introducing function correction factors to the model, the residual of the prediction model for polar organic compounds was reduced significantly. When the nonlinear estimation was used, the accuracy of the obtained model was further improved. The final prediction model consisted of parameters (0 chi v)2, (2 chi v)1/2, 2 chi, 3 chi c, 0 chi v and 10 correction factors for function groups OH, NH2, NO2, NCOO, etc. The difference between calculated and observed values of logBCF and its causes were analyzed. The robustness of the model was tested by Jackknifed method, based on random grouping and compound classification.

Animals↗

Two types of phantom scatter correction factors (Sp) for high-energy photons.

Two types of phantom scatter correction factors (Sp) are introduced for high-energy photons. One is the traditional Sp correction factor. It is produced using the primary absorbed dose under lateral CPE (charged particle equilibrium). It usually takes a non-zero value at zero-area field. The other is produced using the actual primary absorbed dose, which fails in lateral CPE when the field is small. It takes a value of zero at zero-area field. The two types of Sp correction factors can be connected with the laterally spread primary absorbed dose (LSD).

Humans↗

Calculated energy response correction factors for LiF thermoluminescent dosemeters employed in the seventh EULEP dosimetry intercomparison.

Several dosimetry intercomparisons for whole body irradiation of mice have been organized by the European Late Effects Project Group (EULEP). These studies were performed employing a mouse phantom loaded with LiF thermoluminescent dosemeters (TLDs). In-phantom, the energy response of the LiF TLDs differs from free-in-air, due to spectral differences caused by attenuation and scatter of x-rays. From previous studies, energy response correction factors in-phantom relative to free-in-air were available for full scatter conditions. In the more recent intercomparisons, however, full scatter conditions were not always employed by the participants. Therefore, Monte Carlo calculations of radiation transport were performed to verify the LiF TLD energy response correction factors in-phantom relative to free-in-air for full scatter conditions and to obtain energy response correction factors for geometries where full scatter conditions are not met. For incident x-rays with HVLs in the 1 to 3.5 mm Cu range, the energy response correction factor in-phantom deviates by 2 to 4 per cent from that measured free-in-air. This is in reasonable agreement with previously published results. The energy response correction factors obtained from the present study refer to a calibration in terms of muscle tissue dose in-phantom using 60Co gamma rays. For geometries where full scatter conditions are not fulfilled, the energy response correction factors are different by up to about 3 per cent at maximum from that at full scatter conditions. The dependence of the energy response correction factor as a function of the position in-phantom is small, i.e. about 1 per cent at maximum between central and top or bottom positions.

Air↗

Correction factors for the NMi free-air ionization chamber for medium-energy x-rays calculated with the Monte Carlo method.

A new method is described for the determination of x-ray quality dependent correction factors for free-air ionization chambers. The method is based on weighting correction factors for mono-energetic photons, which are calculated using the Monte Carlo method, with measured air kerma spectra. With this method, correction factors for electron loss, scatter inside the chamber and transmission through the diaphragm and front wall have been calculated for the NMi free-air chamber for medium-energy x-rays for a wide range of x-ray qualities in use at NMi. The newly obtained correction factors were compared with the values in use at present, which are based on interpolation of experimental data for a specific set of x-ray qualities. For x-ray qualities which are similar to this specific set, the agreement between the correction factors determined with the new method and those based on the experimental data is better than 0.1%, except for heavily filtered x-rays generated at 250 kV. For x-ray qualities dissimilar to the specific set, differences up to 0.4% exist, which can be explained by uncertainties in the interpolation procedure of the experimental data. Since the new method does not depend on experimental data for a specific set of x-ray qualities, the new method allows for a more flexible use of the free-air chamber as a primary standard for air kerma for any x-ray quality in the medium-energy x-ray range.

Air↗

A mathematical description of the functionality of correction factors used in allometry for predicting human drug clearance.

The functionality of the correction factors, maximum life-span potential (MLP), and brain weight (BrW) used in allometry is mathematically described. Correction by MLP or BrW is equivalent to a multiplication of some constants by the predicted values in humans from simple allometry, but they have no relationship to measured pharmacokinetic parameters in the animal species. The values of these constants (F(MLP) or F(BrW)) were calculated for some commonly used combinations of animal species. For all combinations of animal species, the value of F(BrW) is always greater than that of F(MLP) with a fold-increase of about 1.3 to 1.9. Different combinations of species give different values of F(BrW) and F(MLP). In addition, the role of correction factors (MLP and BrW) or the "rule of exponents" (ROE) was evaluated. An intrinsic defect in using correction factors or ROE was revealed; different study designs will produce significantly different prediction results. However, ROE may still serve as a useful practical approach in predicting human CL since it was derived from real observations and has been applied to many examples.

Animals↗

A new correction factor for use in tracer estimations of plasma fatty acid oxidation.

The purpose of this study was to acquire a new correction factor for use in tracer estimations of plasma fatty acid oxidation that would fully account for label fixation during the infusion of fatty acid tracers. Thus volunteers were infused with 13C-labeled fatty acids and [1-14C]acetate in the basal state, during hyperinsulinemia-hyperglycemia (clamp), and during 1 h of cycling exercise. The fractional recovery of acetate label (i.e., the acetate correction factor) was 0.56 +/- 0.02, 0.50 +/- 0.03, and 0.80 +/- 0.03 in the basal state and during the clamp and exercise, respectively. Isotopically determined plasma fatty acid oxidation rates (mumol.kg-1.min-1) were 1.7 +/- 0.2, 0.8 +/- 0.2, and 6.4 +/- 0.5 (no correction); 2.1 +/- 0.2, 1.0 +/- 0.2, and 6.7 +/- 0.5 (bicarbonate correction); and 3.1 +/- 0.2, 1.5 +/- 0.2, and 8.2 +/- 0.4 (acetate correction). We conclude that use of the acetate correction factor in place of the bicarbonate correction factor should improve the accuracy of isotopic measurements of plasma fatty acid oxidation, because it accounts for label fixation that might occur at any step between the entrance of labeled acetyl-CoA into the tricarboxylic acid cycle until the recovery of label in breath CO2.

Acetates↗

Electron fluence correction factors for conversion of dose in plastic to dose in water.

In radiation dosimetry protocols, plastic is allowed as a phantom material for the determination of absorbed dose to water in electron beams. The electron fluence correction factor is needed in conversion of dose measured in plastic to dose in water. There are large discrepancies among recommended values as well as measured values of electron fluence correction factors when polystyrene is used as a phantom material. Using the Monte Carlo technique, we have calculated electron fluence correction factors for incident clinical beam energies between 5 and 50 MeV as a function of depth for clear polystyrene, white polystyrene and PMMA phantom materials and compared the results with those recommended in protocols as well as experimental values from published data. In the Monte Carlo calculations, clinical beams are simulated using the EGS4 user-code BEAM for a variety of medical accelerators. The study shows that our calculated fluence correction factor, phi pw, is a function of depth and incident beam energy Eo with little dependence on other aspects of beam quality. However the phi pw values at dmax are indirectly influenced by the beam quality since they vary with depth and dmax also varies with the beam quality. Calculated phi pw values at dmax are in a range of 1.005-1.045 for a clear polystyrene phantom, 1.005-1.038 for a white polystyrene phantom and 0.996-1.016 for a PMMA phantom. Our values of phi pw are about 1-2% higher than those determined according to the AAPM TG-25 protocol at dmax for clear or white polystyrene. Our calculated values of phi pw also explain some of the variations of measured data because of its depth dependence. A simple formula is derived which gives the electron fluence correction factor phi pw as a function of R50 at dmax or at the depth of 0.6R50-0.1 for any clinical electron beam with energy between 5 and 25 MeV for three plastics: clear polystyrene, white polystyrene and PMMA. The study also makes a careful distinction between phi pw and the corresponding IAEA Code of Practice quantity, hm.

Biophysical Phenomena↗

Monte Carlo calculated correction factors for primary standards of air kerma.

Many laboratories with cavity chambers as primary standards for air kerma are considering using additional Monte Carlo calculated correction factors, in particular the correction for attenuation and scatter in the walls, Kwall, and possibly the correction for point of measurement, Kan. Standards labs also use Monte Carlo calculated Spencer-Attix stopping-power ratios for graphite to air. The purpose of this article is to investigate the sensitivity of these calculations to their details and to assign uncertainties to the calculated values. We also investigate the correction needed for the Canadian primary standard to account for a polystyrene insulator, Kcomp and find that it is quite large (1.0046 +/- 0.0017). The article shows that the values of correction factors are very robust and insensitive to most details of the calculations except the values of the underlying electron stopping powers which have a significant effect on the stopping-power ratio and on Kcomp. The 1% uncertainties on the photon cross-sections have a negligible effect on these correction factors except for Kcomp. As a result of these investigations, with no change in the stopping power data used, the Canadian primary standard of air kerma in a 60Co beam needs to be increased by 0.54%.

Air↗

Energy-dependent polarity correction factors for four commercial ionization chambers used in electron dosimetry.

The polarity effects of four commercially available ionization chambers were characterized and correction factors as a function of mean energy at depth were tabulated. These included a Farmer-type chamber, two parallel plate chambers, and one cylindrical chamber used in a scanning water phantom dosimetry system. Polarity effects were measured at representative depths along the depth dose curves of 6, 9, 12, 16, and 20 Me V electron beams. The term "polarity error" is introduced and is defined as the error which is introduced if polarity effects are ignored. Polarity errors for the four ionization chambers studied were shown to monotonically decrease with increasing mean energy at depth and were largely independent of the energy of the incident electron beam. Only at very low energies, that is, very near the end of the practical range, did the correction factors for beams of different incident energy diverge. Three of the four chambers studied had correction factors which were independent of field size, to within +/- 1/2%. One chamber showed an increase in correction factor with increasing field size which was shown to be mainly due to stem and cable irradiation.

Evaluation Studies as Topic↗

Tissue-shrinkage correction factor in the calculation of prostate cancer volume.

Many studies that have calculated prostate cancer volumes from microscopic slides have used correction factors, ranging from 1.22 to 1.5, to compensate for tissue shrinkage during tissue processing. We undertook a study to measure tissue shrinkage directly because our experience suggested less shrinkage than that reported by others. Ten prostatectomy specimens were processed in a uniform manner. Multiple identical linear measurements were taken at four stages of processing: in the fresh state, following fixation, following processing, and from the microscopic slide. Linear shrinkage following fixation was minimal (4.1%) but increased to 14.5% following tissue processing. With rehydration and expansion on the flotation bath, tissues swelled so that net linear tissue shrinkage was 4.3%, and net volumetric tissue shrinkage was 12.4%, which translates into a correction factor for tissue shrinkage of 1.14. The following variables had no statistically significant effect on shrinkage: concentration of formalin, whole-mount versus quadrant sections, thickness of tissue slices, length of time in the alcohol dehydration steps, and temperature of the flotation bath over a range of 35 to 45 degrees C. This study suggests that (a) tissue-shrinkage correction factors that have been used in some previous studies may not be applicable for all laboratories because of interlaboratory variations in tissue-processing procedures or differences in measuring shrinkage; and (b) some calculated tumor volumes that have been used for prognostic thresholds may be high because of inflated tissue-shrinkage correction factors.

Humans↗