PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Error minimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Using blood glucose meters. Minimizing errors, maximizing accuracy.

Blood glucose meters (BGMs) provide fast and generally accurate measurements of the glucose levels of individuals with diabetes. But they aren't foolproof. A number of problems can affect BGM accuracy, including technical faults, user errors, and variations in patient physiology. An erroneous reading could mean that a hypo- or hyperglycemic patient might receive inappropriate therapy or perhaps no therapy at all, with potentially life-threatening consequences. In this article, we provide recommendations to individuals and healthcare providers on ways to minimize erroneous BGM readings. We also offer some troubleshooting tips and itemize the physiologic factors that can impact readings--a potential source of errors that is often overlooked.

Blood Glucose Self-Monitoring↗

Error minimization explains the codon usage of highly expressed genes in Escherichia coli.

Different organisms use synonymous codons with different preferences. Several measures have been introduced to compute the extent of codon usage bias within a gene or genome, among which the codon adaptation index (CAI) has been shown to be well correlated with mRNA levels of Escherichia coli. In this work an error adaptation index (eAI) is introduced, which estimates the level at which a gene can tolerate the effects of mistranslations. It is shown that the eAI has a strong correlation with CAI, as well as with mRNA levels, which suggests that the codons of highly expressed genes are selected so that mistranslation would have the minimum possible effect on the structure and function of the related proteins.

Base Composition↗

Phase-encode reordering to minimize errors caused by motion.

A new method for suppressing the effects of motion in MR images by reordering the acquisition of k space has been developed. Existing reordering methods suffer from image blurring. The method presented here applies specifically to translation along the phase-encoding direction, in which case it reduces both ghosting and blurring. The method is conceptually similar to a linear phase shift of k space, except that it has the advantage of not corrupting stationary structures inadvertently. The method is intended for anatomic sites in which substantial translational motion occurs along the phase-encoding direction, such as the cranial-caudal motion of the liver and kidneys. The reordering method is motivated from an analysis of factors affecting the severity of motion artifacts. The theory behind the reordering method is described and validated experimentally by imaging a moving phantom.

Artifacts↗

On the classes of aminoacyl-tRNA synthetases and the error minimization in the genetic code.

As a consequence of the existence of two classes of aminoacyl-tRNA synthetases (aaRSs), we defined two types of mutations: g (mutations that do not change the class of the involved amino acids) and u (those which change the class). We have found that the mean chemical distance resulting from g mutations is smaller than that corresponding to u mutations, indicating that g mutations are responsible for most of the known minimization of the genetic code. This supports models for the origin and evolution of the code, in which new amino acids were added after duplications or modification of existing aaRSs.

Amino Acids↗

The case for an error minimizing set of coding amino acids.

The fidelity of the translation machinery largely depends on the accuracy by which the tRNAs within the living cells are charged. Aminoacyl-tRNA synthetases (aaRSs) attach amino acids to their cognate tRNAs ensuring the fidelity of translation in coding sequences. Based on the sequence analysis and catalytic domain structure, these enzymes are classified into two major groups of 10 enzymes each. In this study, we have generally tackled the role of aaRSs in decreasing the effects of mistranslations and consequently the evolution of the translation machinery. To this end, a fitness function was introduced in order to measure the accuracy by which each tRNA is charged with its cognate amino acid. Our results suggest that the aaRSs are very well optimized in "load minimization" based on their classes and their mechanisms in distinguishing the correct amino acids. Besides, our results support the idea that from an evolutionary point, a selectional pressure on the translational fidelity seems to be responsible in the occurrence of the 20 coding amino acids.

Amino Acids↗

Implant position record and implant position cast: minimizing errors, procedures and patient visits in the fabrication of the milled-bar prosthesis.

This article describes a new rationale and method involved in the fabrication of a patient detachable prosthesis supported by a milled bar. This simple procedure improves prosthesis retention. The overdenture is processed directly over a milled bar, which provides an intimate relation between the bar and the acrylic resin denture base to create resistance against rotational and lateral forces acting on the prosthesis. Incorporating simple and predictable attachments, with low maintenance needs, controls resistance to dislodgment along the path of insertion of the prosthesis. The concepts used in the fabrication of the milled bar include an implant position record (IPR) and an implant position cast (IPC) to reduce the need for time-consuming procedures, such as sectioning the cast bar and soldering it to make it fit the abutments. This procedure also reduces the number of patient visits required of the completion of the prosthesis.

Dental Abutments↗

Minimizing Errors in Electron Microprobe Analysis.

Errors in quantitative electron microprobe analysis arise from many sources including those associated with sampling, specimen preparation, instrument operation, data collection, and analysis. The relative magnitudes of some of these factors are assessed for a sample of NiAl used to demonstrate important concerns in the analysis of even a relatively simple system measured under standard operating conditions. The results presented are intended to serve more as a guideline for developing an analytical strategy than as a detailed error propagation model that includes all possible sources of variability and inaccuracy. The use of a variety of tools to assess errors is demonstrated. It is also shown that, as sample characteristics depart from those under which many of the quantitative methods were developed, errors can increase significantly.

Journal Article↗

Minimizing errors of omission: behavioural reenforcement of heparin to avert venous emboli: the BEHAVE study.

OBJECTIVE: To improve patient safety by increasing heparin thromboprophylaxis for medical-surgical intensive care unit patients using a multiple-method approach to evidence-based guideline development and implementation. DESIGN: Prospective longitudinal observational study. SETTING: Medical-surgical intensive care unit. PARTICIPANTS: Multidisciplinary clinicians caring for critically ill patients in a 15-bed medical-surgical closed intensive care unit. INTERVENTIONS: Phase 1 was a 3-month baseline period during which we documented anticoagulation and mechanical thromboprophylaxis. Phase 2 was a 1-yr period in which we implemented a thromboprophylaxis guideline using a) interactive multidisciplinary educational in-services; b) verbal reminders to the intensive care unit team; c) computerized daily nurse recording of thromboprophylaxis; d) weekly graphic feedback to individual intensivists on guideline adherence; and e) publicly displayed graphic feedback on group performance. Phase 3 was a 3-month follow-up period 10 months later, during which we documented thromboprophylaxis. Computerized daily nurse recording of thromboprophylaxis continued in this period. MEASUREMENTS AND MAIN RESULTS: Intensive care unit and hospital mortality rates were similar across phases, although patients in phase 2 had higher Acute Physiology and Chronic Health Evaluation II scores than patients in phases 1 and 3. The proportion (median % [interquartile range]) of intensive care unit patient-days of heparin thromboprophylaxis in phases 1, 2, and 3 was 60.0 (0, 100), 90.9 (50, 100), and 100.0 (60, 100), respectively (p=.01). The proportion (median % [interquartile range]) of days during which heparin thromboprophylaxis was omitted in error in phases 1, 2, and 3 was 20 (0, 53.8), 0 (0, 6.3), and 0 (0, 0), respectively (p<.001). CONCLUSIONS: After development and implementation of an evidence-based thromboprophylaxis guideline, we found significantly more patients receiving heparin thromboprophylaxis. Guideline adherence was maintained 1 yr later. Further research is needed on which are the most effective strategies to implement patient safety initiatives in the intensive care unit.

Aged↗

Multiview registration of 3D scenes by minimizing error between coordinate frames.

This paper addresses the problem of large-scale multiview registration of range images captured from unknown viewing directions. To reduce the computational burden, we separate the local problem of pairwise registration on neighboring views from the global problem of distribution of accumulated errors. We define the global problem as an optimization over the graph of neighboring views, and we show how the graph can be decomposed into a set of cycles such that the optimal transformation parameters for each cycle can be solved in closed form. We then describe an iterative procedure that can be used to integrate the solutions for the set of cycles across the graph of views. This method for error distribution does not require point correspondences between views, and can be used to integrate any method of pairwise registration or robot odometry.

Algorithms↗

Delay time adjustments to minimize errors in breath-by-breath measurement of Vo2 during exercise.

If the delay time between gas concentration and flow signals is not adequately corrected during breath-by-breath analysis of expired gas, an error in calculation of oxygen consumption (Vo2) will result. To examine the frequency and delay time dependences of errors in Vo2 measurement, six healthy men exercised at 100, 200, and 250 W on a cycle ergometer while breath-by-breath assessment of Vo2 was made simultaneously with collection of expired air. Subjects breathed first at normal rates (15-30 breaths/min) and then at 70 breaths/min. Each subject performed each level of exercise twice by using erroneous values for the delay time between gas concentration and flow signals. At normal breathing frequencies, errors in Vo2 measurement were +/- 10% over the full range of delay times used, and the errors were not tightly correlated with variations in delay times from optimum. However, at 70 breaths/min, errors approached +/- 30% as the variations in delay times deviated +/- 0.1 s from the optimal, and the errors were highly correlated with the variations in delay times. We conclude that there is greater potential for errors in Vo2 measurement with incorrect delay time at higher breathing frequencies. These findings suggest that the optimal delay time for breath-by-breath systems should be adjusted by using high breathing frequencies.

Adult↗