PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Neutron Capture Therapy”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Present status and perspectives of boron neutron capture therapy.

Boron neutron capture therapy (BNCT) is a mode of radiotherapy with great attractiveness, but also with a burden of past failure. In this review, the principles of BNCT, the reasons for its past failure, its present clinical application, and the on-going developmental work towards clinical trials are described.

Animals↗

Selective delivery of 10B to soft tissue sarcoma using 10B-L-borophenylalanine for boron neutron capture therapy.

Boron neutron capture therapy (BNCT) may improve the locoregional control of radio/chemoresistant tumours like soft tissues sarcomas (STS). This technique uses the 10B(n,alpha)7Li nuclear reaction to destroy tumour cells, provided that a sufficient amount of 10B may be carried selectively into them. In order to evaluate the targeting potential of 10B-L-borophenylalanine (BPA) a 10B biodistribution study was carried out in 24 Wistar rats bearing Yoshida sarcoma. Six animals received increasing intraperitoneal doses of BPA (300, 600 and 1200 mg kg-1), while the remainder received a BPA dose of 600 mg kg-1 but with a sacrifice at six different time points: 1, 2, 4, 6, 9 and 12 h. The 10B concentrations in the tumours, normal tissues and blood were analysed with neutron capture radiography (NCR). The analysis shows that 36 micrograms g-1 (+/- 4 SD) of 10B may be incorporated into the tumour, with a ratio of 13 (+/- 4 SD) versus the muscle and a ratio of 15 (+/- 3 SD) versus the blood, 6 h after an intraperitoneal injection of 600 mg kg-1 of BPA. The BPA appears to be abundantly incorporated in the tumour, and the kidney proximal tubule area. These data suggest that BNCT using BPA may provide an improved therapeutic ratio for the treatment of STS.

Animals↗

Cell cycle dependence of boron uptake from two boron compounds used for clinical neutron capture therapy.

In neutron capture therapy, it is important that the boron is selectively uptaken by tumor cells. In the present study, we used flow cytometry to sort the cells in the G0/G1 phase and those in the G2/M phase, and the boron concentration in each fraction was measured with inductively coupled plasma atomic emission spectroscopy. The results revealed that sodium borocaptate and boronophenylalanine (BPA), were associated with higher rates of boron uptake in the G2/M than in the G0/G1 phase. However, the difference was more prominent in the case of BPA. The G2/M:G0/G1 ratio decreased as a function of exposure time in BPA containing culture medium, thereby indicating the cell cycle dependency of BPA uptake. Such heterogeneity of boron uptake by tumor cells should be considered for microdosimetry.

Animals↗

Carboranyl bisglycosides for the treatment of cancer by boron neutron capture therapy.

Boron neutron capture therapy is a special type of radiotherapy for the treatment of cancer by using boron compounds. Problems often arise from the low water solubility of these compounds, their unselective uptake into the cancer cells, and their toxicity. Here we describe the novel water-soluble ortho-carboranyl bisglycosides 7 and 10 containing either lactose or glucose and the mixed bisglycosides 1 and 28 containing glucose, mannose, and galactose. The carboranyl bisglycosides show almost no toxicity toward bronchial carcinoma cells of line A549 up to a concentration of 0.50 mM. As anticipated, these compounds exhibit nearly no uptake into C6 glioma cells; they can therefore be used for a selective delivery into malignant cells by using conjugates of glycohydrolases and monoclonal antibodies which bind to tumor-associated antigens, since by enzymatic hydrolysis the bisglycosides are transformed into lipophilic compounds.

Antineoplastic Agents↗

Ion microscopy imaging of 10B from p-boronophenylalanine in a brain tumor model for boron neutron capture therapy.

Boron neutron capture therapy (BNCT), a binary treatment modality that can potentially irradiate tumor tissue within cellular dimensions, is critically dependent on the preferential delivery of 10B to individual neoplastic cells. In this study, ion microscopy was used to quantitatively evaluate the selectivity of p-boronophenylalanine-fructose (BPA-F) in the rat 9L gliosarcoma brain tumor model. With a spatial resolution of approximately 0.5 microm, ion microscopy images show that BPA-F delivers 3.5 times more boron to the main tumor mass [99 +/- 36 microg/g tissue (mean +/- SD)] than to the contiguous normal brain (27 +/- 12 microg/g tissue). A similar, but lower, accumulation was observed away from the main tumor mass in small clusters of neoplastic cells (47 +/- 15 microg/g tissue) invading the surrounding brain (16 +/- 8 microg/g tissue). These findings establish for the first time the selectivity of BPA-F to the neoplastic cells invading the normal brain and provide a much-needed baseline measurement of the distribution of a clinically approved BNCT drug. Given the propensity for malignant brain tumors to infiltrate the surrounding normal brain, these observations have particular significance for clinical trials of BNCT for human glioblastoma multiforme using the drug BPA-F.

Animals↗

Intracellular distribution of various boron compounds for use in boron neutron capture therapy.

The neutron capture reaction in boron (10B(n, alpha)7Li) generates two short-range particles with high linear energy transfer. The effect of neutron capture therapy depends on the selective localization of 10B atoms in target cells. The determination of the distribution of boron compounds in cancer cells at the subcellular level is required for the understanding of the effect of this treatment. The monomeric sulfhydryl borane (BSH) compound has been used clinically in Japan and preclinically in the U.S.A. Recently, new compounds have been developed: a dimeric sulfhydryl borane (BSSB), a boronophenylalanine (BPA), and two porphyrin complexes (BOPP and VCDP). This study demonstrates that the porphyrin complexes (BOPP and VCDP) are more cytotoxic than the other three compounds to the rat 9L gliosarcoma cell line. Using atomic absorption spectrophotometry to determine boron content for cellular uptake studies of these agents, we found that of the five compounds tested BOPP (25 microM) exposure resulted in the greatest boron uptake averaging 305 ng B/10(6) cells. BSSB (500 microM) was second averaging 93 ng B/10(6) cells, BSH (500 microM) third averaging 62 ng B/10(6) cells, VCDP (25 microM) fourth averaging 58 ng B/10(6) cells, and BPA (500 microM) fifth averaging 7.4 ng B/10(6) cells. Data on the distribution of boron in the nuclei, mitochondria, lysosomes, microsomes, and cytosomes of 9L cells are also presented.

Animals↗

Ligand liposomes and boron neutron capture therapy.

Boron neutron capture therapy (BNCT) has been used both experimentally and clinically for the treatment of gliomas and melanomas, with varying results. However, the therapeutic effects on micro-invasive tumor cells are not clear. The two drugs that have been used clinically, p-boronophenylalanine, (BPA), and the sulfhydryl borane, (BSH), seem to be taken up preferentially in solid tumor areas but it is uncertain whether enough boron is taken up by micro-invasive tumor cells. To increase the selective uptake of boron by such cells, would be to exploit tumor transformation related cellular changes such as over-expression of growth factor receptors. However, the number of receptors varies from small to large and the uptake of large amounts of boron for each receptor interaction is necessary in order to deliver sufficient amounts of boron. Therefore, each targeting moiety must deliver large number of boron atoms. One possible way to meet these requirements would be to use receptor-targeting ligand liposomes, containing large number of boron atoms. This will be the subject of this review and studies of boron containing liposomes, with or without ligand, will be discussed. Two recent examples from the literature are ligand liposomes targeting either folate or epidermal growth factor (EGF) receptors on tumor cells. Other potential receptors on gliomas include PDGFR and EGFRvIII. Besides the appropriate choice of target receptor, it is also important to consider delivery of the ligand liposomes, their pharmacodynamics and pharmacokinetics and cellular processing, subjects that also will be discussed in this review.

Animals↗

A critical assessment of boron target compounds for boron neutron capture therapy.

Boron neutron capture therapy (BNCT) has undergone dramatic developments since its inception by Locher in 1936 and the development of nuclear energy during World War II. The ensuing Cold War spawned the entirely new field of polyhedral borane chemistry, rapid advances in nuclear reactor technology and a corresponding increase in the number to reactors potentially available for BNCT. This effort has been largely oriented toward the eradication of glioblastoma multiforme (GBM) and melanoma with reduced interest in other types of malignancies. The design and synthesis of boron-10 target compounds needed for BNCT was not channeled to those types of compounds specifically required for GBM or melanoma. Consequently, a number of potentially useful boron agents are known which have not been biologically evaluated beyond a cursory examination and only three boron-10 enriched target species are approved for human use following their Investigational New Drug classification by the US Food and Drug Administration; BSH, BPA and GB-10. All ongoing clinical trials with GBM and melanoma are necessarily conducted with one of these three species and most often with BPA. The further development of BNCT is presently stalled by the absence of strong support for advanced compound evaluation and compound discovery driven by recent advances in biology and chemistry. A rigorous demonstration of BNCT efficacy surpassing that of currently available protocols has yet to be achieved. This article discusses the past history of compound development, contemporary problems such as compound classification and those problems which impede future advances. The latter include means for biological evaluation of new (and existing) boron target candidates at all stages of their development and the large-scale synthesis of boron target species for clinical trials and beyond. The future of BNCT is bright if latitude is given to the choice of clinical disease to be treated and if a recognized study demonstrating improved efficacy is completed. Eventually, BNCT in some form will be commercialized.

Animals↗

Quantitative imaging and microlocalization of boron-10 in brain tumors and infiltrating tumor cells by SIMS ion microscopy: relevance to neutron capture therapy.

Boron neutron capture therapy (BNCT) is dependent on the selective accumulation of boron-10 in tumor cells relative to the contiguous normal cells. Ion microscopy was used to evaluate the microdistribution of boron-10 from p-boronophenylalanine (BPA) in the 9L rat gliosarcoma and the F98 rat glioma brain tumor models. Four routes of BPA administration were used: i.p. injection, intracarotid (i.c.) injection [with and without blood-brain barrier disruption (BBB-D)], and continuous timed i.v. infusions. i.p. injection of BPA in the 9L gliosarcoma resulted in a tumor-to-brain (T:Br) boron-10 concentration ratio of 3.7:1 when measured at the tumor-normal brain interface. In the F98 glioma, i.c injection of BPA resulted in a T:Br ratio of 2.9:1, and this increased to 5.4:1 when BBB-D was performed. The increased tumor boron uptake would potentially enhance the therapeutic ratio of BNCT by >25%. At present, ion microscopy is the only technique to provide a direct measurement of the T:Br boron-10 concentration ratio for tumor cells infiltrating normal brain. In the 9L gliosarcoma, this ratio was 2.9:1 after i.p. administration. In the F98 glioma, i.c injection resulted in a ratio of 2.2:1, and this increased to 3.0:1 after BBB-D. Ion microscopy revealed a consistent pattern of boron-10 microdistribution for both rat brain tumor models. The boron-10 concentration in the main tumor mass (MTM) was approximately twice that of the infiltrating tumor cells. One hour after a 2-h i.v. infusion of BPA in rats with the 9L gliosarcoma, tumor boron-10 concentrations were 2.7 times higher than that of infiltrating tumor cells [83 +/- 23 microg/g tissue versus 31 +/- 12 microg/g tissue (mean +/- SD)]. Continuous 3- and 6-h i.v. infusions of BPA in the 9L gliosarcoma resulted in similar high boron-10 concentrations in the MTM. The boron-10 concentration in infiltrating tumor cells was two times lower than the MTM after a 3-h infusion. After 6 h, the boron-10 concentration in infiltrating tumor cells had increased nearly 90% relative to the 2- and 3-h infusions. A 24-h i.v. infusion resulted in similar boron-10 levels between the MTM and the infiltrating tumor cells. Boron concentrations in the normal brain were similar for all four infusion times (approximately 20 microg/g tissue). These results are important for BNCT, because clinical protocols using a 2-h infusion have been performed with the assumption that infiltrating tumor cells contain equivalent amounts of boron-10 as the MTM. The results reported here suggest that this is not the case and that a 6-h or longer infusion of BPA may be necessary to raise boron-10 levels in infiltrating tumor cells to that in the MTM.

Animals↗

A new approach for the synthesis of isonitrile carborane derivatives. Ligands for metal based boron neutron capture therapy (BNCT) and boron neutron capture synovectomy (BNCS) agents.

A new approach for the synthesis of carborane isonitrile derivatives was developed. This approach involved the dehydration of both boron and carbon derived formamides using the Burgess reagent. The products, some of which were characterized by X-ray crystallography, can now be used as ligands for the synthesis of transition metal based boron neutron capture therapy and synovectomy agents and targeted radiopharmaceuticals.

Journal Article↗

Study of boron neutron capture therapy used neutron source with protons bombarding a thick 9Be target.

Neutron sources created by 4-, 3.5-, and 3-MeV protons striking a thick beryllium target were studied via the time-of-flight technique. Protons were accelerated by the Peking University 4.5 MV electrostatic accelerator. Two disk-shaped 9Be targets with thickness 1.5 and 3 mm were used in the measurements. The time-of-flight spectra were observed at zero degrees with respect to the incident proton beam. The analysis to these time-of-flight spectra is given. The time-of-flight spectra were converted to the energy spectra and compared to a neutron spectrum of 7Li(p, n)7 Be reaction with incident energy 2.5 MeV, which was also measured in this work. Restricted by the spectrometer itself, the threshold of the measurements is 400 keV. The results show that by using several MeV protons bombarding a thick beryllium target, reactions other than 9Be(p, n)9B produce significant contributions to the neutron yield with energy less than 1 MeV.

Beryllium↗

Gadolinium incorporated reconstituted chylomicron emulsion for potential application in tumor neutron capture therapy.

Gadolinium (Gd) neutron capture therapy (NCT) is currently under development as a potential approach for tumor therapy. Nanoparticles have been suggested as a potential delivery system to carry or target Gd to tumors for thermal or epithermal neutron irradiation. The reconstituted chylomicron emulsion is an artificial chylomicron remnant prepared using commercially available natural and biocompatible lipids. We proposed to use this nanometer-scale emulsion to deliver Gd to solid tumors by modifying the surface of the emulsion. A lipophilic Gd compound, gadolinium acetylacetonate (GdAcAc), was incorporated into the emulsion, resulting in a final pure Gd concentration of more than 1 mg/mL. The apparent solubility of GdAcAc was enhanced by about 6000-fold by this incorporation. The emulsion particles were shown to be stable in a two-week short-term stability study when stored at 4 degrees C. In addition, no extensive particle aggregation was observed when the emulsion particles were incubated in simulated biological media such as serum. Also, GdAcAc does not significantly 'leak' out from the emulsion particles. Only approximately 5% was released in 20 h in a SDS (0.5% w/v) in phosphate buffered saline (pH 7.4, 10 mM) medium. Finally, the emulsion particles were coated with polyethylene glycol (PEG), and injected into Balb/C mice via the tail vein. A significant proportion (71.6 +/- 18.4%) of the PEG-coated, GdAcAc-incorporated emulsion remained circulating in the blood 5 h after the injection, while the PEG-free emulsion was mainly accumulated inside the liver. This chylomicron emulsion may be used to deliver Gd into solid tumors for NCT.

Animals↗

Dose distributions in a human head phantom for neutron capture therapy using moderated neutrons from the 2.5 meV proton-7Li reaction or from fission of 235U.

The feasibility of neutron capture therapy (NCT) using an accelerator-based neutron source of the 7Li(p,n) reaction produced by 2.5 MeV protons was investigated by comparing the neutron beam tailored by both the Hiroshima University radiological research accelerator (HIRRAC) and the heavy water neutron irradiation facility in the Kyoto University reactor (KUR-HWNIF) from the viewpoint of the contamination dose ratios of the fast neutrons and the gamma rays. These contamination ratios to the boron dose were estimated in a water phantom of 20 cm diameter and 20 cm length to simulate a human head, with experiments by the same techniques for NCT in KUR-HWNIF and/or the simulation calculations by the Monte Carlo N-particle transport code system version 4B (MCNP-4B). It was found that the 7Li(p,n) neutrons produced by 2.5 MeV protons combined with 20, 25 or 30 cm thick D20 moderators of 20 cm diameter could make irradiation fields for NCT with depth-dose characteristics similar to those from the epithermal neutron beam at the KUR-HWNIF.

Head↗

Are gadolinium contrast agents suitable for gadolinium neutron capture therapy?

OBJECTIVE: Gadolinium neutron capture therapy (GdNCT) is a potential treatment for malignant tumors based on two steps: (1) injection of a tumor-specific (157)Gd compound; (2) tumor irradiation with thermal neutrons. The GdNC reaction can induce cell death provided that Gd is proximate to DNA. Here, we studied the nuclear uptake of Gd by glioblastoma (GBM) tumor cells after treatment with two Gd compounds commonly used for magnetic resonance imaging, to evaluate their potential as GdNCT agents. METHODS: Using synchrotron X-ray spectromicroscopy, we analyzed the Gd distribution at the subcellular level in: (1) human cultured GBM cells exposed to Gd-DTPA or Gd-DOTA for 0-72 hours; (2) intracerebrally implanted C6 glioma tumors in rats injected with one or two doses of Gd-DOTA, and (3) tumor samples from GBM patients injected with Gd-DTPA. RESULTS: In cell cultures, Gd-DTPA and Gd-DOTA were found in 84% and 56% of the cell nuclei, respectively. In rat tumors, Gd penetrated the nuclei of 47% and 85% of the tumor cells, after single and double injection of Gd-DOTA, respectively. In contrast, in human GBM tumors 6.1% of the cell nuclei contained Gd-DTPA. DISCUSSION: Efficacy of Gd-DTPA and Gd-DOTA as GdNCT agents is predicted to be low, due to the insufficient number of tumor cell nuclei incorporating Gd. Although multiple administration schedules in vivo might induce Gd penetration into more tumor cell nuclei, a search for new Gd compounds with higher nuclear affinity is warranted before planning GdNCT in animal models or clinical trials.

Animals↗

Toward clinical application of prompt gamma spectroscopy for in vivo monitoring of boron uptake in boron neutron capture therapy.

In boron neutron capture therapy (BNCT) the absorbed dose to the tumor cells and healthy tissues depends critically on the boron uptake. Pronounced individual variations in the uptake patterns have been observed for two boron compounds currently used in clinical trials. This implies a high uncertainty in the determination of the boron dose component. In the present work a technique known as prompt gamma spectroscopy (PGS) is studied that potentially can be used for in vivo and noninvasive boron concentration determination at the time of the treatment. The technique is based upon measurement of gamma rays promptly emitted in the 10B(n,alpha)7Li and 1H(n,gamma)2D reactions. The aim of this work is to prepare the present setup for clinical application as a monitor of boron uptake in BNCT patients. Therefore, a full calibration and a set of phantom experiments were performed in a clinical setting. Specifically, a nonuniform boron distribution was studied; a skin/ dura, a larger blood vessel, and tumor within a head phantom was simulated. The results show that it is possible to determine a homogeneous boron concentration of 5 microg/g within +/-3% (1 standard deviation). In the nonuniform case, this work shows that the boron concentration can be determined through a multistep measurement procedure, however, with a somewhat higher uncertainty (approximately 10%). The present work forms the basis for a subsequent clinical application of the PGS setup aimed at in vivo monitoring of boron uptake.

Blood Vessels↗