PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “LUBRICATION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

The role of synovial fluid filtration by cartilage in lubrication of synovial joints--III. Squeeze-film lubrication: axial symmetry under low loading conditions.

A mixture model of synovial fluid filtration and synovial gel formation at normal approach of cartilage surfaces in the human synovial joints loaded by a compressive force has been recently presented in Parts I and II of this paper (Hlavácek, 1993, J. Biomechanics 26, 1145-1150; 1151-1160). In the model synovial fluid is taken as a mixture of two incompressible fluids (ideal and Newtonian viscous), while the biphasic model of Mow et al. (1980, J. Biomech. Engng 102, 73-84) is used for cartilage. A system of partial differential equations for the normal approach of axially symmetric cartilage surfaces in the human hip joint obtained in Part II is solved numerically for low loads. A shallow pocket-type configuration of the synovial film is formed shortly after the load application at time t = 0. For constant loads the fluid film pressure profile follows very closely that in a dry frictionless contact. To this approximation and with the exception of a close vicinity of the squeeze-film edge the flux of the ideal fluid across the synovial fluid-cartilage interface varies quadratically with the radial distance r and decreases as t-1/2 with time. The ideal fluid is forced into cartilage at the central region and out of cartilage at the low-pressure periphery of the squeezed synovial film. The maximum gel-forming concentration (the 20-fold of the original value) of the hyaluronic acid-protein macromolecular complex of the synovial fluid is reached at the film centre first, then the gel film starts spreading quickly sideways. Later, the process slows down approaching the value r/2 1/2 where r is the radius of a dry frictionless contact. The final gel-film thickness decreases very slowly with the increasing r for 0 < or = r < r/2 1/2.

Biomechanical Phenomena↗

Comparison of friction and lubrication of different hip prostheses.

It is well documented that an important cause of osteolysis and subsequent loosening of replacement hip joints is polyethylene wear debris. To avoid this, interest has been renewed in metal-on-metal and ceramic-on-ceramic prostheses. Various workers have assessed the lubrication modes of different joints by measuring the friction at the bearing surfaces, using different lubricants. Measurements of friction factors of a series of hip prostheses were undertaken using carboxymethyl cellulose (CMC) fluids, silicone fluids, synovial fluid and different concentrations of bovine serum as the lubricant. The experimental results were compared with theoretical predictions of film thicknesses and lubrication modes. A strong correlation was observed between experiment and theory when employing CMC fluids or silicone fluids as the lubricant. Mixed lubrication was found to occur in the metal-on-metal (CoCrMo/CoCrMo) joints with all lubricants at a viscosity within the physiological range. This was also the case for the metal-on-plastic (CoCrMo/ultra-high molecular weight polyethylene) joints. The ceramic-on-ceramic (Al2O3/Al2O3) joints, however, exhibited full fluid film lubrication with the synthetic lubricants but mixed lubrication with the biological lubricants. Employing a biological fluid as the lubricant affected the friction to varying degrees when compared with the synthetic lubricants. In the case of the ceramic-on-ceramic joints it acted to increase the friction factor tenfold; however, for the metal-on-metal joints, biological fluids gave slightly lower friction than the synthetic lubricants did. This suggests that, when measuring friction and wear of artificial joints, a standard lubricant should be used.

Adsorption↗

The impact of lubricants on latex condoms during vaginal intercourse.

The objective was to evaluate the impact of additional lubricant on condom breakage and slippage. Two hundred and sixty-eight couples used 6 new and 6 aged condoms during vaginal intercourse and were instructed to use 2 of each type with either water-based lubricant, oil-based lubricant or no additional lubricant. The use of either oil-based or water-based lubricant increased slippage rates of new and aged condoms, although only one pairwise comparison (oil-based lubricant vs. no additional lubricant) was statistically significant (8.5% vs. 3.8%, P = 0.004). The use of oil-based lubricant increased breakage, although not statistically significantly, in both new and aged condoms. Water-based lubricant did not impact the breakage rate of the new condoms and decreased the breakage rate of the aged condoms (no additional lubricant 4.5% vs. water-based lubricant 2.1%, P = 0.029). From a functional perspective, this study suggests that condom users should be told not to use oil-based lubricants. The negative impact of water-based lubricant on slippage may be outweighted by the protective influence on breakage, especially for aged condoms. Over three-quarters of the couples (76%) had at least some incorrect knowledge, according to current condom instructions, of the type of lubricant that should be used with condoms.

Adult↗

Does additional lubrication affect condom slippage and breakage?

The risk of condom slippage (1.94%) and breakage (0.89%) among 3607 condoms was analysed with respect to the use of additional lubricant. Whether or not lubricant was used, the site at which it was applied and the type of lubricant used were all found to vary significantly with the type of sexual act(s) for which the condoms were used. Little evidence was found for differing effects of type of additional lubricant (water-based, saliva or other) or site of lubricant use (on penis/inside condom, on condom, in vagina/anus). The use of lubricant more than doubles the risk of slippage for vaginal sex. While anal sex is associated with much higher risks of slippage the use of lubricant for this practice actually reduces the risk of slippage to that similar for vaginal sex where lubricant is used. No significant effect of additional lubricant on condom breakage was observed. It is recommended that education messages concerning the use of additional lubricant may need to change to take into account the varied nature of lubricant use practices and the differential effects of lubricant with respect to sexual practices. Specifically, if the use of additional lubricant has little or no impact on condom breakage but increases condom slippage then encouraging its use may be counterproductive if condom users consider slippage to be a reason not to use condoms.

Adult↗

[Identification of automotive lubricants and other heavy oils by isotachophoresis].

Automotive lubricants were analysed by isotachophoresis for the purpose of identification of lubricants and suspected stains adhered to victims in traffic accidents. As the results, it was found that each lubricant showed a characteristic isotachophreogram even if they were manufactured by the same maker, and that the isotachopherogram of the lubricant changed in proportion to the running distance of an automobile. Each lubricant had its own changing rate. Moreover, A, B, C heavy oils, asphalt, soy sauce and sauce, which apparently resembled lubricants when they adhered to victims, were analysed with this method. They were found to be clearly different from lubricants in isotachopherogram and they could be discriminated from lubricants. Therefore, it was found that lubricants could be easily identified or discriminated from other lubricants such as engine oils, gear oils and other oils by comparing their isotachopherograms obtained with this method in a short time. It was, however, difficult to suggest the maker of a lubricant from isotachopherogram. We conclude from these observations that isotachophoresis method is useful for the analysis of lubricants in case of traffic accidents.

Accidents, Traffic↗

Evaluation of hexagonal boron nitride as a new tablet lubricant.

In this study, hexagonal boron nitride (HBN) was evaluated as a new lubricant for pharmaceutical tablet manufacturing. The other conventional lubricants such as magnesium stearate (MGST), stearic acid (STAC), and glyceryl behenate (COMP) were also tested along with HBN. Tablets were manufactured on an instrumented single-station tablet press to monitor and quantify the lower punch ejection force (LPEF). The force ratio, tablet crushing strength, disintegration time, and thickness were measured. The lubricant film formation and lubricant distribution in tablets were studied using the scanning electron microscopy (SEM) and electron probe micro analyzer (EPMA). Based on the force ratio, a good lubrication was obtained at 1% for MGST and HBN; in contrast, STAC and COMP did not show a good lubrication. After 1%, all lubricants performed well. MGST was found to be the most effective lubricant based on LPEF-lubricant concentration profile. HBN provided a 50% decrease in LPEF at 2% lubricant concentration and was rated as an effective tablet lubricant. HBN was better than either STAC or COMP. Unlike MGST, HBN had no significant prolongation effect on tablet disintegration times.

Boron Compounds↗

In situ lubricant degradation in Antarctic marine sediments. 1. Short-term changes.

A large-scale, in situ experiment was set up near the Bailey Peninsula area (Casey Station, East Antarctica) to monitor the natural attenuation of synthetic lubricants in marine sediments over five years. Here, we report the short-term changes after 5 and 56 weeks. The lubricants tested were an unused and used Mobil lubricant (0W/40; Exxon Mobil, Irving, TX, USA) and a biodegradable alternative (0W/20; Fuchs Lubricants, Harvey, IL, USA). Clean sediment was collected, contaminated with the lubricants, and deployed by divers onto the seabed in a randomized block design. The sampled sediments were analyzed by gas chromatography-flame-ionization detector and gas chromatography-mass spectrometry with selective ion monitoring. The base fluid of all lubricant treatments did not decrease significantly after 56 weeks in situ. Alkanoate esters of 1,1,1-tris(hydroxymethyl)propane in the biodegradable and unused lubricants were degraded extensively in situ; however, these esters constituted only a minor proportion of the lubricant volume. The additives, alkylated naphthalenes and substituted diphenylamines, were fairly resistant to degradation, which is of environmental concern because of their toxicity. The biodegradable lubricant did not break down to recognized biodegradable thresholds and, as such, should not be classified as biodegradable under Antarctic marine conditions. A separate experiment was conducted to determine the influence of sediment preparation and deployment on compound ratios within the lubricants, and we found that preparation and deployment of the contaminated sediments had only a minor effect on compound recovery. Further monitoring of this in situ experiment will provide much needed information about the long-term natural attenuation of lubricants.

Antarctic Regions↗

Reduction and avoidance of lubricant mist demands an integrated assessment approach.

A case study to identify major factors for lubricant mist exposure covered 15 metal machining sites. The investigation included milling, turning, drilling and grinding applications. Systematic analysis considered all relevant data concerning the machine tool, the lubricant and the suction plant. The efficiency of the implemented maintenance program at the installed filter systems was checked by concentration measurements immediately before and after service. All performed measurements of lubricant aerosol and vapor loads upstream and downstream of the installed filter systems were carried out according to VDI 2066 and BIA 3110, respectively. The selection criteria for the sites to be investigated, the systematic nature of the data acquisition and the procedure of the analysis are demonstrated in detail by performing comparisons between selected applications using emulsions and those employing straight oil for lubrication. The results of the study identify recirculation of ventilated air as the major source of workplace exposure to airborne lubricant emissions. More than 60% of the demisters investigated emit air at total lubricant loads (aerosols and vapor) above the limit of 20 mg m-3 at any time of operation; which also means immediately after service. A common reason for exceeded aerosol loads in recirculated air is e.g. the fact that the type of filter system applied is often not suitable for the separation problem. Loads of lubricant vapor are usually higher at the processes which use water emulsions as lubricant. In a quarter of the cases the limits were exceeded solely due to high vapor loads even immediately after service. The exposure can be reduced by replacing the lubricant, installation of a vapor separation plant or avoiding air recirculation. Maintenance time of the demisting system and aerosol separation efficiency of state-of-the-art demisting systems can be expanded by implementation of enhanced preliminary filter stages. This study confirms that appropriate service measures lower both aerosol emissions and lubricant vapor concentrations due to the reduction of exposed oil-wetted surfaces. The performed measurements show no significant relationship between loads of airborne lubricants and the type of machining process. Therefore, investigations at a much more detailed level have to be performed. However, the individual assessment of any workplace due to the complex situation remains essential.

Aerosols↗

Intraoral lubrication of PRP-1, statherin and mucin as studied by AFM.

The aim of this paper was to elucidate the mechanisms behind salivary lubrication with special emphasis on the lubricity of three key components of the pellicle, viz human acidic proline-rich protein 1 (PRP-1), human statherin and bovine submaxillary mucin (BSM). The lubricating properties of the proteins have been assessed by means of colloidal probe atomic force microscopy, and are discussed in relation to their adsorption behaviour. To various extents, the proteins investigated all showed a lubricating effect when adsorbed to silica surfaces. For comparable concentrations, PRP-1 was found to have a more pronounced lubricating effect than BSM, which in turn showed a higher lubricity than statherin. The relative lubricity is in accordance with previously reported relative adsorbed amounts of the three proteins, within the investigated concentration interval. It is concluded that PRP-1 has the highest lubricating capacity as a pure fraction among the preparations investigated, and that the lubricating effect of PRP-1 as a pure fraction is notably large as compared to the lubricity of human whole saliva.

Adsorption↗

Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.

The effect of geometry change of the bearing surfaces owing to wear on the elastohydrodynamic lubrication (EHL) of metal-on-metal (MOM) hip bearings has been investigated theoretically in the present study. A particular MOM Metasul bearing (Zimmer GmbH) was considered, and was tested in a hip simulator using diluted bovine serum. The geometry of the worn bearing surface was measured using a coordinate measuring machine (CMM) and was modelled theoretically on the assumption of spherical geometries determined from the maximum linear wear depth and the angle of the worn region. Both the CMM measurement and the theoretical calculation were directly incorporated into the elastohydrodynamic lubrication analysis. It was found that the geometry of the original machined bearing surfaces, particularly of the femoral head with its out-of-roundness, could lead to a large reduction in the predicted lubricant film thickness and an increase in pressure. However, these non-spherical deviations can be expected to be smoothed out quickly during the initial running-in period. For a given worn bearing surface, the predicted lubricant film thickness and pressure distribution, based on CMM measurement, were found to be in good overall agreement with those obtained with the theoretical model based on the maximum linear wear depth and the angle of the worn region. The gradual increase in linear wear during the running-in period resulted in an improvement in the conformity and consequently an increase in the predicted lubricant film thickness and a decrease in the pressure. For the Metasul bearing tested in an AMTI hip simulator, a maximum total linear wear depth of approximately 13 microm was measured after 1 million cycles and remained unchanged up to 5 million cycles. This resulted in a threefold increase in the predicted average lubricant film thickness. Consequently, it was possible for the Metasul bearing to achieve a fluid film lubrication regime during this period, and this was consistent with the minimal wear observed between 1 and 5 million cycles. However, under adverse in vivo conditions associated with start-up and stopping and depleted lubrication, wear of the bearing surfaces can still occur. An increase in the wear depth beyond a certain limit was shown to lead to the constriction of the lubricant film around the edge of the contact conjunction and consequently to a decrease in the lubricant film thickness. Continuous cycles of a running-in wear period followed by a steady state wear period may be inevitable in MOM hip implants. This highlights the importance of minimizing the wear in these devices during the initial running-in period, particularly from design and manufacturing points of view.

Biocompatible Materials↗

Microbial contamination of in-use lubricants for non-touch urethral catheters in intermittent self-catheterization.

There are no reports on microbial contamination of repeatedly used lubricant (84-87% glycerin containing 0.02% benzalkonium chloride) for non-touch urethral catheters in intermittent self-catheterization. In this work, we evaluated microbial contamination of in-use lubricant and its prevention. Between September and December, 1996, microbial contamination and water activity of in-use lubricants in sheathed and lubricated non-touch catheters connected to a tube used by 46 outpatients at our hospital was examined. Microbial contamination was detected at 5 to 2.6 x 10(8) colony-forming units (CFU)/ml in 14 (30.4%) of 46 samples. With higher water activity of the lubricant (a higher dilution rate of the lubricant with water), a higher concentration of microbial contamination was observed. In 3 (21.4%) of the 14 patients using contaminated lubricant, urine samples showed the same microbial species as those detected in the lubricant. To prevent microbial contamination of the lubricant, dilution of the lubricant with water, as a result of repeated use, should be avoided.

Bacteria↗

The effect of lubricants on viability of bacillus Calmette-Guerin for intravesical immunotherapy against bladder carcinoma.

PURPOSE: The viability of bacillus Calmette-Guerin (BCG) is crucial for induction of a local immune response and for effective therapy of recurrent superficial bladder carcinoma. During intravesical instillation of BCG lubricants are administered to assist catheterization, which contain bacteriostatic components that may interfere with the viability of mycobacteria. To verify this assumption, 5 commercially available lubricants were analyzed with regard to inhibition of viable BCG growth. MATERIALS AND METHODS: Five different lubricants and their components were co-incubated with Connaught strain BCG and the resultant growth of BCG was assessed. To prove the significant passage of lubricants into the bladder, fluid was recovered from the bladder after catheterization, analyzed with regard to the bacteriostatic effect and compared to normal urine of different acidity. RESULTS: Significant impairment of BCG viability, dependent on dosage and time of co-incubation, was noted with all lubricants analyzed. Several components, namely lidocaine hydrochloride, glyceryl stearate, propyl-4-hydroxy-benzoate and chlorhexidine digluconate, were identified as responsible for this inhibition. Fluid recovered from the bladder after lubricant assisted catheterization also showed an inhibitory effect, indicating significant mixture of the instillate with lubricants. CONCLUSIONS: Generous use of lubricants to assist catheterization during intravesical BCG therapy will result in a clinically significant decrease in the number of intravesically instilled viable mycobacteria. For this reason, during intravesical immunotherapy with BCG only small amounts of lubricants should be used for urethral catheterization, and use of catheters not requiring lubricants should be considered.

Adjuvants, Immunologic↗

Vaginal speculum lubrication and its effects on cervical cytology and microbiology.

The prevailing approach to Papanicolaou (Pap) and endocervical Gen-Probe(R) screening is to use an unlubricated vaginal speculum because of concerns that gel lubricant interferes with Pap smear adequacy and cervical microbiology. This study tests the hypothesis that lubrication of metal specula with a bacteriostatic gel does not increase unsatisfactory cervical cytology or decrease detection rates of endocervical Chlamydia trachomatis or Neisseria gonorrhoeae. At a publicly funded family planning clinic site, each of eight consecutive months was randomly designated by computer as an exclusively gel-lubricated or water-moistened specula use month. The assigned vaginal speculum intervention was used on all patients receiving a Pap smear and/or combination DNA probe assay for endocervical C. trachomatis and N. gonorrhoeae. From July 2003 through February 2004, 3460 Pap smears and 5535 combination probe assays for C. trachomatis and N. gonorrhoeae were collected from 6538 patients. During the 4 months of gel lubricant use, the rate of unsatisfactory cytology was 1.1% compared to 1.5% during the 4 months of water lubrication [odds ratio (OR) 0.74; 95% confidence interval (CI) 0.41-1.35]. During the 4 months of gel lubricant use, the detection rate for endocervical C. trachomatis was 1.5% compared to 1.5% (OR 1.05; 95% CI 0.67-1.62) in water lubricant months. The study population N. gonorrhoeae infection rate was too low to statistically analyze. The use of a small amount of gel lubricant on metal vaginal specula did not increase unsatisfactory cytology or decrease endocervical C. trachomatis detection rates when compared to water lubricant.

Adult↗

Analysis of potential lubricants for in vitro wear testing.

OBJECTIVES: A critical testing aspect for a reliable two-body wear simulation may be the lubricity condition. The main hypothesis tested in this study was that, over the experiment duration, the presence or absence of lubricants would provide to a composite similar wear rates to those observed under human saliva lubrication. METHODS: Seventy specimens, fabricated from a minifill composite, were tested in a programmable logic controlled wear simulator with human saliva (HS), mucin-based artificial saliva (MC), carboxymethylcellulose-containing saliva (CM), deionized water (DW) or with no lubrication (UN). Wear depth was quantified at the end of 1000, 5000, 10,000 and 50,000 cycles and at each 50,000 through 250,000 cycles. RESULTS: Over all the test period, UN led to the greatest wear. Initially, lubrication resulted in no significant differences among the wear rates. Subsequently, up to 50,000 cycles, depths of wear provided by HS and MC were still similar, being the lowest, whereas DW yielded greater wear than CM. Later, interposition of CM and HS resulted in equivalent wear. At 250,000 cycles, wear of the composite ranked as follows: MC<HS<CM<DW<UN. Regression analyses showed that for all lubricity conditions wear of the composite rose logarithmically with number of cycles. SIGNIFICANCE: The role of the interposed lubricant was of importance for the wear testing. The present findings supported by studies on the lubricity ability of mucin-based artificial saliva, allowed to conclude that this preparation may be considered as a potential lubricant for in vitro wear test purposes.

Adult↗

The effects of lubrication on the temperature rise and surface finish of glass-ionomer cements.

OBJECT: Previous work [Jones CS. Factors influencing the finishing of direct filling materials. PhD Thesis, University of London; 2002] has shown that there is an optimum load, speed and time that produced the smoothest surface when finishing glass-ionomer cement using each of four grades of a disc system. This study looks at the effects of lubrication on the temperature produced in samples of GIC when finished dry and with different lubricants using these optimal loads, speeds and times. It also compares the surface finish produced using different lubricants. MATERIALS AND METHODS: A thermocouple connected so that it permitted the display and recording of temperature against time was inserted 1mm into the base of samples of a glass-ionomer cement. The samples were finished and polished using each of the grades of a disc system in a specially constructed jig that mimicked oral finishing. After roughening, the pre-determined optimum loads, speeds and times were used sequentially for each of the four grades of disc. Five samples were tested for each method of finishing. Firstly run dry, then in turn lubricated with water, walnut oil and petroleum jelly. After the use of each abrasive disc the surface roughness was measured using a profilometer. One of the five samples was selected at random and prepared for examination in the scanning electron microscope. All results were subjected to non-parametric statistically analyses. RESULTS: Walnut oil and petroleum jelly produced significant temperature increases compared to both dry and with water finishing. Lubricated with water significantly reduced the temperature rise compared to dry. The Ra values of 0.5 microm was obtained for the coarse and a value of 0.3 microm for the medium discs run without lubrication. With lubrication the Ra increased although there was little difference between the lubricants. However the photomicrographs showed that walnut oil and petroleum jelly caused gross morphological changes indicating major surface destruction. CONCLUSIONS: The practice of finishing GICs using petroleum jelly or similar lubricant appears to be detrimental. Further experimental work needs to be done to advise practitioners on finishing GICs to produce the smoothest surface possible.

Dental Polishing↗

Prediction of lubricating film thickness in UHMWPE hip joint replacements.

An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.

Biocompatible Materials↗

The effect of vaginal speculum lubrication on the rate of unsatisfactory cervical cytology diagnosis.

OBJECTIVE: Nonlubricated plastic specula can adhere to the vaginal introitus and cause discomfort with pelvic examination. We wanted to see if application of water-soluble gel lubricant to the plastic vaginal speculum would change the unsatisfactory cervical cytology diagnosis rate. METHODS: Five public health family planning clinic sites were randomized to either water-soluble gel or water only as lubricant during speculum examination for cervical cytology collection. The pathologists were unaware of the assignment of lubricant use. The cumulative rates of cervical cytology diagnoses were calculated for 6 months before, 6 months during, and 6 months after the intervention. RESULTS: From July 1998 through December 1999, 8534 Papanicolaou smears were collected, with 1440 using gel lubrication from January 1999 through June 1999. Rates of unsatisfactory smears for lubricant use clinics were 1.4% during use of lubricant and 1.4% without use (odds ratio [OR] 1.0; 95% confidence interval [CI] 0.6, 1.8). Rates of unsatisfactory smears for lubricant use versus nonlubricant use clinics during the gel intervention period were 1.4% versus 1.3% (OR 1.1; 95% CI 0.6, 2.0). There were no significant differences for the rates of atypical squamous cells of undetermined significance, low-grade squamous intraepithelial lesion, high-grade squamous intraepithelial lesion, or atypical glandular cells of undetermined significance within or between lubricant and nonlubricant clinics for each 6-month period. There were no cases of invasive cancer. CONCLUSION: The use of a small amount of water-soluble gel lubricant on the outer inferior blade of the plastic vaginal speculum does not change cervical cytology results in a young, reproductive-age population.

Female↗

Hydrostatic pressurization and depletion of trapped lubricant pool during creep contact of a rippled indenter against a biphasic articular cartilage layer.

This study presents an analysis of the contact of a rippled rigid impermeable indenter against a cartilage layer, which represents a first simulation of the contact of rough cartilage surfaces with lubricant entrapment. Cartilage was modeled with the biphasic theory for hydrated soft tissues, to account for fluid flow into or out of the lubricant pool. The findings of this study demonstrate that under contact creep, the trapped lubricant pool gets depleted within a time period on the order of seconds or minutes as a result of lubricant flow into the articular cartilage. Prior to depletion, hydrostatic fluid load support across the contact interface may be enhanced by the presence of the trapped lubricant pool, depending on the initial geometry of the lubricant pool. According to friction models based on the biphasic nature of the tissue, this enhancement in fluid load support produces a smaller minimum friction coefficient than would otherwise be predicted without a lubricant pool. The results of this study support the hypothesis that trapped lubricant decreases the initial friction coefficient following load application, independently of squeeze-film lubrication effects.

Animals↗