PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Scanning Probe”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

The importance of molecular structure and conformation: learning with scanning probe microscopy.

Molecular structure holds a key to understanding Nature's intricate design mechanisms and blueprints. If we can understand her blueprints and basic materials, perhaps we can begin to mimic her beautiful products more cost effectively and with less detrimental environmental consequences. Higher resolution instrumentation has allowed us to study single molecules. Indeed, many stellar contributions to the field have come forth in the last couple of years. We can measure the forces required to unravel individual domains of biological molecules such as titin or DNA to a few picoNewtons resolution. This review will attempt to provide a general overview of the field of single molecule analysis using scanning force microscopy.

Adhesives↗

Progress in the application of scanning probe microscopy to biology.

Several key developments have occurred recently in the application of scanning probe microscopy to biology. These include the use of 'tapping-mode' atomic force microscopy both for the high-resolution imaging of biomolecules in liquids and for monitoring in situ biocatalysis, the use of atomic force microscopy as a force transducer to measure individual biological interactions, and the development of hybrid techniques such as scanning tunnelling microscopy coupled to confocal scanning laser microscopy.

Journal Article↗

Data analysis using the Internet: the World Wide Web scanning probe microscopy data analysis system.

The first interactive world-wide web-based image analysis system is presented (http://pharm6.pharm.nottingham.ac.uk/processing/main. html). The system, currently tailored to scanning probe microscopy image data, has been developed to permit the use of software algorithms developed within our laboratory by researchers throughout the world. The implementation and functionality of the scanning probe microscopy server is described. Feedback from users of the facility has demonstrated its value within the research community, and highlighted key operational issues which are to be addressed. A future role of Internet-based data processing software is also discussed.

Algorithms↗

[Scanning probe microscopy and medico-biological nanotechnology: history and prospects].

Literature data on the use of scanning probe microscopy for biological samples studying are presented. As an illustration, some results of the authors' investigations of the shark olfactory receptor surface, human lipoprotein of low density and human erythrocyte are given. Perspectives of the medico-biological development of nanotechnologies are evaluated.

Animals↗

Scanned probe microscopy of electronic transport in carbon nanotubes.

We use electrostatic force microscopy and scanned gate microscopy to probe the conducting properties of carbon nanotubes at room temperature. Multiwalled carbon nanotubes are shown to be diffusive conductors, while metallic single-walled carbon nanotubes are ballistic conductors over micron lengths. Semiconducting single-walled carbon nanotubes are shown to have a series of large barriers to conduction along their length. These measurements are also used to probe the contact resistance and locate breaks in carbon nanotube circuits.

Journal Article↗

Scaling-index method as an image processing tool in scanning-probe microscopy.

The scaling-index method (SIM) is a novel tool for image processing in scanning-probe microscopy. Originating from the theory of complex systems, the SIM can be used in order to extract structural information from arbitrary data sets. This method can readily be applied to the analysis of digital atomic-force microscopy (AFM) images. Especially for biomedical diagnostics, where genetic material is investigated by various microscopic methods, a reliable image segmentation based on the SIM algorithm is helpful. As a first application, AFM-images of GTG-banded human metaphase chromosomes (with G bands obtained by Trypsin using Giemsa) are compared with micrographs from conventional light microscopy by means of a scaling-index analysis. While the grey-level distributions of the optical and the AFM-images are largely different from each other, the scaling-index images are remarkably similar. Using this method, a fingerprint of an image can be produced which helps in the classification and interpretation of the measured data.

Algorithms↗

Single molecule imaging of supported planar lipid bilayer--reconstituted human insulin receptors by in situ scanning probe microscopy.

A 480-kDa disulfide-linked heterodimer single-pass transmembrane protein, the insulin receptor, is autophosphorylated upon insulin binding to its extracellular domain. Remarkably, the structural basis for this activation process remained largely unknown until the recent cryoelectron microscopy studies of the insulin-insulin receptor complex by Luo et al. [Science 285 (1999) 1077]. We report here the results of an in situ study by high-resolution scanning probe microscopy of the full-length insulin receptor reconstituted within supported planar lipid bilayers. Our preliminary studies confirm that (1) the intact receptor can be reconstituted constitutively within a lipid vesicle and (2) fusion of the receptor-containing vesicles to mica resulted in the formation of molecular flat 5.5-nm-thick supported planar bilayers populated by two populations of protrusions, the shape and size of which are consistent with those of the insulin receptor's intra- and extracellular domains as modeled by the cryo-EM data of Ottensmeyer et al. [Biochemistry 39 (2000) 12103]. These results establish a framework for real-time studies of insulin-insulin receptor binding by in situ SPM and single molecule force spectroscopy.

Aluminum Silicates↗

Scanning probe microscopy of biological samples and other surfaces.

Scanning probe microscopes derived from the scanning tunnelling microscope (STM) offer new ways to examine surfaces of biological samples and technologically important materials. The surfaces of conductive and semiconductive samples can readily be imaged with the STM. Unfortunately, most surfaces are not conductive. Three alternative approaches were used in our laboratory to image such surfaces. 1. Crystals of an amino acid were imaged with the atomic force microscope (AFM) to molecular resolution with a force of order 10(-8) N. However, it appears that for most biological systems to be imaged, the atomic force microscope should be able to operate at forces at least one and perhaps several orders of magnitude smaller. The substitution of optical detection of the cantilever bending for the measurement by electron tunnelling improved the reliability of the instrument considerably. 2. Conductive replicas of non-conductive surfaces enabled the imaging of biological surfaces with an STM with a lateral resolution comparable to that of the transmission electron microscope. Unlike the transmission electron microscope, the STM also measures the heights of the features. 3. The scanning ion conductance microscope scans a micropipette with an opening diameter of 0.04-0.1 micron at constant ionic conductance over a surface covered with a conducting solution (e.g., the surface of plant leaves in saline solution).

Crystallization↗

Covalent binding of biological samples to solid supports for scanning probe microscopy in buffer solution.

Scanning force microscopy allows imaging of biological molecules in their native state in buffer solution. To this end samples have to be fixed to a flat solid support so that they cannot be displaced by the scanning tip. Here we describe a method to achieve the covalent binding of biological samples to glass surfaces. Coverslips were chemically modified with the photoactivatable cross-linker N-5-azido-2-nitrobenzoyloxysuccinimide. Samples are squeezed between derivatized coverslips and then cross-linked to the glass surface by irradiation with ultraviolet light. Such samples can be imaged repeatedly by the scanning force microscope without loss of image quality, whereas identical but not immobilized samples are pushed away by the stylus.

Azides↗

Covalent immobilization of native biomolecules onto Au(111) via N-hydroxysuccinimide ester functionalized self-assembled monolayers for scanning probe microscopy.

We have worked out a procedure for covalent binding of native biomacromolecules on flat gold surfaces for scanning probe microscopy in aqueous buffer solutions and for other nanotechnological applications, such as the direct measurement of interaction forces between immobilized macromolecules, of their elastomechanical properties, etc. It is based on the covalent immobilization of amino group-containing biomolecules (e.g., proteins, phospholipids) onto atomically flat gold surfaces via omega-functionalized self-assembled monolayers. We present the synthesis of the parent compound, dithio-bis(succinimidylundecanoate) (DSU), and a detailed study of the chemical and physical properties of the monolayer it forms spontaneously on Au(111). Scanning tunneling microscopy and atomic force microscopy (AFM) revealed a monolayer arrangement with the well-known depressions that are known to stem from an etch process during the self-assembly. The total density of the omega-N-hydroxysuccinimidyl groups on atomically flat gold was 585 pmol/cm(2), as determined by chemisorption of (14)C-labeled DSU. This corresponded to approximately 75% of the maximum density of the omega-unsubstituted alkanethiol. Measurements of the kinetics of monolayer formation showed a very fast initial phase, with total coverage within 30 S. A subsequent slower rearrangement of the chemisorbed molecules, as indicated by AFM, led to a decrease in the number of monolayer depressions in approximately 60 min. The rate of hydrolysis of the omega-N-hydroxysuccinimide groups at the monolayer/water interface was found to be very slow, even at moderately alkaline pH values. Furthermore, the binding of low-molecular-weight amines and of a model protein was investigated in detail.

Enzymes, Immobilized↗

Potentiostatic deposition of DNA for scanning probe microscopy.

We describe a procedure for reversible adsorption of DNA onto a gold electrode maintained under potential control. The adsorbate can be imaged by scanning probe microscopy in situ. Quantitative control of a molecular adsorbate for microscopy is now possible. We found a potential window (between 0 and 180 mV versus a silver wire quasi reference) over which a gold (111) surface under phosphate buffer is positively charged, but is not covered with a dense adsorbate. When DNA is present in these conditions, molecules adsorb onto the electrode and remain stable under repeated scanning with a scanning tunneling microscope (STM). They become removed when the surface is brought to a negative charge. When operated at tunnel currents below approximately 0.4 nA, the STM yields a resolution of approximately 1 nm, which is better than can be obtained with atomic force microscopy (AFM) at present. We illustrate this procedure by imaging a series of DNA molecules made by ligating a 21 base-pair oligonucleotide. We observed the expected series of fragment lengths but small fragments are adsorbed preferentially.

Base Sequence↗

Piezoresistive sensors for scanning probe microscopy

In this article we summarize the efforts devoted to the realization of our ideas of the development of piezoresistive sensor family used in scanning probe microscopy. All the sensors described here are fabricated based on advanced silicon micromachining and standard CMOS processing. The fabrication scenario presented in this article allows for the production of different sensors with the same tip deflection piezoresistive detection scheme. In this way we designed and fabricated, as a basic sensor, piezoresistive cantilever for atomic force microscopy, which enables surface topography measurements with a resolution of 0.1 nm. Next, by introducing a conductive tip isolated from the beam we obtained a microprobe for scanning capacitance microscopy and scanning tunneling microscopy. With this microprobe we measured capacitance between the microtip and the surface in the range of 10(-22) F. Furthermore, a modification of the piezoresistors placement, based on the finite element method (FEM) simulation permits fabrication of the multipurpose sensor for lateral force microscopy, which enables measurements of friction forces with a resolution of 1 nN. Finally, using the same basic device idea and only slightly modified process sequence we manufactured femtocalorimeter for the detection of heat energy in the range of 50 pJ.

Journal Article↗

Bioreactive self-assembled monolayers on hydrogen-passivated Si(111) as a new class of atomically flat substrates for biological scanning probe microscopy.

This is the first report of bioreactive self-assembled monolayers, covalently bound to atomically flat silicon surfaces and capable of binding biomolecules for investigation by scanning probe microscopy and other surface-related assays and sensing devices. These monolayers are stable under a wide range of conditions and allow tailor-made functionalization for many purposes. We describe the substrate preparation and present an STM and SFM characterization, partly performed with multiwalled carbon nanotubes as tapping-mode supertips. Furthermore, we present two strategies of introducing in situ reactive headgroup functionalities. One method entails a free radical chlorosulfonation process with subsequent sulfonamide formation. A second method employs singlet carbenemediated hydrogen-carbon insertion of a heterobifunctional, amino-reactive trifluoromethyl-diazirinyl crosslinker. We believe that this new substrate is advantageous to others, because it (i) is atomically flat over large areas and can be prepared in a few hours with standard equipment, (ii) is stable under most conditions, (iii) can be modified to adjust a certain degree of reactivity and hydrophobicity, which allows physical adsorption or covalent crosslinking of the biological specimen, (iv) builds the bridge between semiconductor microfabrication and organic/biological molecular systems, and (v) is accessible to nanopatterning and applications requiring conductive substrates.

Alkanes↗

Characterization of Grafted Poly(ethylene glycol) on Si Wafers Using Scanning Probe Microscopy.

The uniformity and surface topography of grafted poly(ethylene glycol) (PEG) coatings were characterized at the microscale as a function of grafting temperature (grafting density) using scanning probe microscopy. Images of PEG-coated silicon wafers show isolated domains which decrease in size and increase in surface density with increasing grafting temperature. Domain sizes appeared to correlate with the polarity of the solvent used for imaging. Roughness measurements of the PEG layers were obtained. The results are relevant in relation to the biomedically significant ability of PEG coatings to mask surface features such as charge detected via zeta potential measurements. Copyright 1998 Academic Press.

Journal Article↗

High resolution imaging of native biological sample surfaces using scanning probe microscopy.

The possibility of acquiring high resolution topographs using scanning probe microscopes under physiological conditions allows the observation of biomolecules at work. Progress has recently been made in imaging protein-DNA complexes, individual oligomers and protein arrays. Scanning probe microscopes are now tools that complement X-ray crystallography and electron microscopy.

Bacterial Outer Membrane Proteins↗

The role of scanning probe microscopy in drug delivery research.

The success of a drug delivery system is often dependent on the surface properties of the device. These surface properties will determine the complex dynamic interfacial events that occur when the system is introduced into the aqueous environment of a patient. Development of the scanning probe microscopes has provided a number of very powerful new surface analytical techniques that are making a significant contribution to the characterization of drug delivery systems and the interfacial processes that occur when such systems are exposed to aqueous living environments. In this review, we describe the design and attributes of these instruments and discuss the impact of the techniques on a wide range of drug delivery research. The scanning probe microscopes are providing new insights into important problems concerning drug delivery, including the molecular structure of polymeric biomaterial surfaces, the conformation of target biomolecules, the influence of morphology on biodegradation, the adsorption of proteins to synthetic surfaces, and the structure and interactions of colloidal particles. As the whole field of scanning probe microscopy continues to advance, drug delivery research is set to benefit; in the final section of the review, the future potential derived from the ability to characterize new surface properties under aqueous conditions is discussed.

Drug Delivery Systems↗

Detecting H+ in ultrafine ambient aerosol using iron nano-film detectors and scanning probe microscopy.

Recent epidemiological evidence strongly suggests that ambient-particle-associated acidity is more closely correlated with total mortality and hospital admissions for respiratory disease than indices of total particulate mass. In addition, evidence is accumulating to support the hypothesis that the number of ultrafine (d < or = 200 nm) acid particles, rather than ambient mass, is an important determining factor affecting lung injury. Both outdoor and indoor air environments are dominated by nanometer-sized particles. However, no data are currently available on the size distribution or number concentration of acidic ambient ultrafine particles largely because there are no suitable methods for measuring these important quantities. We have developed a method to accomplish these measurements based on the use of iron nano-films for detection of acid droplets. Detectors were prepared by vapor deposition of iron onto 12-mm-diameter glass cover slips. The detectors develop reaction sites when exposed to H2SO4 or NH4HSO4 particles. Exposures to non-acidic particle (NaCl and [(NH4)]2SO4) result in no detectable surface deformations. The nano-films are examined with scanning probe microscopy (SPM) for the enumeration of reaction sites. Until recently, direct visualization of individual objects smaller than 200 nm has been possible only with electron microscopy. The advancement of SPM provides the opportunity to examine the detector surface features with high quality three dimensional imaging.

Aerosols↗

Scanning probe microscopies for high-resolution characterization of electrochemical sensors. Plenary lecture.

A better understanding of tailored electrodes and electrochemical sensors requires a more detailed picture of their surfaces. New scanning probe techniques, such as scanning tunnelling or scanning bioelectrochemical microscopies, offer unique opportunities for high-resolution in situ characterization of tailored electrodebased sensors. Scanning tunnelling microscopy provides valuable information on the topography of pre-treated surfaces, the heterogeneity of composite electrodes, the morphology of electropolymerized films, the packing arrangement of adsorbed monolayers and the microdistribution of immobilized biological components. Scanning bioelectrochemical microscopy is shown to be extremely useful for the mapping of localized biological activity and the monitoring of dynamic biological events. Valuable insights are achieved by correlating the structural features with the preparation/modification conditions and the subsequent sensing performance. Such correlations can facilitate the predictive design of increasingly better sensors.

Biosensing Techniques↗