PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HPLC”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Purification of monoclonal antibodies by hydroxylapatite HPLC and size exclusion HPLC.

Monoclonal antibodies of both the IgG and the IgM type were purified by hydroxylapatite HPLC (HA-HPLC) under very mild conditions. The IgM type antibodies, which were isolated from ascites fluid and separated from other proteins also by means of size exclusion HPLC. It was shown that the most frequently observed disadvantage of HA-HPLC, that is the relative short life of the columns (P. Steffen (1989) GIT Fachz. Lab., Suppl. 3/89 (Chromatogr.), 50-90), is due to microbial contamination rather than lower mechanical stability. In order to monitor column performance, a test was developed based on the use of standard proteins under isocratic separation conditions. This allows a direct comparison between the respective performances of columns made from different materials, hydroxylapatite or fluoroapatite, from different sources and with different particle sizes. A problem which often occurs with HA-HPLC in the case of IgM antibody isolation, namely precipitation of the antibodies at low salt concentrations at the beginning of a chromatographic run, was avoided by adding sodium chloride to both separation buffers.

Antibodies, Monoclonal↗

Study of phenformin metabolism in rat liver microsomes by HPLC, CE and on-line HPLC-electrospray ionization mass spectrometry.

Methods for the analysis of phenformin and its metabolite by high-performance liquid chromatography (HPLC), capillary electrophoresis (CE) and high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESIMS) are developed. The effects of pH, buffer concentration and proportion of organic modifier on the retention of the compounds in HPLC have been studied. The optimum condition was used for the separation and identification of phenformin and its metabolite in microsomal metabolism by HPLC-ESIMS. A simple CE method is also described for the separation of these compounds. Optimum incubation conditions and cofactor requirements for the formation of 4-hydroxyphenformin by microsomal preparations of rat liver were determined. A linear response in the formation of product was found with increasing concentrations of protein and up to 15 min incubation. High concentrations of phenformin inhibited its metabolite formation, and K(m) was 4 microM.

Acetates↗

Identification and determination of major flavonoids in rat urine by HPLC-UV and HPLC-MS methods following oral administration of Dalbergia odorifera extract.

Flavonoids are the main active constituents of Dalbergia odorifera. The excretion of the major flavonoids in rat urine after oral administration of D. odorifera extract was investigated by HPLC-UV and HPLC-MS methods. Utilizing the HPLC-MS technique, 18 flavonoids, including five isoflavones, four isoflavanones, four neoflavones, two flavanones, two chalcones and one isoflavanonol were identified in free form in a urine sample based on the direct comparison of the corresponding tR, UV maximum absorbance (lambda(max)) values and MS data with the authentic standards. The amounts of the prominent flavonoids, (3R)-4'-methoxy-2',3,7-trihydroxyisoflavanone and vestitone, were determined by HPLC-UV with the internal standard method, and the validation procedure confirmed that it afforded reliable analysis of these two analytes in urine after oral administration of D. odorifera extract.

Administration, Oral↗

Isolation and characterisation of selected germander diterpenoids from authenticated Teucrium chamaedrys and T. canadense by HPLC, HPLC-mS and NMR.

Teucrium species, such as germander, are rich in neo-clerodane diterpenoids and have been used in traditional folk medicine for their stimulant, diuretic, antipyretic and antiseptic properties. However, the furano neo-clerodane diterpenoids present in germander have been implicated in the in vivo hepatotoxicity of this botanical. In this study, authenticated germander (Teucrium chamaedrys L. and Teucrium canadense L.) was used as the source material. Methanol extracts of powdered plant mate rial were prepared and analysed by HPLC using Synergi Max-RP columns with monitoring at 220 nm. Limited amounts of teucrin A and other diterpenoid standards were analysed on a Synergi Max-RP column in order to determine their retention times and to generate calibration curves. The same standards were subjected to concurrent mass spectral analysis. Teucrin A and diterpenoids such as dihydroteugin, teuflin, teuflidin and teucvidin were tentatively identified in the plant extracts by HPLC-MS and 1H-NMR experiments. For the isolation of teucrium diterpenoids on a semipreparative scale, a solid-phase extraction method was developed for the first time using styrene divinylbenzene and strata-X sorbents for teucrin A and teuflin, respectively. Semi-preparative HPLC of the methanol extract of the powdered aerial parts of Teucrium plants was carried out on a semipreparative Synergi Max-RP column with photodiode array detection in order to confirm the identities of some diterpenoids by HPLC-MS and NMR.

Chromatography, High Pressure Liquid↗

Comparing the ESA HPLC total homocysteine assay with electrochemical detection to the CDC in-house HPLC assay with fluorescence detection.

BACKGROUND: Environmental science has developed a simple high performance liquid chromatography (HPLC) assay with electrochemical detection for total homocysteine (tHcy) measurement that does not require derivatization of free thiols. We evaluated this method and compared it with the CDC HPLC assay with fluorescence detection (FD). METHODS: tHcy is measured after reduction of disulfides/protein-bound thiols and protein precipitation using four channels of an ESA CoulArray detector. L-homocystine is used as calibrator, penicillamine as internal standard. RESULTS: Aqueous calibration of the ESA assay resulted in overestimation of tHcy by approximately 30% compared to the HPLC-FD method. Calibration in plasma alleviated the matrix effect. The within- (n=3) and between-run (n=20) imprecision was <6%, the linearity up to 100 micromol/l was excellent, and the recovery of tHcy added to plasma was nearly complete (98.7%+/-2.3%). Good correlation was observed between both methods for 266 plasma samples. The ESA assay showed a minimal negative bias of 0.28 micromol/l (3.3%). CONCLUSION: The ESA tHcy assay performed well in terms of accuracy and precision, and showed good agreement with the CDC HPLC-FD assay when calibrated in plasma. The major advantage of this assay is that it does not require sample derivatization. Disadvantages include instability of the prepared samples for prolonged storage and matrix effects.

Calibration↗

Identification and determination of major flavonoids in rat serum by HPLC-UV and HPLC-MS methods following oral administration of Dalbergiaodorifera extract.

The major flavonoids in rat serum after oral administration of Dalbergia odorifera extract were analyzed qualitatively and quantitatively by high performance liquid chromatography (HPLC) and its coupling to mass spectrometry (HPLC-MS). Utilizing HPLC-MS technique, 18 flavonoids including five isoflavones, four isoflavanones, four neoflavones, two flavanones, two chalcones, one isoflavanonol were identified in free form in serum sample based on comparison with the authentic standards. Furthermore, the amounts of the four prominent flavonoids, (3R)-4'-methoxy-2',3,7-trihydroxyisoflavanone, vestitone, formononetin and sativanone were determined in serum by HPLC-UV with internal standard method. The method was validated and utilized in pharmacokinetic studies of these four analytes. This is the first report on identification and determination of the major flavonoids in rat serum after oral administration of D. odorifera extract and the results provided a firm basis for clarifying the pharmacological effect of D. odorifera and evaluating the clinical applications of this medicinal herb.

Administration, Oral↗

Combined HPLC-MS and HPLC-NMR on-line coupling for the separation and determination of lutein and zeaxanthin stereoisomers in spinach and in retina.

The determination and unambiguous identification of carotenoid stereoisomers from biological tissues, avoiding isomerization and oxidation due to the extraction process, is still a major challenge. Particularly, the analysis of lutein and zeaxanthin stereoisomers is of great importance, as these are the main constituents of the macula lutea, the central part of the human retina, and act as possible agents in the prevention and treatment of age-related macular degeneration (AMD). By combining a mild and quick extraction technique such as matrix solid-phase dispersion together with high-performance liquid chromatography (HPLC), the extremely light and oxygen sensitive lutein and zeaxanthin stereoisomers are extracted, enriched, and separated directly from the solid plant or tissue samples, excluding preparation of artifacts. HPLC separations are performed with C30 phases due to their enhanced shape selectivity compared to C18 phases and on-line coupled to mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy. By using HPLC-MS with atmospheric pressure chemical ionization, the lutein stereoisomers can be distinguished from the zeaxanthin stereoisomers within one chromatographic run in the upper picogram range, whereas HPLC-NMR coupling allows the unequivocal identification of each stereoisomer with a concentration in the upper nanogram range. This article provides an analytical method for the artifact-free determination of lutein and zeaxanthin stereoisomers directly from the solid biological tissue spinach as a source of carotenoids and retina as the sphere of activity for AMD. In addition, the structures of these stereoisomers were unambiguously elucidated by employing hyphenated analytical techniques.

Chromatography, High Pressure Liquid↗

Study on metabolism of scutellarin in rats by HPLC-MS and HPLC-NMR.

Scutellarin is the major active constituent of Scutellaria barbata D. The metabolism of scutellarin has been investigated in rats. The solid-phase extraction and HPLC-DAD methods were established to separate and analyse metabolites. Five metabolites (M1-M5) were identified by enzymatic hydrolysis, HPLC-DAD, HPLC-MS and HPLC-NMR. M1 and M3 were conjugates of scutellarin with two sulfate groups, which have not been reported in natural plants. M2 was scutellarin; M4 was 6-methyl-scutellarin; and M5 was 6-methyl-scutellarein. The metabolic pathway was proposed.

Administration, Oral↗

Identification of a radical formed in the reaction mixtures of oxidized phosphatidylcholine with ferrous ions using HPLC-ESR and HPLC-ESR-MS.

Identification of free radicals was performed for the reaction mixtures of autoxidized 1,2-dilinoleoylphosphatidylcholine (DLPC) with ferrous ions (or DLPC hydroperoxide with ferrous ions) and of DLPC with soybean lipoxygenase using electron spin resonance (ESR), high performance liquid chromatography (HPLC)--ESR and HPLC--ESR-mass spectrometry (MS) combined use of spin trapping technique. ESR measurements of the reaction mixtures showed prominent signals with hyperfine coupling constants (a(N)=1.58 mT and a(H)beta=0.26 mT). Outstanding peaks with almost same retention times (autoxidized DLPC, 36.9 min; DLPC hydroperoxide, 35.0 min; DLPC with soybean lipoxygenase, 37.1 min) were observed on the elution profile of the HPLC--ESR analyses of the reaction mixtures. HPLC--ESR--MS analyses of the reaction mixtures gave two ions at m/z 266 and 179, suggesting that 4-POBN/pentyl radical adduct forms in these reaction mixtures.

Chromatography, High Pressure Liquid↗

Development and evaluation of a new method for the determination of the carotenoid content in selected vegetables by HPLC and HPLC-MS-MS.

Epidemologic studies have shown inverse correlation between the consumption of carotenoid-rich vegetables and the incidence of cancer. Therefore, analytical techniques for the quantitative determination of carotenoids in complex sample matrices are important. The most used method is reversed-phase (RP)-high-performance liquid chromatography (HPLC). In this study, seventeen mobile-phase systems described in the literature and six RP-HPLC columns with differences in particle size and porosity are evaluated. Derived from these results, a new mobile-phase (acetonitrile, methanol, chloroform, and n-heptane) including solvent modifiers is presented, which allows an improved and more efficient separation of carotenoids. From all columns tested, the best chromatographic parameters are found using a silica C18 column (250 x 2 mm, 5 microm, 100 A). As was found, absorbance detection at 450 nm allows the determination of the carotenoids down to the picogram range with good linearity (R2 > 0.98). For the identification and quantitation of carotenoids in complex sample matrices (containing additionally other ultraviolet-absorbing compounds), the optimized RP chromatographic system is coupled to a mass spectrometer (MS) using an atmospheric pressure ionization interface. The calibration plots show high linearity (R2 > 0.99), and the detection limit is found in the lower nanogram range. Furthermore, collision-induced dissociation in the ion source allows for the identification of carotenoids by their characteristic fragmentation pathways. In this study, a total of nine species of vegetables commonly consumed in Central Europe are analyzed for their contents of carotenoids (namely lutein, zeaxanthin, beta-cryptoxanthin, and beta-carotene) by RP-HPLC and RP-HPLC-MS-MS. It is found that good sources for lutein are spinach, kale, and broccoli, and sources for beta-carotene are broccoli, spinach, kale, carrots, and tomatoes. This new method is an improvement for the identification and quantitation of carotenoids in complex biological tissues.

Carotenoids↗

Sample pretreatment and determination of non steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and biological samples (blood, plasma, erythrocytes) by HPLC-UV-MS and micro-HPLC.

The article discusses the qualitative and quantitative determination of non-steroidal anti-inflammatory drugs like salicin, salicylic acid, tenoxicam, ketorolac, piroxicam, tolmetin, naproxen, flurbiprofen, diclofenac and ibuprofen by reversed phase high performance liquid chromatography (RP-HPLC) and micro-HPLC (micro-HPLC) hyphenated with UV-absorbance and mass spectrometric detection. Both detection methods delivered calibration plots with good linearity (r(2) > 0.9800), limits of detection in the low nanogram range and recovery rates between 94 and 104 %. For the analysis of biological samples such as blood, plasma and erythrocytes liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the basis of new synthesized glycidylmethacrylate/divinylbenzene copolymer (GMA/DVB) particles and commercially available material on the basis of poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer were investigated. Finally the use of a micro-HPLC system with separation columns in the range of 8 cm x 200 microm I.D. for the determination of non-steroidal anti-inflammatory drugs (NSAIDs) is presented, emphasizing on the type of column and sample amount needed.

Anti-Inflammatory Agents, Non-Steroidal↗

Identification of the major vanilloid component in Capsicum extract by HPLC-EC and HPLC-MS.

A sensitive multi-channel HPLC-electrochemical (EC) method has been developed to determine the vanilloid content in the complex Capsicum annuum extract Capsibiol. Chromatographic separation was achieved within 10 min using a YMC Basic S5 column with a mobile phase containing chloroacetic acid, heptane sulphonic acid and acetonitrile. The multi-channel detector simultaneously applied four potentials between +500 and +800 mV (referenced to a silver/silver chloride electrode) to four glassy carbon working electrodes. The most abundant (0.94 mg/g) vanilloid analogue in the Capsibiol sample demonstrated an electrochemical reactivity and retention time similar to that of vanillic acid in HPLC-EC analysis. Its identity was confirmed by HPLC-MS using a Zorbax SB-CN column with a mobile phase containing formic acid and methanol.

Capsicum↗

HPLC-UV/PAD and HPLC-MS(n) analyses of leaf and root extracts of Vismia guineensis and isolation and identification of two new bianthrones.

In order to evaluate the possible use of the leaves instead of the roots of Vismia guineensis as a new source for the traditional use of this drug, the chemical composition of both organs were compared by HPLC-UV/PAD and HPLC-MS analyses. The leaves are analysed here for the first time. The results show the presence of five major classes of secondary metabolites having specific chromophores: anthraquinones, vismiones, flavonoids, xanthones and benzophenones. The molecular weights and characteristic fragments, compared with previous EI or HPLC-MS literature data, allowed the partial identification of the major peaks in the chromatograms. Six additional isomeric bianthrones and one anthraquinone were detected in the dichloromethane extract of the roots after long storage in solution; the targeted isolation of the bianthrones was performed and enabled the identification of two original C-geranyl derivatives. The chemical compositions of the extracts demonstrated that only a minority of the constituents is shared by both organs. Thus, in order to establish a definitive phytoequivalence, additional pharmacological investigations are required.

Anthracenes↗

Identification of isomeric tropane alkaloids from Schizanthus grahamii by HPLC-NMR with loop storage and HPLC-UV-MS/SPE-NMR using a cryogenic flow probe.

Two fully automated HPLC-NMR methods are reported and compared for the structure elucidation of four isomeric tropane alkaloids from the stem-bark of an endemic Chilean plant, Schizanthus grahamii Gill. (Solanaceae). The first approach interfaced a conventional HPLC column to NMR by means of a loop storage unit. After elution with a mobile phase consisting of deuterated water and standard protonated organic solvents, the separated analytes were momentarily stored in a loop cassette and then transferred one-at-a-time to the NMR flow probe for measurements. The second strategy combined HPLC with parallel ion-trap MS detection and NMR spectroscopy using an integrated solid-phase extraction (SPE) unit for post-column analyte trapping. The SPE cartridges were dried under a gentle stream of nitrogen and analytes were sequentially eluted and directed to a cryogenically cooled flow-probe with an NMR-friendly solvent. The structures of the four isomeric alkaloids, 3alpha-senecioyloxy-7beta-hydroxytropane, 3alpha-hydroxy-7beta-angeloyloxytropane, 3alpha-hydroxy-7beta-tigloyloxytropane and 3alpha-hydroxy-7beta-senecioyloxytropane, were unambiguously determined by combining NMR assignments with MS data.

Chromatography, High Pressure Liquid↗

Determination of flavonoids and stilbenes in red wine and related biological products by HPLC and HPLC-ESI-MS-MS.

To investigate probable health benefits of flavonoids and stilbenes in red wine a new reversed-phase (RP) high-performance liquid-chromatographic (HPLC) method with enhanced separation efficiency and improved selectivity, sensitivity, and speed has been established for determination of the flavonoids quercetin, myricetin and kaempferol and the stilbenes cis- and trans-resveratrol, in a single run . UV-absorbance, fluorescence (FLD), and mass-spectrometric (MS) detection were also evaluated. UV-absorbance detection at 320 nm for stilbenes and 377 nm for flavonoids enables their determination up to the nanogram range with a linearity of R2>0.9999 (linear range 50 ng mL(-1)-50 microg mL(-1)). Calculated values of average recoveries were between 95 and 105% for all analytes. For resveratrol, fluorescence detection was highly selective and twice as sensitive as UV detection, and linearity was satisfactory (R2>0.9996; linear range see UV detection). For the detection of the hydrophilic glycosidic compounds piceid and rutin, which are coeluted with other hydrophilic ingredients, the validated RP HPLC system was coupled to a quadrupole ion-trap mass-spectrometer (MS) via an electrospray interface (ESI) with 25% ammonia solution as sheath liquid. MS detection was, highly linear (R2>0.9878; linear range 50 ng mL(-1)-50 microg mL(-1)) for all investigated analytes and the limits of detection were in the low nanogram range. Compared with UV detection MS detection resulted in a 200% increase in signal intensity for myricetin and 400% increases for quercetin and kaempferol, but equal signal intensity for resveratrol. Calculated values of average recoveries were 102% for myricetin and 79% for piceid. Collision induced dissociation (CID) was also used to obtain characteristic fragmentation fingerprints to facilitate qualitative and quantitative analysis even in complex matrices. Finally, this hyphenated HPLC-ESI-MS method was highly suitable and an essential improvement compared with UV- and fluorescence detection.

Chromatography, High Pressure Liquid↗

Determination of spectinomycin hydrochloride and its related substances by HPLC-ELSD and HPLC-MSn.

A new and simple high-performance liquid chromatography-evaporative light scattering detection (HPLC-ELSD) method for the determination of spectinomycin hydrochloride and its related substances was developed. The column was Agilent SB-C(18) (250 mm x 4.6 mm, 5 microm). The mobile phase was 25 mM trifluoroacetic acid. The drift tube temperature was 40 degrees C. The pressure of nebulizing gas was 3.5 bar. Good separation of spectinomycin from main related substances could be achieved. The standard curve was rectilinear in the range of 0.07-3.8 mg/ml (r = 0.9997). Precision was 1.0% (R.S.D.). The limit of detection was 6 microg/ml. The method is simple and rapid, and the results are accurate and reproducible. The HPLC-MS(n) method was used to characterize the structures of impurities contained in the spectinomycin. In positive mode, impurities were elucidated by use of electrospray ion trap mass spectrometry in the multi-stage MS full scan mode. The possible structures of impurities C and D in spectinomycin were deduced based on the HPLC-MS(n) data.

Anti-Bacterial Agents↗

Simultaneous analysis of eight bioactive compounds in Danning tablet by HPLC-ESI-MS and HPLC-UV.

A high performance liquid chromatography (HPLC) coupled with electrospray tandem mass spectrometry (ESI-MS) and ultraviolet detector (UV) has been developed for the simultaneous analysis of eight bioactive compounds in Danning tablet (including hyperin, hesperidin, resveratrol, nobiletin, curcumine, emodin, chrysophanol, and physcion), a widely used prescription of traditional Chinese medicine (TCM). The chromatographic separation was performed on a ZORBAX Extend C(18) analytical column by gradient elution with acetonitrile and formate buffer (containing 0.05% formic acid, adjusted with triethylamine to pH 5.0) at a flow rate of 0.8 ml/min. The eight compounds in Danning tablet were identified and their MS(n) fractions were elucidated by using HPLC-ESI-MS, and the contents of these compounds were determined by using HPLC-UV method. The standard calibration curves were linear between 5.0 and 100 microg/ml for hyperin, 10-200 microg/ml for hesperidin, 1.0-150 microg/ml for resveratrol, 2.0-120 microg/ml for nobiletin, 2.0-225 microg/ml for curcumine, 20-300 microg/ml for emodin, 2.0-200 microg/ml for chrysophanol, and 20-250 microg/ml for physcion with regression coefficient r(2)>0.9995. The intra-day and inter-day precisions of this method were evaluated with the R.S.D. values less than 0.7% and 1.3%, respectively. The recoveries of the eight investigated compounds were ranged from 99.3% to 100.2% with R.S.D. values less than 1.5%. This method was successfully used to determine the 8 target compounds in 10 batches of Danning tablet.

Calibration↗

Determination of heterocyclic aromatic amines in food products: automation of the sample preparation method prior to HPLC and HPLC-MS quantification.

Heat-processing protein-rich foods may cause the formation of heterocyclic aromatic amines (HAAs), all of which have mutagenic and some also carcinogenic potential. Accurately measuring HAA levels in food products is therefore a necessary to realistically assess this risk factor. A solid-phase extraction method for quantitative HAA analysis has been developed by us over the last few years. This method has recently been automated using a robotic workstation and now allows almost unattended sample preparation, a process which saves a human operator about five hours of benchwork. Cleaned-up samples were analyzed by high performance liquid chromatography (HPLC) and ultraviolet (UV) or mass spectrometric (MS) detection. While HPLC-UV remains the daily tool to quantify HAAs, we found HPLC-electrospray-MS to be an alternative detection method with unique advantages, suited for both HAA identification and quantification.

Amines↗