Laryngospasm during transtracheal high frequency jet ventilation.

A 74-year-old woman developed severe cardiovascular depression during percutaneous transtracheal high frequency jet ventilation for laser surgery of the epiglottis. This was found to be caused by acute airway obstruction secondary to severe laryngospasm. We recommend profound neuromuscular blockade during percutaneous transtracheal jet ventilation, in order to prevent this complication.

Aged↗

Removal of a laryngeal foreign body using high frequency jet ventilation.

Aspiration of a foreign body into the respiratory tract is a common and serious accident in childhood. Laryngotracheal foreign bodies, although less common than bronchial foreign bodies, are potentially more dangerous. Removal is commonly achieved using a rigid ventilating bronchoscope. We report a 16-month-old boy who had an open safety pin impacted in his larynx. This was removed through a tracheostomy, using high frequency jet ventilation to maintain gaseous exchange. We believe that this is the first case in which this method of removal has been reported.

Bronchoscopy↗

High frequency jet ventilation for microlaryngeal laser surgery. An improved technique.

The use of a triple lumen central venous catheter, which can be shielded from laser irradiation by metal tape, as a conduit for high frequency jet ventilation in six children, is described. The problems of anaesthesia for laryngeal laser surgery and the advantages of the technique described in this paper are discussed.

Catheterization, Central Venous↗

[Anesthesia technique for laser surgery in the region of the larynx].

Laser surgery can be performed using either endotracheal intubation, apnoea or jet ventilation. For operations performed under endotracheal intubation the same technical rules apply as for any other type of anaesthesia. To facilitate intubation a special laser tube is required. The Mallinckrodt Laser-Flex Tracheal Tube has the best physical qualities of all endotracheal catheters available commercially. Aspiration prophylaxis using ranitidin and metoclopramide is recommended for procedures under apnoea or using jet ventilation. For monitoring purposes during jet ventilation or procedures under apnoea, transcutaneous oximetry, ECG recording as well as non-invasive blood pressure measurements at short intervals is mandatory. In addition video monitoring is desirable to allow visual anaesthesiological surveillance of the larynx. The jet ventilator must meet established standards; the option must be available to survey inspiratory peak pressure and end-exspiratory pressure as well as the setting of appropriate alarm limits.

Anesthesia, Endotracheal↗

Innovations in cardiopulmonary care of the low-birth-weight infant.

The purpose of this article is to review innovations in cardiopulmonary care of the high-risk, low-birth-weight infant. Recommendations are based on physiologic principles and a review of the research literature. The major problem experienced by the low-birth-weight neonate is respiratory distress syndrome (RDS); traditional treatment is discussed. Strategies for prevention, including antenatal corticosteroid administration and surfactant replacement, are described. Alternative methods of ventilatory support, including high-frequency ventilation and extracorporeal membrane oxygenation, are detailed. Finally, treatment of bronchopulmonary dysplasia (BPD) and recommendations for prevention are delineated.

High-Frequency Jet Ventilation↗

[Transtracheal jet ventilation in the operating room].

For the last 40 years transtracheal ventilation has been suggested as a means of bypassing the glottis in emergency in patients unable to be intubated or ventilated by mask. A catheter has been designed to be easily inserted into the crico-thyroid membrane. The outer part of the device, with its dual attachment system, can be connected to conventional resuscitation equipment by its 15 mm male end or to a high-pressure oxygen source by its Luer-Lock fitting. The advantages of transtracheal ventilation are: a clear vision of the operative field, a good gas exchange, an elimination of airway trauma from intubation, a reduction of the hazard of airway fires and a decreased risk of aspiration of blood and debris. Barotrauma is the main danger. However, this method of providing oxygen and/or mechanical ventilation may be extended to the postoperative period, the exit of the insufflated gas mixture being assured at all times.

Anesthesia, Inhalation↗

[Effective high frequency jet ventilation setting for the preparation of internal thoracic artery for coronary artery bypass graft surgery].

Effective high frequency jet ventilation (HFJV) setting during the preparation of internal thoracic artery (ITA) was estimated in 35 patients who underwent coronary artery bypass graft (CABG) surgery. During ITA preparation, ventilation with the minimum lung movement without circulatory deterioration is necessary. Therefore, appropriate frequency, inspiratory time interval (Ti%) and working pressure (WP) for HFJV were investigated. Rising WP and prolonged Ti% provoked increasing tidal volume and decreasing PaCO2, whereas the lung extension disturbed the ITA preparation. By modifying the settings of frequency, Ti% and WP, we determined the frequency of 3Hz and Ti% of 50%. The correlation between WP at normocapnia and bodyweight (BW) is expressed in the following formula: WP = 0.16 x BW - 0.0003 (r = 0.72) Moreover satisfactory recording of end-tidal CO2 could not be obtained during HFJV. Therefore, we used transcutaneous CO2 (tc-CO2) analyzer. The coefficient between tc-CO2 and PaCO2 was 0.95, and tc-CO2 was useful as a non-invasive monitoring of PaCO2. There was little change in blood pressure, heart rate and cardiac output during HFJV. However mean pulmonary artery pressure (mPAP) increased significantly during hypercapnia especially when PaCO2 was over 50 mmHg. This suggests that mPAP may be more sensitive to PaCO2 compared with other circulatory parameters. HFJV with these settings produced good outcome for ventilation and circulation during the preparation of ITA.

Adolescent↗

Elective transtracheal jet ventilation for bronchoscopic removal of tracheal foreign body.

We have shown that transtracheal jet ventilation can be used safely and effectively when removing a foreign body from the airway. In some cases, it may be wise to choose this method of ventilation initially, thus avoiding the difficulties associated with more conventional modes of controlled ventilation. This is especially true when the potential for loss of the airway during the procedure is significant. This technique also allows the bronchoscopist the benefit of unimpeded access to the airway and adequate uninterrupted time for his operative procedure.

Bronchoscopy↗

An experimental randomized study of five different ventilatory modes in a piglet model of severe respiratory distress.

OBJECTIVES: To characterize different modes of pressure- or volume-controlled mechanical ventilation with respect to their short-term effects on oxygen delivery (DO2). Furthermore to investigate whether such differences are caused by differences in pulmonary gas exchange or by airway-pressure-mediated effects on the central hemodynamics. DESIGN: After inducing severe respiratory distress in piglets by removing surfactant, 5 ventilatory modes were randomly and sequentially applied to each animal. SETTING: Experimental laboratory of a university department of Anesthesiology and Intensive Care. ANIMALS: 15 piglets after repeated bronchoalveolar lavage. INTERVENTIONS: Volume-controlled intermittent positive-pressure ventilation (IPPV) with either 8 or 15 cmH2O PEEP; pressure-controlled inverse ratio ventilation (IRV); pressure-controlled high-frequency positive-pressure ventilation (HFPPV) and pressure-controlled high frequency ventilation with inspiratory pulses superimposed (combined high frequency ventilation, CHFV). The prefix (L) indicates that lavage has been performed. MEASUREMENTS AND RESULTS: Measurements of gas exchange, airway pressures, hemodynamics, functional residual capacity (using the SF6 method), intrathoracic fluid volumes (using a double-indicator dilution technique) and metabolism were performed during ventilatory and hemodynamic steady state. The peak inspiratory pressures (PIP) were significantly higher in the volume-controlled low frequency modes (43 cmH2O for L-IPPV-8 and L-IPPV-15) than in the pressure-controlled modes (39 cmH2O for L-IRV, 35 cmH2O for L-HFPPV and 33 cmH2O for L-CHFV, with PIP in the high-frequency modes being significantly lower than in inverse ratio ventilation). The mean airway pressure (MPAW) after lavage was highest with L-IRV (26 cmH2O). In the ventilatory modes with a PEEP > 8 cmH2O PaO2 did not differ significantly and beyond this "opening threshold" MPAW did not further improve PaO2. Central hemodynamics were depressed by increasing airway pressures. This is especially true for L-IRV in which we found the highest MPAW and at the same time the lowest stroke index (74% of IPPV). CONCLUSIONS: In this model, as far as oxygenation is concerned, it does not matter in which specific way the airway pressures are produced. As far as oxygen transport is concerned, i.e. aiming at increasing DO2, we conclude that optimizing the circulatory status must take into account the circulatory influence of different modes of positive pressure ventilation.

Airway Resistance↗

Recovery of tracheal epithelium following high frequency ventilation at low inspired humidity.

We used scanning electron microscopy (SEM) and light microscopy (LM) to study the recovery of tracheal epithelium in newborn lambs damaged by high frequency flow interrupted ventilation (HFFIV) at low inspired humidity (30%). Newborn lambs were mechanically ventilated for 6 h, allowed to recover and subsequently killed at 2, 7 or 14 days. The recovery of the trachea above and below the tip of the endotracheal tube (ETT) was studied at these time periods and compared to a control non-intubated group and a group killed immediately after 6 h of ventilation. Above and below the ETT, SEM and LM revealed deciliation to be greatest 2 days after ventilation. The damaged tracheal mucosa had converted to non-ciliated epidermoid squamous metaplastic cells. Recovery was not complete by 14 days, although the squamous cells had already differentiated into goblet and ciliated columnar epithelial cells. No difference was seen in the rate of recovery of the tracheal mucosa above or below the tip of the ETT.

Animals↗

Clinical studies on high frequency two-way jet ventilation.

A new mode of jet ventilation, high frequency two-way jet ventilation (HFTJV) was devised and introduced to increase carbon dioxide elimination during jet ventilation. Its ventilatory efficiency and features were investigated and compared with those of high frequency jet ventilation (HFJV) in 10 patients with normal cardiopulmonary function. Random sample selection and randomized cross-over trial were used for comparison between HFTJV and HFJV at the same ventilatory settings of driving pressure 1 kg/cm2 (14.22 Psi), respiratory rate 100/min and I/E ratio 1:2. Peak inspiratory pressure (PIP), end-expiratory pressure (EEP) and main variables of air blood gas analysis (PaO2, PaCO2, pH) were measured and recorded during the use of HFJV and HFTJV. PIP and EEP were significantly lower than with HFTJV than with HFJV. EEP of HFTJV showed a slightly negative pressure (-0.17 +/- 0.03 kPa). PaCO2 with HFTJV was significantly lower than that with HFJV, but PaO2 and pH with HFTJV were significantly higher than those with HFJV. HFTJV was shown to have a ventilatory feature of decreasing airway pressure and simultaneously increasing carbon dioxide elimination, as compared with HFJV. Whether this ventilatory feature of HFTJV can be utilized for various respiratory support in patients with abnormal cardiopulmonary function needs to be further studied.

Adult↗

Anesthetic concerns and complications during suspension microlaryngoscopy procedures.

The use of lasers during microsurgery on the larynx is becoming more commonplace in the operating rooms of many hospitals. Because of the intense cardiovascular response to suspension microlaryngoscopy and the short duration of these cases, the anesthesia provider is faced with one of the most challenging anesthetic cases. This article includes a brief introduction to suspension microlaryngoscopy, a case study, a description of suspension microlaryngoscopy, and the anesthetic concerns and possible complications of importance during suspension microlaryngoscopy.

Anesthesia, General↗

[Application of high frequency jet ventilation during microsurgery of the larynx under suspending laryngoscopy].

OBJECTIVES: This study describes the results obtained with high frequency jet ventilation (HFJV) in 19 patients who underwent laryngeal microsurgery under suspending laryngoscopy. MATERIAL AND METHODS: After premedication and anesthetic induction with propofol (Diprivan R, ICI-Farma), we performed an endotracheal intubation (28F tube) under succinyl-choline facilitation. Conventional ventilation was started at a rate of 14-16 cpm with a minute volume of 8-10 l, and a FiO2 of 0.4 (air-oxygen). The endotracheal tube was replaced by an insufflation catheter of 2 mm internal diameter and HFJV was initiated at a rate of 100 cpm, inspiratory time equal to the 33% of the total cycle, generator pressure of 2.5-3.6 kg/cm2, and similar FiO2. We used an Ergojet CVT (Temel SA) respirator that allowed continuous monitoring of the injector released volume during each cycle (Vjet) as well as the air way pressure. Anesthesia was maintained with continuous propofol perfusion. RESULTS: During HFJV there were no significant hemodynamic alterations and surgeons considered that the condition of the surgical field was excellent. Air way pressure was maintained at low levels in all cases, although brief hypertensive episodes occurred during laryngeal manipulation. Oxygenation was satisfactory in all except one patient with chronic obstructive pulmonary disease. Conventional ventilation and HFJV did not induce significant differences in alveolar ventilation nor in PaCO2. However, during HFJV oxygenation and ventilatory levels suffered a high degree of interindividual variability. This phenomenon could be due to the existence of variable degrees of gas reflux during insufflation. CONCLUSIONS: We conclude that HFJV is a very useful technique for anesthesia in laryngeal microsurgery. However, an appropriate monitoring of ventilatory dynamics and a detailed knowledge of the influences of patient's characteristics on HFJV are required.

Adult↗