PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Iud Expulsion”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Immediate postpartum IUD insertions in a Chinese hospital--a two year follow-up.

A data set consisting of 199 immediate postpartum IUD insertions performed at the Xuan Wu Hospital, Beijing, China was analysed in terms of insertion route, category of inserting personnel and device type. IUD expulsion and continuation of use were the outcome events of interest in this study. Based on our findings, the following hypotheses were derived for future confirmative studies: lower expulsion rates and hence, higher continuation rates of immediate postpartum IUD insertions are associated with (1) insertions through the abdominal incision wound for women who had a cesarean delivery as compared to immediate (less than 10 min) vaginal insertions in women with vaginal delivery; (2) obstetrician insertions, as compared to midwife insertions, and (3) use of the Delta T, as compared to that of the Delta Loop. For the derivation of the latter two hypotheses, only the vaginal insertions were studied.

Adult↗

A clinical trial of the Delta-T intrauterine device: immediate postpartum insertion.

The Copper T-220C intrauterine device was modified for use in early postpartum insertions. Biodegradable extensions consisting of No. 2 chromic suture were added to the horizontal arms of the device to enhance retention. This new device, Delta-T IUD, was inserted in 100 patients within 55 hours of the delivery of the placenta. No uterine perforations or cervical lacerations occurred in this study. There was one accidental pregnancy 4 months following the IUD insertion. Seven IUDs were removed for bleeding and pain. There was one case of postpartum endometritis. Seventeen IUD expulsions occurred. Expulsions were more frequent at the beginning of the study and when the IUD was inserted more than 30 minutes after delivery of the placenta. The immediate postpartum insertion of IUDs with the event rates observed in this study is acceptable in situations where alternatives for other family planning modalities or interval insertion of intrauterine devices are not feasible.

Adolescent↗

Treatment of adenomyosis-associated menorrhagia with a levonorgestrel-releasing intrauterine device.

OBJECTIVE: To evaluate the efficacy and tolerability of treatment with a levonorgestrel-releasing intrauterine device (IUD) in women affected by adenomyosis-associated menorrhagia. SETTING: Tertiary care center. DESIGN: Prospective, open, noncomparative study. PATIENT(S): Twenty-five women aged 38 to 45 years with recurrent menorrhagia associated with adenomyosis diagnosed at transvaginal ultrasonography participated in this study. INTERVENTION(S): An IUD releasing levonorgestel 20 mcg/day was inserted in each patient within 7 days of the start of menstrual flow. All of the patients were requested to compile a pictorial blood loss assessment chart each month. They underwent clinical and transvaginal ultrasound examinations 3, 6, and 12 months after IUD insertion. MAIN OUTCOME MEASURE(S): Menstrual pattern; serum hemoglobin, ferritin, and iron level changes. RESULT(S): One patient experienced IUD expulsion 2 months after device insertion and another requested removal of the IUD 4 months after insertion because of persistent irregular blood loss. Six months after IUD insertion, amenorrhea was observed in 2 patients and oligomenorrhea in another, spotting occurred occasionally in 7, and 13 had scanty but regular flow. One year of follow-up has been completed by the remaining 23 women: 2 with amenorrhea, 3 with oligomenorrhea, 2 with spotting, and 16 with regular flows. Significant increases in hemoglobin, hematocrit, and serum ferritin have been observed, but the lipid metabolism and clotting variables have remained unchanged. CONCLUSION(S): Our findings indicate that marked and safe relief from adenomyosis-associated menorrhagia can be obtained with the use of a levonorgestrel-releasing IUD.

Adult↗

[Evaluation of the usefulness of ultrasonography in the insertion and control of the intrauterine device].

The usefulness of ultrasonography in IUD insertion and control, was evaluated. A follow up of IUD localization, placed at the end of puerperium and in non puerperal patients, was done. The copper T IUD 200 was used, and was placed in 50 patients. Ultrasonographic study was done right after IUD placement, at one month and at three months; uterine longitudinal sections, as well as transversal ones, for adequate localization of IUD; data were taken for control and followup. There were no IUD expulsion, pregnancy, or uterine perforation. Conclusions were: 1. Ultrasonography is useful for IUD control. 2. IUD placement at the hospital is adequate. 3. There were no complications. 4. Alterations produced by IUD insertion are more frequent during the first month, and very scarce at third month. 5. Dysmenorrhea was most frequent after IUD insertion. 6. Echosonographic control of IUD is the most accurate method in order to know its localization within the uterine cavity.

Adolescent↗

Menstrual problems and side effects associated with long-term TCu 380A IUD use in perimenopausal women.

The study assessing menstrual problems and side effects associated with long-term TCu 380A intrauterine device (IUD) use in perimenopausal women is reported. Fifty perimenopausal TCu 380A IUD acceptors who had IUD inserted after age 40 and used IUD at least 36 months were recruited. The mean age of acceptors at time of insertion was 44.2 years with an average parity of two live births. The mean body weight at insertion was 62.13 kg. Most of the bleeding patterns were regular cycles. Intermenstrual bleeding and pelvic pain were side effects most often reported. No pregnancies, pelvic inflammatory disease, or IUD expulsions occurred during the follow-up period. This study suggests that the use of TCu 380A IUD in perimenopausal women is safe and effective.

Adult↗

The efficacy of immediate post-abortion intrauterine device insertion.

Ovulation returns soon after abortion, with half of the women ovulating by 21 days after the procedure. Immediate post-abortion insertion provides immediate contraceptive protection. Clinicians have feared that rates of uterine perforation due to intrauterine devices (IUDs) and expulsion of IUDs may be higher in the post-abortal uterus due to its softness and enlargement. This study was carried out to assess the safety and efficacy of IUD insertion immediately after induced abortion compared with insertion during the first menstrual cycle after abortion. All women were counseled about a method of contraception, particularly copper T-380A, and divided into two groups: Group 1 included 226 women who preferred immediate IUD insertion, and Group 2 included 100 women who opted for interval-IUD insertion during the first menstrual cycle after abortion. All women were followed-up at two and eight weeks after insertion of the IUDs. Severe bleeding was observed 10.62% in Group 1 and 6% in Group 2. Expulsion rate was 7.08% and 8% in Groups 1 and 2, respectively, which was not statistically significant. Pelvic inflammatory disease (PID) was observed in one case in Group 1. However uterine perforation was not noted in either group. In conclusion, insertion of an IUD immediately after an induced abortion is safe and if a woman asks for a modern contraceptive method it could be offered.

Abortion, Induced↗

Use of sexually transmitted disease risk assessment algorithms for selection of intrauterine device candidates.

Sexually transmitted diseases (STD) are an important contraindication for intrauterine device (IUD) insertion. Nevertheless, laboratory testing for STD is not possible in many settings. The objective of this study is to evaluate the use of risk assessment algorithms to predict STD and subsequent IUD-related complications among IUD candidates. Among 615 IUD users in Kenya, the following algorithms were evaluated: 1) an STD algorithm based on US Agency for International Development (USAID) Technical Working Group guidelines: 2) a Centers for Disease Control and Prevention (CDC) algorithm for management of chlamydia; and 3) a data-derived algorithm modeled from study data. Algorithms were evaluated for prediction of chlamydial and gonococcal infection at 1 month and complications (pelvic inflammatory disease [PID], IUD removals, and IUD expulsions) over 4 months. Women with STD were more likely to develop complications than women without STD (19% vs 6%; risk ratio = 2.9; 95% CI 1.3-6.5). For STD prediction, the USAID algorithm was 75% sensitive and 48% specific, with a positive likelihood ratio (LR+) of 1.4. The CDC algorithm was 44% sensitive and 72% specific, LR+ = 1.6. The data-derived algorithm was 91% sensitive and 56% specific, with LR+ = 2.0 and LR- = 0.2. Category-specific LR for this algorithm identified women with very low (< 1%) and very high (29%) infection probabilities. The data-derived algorithm was also the best predictor of IUD-related complications. These results suggest that use of STD algorithms may improve selection of IUD users. Women at high risk for STD could be counseled to avoid IUD, whereas women at moderate risk should be monitored closely and counseled to use condoms.

Adult↗

Two years of experience with the Multiload Cu375 in Georgia.

This study was conducted to evaluate the clinical performance of the Multiload Cu375 IUD in 157 healthy women, aged 18-38 years, who had regular sexual intercourse and who wished to avoid pregnancy. The period of observation was 2 years. During 24 months, pain and bleeding was noted in 7 patients (4.4%); IUD expulsion was observed in 4 cases (2.5%) and there was only 1 case (0.6%) of pregnancy. Our conclusion is that the Multiload Cu375 is an excellent method of contraception.

Adolescent↗

Role of endoscopy in retrieval of misplaced intrauterine device.

We report a series of 45 patients with misplaced intrauterine devices (30 extrauterine and 15 intrauterine). Only those patients with intrauterine misplacements in whom conventional blind removal was not possible were included in the study. All of the 15 misplaced intrauterine devices could be removed hysteroscopically; 22 of the 30 extrauterine misplaced devices (73%) could be removed laparoscopically. One patient required both laparoscopy and hysteroscopy. Only 7 (15.5%) of 45 patients required laparotomy for safe removal of misplaced devices. Considerable comfort and minimal hospital stay associated with endoscopic procedures should offer these as the first line attempt to remove a misplaced intrauterine or extrauterine translocated device.

Adult↗

[Modern intra-uterine contraception: a better option].

Users of oral contraceptives have an increased risk of developing venous thromboembolism as well as mammary cancer. This raises the question as to whether locally applied (intrauterine) contraceptives can offer a valuable alternative with respect to efficiency and safety. During the past decade the use of modern intrauterine devices (IUDs) has made substantial progress in comparison with the use of IUDs during the 1970s and 1980s. Modern IUDs have become more efficient than oral contraception. Arguments against the use of IUDs (problems and complications in IUD insertion, the risk of pelvic inflammatory disease, ectopic pregnancy and infertility as well as side effects such as menorrhagia, pelvic cramps and IUD expulsion) generally appear to be based on a lack of awareness with respect to recent developments and on misunderstandings derived from bad experiences during the 1980s and earlier.

Contraception↗

Performances of copper T 380A and multiload copper 375/250 intrauterine contraceptive devices in a comparative clinical trial.

An evaluation of the performances of copper T 380A (TCU 380A) and multiload copper 375/250 (MLCU 375/250) intrauterine contraceptive devices (IUCDS) was carried out at University College Hospital, Ibadan, Nigeria (UCH) in a clinical comparative trial. The IUCDS showed similar low vent rates at one year of continuous use. The difference in cumulative net probabilities for termination due to pelvic inflammatory disease was weakly significant at the sixth month of follow up with MLCU 250 having the highest rate. (TCU 380A-0%; MLCU 375-0%; MLCU 250-3.1%; X2 = 6.0; P < 0.05). This significant difference disappeared by the twelfth month of continuous use. Likewise, the difference in cumulative net probabilities for overall termination was significant at six months and insignificant at twelve months of follow up. The continuation rate after one year were 86%, 92% and 87% respectively for TCU 380A, MLCU 375 and MLCU 250. These rates were higher than 80% and 51% quoted for the previously available Lippes loop in the same environment [1,2]. It was therefore concluded that the three IUCDS are comparable in performances in the first year of use and could be used at our family planning clinic or any other clinic in a similar setting.

Adult↗

[A study to lower the expulsion rate of IUDs].

The author has been investigating why the shape and size of the IUD must be suitable to the geometric size and shape of the endometrial cavity. Women vary greatly in the shape and size of the endometrial cavity. When any woman needs to use an IUD, one should measure the transverse as well as the longitudinal diameter of the endometrial cavity at the fundus. One cannot simply depend on the longitudinal length of the vertical axis of the endometrial cavity in choosing the diameter of the ring. The author always uses the uterine metrology device of the GCH-I types to select the diameter of the ring. 1561 women who were wearing IUDs were measured and the probe was used to measure the vertical axis of the endometrial cavity for 1355 women. The women were followed for 3 years. The rate of expulsion of IUDs in the former was 3.9%, and in the latter 6.0. Particularly, the rate of removal in the former because of disease was much lower. There was a marked difference between the two.

Contraception↗

Immediate post-placental IUD insertion: the expulsion problem.

This paper reports an evaluation of immediate post-placental insertion of a non-copper (Lippes Loop D) and several copper-bearing IUD models (TCu200, TCu220C, MLCu375, MLCu250, Nova T-PP, DimélysR). Based on the analysis of a total of 2,646 insertions and 55,794 woman-months of experience, we conclude that placement of an IUD within ten minutes of delivery of the placenta is a valuable alternative to interval insertion, because this method is safe and effective. Effectiveness was significantly lower for the Lippes Loop D than for the T- and ML-IUD models tested, the latter showing roughly comparable pertinent event rates. Pertinent event rates for copper IUDs were influenced by the skill of the operator; age of the recipient only had a significant effect on effectiveness, whereas parity had no significant effect on pertinent event rates. The single and still unsolved problem associated with immediate postpartum insertion is the greater likelihood of expulsion compared with interval insertion, and this hazard is significantly much greater for the Loop than for the copper-bearing devices assessed. The evolution of the expulsion rates shows a constant time-relationship. This pattern makes it obvious why follow-up of recipients, at least during the first trimester following insertion, is mandatory if immediate post-placental IUD insertion is to be optimally effective.

Adult↗

IUD insertion following induced abortion.

In a multicenter survey, women who received an IUD immediately after abortion were compared with abortion patients who started using oral contraception. Additionally, women receiving a Nova T were compared with women receiving a Multiload 250. Follow-up data were gathered after 6 weeks. Pain was a common phenomenon post-abortum. In the study group of IUD users, complaints about pain were not more frequent than among controls, but if pain was experienced, it was more intense and of longer duration among IUD users. Bleeding immediately following the induced abortion was less frequent among IUD users, but if bleeding occurred, it tended to last longer. The first menstrual period after the induced abortion was heavier and more painful among IUD users. Expulsion of the IUD occurred in 10 cases (3.3%), all of them with the Nova T, none with Multiload. The study did not generate evidence for an increased risk of PID in women receiving an IUD after an induced abortion.

Abortion, Induced↗

Cross of Lorraine and Cross of Caravaca: new IUD's with low expulsion rates.

The Cross of Caravaca and Cross of Lorraine IUDs with double horizontal bar design were developed in an attempt to reduce expulsion and removal rates for pain and bleeding encountered with other IUDs. The devices were manufactured in radio-opaque plastic bearing copper wire or sleeves on the top arm. The Cross of Lorraine has the upper arm shorter than the lower arm whereas in the Cross of Caravaca the shorter is the lower arm. 748 women had insertion of the Cross of Caravaca and 412 had insertion of the Cross of Lorraine. For the Cross of Caravaca 486 women completed 1 year of use, 392 completed 2 years and 310 completed 3 years. For the Cross of Lorraine, 268 women completed the 1st year, 205 the 2nd, and 150 women completed 3 years of use. The combined number of observed months of use for the 2 devices at the end of 3 years was 24,963. Accidental pregnancy rates at the end of 3 years were 1.13% for Caravaca and 3.48% for Lorraine. Expulsion rates at the end of 3 years were nil for the Cross of Lorraine and 1.16% for the Cross of Caravaca. Pain and bleeding were the most common causes of termination for medical reasons, bleeding accounting for termination in 1.66% of Lorraine users at the end of 3 years of use and 2.75% of Caravaca users. Pain accounted for termination in 3.14% of Caravaca users and 2.02% of Lorraine users. Incidence of infection was 0.42% and nil for Caravaca and Lorraine users respectively. Total discontinuation rates at the end of 3 years were 25.39% for Caravaca and 16.67% for Lorraine.

Americas↗

The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion.

A total of 235 women who had a TCu 380A IUD inserted had a vaginal ultrasound scan performed to identify if the IUDs were correctly placed in the uterine fundus. Women identified as having a misplaced IUD had it removed. The remaining women were compared to 201 women who had an IUD inserted and had no ultrasound evaluation, matched by age and parity. Women were followed-up for one year. Gross cumulative discontinuation rates and continuation rates were calculated by life table analysis. Comparison between groups was done by the Gehan test. The study group had 34 IUDs removed because they were misplaced according to the established criteria. The expulsion rate was significantly higher in the control group, also influencing the continuation rate which was lower in the same group. Of the 34 women who had their IUD removed because it was not correctly placed, only 22 requested and had another IUD inserted. The removal of IUD determined by an ultrasound to be incorrectly placed significantly decreased expulsion rates. However, many IUDs may have been removed unnecessarily, probably resulting in many women not returning to the clinic or deciding to use another contraceptive method.

Adult↗

Study on the factors associated with contraceptive discontinuations in Bangkok.

Detailed information was collected from 666 cohorts of pill, injectable-DMPA and IUD acceptors at 14 Bangkok Metropolis Health Clinics (MHCs). The contraceptive status at 12-month follow-up home interview shows that 47% of pill acceptors, 39% of DMPA acceptors and 55% of IUD acceptors were still using the same contraceptive method and receiving them from the original source. The women who initially adopted the pill could seek the oral contraceptive from other sources with a higher significant percentage (14%) than was found in the DMPA and IUD group. The DMPA group revealed the lowest percent of using same method and same source but higher rate of clinic switch (15%), including method and clinic switch (18%), than the pill and IUD acceptors. The women who adopted the pill had stopped using any contraceptive method with the highest percentage (31%). The main reason for method switch among the three contraceptive acceptors was disagreeable health effects; 50% of pill acceptors, 75% for DMPA acceptors and 49% for IUD acceptors. Another important reason for IUD switch was a 32% expulsion of IUD. Those who switched clinic gave the three important reasons of distance inconvenience, opening hour inconvenience and disagreeable health effects. Service-related factors are likely to play a less important role in determining discontinuation of the pill and DMPA, while the reasons on doctors objecting to removing the IUD appear to be the major service-related factor in discontinuation of IUD (19%). The decision to stop using any contraceptive appeared to be related to dissatisfaction with the method and side effects was the primary reason and the secondary reason was that they wanted another child.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗