PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Lasers, Excimer”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

[The Excimer laser. II. Initial experiences with the Excimer laser in Lucerne].

In the period between September 1990 and July 1991, 35 patients (46 eyes) were treated with the Excimer Laser. In 25 patients (34 eyes), a Myopia-Laser-Shaping was performed, one patient was treated for both myopia and astigmatism. In eight patients (10 eyes) correction of astigmatism was carried out. Two patients with recurrent erosions and one patient with superficial scarring of the cornea were treated. The authors review their initial experience with the Excimer Laser. The decision to initiate treatment must not be undertaken lightly, because the possibility of serious complications may not be neglected. This method shows promise in selected patients with light to medium degrees of myopia. In cases of severe myopia, our experience is encouraging. Subjectively, the patients are satisfied with the results, which do not fall short of their expectations. Further research and clinical experience in this area is urgently required.

Astigmatism↗

Corneal wound healing after excimer laser keratectomy.

Excimer laser keratectomy is widely used to correct refractive errors. Several complications of excimer laser keratectomy are reported including corneal infection, regression, corneal haze formation, glare and halo. Most of the complications are closely related to the corneal stromal wound healing process. In order to perform the excimer laser keratectomy with minimum complications, we should understand the mechanism of the corneal stroma wound healing process. In addition, such knowledge will help us to regulate the corneal stromal wound healing process in the future. In the present article, we discuss the molecular mechanism of the corneal stromal wound healing process after excimer laser keratectomy and its regulation by anti-inflammatory agents.

Corneal Stroma↗

The changing profile of patient selection, procedural techniques, and outcomes in excimer laser coronary angioplasty. Participating Investigators of the Percutaneous Excimer Laser Coronary Angioplasty Registry.

During the course of development of excimer laser angioplasty, several changes in patient selection and technique have occurred. It is uncertain, however, whether these changes have been associated with improved procedural outcome. In this study, multivariable regression methods were used to identify the factors responsible for clinical success, major complications, and vessel perforation in 2,041 consecutive patients treated with excimer laser coronary angioplasty. The overall rates of clinical success were 89%, major complications 7.5%, and vessel perforation 2.1%. Clinical success was 86% in patients treated with prototype catheters, 89% with flexible catheters, 92% with extremely flexible catheters, and 95% in patients treated with directional eccentric catheters (P < 0.001). By multivariable analysis, clinical success increased with each subsequent catheter design (odds ratio [OR] = 1.4 per iteration [95% confidence interval 1.2, 1.6]), and with improved lesion selection. Major complications were reduced when operators had performed more than 25 cases (rate = 6.5%, OR = 0.7 [0.5, 0.9]), and the incidence of vessel perforation was decreased when the size of the target vessel was > 1.0 mm larger than the diameter of the laser catheter (rate = 1.1%, OR = 0.3 [0.2, 0.5]). In conclusion, during the course of clinical investigation with excimer laser angioplasty, procedural outcome has improved. These results emphasize the importance of careful patient selection and procedural technique to enhance the success of excimer laser angioplasty.

Aged↗

Astigmatic change 1 year after excimer laser treatment of myopia and myopic astigmatism. Melbourne Excimer Laser Group.

PURPOSE: To evaluate the surgically induced astigmatism (SIA) 1 year after excimer laser photorefractive astigmatic keratectomy (PARK) and photorefractive keratectomy (PRK). SETTING: Royal Victorian Ear and Eye Hospital, Melbourne, Australia. METHODS: This study comprised 333 PARK patients and 155 PRK patients treated with a VISX 20/20 excimer laser and followed prospectively for 12 months. Vector analysis of the change in astigmatism was used to calculate the SIA in the PRK group and the percentage of astigmatism corrected in the PARK group. RESULTS: Among patients with low cylinders astigmatic correction varied greatly, particularly in those treated for large amounts of myopia. The spherical PRK treatments yielded a mean induced postoperative astigmatism of 0.47 diopter. There was a linear relationship between this inadvertent SIA and increasing myopia. CONCLUSION: Excimer laser surgery for myopia creates a low degree of random, unpredictable SIA that may be the result of irregular epithelial thickening during postoperative healing. This creates a background noise of astigmatic change upon which the targeted astigmatic correction is superimposed.

Adult↗

[Eight year results of excimer laser correction for irregular astigmatism by linear excimer laser photoablations of the cornea in cases of keratoconus].

PURPOSE: The purpose of this study was to evaluate changes of the corneal curvature as a result of linear incisions with excimer laser and also to evaluate durability of the achieved effect, including the changes in visual acuity, topographic maps of the corneal curvature and keratometric changes at the location of keratoconus 2, 4, 8, 16, 24 weeks postoperatively. MATERIAL AND METHODS: At the First Department and Clinic of Ophthalmology, Silesian Medical School in Katowice, 294 patients went through ophthalmological examinations. 164 patients (187 eyes) with the III degree of keratoconus according to the Amsler scale, including 69 women (77 eyes) and 95 men (110 eyes), were classified for the excimer laser surgery with the method of linear, corneal incisions with MEL-60 (Aesculap-Meditec). The eyes did not tolerate contact lenses at all or because of peripheral location of the keratoconus. The patients were from 16 to 60 years of age (the mean age was 27.9 years). RESULTS: According to the statistical results, there were no difference between the effects of treatment between men and women. Correlation between the results of the surgery and the patients age showed that the latter did not have any effect on the final result. Lack of correlation between the height of the absolute corneal curvature at the keratoconus and the achieved change after the surgery was reported, thus changes of the corneal curvature parameters do not depend on its parameters before the surgical procedure. Absolute visual acuity of patients was improving and reached maximally 0.252 of the unit. As a result of the single surgery, the maximum change of keratometric values was 4.949 D, and the minimum was 3.611 D. In the case of the secondary surgery, the maximum keratometric value at the axis of the incision was 8.55 D and the minimum one was 7.101 D. CONCLUSION: To sum up, we can say that the favourable effect of decreasing the irregular corneal astigmatism with the method of linear laser fotoablations was maintained throughout the whole observation period, which allowed to shift in time planned corneal transplantation.

Adolescent↗

Excimer laser treatment for high and extreme myopia. The Melbourne Excimer Laser and Research Group.

OBJECTIVE: The excimer laser allows the controlled ablation of corneal tissue to correct refractive error. We assessed the efficacy of excimer laser treatment for persons with high (spherical equivalent between -5 and -10 diopters) and extreme (spherical equivalent greater than -10D) myopia. METHODS: Patients were assessed 1, 3, and 6 months postoperatively. A VisX Twenty/Twenty laser was used. Visual acuity, refraction, corneal clarity, and adverse reactions were evaluated at each visit. RESULTS: Six month follow-up data were available for 194 high myopes and 53 extreme myopes. Postoperative healing was similar for the two groups. Six months postoperatively, 89.2% of high myopes and 49% of extreme myopes were within 2D of planned refraction. At 6 months, 28% of high myopes had an uncorrected visual acuity of 20/20 and 71% had an uncorrected visual acuity of 20/40. Of extreme myopes, 4% had an uncorrected visual acuity of 20/20 and 30% had an uncorrected visual acuity of 20/40. Significantly more corneal haze was observed in the extreme myopes. Loss of 2 or more lines of best corrected visual acuity was observed in 13% of high myopes and 13% of extreme myopes at 6 months. CONCLUSIONS: Excimer laser photorefractive keratectomy is an alternative means of treating high and extreme myopia and can cause a significant reduction in myopia. There is a need to gather further information as more patients are followed up for greater time.

Adult↗

Overcorrection after excimer laser treatment of myopia and myopic astigmatism. Melbourne Excimer Laser Group.

OBJECTIVE: To study the incidence and associations of overcorrection after excimer laser treatment of myopia and myopic astigmatism. METHODS: The study cohort consisted of 645 patients who had photorefractive or photoastigmatic refractive keratectomy done by an excimer laser during a 2-year period. Patients were assessed 1,3,6, and 12 months postoperatively. The variables evaluated were visual acuity, refraction, keratometry, and corneal clarity. RESULTS: At 1 month, overcorrection of more than +1 diopter spherical equivalent (SEQ) was seen in 22% of the eyes. This progressively regressed so that only 8.6% of the 140 eyes that were overcorrected at 1 month were overcorrected at 1 year. Overall, 2.2% of eyes were overcorrected at 1 year. The magnitude of attempted correction and use of topical nonsteroidal anti-inflammatory drugs disclosed a notable association with occurrence of overcorrection at 1, 3, and 6 months. The use of bandage contact lenses also was associated with overcorrection at 1 and 3 months. After controlling for myopia and use of contact lenses, the odds of overcorrection for use of topical nonsteroidal anti-inflammatory drugs at 1,3, and 6 months were 2.21 (95% confidence limits [CL]=1.49, 3.44), 1.69 (95% CL=0.88, 3.24), and 2.01 (95% CL=0.88, 4.56), respectively. The odds of overcorrection with bandage contact lenses were 1.79 (95% CL=1.05, 3.05) at 1 month and 2.42 (95% CL=1.23, 4.75) at the end of 3 months. No associations were seen between overcorrection and age, gender, surgical technique, or simultaneous astigmatic corrections. CONCLUSIONS: Overcorrection is common during the early postlaser treatment period and is associated with degree of myopia, use of nonsteroidal anti-inflammatory drugs, and bandage contact lens wear.

Adult↗

Treatment of alopecia areata with the 308-nm xenon chloride excimer laser: case report of two successful treatments with the excimer laser.

BACKGROUND AND OBJECTIVES: Alopecia areata is a common disease of unknown etiology; it causes significant cosmetic and psycho-social distress for most of the people it affects. We report on an innovative form of treatment in two patients with typical alopecia areata on the capillitium. STUDY DESIGN/PATIENTS AND METHODS: We successfully treated two patients whose alopecia areata had worsened progressively for 3 and 14 weeks. The treatment involved the use of a 308 nm xenon chloride excimer laser (dosage 300-2,300 mJ/cm(2) per session). RESULTS: After 11 and 12 sessions within a 9-week and 11-week period, the entire affected focus showed homogenous and thick regrowth. No relapse was observed during the follow-up period of 5 and 18 months. CONCLUSIONS: The use of the excimer laser is an effective, elegant, and safe means of treatment and has good tolerability. Analogous to topical treatment of alopecia areata, the immunosuppressive mechanism of the excimer laser can be interpreted as an induction of T-cell apoptosis. This new means of treatment has yet to be discussed in medical literature. Further studies with greater numbers are needed to assess its potential more precisely and evaluate the excimer laser in treating alopecia areata.

Adult↗

Excimer laser correction of astigmatism with multipass/multizone treatment. The Melbourne Excimer Laser Group.

PURPOSE: To evaluate the accuracy of excimer laser correction of myopic astigmatism by multipass/multizone photoastigmatic refractive keratectomy (PARK). SETTING: Tertiary referral ophthalmic hospital with an associated private laser facility. METHODS: This study comprised a consecutive series of 332 eyes of 289 patients who were followed for 6 months. All patients were 18 years or older, had stable myopic astigmatism (up to a -19.0 diopters [D] spherical equivalent [SE] at the spectacle plane), and had a best corrected visual acuity of at least 20/60 in both eyes. All eyes were treated with a VISX Twenty-Twenty excimer laser. The correction was divided between ablation zones using a multipass/multizone treatment paradigm based on the amount of myopia and astigmatism. Patients were examined 1 week, and 1, 3, and 6 months after surgery. RESULTS: Analysis of the mean percentage of spherical correction across the range of myopic preoperative SEs treated demonstrated 90% correction for most amounts of myopic astigmatism. Eyes with low myopia (mean preoperative SE < or = -5.0 D) treated with < or = -1.0 diopter cylinder (DC) of astigmatism achieved a mean percentage of spherical correction of 91% versus 93% in eyes with high myopia (> -5.0 D mean preoperative SE). Eyes with low myopia treated with > -1.0 DC of astigmatism achieved a mean percentage spherical correction of 90% versus 89% in eyes with high myopia. The differences between the two groups were not statistically significant. Patients with high relative cylinder (> 80% of total sphere treated) achieved comparable results. Analysis of the astigmatic component of the treatment, independent of the spherical result, showed a trend toward overcorrection in the high myopia group with less than -1.0 DC and a mean astigmatic correction of 89 and 98%, respectively, in the low and high myopic astigmatism groups. The mean angle of error was +2.0 degrees. CONCLUSION: Multipass/multizone PARK for myopic astigmatism demonstrated a high degree of predictability and stability with desirable results for low and high levels of astigmatism across the range of myopic astigmatism treated by surface ablation.

Adult↗

Cytotoxicity and mutagenicity of excimer laser radiation.

Excimer laser radiation at 193 nm, 248 nm and 308 nm cause DNA photochemistry. The photobiological effects resulting from exposure of cells to 308 nm and 248 nm radiation appear to be the same as those obtained using low irradiance CW sources at similar wavelengths. This indicates that the high irradiances available from the excimer laser cause the same DNA photochemistry as the lower-irradiance CW sources. Excimer laser radiation at 193 nm causes less cytotoxicity than predicted based on the DNA absorption spectrum. This may result from absorption of 193 nm radiation by protein present between the cell surface, and nuclear DNA, or from less efficient DNA photochemistry using 193 nm radiation. In vitro assays indicate that DNA-damaging effects resulting in cytotoxicity decrease in the order 248 nm greater than 308 nm greater than 193 nm.

Animals↗

Ultrasound biomicroscopic assessment of the cornea following excimer laser photokeratectomy.

Excimer laser photokeratectomy is used as a refractive tool and in the treatment of superficial corneal disease. Ultrasound biomicroscopy is a new method of ultrasound imaging developed in our laboratories that allows subsurface imaging of ocular structures at microscopic resolution. We used this imaging method to examine 12 patients following excimer laser keratoablation. Following treatment, the normal appearance of a highly reflective Bowman's membrane below the epithelial echo was absent in the treatment zone. Corneal thinning was also noted. Postoperative scarring in the treatment area could be imaged as highly reflective regions in the superficial stroma. In therapeutic cases, corneal opacities could be imaged pretreatment and their depth assessed. The degree of opacity removal could be analyzed post-treatment. Ultrasound biomicroscopy helped assess corneal changes secondary to excimer laser photokeratectomy.

Cornea↗

[Measuring corneal thickness in photo-keratectomy with a reflectometry incorporated into the laser beam of the excimer laser].

PURPOSE: To integrate a newly developed OLCR instrument into the optical system of the excimer laser. The instrument is designed to perform corneal pachymetry before, during, and after corneal photoablation and thus allow for a precise and continuous on-line measurement of the corneal photoablation process. METHODS: The conditions required to integrate the OLCR instrument into the excimer laser optics were investigated. With a technical setting providing on-line data of corneal thickness, three groups of 8-10 corneae received central keratectomies of 27 (group 1), 82 (group 2) and 163 (group 3) microns calculated central depth and 7.38 mm diameter. All measurements were performed with OLCR and ultrasound. RESULTS: The OLCR instrument was coupled into the optical system of the excimer laser and a useful signal obtained at SLD power levels of 40 microW incident on the cornea. Individual corneal thickness measurements were obtained before, during and after the photoablation procedure. In group 1, the ablation was 50.3 (40-68) microns measured with ultrasound and 30.2 (27-38) microns measured with OLCR. In group 2, the ablation was 101.1 (80-113) microns measured with ultrasound and 93.3 (76-109) microns measured with OLCR. In group 3, the ablation was 210.6 (190-227) microns measured with ultrasound and 188.4 (181-197) microns measured with OLCR. The precision (standard deviation) for measurements of individual corneas was 1-2 microns with OLCR and up to 12 mm in Ultrasound measurements. CONCLUSION: With this interferometric method, continuous, non-contact measurement of corneal thickness before, during and after excimer laser photoablation were performed. By establishing a feed-back control between the pachymetric measurements and the photoablation process, the precision of excimer ablation may possibly be further increased.

Animals↗

[Our experience in using laser excimer].

In this paper we present our experience concerning 658 excimer laser operations: statistical data about the number of operations, preoperative investigations, postoperative care and postoperative complications.

Astigmatism↗

One-year evaluation of excimer laser photorefractive keratectomy for myopia and myopic astigmatism. Melbourne Excimer Laser Group.

OBJECTIVE: To evaluate prospectively the efficacy and safety of excimer laser photorefractive keratectomy in the treatment of myopia and myopic astigmatism. METHODS: Up to 15 diopters (D) of myopia with or without astigmatism of less than 6 D was treated with an excimer laser (VISX Twenty/Twenty). One hundred fifty procedures have been followed up for more than 12 months. RESULTS: Postoperative refractions were generally stable after 3 months without significant early overcorrection. Of those eyes treated with spherical equivalents of 5 D or less, 96% were within 1 D of the targeted refraction after photorefractive keratectomy and 88% had uncorrected visual acuities of 20/40 or better. At 12 months, 77% of all 150 eyes treated achieved an uncorrected visual acuity of 20/40 or better and 81% were within 1 D of the intended correction. Nine eyes (6%) lost 2 or more lines of best corrected visual acuity and 14 (9%) gained 2 or more lines. Adverse reactions were reported in 12 patients (8%) during the postoperative period. CONCLUSIONS: Photorefractive keratectomy is capable of correcting low and moderate myopic errors with a relatively high degree of accuracy and safety. The predictability and stability of the postoperative refraction during the first 12 months seem to be good.

Adult↗

Clinical results of coronary excimer laser angioplasty: report from the European Coronary Excimer Laser Angioplasty Registry.

From January 1991 to January 1993 the clinical and angiographic data of 470 patients were included in the European Coronary Excimer Laser Angioplasty Registry. Symptoms were CCS class 3 in 23% and CCS class 4 in 14.7%; unstable angina was present in 14.7% and 6.6% of patients had acute myocardial infarction. Of 477 treated lesions, 60% were type B2, and 19% type C. The lesion was located in the LAD in 61%, in the LCX in 16%, in the RCA in 20%, in a protected left main stem in 1.3% and in a saphenous vein graft in 2.5%, respectively. Failure of laser angioplasty occurred in 56 (12%) interventions. By multivariate analysis failure was associated with the intention to treat long segmental lesions (risk ratio (RR) 3.6, confidence interval (CI) 2.9 to 4.4; P = 0.0005), segments with severe prestenotic tortuosity (RR 3.5, CI 2.4 to 4.6; P = 0.02) and total occlusions (RR 2.1; CI 1.4 to 2.8; P = 0.05). Complications included vasospasm (13.4%), dissection (14.7%), flow limiting dissection (4%), reclosure (7.8%), and perforation (1.9%). Myocardial infarction occurred in 2.1%, CABG was requested in 1.9%, and the mortality was 1.5%. Procedural success was achieved in 89%. Individual morphological criteria for a reduced procedural success were the presence of a thrombus (RR 6.4; CI 5.0 to 7.7; P = 0.007) and vessel calcification (RR 2.6; CI 1.9 to 3.2; P = 0.005). Procedural success was slightly lower in type C lesions (86%) than in type B2 (88%) type B1 (95%), and type A lesions (92%), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

[An experimental study of excimer laser angioplasty].

An excimer laser, which is a pulsed ultraviolet laser and ablates tissue precisely with no thermal injury, is expected to coronary laser angioplasty. We transmitted XeCl excimer laser (308 nm) via a 400 microns fused silica fiber. In the first experiment, we studied about excimer laser ablative effects to normal canine arteries and atherosclerotic rabbit aortas, and about healing responses following excimer laser irradiation in both models. Surfaces after excimer laser ablation were slightly rough but no thermal injury was found in the media. And for healing process of normal canine arteries, endothelial cells appeared at 3 weeks and completely covered surfaces with fibrointimal ingrowth at 3 months. In the rabbit aortas, at 3 weeks there was reconstruction of the surface. At 2 months no accelerated atherosclerotic or aneurysmal changes were observed. In the second, with this excimer laser (short pulse) and 400 microns fused silica fibers (distal fiber-end power: 3-6 mJ/pulse), we performed transluminal laser angioplasty to recanalize totally occluded canine femoral arteries under an angioscopic guidance. We cold recanalize 8 of 9 totally occluded arteries with no thermal injury of adjacent tissue, though perforations were observed in 7 of 9 arteries. In the third, we used a newly-developed long pulse excimer laser, with which distal fiber-end energy was about 3 to 4 times as much as the short pulse one, to recanalize totally occluded canine arteries. In result, recanalization was performed in 6 of 8 arteries rapidly with little thermal injury. However, we observed perforations in 6 of 8 arteries like the short pulse one. Multifiber catheter ("over the wire system") coupled with this long-pulse excimer laser was used to reconstruct stenotic iliac arteries of atherosclerotic rabbit models. The procedure was successful in all the 5 rabbits. In conclusion, our preliminary results suggested that further developments of a more powerful and longer pulse-duration excimer laser, optic delivery system and guidance system would make excimer laser angioplasty safer and more effective method in the near future.

Angioplasty, Laser↗

[Holmium:YAG infrared laser and UV-Excimer. Laser effects on oral mucosa].

The in-vivo tissue ablation characteristics of a pulsed infrared laser (Holmium:YAG, lambda = 1980) and a pulsed excimer laser (XeCl, lambda = 308 nm) were studied. The holmium laser energy was coupled into nylon fibres. The excimer laser energy was coupled into quartz fibers. Laser incisions were made on white rats at different sites of the tongue. Power settings of 400 mJ per 2.5 microseconds pulse at 5 pulses per second for the holmium:YAG laser and 250 mJ per 1 microsecond pulse at 20 pulses per second for the excimer laser were used. Thermal gradients following laser application were measured. Excellent control of depth of tissue ablation was noted for both types of lasers. The tissue response was examined by light microscopy. Histological studies revealed tissue defects with clean contours. The coagulative necrosis zone for the 400 mJ holmium:YAG injuries measured from 370 microns to 640 microns, compared with 40 microns to 160 microns with the 250 mJ UV-excimer injuries. Wound healing was studied over a six-week period. Histologically, wound closure was completed after four weeks showing re-epithelialization without scar formation for both types of laser. The in-vivo tissue ablation characteristics and the operation reliability of the two lasers were compared.

Animals↗