PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Leukocyte Reduction Procedures”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Collection by a simple bag method and the function of granulocytes in granulocyte transfusion.

Granulocyte transfusion is effective for treating some intractable infections. We have recently developed a simple bag method for collecting granulocytes without using apheresis. A recombinant human granulocyte colony-stimulating factor (G-CSF) (50, 100, 200, and 400 microg nartograstim) was administered to 5 healthy male adult volunteers. The quantity and quality of the collected granulocytes were evaluated. The G-CSF dose proportionally increased the collected neutrophil count. The count of collected neutrophils correlated strongly with the count before collection (r2 = 0.684; P < .001). The neutrophil counts collected from 200 mL whole blood were 0.90 x 10(9), 1.68 x 10(9), 2.40 x 10(9), and 2.99 x 10(9) at 50, 100, 200, and 400 microg G-CSF, respectively. There was no significant difference in neutrophil counts between the 200-microg and 400-microg doses. doses. Concerning granulocyte functions, active oxygen production and phagocytic capacity were not affected by irradiation with 15 Gy. Transient arthralgia occurred in 2 subjects. A single administration of 200 microg G-CSF enabled the collection of large quantities of granulocytes by the bag method. We consider that the collection of granulocytes by the bag method from 400 mL of whole blood drawn twice can theoretically provide 3 x 10(8)/kg of granulocytes for treating children weighing less than 30 kg.

Adult↗

[Effects of leukocyte depletion filter on canine kidney during cardiopulmonary bypass].

OBJECTIVE: To explore the effect of a reforming leukocyte depletion filter (LDF-1) on the functional and pathologic changes of canine kidney during cardiopulmonary bypass (CPB). METHODS: Twelve Mongolian dogs were randomly allocated into a control group (no LDF-1, n = 6) or a leukocyte-depleted filter group (LDF-1 placed in venous line, n = 6). CPB of the dogs anestheitized with sodium pentobarbitone at 25 mg/kg was set up. After 10 min of CPB, aorta was clamped and St. Thomas cardioplegic solution at 20 mg/kg was immediately injected into the root of aorta. The aortic cross-clamp was released and CPB was closed at 70 min. Dogs were observed for 2 h after weaning from CPB. LDF-1 was opened at 2 min and stoped at 7 min during initially running CPB in the LDF-1 group. Circulating leukocytes, plasma L-selectin, and plasma IL-8 were respectively counted before CPB, at 10 minutes, 40 min, and 75 min during CPB, the end of CPB, and 2 h after CPB. The urine analysis and renal pathology, which were obtained before CPB and 2 h after CPB, were observed. RESULTS: The number of leukocytes significantly decreased by 55% - 68% in the LDF-1 group compared with the baseline during CPB. The value at 10 min of CPB in the LDF-1 group was lower than that in the control group (P < 0.05). Plasma levels of L-selectin and IL-8 obviously increased in the 2 groups compared with the baseline during CPB, but both levels at 2 h after CPB in the LDF-1 group were lower than those in the control group (P <0. 05). No statistic difference was found in plasma levels of urea and creatinine, but hematuria was observed in the 2 groups at 2 hours after CPB. The pathologic changes of kidney, which was mainly renal tubule swelling accompanied partly with vacuolar degeneration, were similar under the light microscope in the 2 groups at 2 h after CPB. Obvious glomerular damage was not found. CONCLUSION: LDF-1 can effectively decrease leukocyte counts and the inflammatory reaction, but it can not bring about excellent protective effect on kidney during CPB when used alone. Attention to should be paid the renal protection in the postoperative CPB.

Acute Kidney Injury↗

Surgical site infection following bowel surgery: a retrospective analysis of 1446 patients.

HYPOTHESIS: We sought to determine whether the administration of preoperative antibiotics, intraoperative transfusion of blood products, and intraoperative hypothermia has any impact on the incidence of postoperative surgical site infections (SSIs) in a heterogeneous patient population undergoing bowel surgery. DESIGN: Retrospective analysis. SETTING: From September through December 2002, data on 1472 patients undergoing bowel surgery at 31 academic medical centers in the United States were collected. PATIENTS: Patients were included in the analysis if they were older than 17 years of age and underwent any surgery involving the small bowel, colon, or rectum. Main Outcome Measure Postoperative SSI. Variables that might affect the risk for developing SSIs were analyzed using multivariate logistic regression analysis. RESULTS: Perioperative transfusion (P = .04; odds ratio, 1.64), and the presence of any infection at the time of surgery (P = .05; odds ratio, 2.46) were independent risk factors for SSI. Patients with a lower intraoperative temperature nadir had a lower risk for SSI (P = .05; odds ratio, 1.33), although this difference is not clinically significant (35.8 degrees C +/- 0.8 degrees C vs 36.0 degrees C +/- 0.9 degrees C, P<.05). There was a trend toward statistical significance for wound class when added to the multivariate model (P = .09; odds ratio, 1.41). The administration of antibiotics within 120 minutes prior to incision or within 120 minutes prior to and 120 minutes after incision had no effect on SSIs in this patient population. CONCLUSIONS: This study validates perioperative transfusion as an independent risk factor for SSI. The lack of effectiveness of perioperative antibiotic prophylaxis is surprising because it is discordant with the previous literature, and this finding needs further evaluation.

Adolescent↗

Clinical effectiveness of leukocyte filtration during cardiopulmonary bypass in patients with chronic obstructive pulmonary disease.

BACKGROUND: We tested the hypothesis that leukocyte filtration during pulmonary reperfusion preserves pulmonary function and results in improved oxygenation after cardiopulmonary bypass (CPB) in patients with chronic obstructive pulmonary disease (COPD). METHODS: In a prospective, randomized study, the treatment group consisted of 20 patients with COPD from consecutive open-heart procedures. A primed leukocyte filter was connected to the arterial line downstream of the standard arterial filter but was excluded from circulation. Circulated blood was directed through the leukocyte filter approximately 10 minutes before aortic cross-clamp removal and at early reperfusion for up to 30 minutes. These patients were compared to 20 additional COPD patients (controls) on whom systemic leukocyte filtration was not used during open-heart surgery. RESULTS: There was no significant difference in gender, age, left ventricular ejection fraction, type of procedure, aortic cross-clamp time, perfusion time, preoperative FEV1 and preoperative respiratory index (Pao2/FiO2 ratio) between treatment and control groups. The respiratory index changed in the treatment group by +9.8% of baseline after completion of CPB, by -14.2% upon arrival in the intensive care unit (ICU), and by -19.6% 12 hours later, whereas in the control group, it changed by -14.5% (p < 0.05), -27.7%, and -24%, respectively. Leukocyte-depleted patients required shorter intubation time (20.4 +/- 16.1 hours), ICU stay (46.2 +/- 40.1 hours) and length of hospitalization (8.3 +/- 2.8 days) than controls (29.5 +/- 21.9 hours, p < 0.05; 75.5 +/- 34.9 hours, p < 0.005; and 10.4 +/- 3.5 days, p < 0.05, respectively). Surgical (30-day) mortality was zero in both groups. CONCLUSIONS: In COPD patients having CPB, systemic leukocyte depletion at early reperfusion was associated with better oxygenation, shorter intubation time, and shorter ICU and hospital stays. Leukocyte filtration during CPB most likely preserves pulmonary function by ameliorating pulmonary reperfusion injury.

Aged↗

Optimizing platelet transfusion therapy.

Platelet transfusions are widely used. Prophylactic transfusions are employed in severely thrombocytopenic patients without evidence of bleeding, but no randomized trial data prove the safety or efficacy of this approach. Randomized trials have demonstrated the equivalence of transfusion triggers of 10,000 and 20,000/microl for prophylactic transfusions. The former threshold is potentially safer for the patient, conservative of donor resources and leads to lower costs, with perhaps a slightly greater risk of minor hemorrhage. Randomized trials have demonstrated the equivalence of pheresis or whole blood-derived platelet transfusions. The former present a lower risk for infectious agents, and the latter are less expensive and a more efficient use of limited donor resources. Randomized trials prove that leukoreduced and ABO identical platelet transfusions reduce the risks of HLA alloimmunization and platelet transfusion refractoriness (both leukoreduction and ABO matching), transfusion reactions (leukoreduction) and CMV transmission (leukoreduction). Leukoreduction and ABO matching of platelet transfusions also have been associated in preliminary observational studies with reduced morbidity and mortality in surgical patients and reduced infections in patients with leukemia. These results require further investigation. Future challenges include (1) determining the best approach to bacterial contamination of platelets, whether by detection methods or pathogen inactivation and (2) determining the threshold for prophylactic platelet transfusions in thrombocytopenic patients undergoing surgery or invasive procedures.

ABO Blood-Group System↗

Separation of whole blood into plasma and red cells by using a hollow-fibre filtration system.

BACKGROUND AND OBJECTIVES: The aim of this study was to assess the separation of whole blood into red cells and plasma by using the Sangofer device, which is a gravity-fed, hollow-fibre system. The components would then be compared with those produced by the use of more elaborate technical equipment. MATERIALS AND METHODS: Ten whole-blood units were leucoreduced by using a WBF2 filter and immediately separated into red cells and plasma by using the Sangofer blood-separation device. Red cells were stored in additive solution and tested on days 1 and 42. The plasma was assayed for levels of various coagulation factors and for markers of both coagulation and complement activation. RESULTS: The red-cell parameters were similar to those obtained when routine centrifugation methods were used. The filter did not cause haemolysis. Levels of plasma factor VIII and factor XI were lower than those seen in routinely produced leucoreduced plasma units but there was no evidence of activation of the coagulation and complement systems. CONCLUSIONS: The Sangofer device is simple and straightforward to use and eliminates the need for both centrifugation and automated separation steps during the processing of whole blood into red cells and plasma components. Minor changes are required to make the procedure easier to incorporate into routine use.

2,3-Diphosphoglycerate↗

Gene expression analysis in platelets from a single donor: evaluation of a PCR-based amplification technique.

BACKGROUND: Genetic analysis of platelet mRNA may facilitate the diagnosis of disorders affecting the megakaryocytic-platelet lineage. Its use, however, is limited by the exceptionally small yield of platelet mRNA and the risk of leukocyte contamination during platelet preparation. METHODS: We depleted platelet suspensions of leukocytes by filtration and used a PCR-based RNA amplification step [switching mechanism at the 5' end of RNA templates (SMART)]. We tested the reliability and precision of the RNA amplification procedure by use of real-time PCR to measure quantities of specific transcripts: von Willebrand factor (vWF), A-subunit of coagulation factor XIII (F13A), and glyceraldehyde-3-phosphate dehydrogenase (GAPDH). Microarray analysis was performed on platelet RNA with and without amplification. RESULTS: Microgram quantities of platelet-specific cDNAs were produced from as little as 50 ng of total platelet RNA or 40 mL of whole blood. At cycle numbers <16, amplification of all transcripts tested was exponential with slightly more efficient amplification of low-abundance transcripts. Expression profiling of 9850 genes gave identical results for 9815 genes (1576 positive/8239 negative). Eight transcripts failed to be amplified by the SMART procedure. Expression of vWF, F13A, and GAPDH transcripts showed only minor day-to-day variations in three healthy individuals. CONCLUSION: The proposed protocol makes extremely small amounts of platelet RNA available for gene expression analysis in single patients.

Blood Platelets↗

Blood irradiator dosimetry with BANG polymer gels.

BACKGROUND: Transfusion-associated graft-versus-host disease is believed to be a preventable complication of blood transfusion in susceptible high-risk patients. Irradiation of allogeneic blood components is considered to be a safe and effective method inhibiting the proliferative capacity of lymphocytes. Physical factors that influence dose delivery include source and sample geometry, homogeneity of the dose distribution within the irradiation volume, and factors that influence dose absorption within the sample. STUDY DESIGN AND METHODS: Polymer gel dosimetry was used to evaluate the three-dimensional dose distribution for blood bags, platelet (PLT) bags, and syringes in typical geometries. RESULTS: The qualitative dose distribution within a cylindrical phantom determined with the polymer gel was in good agreement with the distribution in water determined with a DOSE-MAP film dosimetry system. Dose uniformity in blood bags and syringes was acceptable. Low signal strength and volume averaging hamper determination of the dose in PLT bags. CONCLUSION: Geometrical considerations in routine blood product irradiation may be evaluated with the use of polymer gel dosimetry. The procedures, however, are highly technical and are susceptible to low signal-to-noise and volume averaging considerations under certain geometrical configurations. Under clinical conditions, a reasonably uniform dose can be delivered to blood and blood components in a freestanding irradiator.

Acrylamides↗

Clinical benefits of continuous leukocyte filtration during cardiopulmonary bypass in patients undergoing valvular repair or replacement.

Valve operations in the form of repair or replacement make up a significant population of patients undergoing surgical procedures in the USA annually with the use of cardiopulmonary bypass. These patients experience a wide range of complications that are considered to be mediated by activation of complement and leukocytes. The extracorporeal perfusion circuit consists of multiple synthetic artificial surfaces. The biocompatibility of the blood contact surfaces is a variable that predisposes patients to an increased risk of complement mediation and activation. This can result in an inflammatory process, causing leukocytes to proliferate and sequester in the major organ systems. The purpose of this study was to determine whether filtration of activated leukocytes improved clinical outcomes following surgical intervention for valve repair or replacement. In this paper, we report a retrospective matched cohort study of 700 patients who underwent valve procedures from June 1999 to December 2002. The control group (CG) consisted of patients who had a conventional arterial line filter. In the study group (SG), patients had a conventional arterial line filter and a leukocyte arterial line filter (Pall Medical, NY). In the SG, blood diverted to the cardioplegia system was also leukocyte depleted to enhance myocardial preservation by adapting this device to the outflow port on the filter. Patient characteristics were similar for the SG and the CG, including 228 males and 122 females, mean age (62.4 versus 64.2 years), cardiopulmonary bypass time (127+/-64 versus 116+/-53 min), and aortic crossclamp time (84+/-23 versus 81+/-23 min). Our results demonstrate that the SG achieved statistically significant reduction in the time to extubation (p =0.03) and the number of patients with prolonged intubation in excess of 24 hours (p <0.04), in addition to improved postoperative oxygenation (p=0.01), and decreased length of hospital stay (p =0.03). We believe that leukocyte filters are clinically beneficial, as demonstrated by the results presented in this study.

Cardiopulmonary Bypass↗

Automated red cell collection--quality and value.

Automated red cell collection was initially used largely for therapeutic purposes. New technology has rendered the procedure safer for donors and easier for machine operators. Optimal additive solution can be automatically added and the red cells filtered to provide a leucodepleted product. Two units of red cells may be collected during a single procedure from individuals who have a high enough red cell mass, whilst a single unit of red cells plus platelets or plasma can be collected from smaller donors. In vitro studies suggested that red cells collected by automated methods would be of better quality than those collected by gravity. This was not confirmed in vivo, but red cells collected by automated methods have the major advantage of consistency in terms of haemoglobin content, volume and haematocrit, compared with red cells collected by gravity. This standardised product is of particular value for transfusion dependent patients as the patient's haemoglobin can be maintained within narrow limits. The use of a double dose red cell product for transfusion to a single patient also confers benefit in terms of reduction in donor exposure.

Automation↗

A multistate cluster of red blood cell transfusion reactions associated with use of a leucocyte reduction filter.

In 2000, the American Red Cross (ARC) received reports of unusual transfusion reactions of unknown aetiology among patients receiving leucocyte-reduced (LR) red blood cell (RBC) units in multiple distribution regions. We evaluated potential risk factors of reactions among patients who received LR-RBC transfusions. A case-patient was defined as any patient with onset of back pain while receiving an LR-RBC transfusion from 1 January to 25 May 2000. Controls were chosen randomly and selected in a 1:3 case : control ratio from healthcare facilities in which case-patients were transfused. Product-specific risk factors of reactions were further determined through nested case-control study, procedural review of blood collection facility and quality-control-testing record review of product processing. Reaction incidence rates were determined through ARC blood product distribution data by region of blood collection and processing. There were 29 reactions detected in patients who received transfusions in 13 healthcare facilities in five states. Eighteen case-patients and 78 controls were included in the case-control study. In univariate analysis, case-patients were more likely than controls to have a haematologic malignancy, to have received the transfusion as an outpatient, to have received an RBC transfusion within the previous 3 months, to have received medication used to prevent reactions or to diminish their intensity upon transfusion (i.e. premedication) or to have received LR-RBC units prepared with the HemaSure r\LS System(HS) rather than two other filters used. In multivariate analysis limited to recipients of HS-filtered RBC units, transfusion premedication [adjusted odds ratio (AOR) = 7; 95% confidence interval (CI) 1.4-37; P = 0.02] and transfusion as an outpatient (AOR = 5; 95% CI 1.1-20; P = 0.03) were independently associated with reactions. The rate of reported transfusion reactions was 2.0 reactions per 10 000 RBC units distributed. A multistate cluster of transfusion reactions was significantly associated with leucocyte filtration of RBC units prepared with a specific product, the HS filter. The reactions also were independently associated with premedication and transfusion as an outpatient; these may be surrogates for an increased risk of reaction or for greater likelihood of detection. The mechanism for these reactions has not been elucidated. This cluster of reactions underscores the importance of surveillance efforts to detect adverse events after transfusion, particularly when new methods to modify blood products are introduced.

Adolescent↗

Early complications in children with acute lymphoblastic leukemia presenting with hyperleukocytosis.

BACKGROUND: The optimal management of childhood acute lymphoblastic leukemia (ALL) with hyperleukocytosis is unclear, largely because the risk of leukostasis-related complications is poorly characterized. PROCEDURE: We reviewed the presenting characteristics, initial management, and frequency and type of complications in all children seen at St. Jude Children's Research Hospital with previously untreated ALL and an initial leukocyte count >200 x 10(9)/L. RESULTS: A total of 178 children, representing 8% of all children with ALL, had an initial leukocyte count >200 x 10(9)/L; 67 patients had a leukocyte count >400 x 10(9)/L. Sixteen patients (9%) had neurological complications with 12 of these patients experiencing symptoms at presentation. Four patients (2%), all with initial leukocyte counts >400 x 10(9)/L, suffered a CNS hemorrhage. Pulmonary leukostasis occurred in 11 patients (6%). The degree of hyperleukocytosis was significantly predictive of neurological (P = 0.006) and respiratory (P = 0.014) complications. The majority of complications occurred at presentation. Cytoreduction (94 patients) decreased the leukocyte count but delayed initiation of chemotherapy (P = 0.013). CONCLUSIONS: Serious leukostasis-related complications are relatively uncommon in childhood ALL and most occur at presentation. Their incidence increases in proportion to the leukocyte count. A large subset of cases can be managed successfully without cytoreduction. Cytoreduction may be considered for patients with leukocyte counts >400 x 10(9)/L or patients who have complications at presentation.

Acute Kidney Injury↗

Safety and efficacy of donor lymphocyte infusions following mismatched stem cell transplantation.

The use of a mismatched allograft necessitates T cell depletion for prevention of uncontrolled graft-versus-host disease (GVHD), thus impairing a graft-versus-leukemia effect. Data on donor lymphocyte infusion (DLI) after mismatched stem cell transplantation are lacking. Our experience with 28 patients (treated with 59 mismatched DLIs; range, 1-7) is described. The procedure was prophylactic in 6 patients (9 DLIs) and therapeutic in 22 (50 DLIs). DLI dose ranged from 10(2) to 1.5 x 10(9) T cells/kg. In the 6 patients receiving prophylactic DLI, complete remission was maintained in 5; however, 2 died from GVHD. Clinical response to therapeutic DLI was seen in 6 of 22 (27.3%) patients; a greater tumor burden produced a lower response. GVHD appeared in 13 of 28 patients. Surprisingly, a greater HLA mismatch was associated with a lower risk of GVHD, with 3 of 19 DLIs in 3/6 matching and 16 of 29 DLIs in 5/6 matching with similar follow-up. Nevertheless, no correlation between efficacy and HLA mismatching was noted. Death was frequent and usually related to the basic disease rather than to DLI complications. We conclude that mismatched DLI is feasible and may be effective, especially if given soon after transplantation. Future developments using cell therapy with selective or targeted anticancer activity are warranted, with special attention to prophylactic treatment of T cell depleted mismatched allografts recipients.

Acute Disease↗

Remission of proliferative lupus nephritis following B cell depletion therapy is preceded by down-regulation of the T cell costimulatory molecule CD40 ligand: an open-label trial.

OBJECTIVE: Autoreactive B cells play a key role in tissue injury in systemic autoimmune disease, and therefore a treatment resulting in B cell depletion could have benefit. This open-label study was undertaken to evaluate the efficacy of the anti-CD20 monoclonal antibody rituximab in the treatment of lupus nephritis. METHODS: Lupus patients with active proliferative nephritis (4 with focal disease and 6 with diffuse disease) received rituximab (4 weekly infusions of 375 mg/m(2)) combined with oral prednisolone. Clinical, laboratory, and immunologic responses, including peripheral lymphocyte subsets measured by flow cytometry, were prospectively assessed at monthly intervals for 12 months. Complete remission of nephritis was defined as normal serum creatinine and albumin levels, inactive urine sediment, and 24-hour urinary protein <500 mg. Partial remission was defined as >50% improvement in all renal parameters that were abnormal at baseline. RESULTS: B cell depletion lasted from 1 month to 7 months and was well tolerated. Partial remission was achieved in 8 of 10 patients within a median of 2 months (range 1-4 months); in 5 of them, complete remission was subsequently established (at a median of 3 months from baseline), and it was sustained at 12 months in 4. As early as 1 month from baseline, the expression of the costimulatory molecule CD40 ligand on CD4+ T cells was decreased by 4-fold, and it was almost blocked when partial remission was clinically evident. The expression of T cell activation markers CD69 and HLA-DR was significantly decreased at time points when partial remission was observed, and was further decreased during complete remission. In contrast, in patients who did not exhibit a response or when relapse was detected in patients in whom an initial remission had been achieved, such decreases were not prominent. Serum concentrations of double-stranded DNA autoantibodies were decreased in all patients, regardless of clinical outcome. CONCLUSION: Following B cell depletion, clinical remission of lupus nephritis is associated with a decrease in T helper cell activation, suggesting an additional role for B cells, independent of autoantibody production, in promoting disease. A controlled trial to confirm these promising clinical results is warranted.

Adult↗

B cell depletion therapy in systemic lupus erythematosus: effect on autoantibody and antimicrobial antibody profiles.

OBJECTIVE: Autoantibody production in patients with systemic lupus erythematosus (SLE) is associated with abnormalities of B cell function and phenotype. Clinical responses to B cell depletion therapy (BCDT), based on rituximab, are encouraging. Therefore, we undertook this study to investigate the effect of BCDT on antibody profiles. METHODS: Serial sera from 16 patients with active, refractory SLE were assayed for antinucleosome antibodies, anti-double-stranded DNA (anti-dsDNA), anti-extractable nuclear antigen, anti-tetanus toxoid, and antibodies to pneumococcal capsular polysaccharide for at least 1 year following BCDT. Anti-dsDNA antibodies derived from the V(H)4.34 immunoglobulin germ line gene (9G4+) were also measured. RESULTS: All patients achieved peripheral B cell depletion and improved clinically for at least 3 months. Antinucleosome and anti-dsDNA antibodies decreased to a mean +/- SD of 64 +/- 37% and 38 +/- 33% of baseline values, respectively, by 6-8 months post-BCDT. Levels of other autoantibodies and antimicrobial antibodies were generally unchanged. In the 9 of 16 patients who were still well at 1 year, anti-dsDNA antibodies fell to 42 +/- 36% of baseline values at 6-8 months and to 37 +/- 33% at 10-14 months. In patients who had disease flares within 1 year of BCDT, levels of these antibodies decreased to 60 +/- 40% and 83 +/- 93% of baseline values at 6-8 months and at 10-14 months, respectively. Circulating anti-dsDNA antibodies were positive for 9G4 expression in 4 of 6 patients tested, and flares in 2 of these patients were accompanied by rises in 9G4+ anti-dsDNA antibodies. CONCLUSION: These observations suggest that B cell clones committed to producing antinucleosome and anti-dsDNA antibodies, including the V(H)4.34 subpopulation of anti-dsDNA antibodies, have a relatively rapid turnover compared with B cell clones producing other antibodies. There was also a trend toward a greater and more sustained decrease in anti-dsDNA antibodies in patients with clinical benefit lasting >1 year.

Adolescent↗

Leucocyte depletion improves renal function during reperfusion using an experimental isolated haemoperfused organ preservation system.

BACKGROUND: Leucocytes have been implicated as mediators of renal ischaemia-reperfusion injury. This study aimed to demonstrate the effect of white cells in early renal reperfusion injury using an isolated haemoperfused porcine kidney model. METHODS: After 2 h cold storage, porcine kidneys were perfused with normothermic autologous blood using an isolated organ preservation system. This was designed using cardiopulmonary bypass technology, and perfusion commenced with a circulating serum creatinine level of 1000 micromol/l. In group 1 (n = 6) a leucocyte filter was included in the circuit and in group 2 (n = 6) non-filtered blood was used. RESULTS: The mean(s.d.) area under the curve for serum creatinine was lower in the leucocyte-depleted experiments (1286(214) versus 2627(418); P = 0.002). Leucocyte depletion also led to improved urine output (191(75) versus 70(32) ml/h; P = 0.002) and higher creatinine clearance (10.6(2.8) versus 1.9(1.0) ml/min; P = 0.002). Renal blood flow, oxygen consumption and acid-base homeostasis were all improved by perfusion with leucocyte-depleted blood, and histological tubular damage was ameliorated. CONCLUSION: These data show that the depletion of leucocytes from blood used to perfuse porcine kidneys improved postschaemic renal function, indicating that white cells play an important role in renal ischaemia-reperfusion injury.

Acid-Base Equilibrium↗

In vitro and in vivo properties of a dimeric bispecific single-chain antibody IgG-fusion protein for depletion of CCR2+ target cells in mice.

The chemokine receptor CCR2 is highly expressed on leukocytes in several inflammatory diseases of both mice and men. Apart from blockade of CCR2 to prevent chemokine-dependent cell migration, depletion of CCR2(+) cells might be a promising strategy for treatment of inflammatory diseases. We therefore designed a bispecific antibody construct with the ability to deplete CCR2(+) target cells in vitro and in vivo. The bispecific antibody construct consists of two single-chain antibody variable fragments (scFv) - one recognizing murine CD3epsilon and the other recognizing murine CCR2 - joined by a short linker and fused to a modified hinge region and the C(H)2 and C(H)3 domains of murine IgG1 for dimerization. The protein was expressed in mammalian cells and purified via its C-terminal histidine tail. In vitro this construct leads to efficient antigen-specific and costimulation-independent activation of T cells and strong lysis of CCR2(+) target cells. In vivo the construct induces an almost complete depletion of CCR2(+)CD11b(+) monocytes from the peripheral blood and spleens of BALB/c mice within 24 h. This recombinant protein construct is a dimeric, bispecific antibody with markedly improved serum levels compared to conventional bispecific single-chain antibodies and the ability to deplete CCR2(+)CD11b(+) monocytes in vivo.

Animals↗

Synthesis and performance of amphiphilic copolymers for blood cell separation.

Three types of amphiphilic copolymers using n-butylmethacrylate (BMA) as a hydrophobic monomer, and each of N,N'-dimethylacrylamide (DMA), N-acryloylmorpholine (AMO), and N-vinylpyrrolidone (VP) as hydrophilic comonomers were synthesized for coating filters used to remove leukocytes. The influence of the amphiphilic property of the resulting filters, which were composed of nonwoven fabrics coated with the above copolymers, on leukocyte removal and platelet permeation through the filters from whole blood was investigated. The platelet permeation ratio through hydrophobic noncoated filters was only 0.2%, because platelets in whole blood adhered easily to the hydrophobic filter material. However, filters coated with poly(AMO-co-BMA) of high AMO content showed a much higher platelet permeation ratio (nearly 90%). Further, the filters coated with poly(DMA-co-BMA) also showed high permeation ratios of platelets (more than 78%) over a broad range of DMA content in the copolymer. On the other hand, the coated filters showed slightly a higher permeation ratio of leukocytes than did the noncoated filters, resulting from the increase in hydrophilicity of the surface of the filters. Moreover, the coating of the amphiphilic copolymers on the surface of the nonwoven fabrics may have affected the pore size of the filters, affecting the permeation ratio of leukocytes more strongly than that of platelets. The coated filters effectively improved platelet permeation through the filters, with a slight increase in the permeation ratio of leukocytes.

Adsorption↗