PubMed HealthSearch

SEARCH · PubMed Health

Results for “Optimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Oxytocin precipitation of prostaglandin-induced farrowing in swine: determination of the optimal dose of oxytocin and optimal interval between prostaglandin F2 alpha and oxytocin.

The influence of dose of oxytocin and the interval between prostaglandin (PG) F2 alpha and oxytocin administration on the synchrony of farrowing, the prevalence of intrapartum complications, and the number of pigs dying perinatally was investigated. In study 1, sows were given 10 mg of PGF2 alpha IM on day 112, 113, or 114 of gestation or were not treated. Twenty hours after PGF2 alpha administration, sows were given 0, 5, 10, 20, or 30 USP U of oxytocin IM. Sows treated with PGF2 alpha or PGF2 alpha plus oxytocin had a shorter interval to farrowing than sows not treated or treated with oxytocin alone. Treatment with PGF2 alpha plus 30 U of oxytocin induced the most rapid onset and the greatest synchrony of farrowing, with the mean onset occurring 2.1 +/- 0.4 hours after oxytocin vs greater than 8 hours for all other treatments. Sows treated with 5 or 10 U of oxytocin had a delayed onset and a less synchronous farrowing, compared with sows treated with 0 or 20 U. Day of PGF2 alpha treatment influenced (P less than 0.05) the interval from oxytocin to onset of farrowing. As day during gestation decreased, there was a corresponding decrease in the interval between oxytocin administration and farrowing. Number of interventions to remove retained pigs was not influenced (P greater than 0.05) by day of PGF2 alpha administration. All sows treated with PGF2 alpha followed by oxytocin had a higher rate of manual interventions, compared with that in sows given PGF2 alpha but not oxytocin.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

[Principles of optimization and scaling of certain processes in the vaccine production technology. 3. Method of determination of the optimal method of thermal sterilization of sugar solutions].

One of the most widespread methods of thermal sugar sterilization is the use of saturated water vapour under pressure in the capacity of heat source. Guaranteed sterility of solutions should be reached under conditions providing the least sugar splitting. However, in practice the integral effect of the thermal field on the solution is as a rule not taken into consideration. A new calculation method permitting to determine the amount of sugar split in the varying thermal field.

Carbohydrates

Optimal constant positive airway pressure assessed by arterial alveolar difference for CO2 in hyaline membrane disease.

In a group of infants with hyaline membrane disease, the level of optimal constant positive airway pressure (CPAP) was assessed by raising CPAP in small steps from an initial low value, and after each change measuring the arterial alveolar difference for CO2 (aADCO2) and transmission of airway pressure to the esophagus. Below optimal CPAP there was a progressive increase in mixed alveolar partial pressure of CO2 (PACO2) and no change in arterial partial pressure of CO2 (PaCO2), so that aADCO2 declined and reached a lowest value at optimal CPAP. Correspondingly, transmission of airway pressure increased progressively and reached a highest value at optimal CPAP. Between 1 step below and optimal CPAP, PACO2 rose from 30.9 to 34.0 torr, and aADCO2 declined from 16.6 to 12.7 torr. Between optimal and 1 step above optimal CPAP, PaCO2 increased from 46.7 to 51.0 torr, PACO2 rose slightly, and aADCO2 increased from 12.7 to 15.6 torr. Thus, the aADCO2 was an excellent index of optimal CPAP. In five patients with measurements of PaO2 at constant fractional inspired oxygen, calculated values for arterial oxygen saturation changed from 80.8 to 91.5 to 92.2%, and calculated values for venous admixture changed from 0.61 to 0.48 to 0.46 as CPAP was raised from 1 step below through optimal to 1 step above optimal CPAP. The results are interpreted to mean a progressive improvement in perfusion of well ventilated lung units as CPAP increased to optimal levels, but a significant reduction of both ventilation and perfusion above optimal CPAP.(ABSTRACT TRUNCATED AT 250 WORDS)

Carbon Dioxide

Optimizing model: insemination, replacement, seasonal production, and cash flow.

Dynamic programming to solve the Markov decision process problem of optimal insemination and replacement decisions was adapted to address large dairy herd management decision problems in the US. Expected net present values of cow states (151,200) were used to determine the optimal policy. States were specified by class of parity (n = 12), production level (n = 15), month of calving (n = 12), month of lactation (n = 16), and days open (n = 7). Methodology optimized decisions based on net present value of an individual cow and all replacements over a 20-yr decision horizon. Length of decision horizon was chosen to ensure that optimal policies were determined for an infinite planning horizon. Optimization took 286 s of central processing unit time. The final probability transition matrix was determined, in part, by the optimal policy. It was estimated iteratively to determine post-optimization steady state herd structure, milk production, replacement, feed inputs and costs, and resulting cash flow on a calendar month and annual basis if optimal policies were implemented. Implementation of the model included seasonal effects on lactation curve shapes, estrus detection rates, pregnancy rates, milk prices, replacement costs, cull prices, and genetic progress. Other inputs included calf values, values of dietary TDN and CP per kilogram, and discount rate. Stochastic elements included conception (and, thus, subsequent freshening), cow milk production level within herd, and survival. Validation of optimized solutions was by separate simulation model, which implemented policies on a simulated herd and also described herd dynamics during transition to optimized structure.

Animals

Geometric optical optimization of the corneal lens of Notonecta glauca.

The optimal shape of the corneal lens of the water bug backswimmer (Notonecta glauca) and the optimal shape and position of the thin transition layer between the distal and proximal units of its cornea are theoretically determined. Using a geometric optical method, first the shape of a geometric interface between the lens units is determined, which eliminates the longitudinal spherical aberration. This interface is investigated for differently formed thick lenses when the medium in contact with the entrance surface of the lens is water or air. The optimal transition layer for the amphibious backswimmer is that, the boundaries of which are the theoretical interfaces for water and air, and the refractive index varies continuously in it. The optimal shape of the corneal lens is determined, with the disadvantageous lenses, with respect to the possible minimal spherical aberration and amount of reflected light from the transition layer, being rejected. The optimal position of the transition layer in the cornea can be obtained from the minimization of the amount of diffracted light on the marginal connection of the layers. The optimal corneal lens for backswimmer has ellipsoid boundary surfaces; the optimal transition layer in it is thin bell-shaped, at the marginal connection of which there is no dimple, the maximum of the layer is on the margin of the cornea. The shape of the theoretically optimal corneal lens, the shape and position of the theoretically optimal transition layer agree well with those of Notonecta glauca. The question posed, the geometric optical method used and the results presented are of general importance, and not only with respect to vision in the bug Notonecta, but also in the fossil trilobites, or in the wave guide theories which have been employed in similar modelling problems, in design of system of lenses without spherical aberration, for example.

Amphibians

Reduced optimality as an indicator of developmental status at 18 months and school achievement at 8 years.

Birth records of 97 children assessed at 18 months and found to be developmentally delayed were scored according to the optimality concept developed by Prechtl. These children were compared to a control series of 81 children. In order to evaluate the predictive validity of the parental developmental assessments performed at 18 months the children had been screened for school achievement problems at the age of eight years, yielding a distribution of true and false positives and true and false negatives. Rates of reduced optimality were compared to investigate firstly, the relationship between reduced optimality and developmental delay at 18 months and secondly, whether the follow-up distribution of true and false positives at eight years could be related to reduced optimality. The overall relationship between reduced optimality and developmental delay at 18 months and reduced optimality and school achievement problems at eight years was also investigated. The 15 low scoring cases registered as mentally retarded differed significantly from controls on total mean reduced optimality. Retarded and non-retarded low-scorers differed significantly on post partum sub-scores only. When the eight-year follow-up groups were compared both retarded and non-retarded true positives differed significantly from true negatives on total mean reduced optimality. The difference in post-partum reduced optimality between retarded and all other follow-up groups but non-retarded true positives reached statistical significance.(ABSTRACT TRUNCATED AT 250 WORDS)

Child

Optimization of temperature distributions in scanned, focused ultrasound hyperthermia.

Scanned, focused ultrasound systems (SFUS) have considerable flexibility in shaping the power deposition field during hyperthermia treatments. When utilizing this adaptability many complicated, interacting decisions must be made to obtain an optimal steady-state temperature distribution. This optimization problem is studied using a 3-D, radially symmetric simulation program which searches for a set of optimal scan parameters. The conjugate-gradient optimization technique with a golden section search was used to obtain the optimal temperature distributions attainable with a single circular scan of a tumour. The variable scan parameters of the single transducer heating system optimized (and under the control of the therapist) are: transducer tilt and rotation angles, focal depth, output acoustical power, and scan radius. This single scan study includes the effects of tumour and normal tissue blood perfusions, tumour depth, skin temperature boundary condition, as well as tumour size and shape. A similar, but less comprehensive, study was done for larger tumours using two concentric circular scans. The results show that (1) the optimization process can produce a set of scan parameters that give a considerably better temperature distribution than could be obtained ad hoc, and (2) the optimal scan parameter configuration obtained produces a close-to-ideal tumour temperature distribution for a wide variety of clinically relevant conditions. Thus, when extended to include data from individual patients such optimization should be a very useful tool in patient treatment planning, and should enhance the present capabilities of clinical scanned, focused ultrasound systems.

Body Temperature

A model of optimal voluntary muscular control.

In the absence of detailed knowledge of how the CNS controls a muscle through its motor fibers, a reasonable hypothesis is that of optimal control. This hypothesis is studied using a simplified mathematical model of a single muscle, based on A.V. Hill's equations, with series elastic element omitted, and with the motor signal represented by a single input variable. Two cost functions were used. The first was total energy expended by the muscle (work plus heat). If the load is a constant force, with no inertia, Hill's optimal velocity of shortening results. If the load includes a mass, analysis by optimal control theory shows that the motor signal to the muscle consists of three phases: (1) maximal stimulation to accelerate the mass to the optimal velocity as quickly as possible, (2) an intermediate level of stimulation to hold the velocity at its optimal value, once reached, and (3) zero stimulation, to permit the mass to slow down, as quickly as possible, to zero velocity at the specified distance shortened. If the latter distance is too small, or the mass too large, the optimal velocity is not reached, and phase (2) is absent. For lengthening, there is no optimal velocity; there are only two phases, zero stimulation followed by maximal stimulation. The second cost function was total time. The optimal control for shortening consists of only phases (1) and (3) above, and is identical to the minimal energy control whenever phase (2) is absent from the latter. Generalization of this model to include viscous loads and a series elastic element are discussed.

Biophysical Phenomena

DESIGN: computerized optimization of experimental design for estimating Kd and Bmax in ligand binding experiments. I. Homologous and heterologous binding to one or two classes of sites.

We have developed a versatile computer program for optimization of ligand binding experiments (e.g., radioreceptor assay system for hormones, drugs, etc.). This optimization algorithm is based on an overall measure of precision of the parameter estimates (D-optimality). The program DESIGN uses an exact mathematical model of the equilibrium ligand binding system with up to two ligands binding to any number of classes of binding sites. The program produces a minimal list of the optimal ligand concentrations for use in the binding experiment. This potentially reduces the time and cost necessary to perform a binding experiment. The program allows comparison of any proposed experimental design with the D-optimal design or with assay protocols in current use. The level of nonspecific binding is regarded as an unknown parameter of the system, along with the affinity constant (Kd) and binding capacity (Bmax). Selected parameters can be fixed at constant values and thereby excluded from the optimization algorithm. Emphasis may be placed on improving the precision of a single parameter or on improving the precision of all the parameters simultaneously. We present optimal designs for several of the more commonly used assay protocols (saturation binding with a single labeled ligand, competition or displacement curve, one or two classes of binding sites), and evaluate the robustness of these designs to changes in parameter values of the underlying models. We also derive the theoretical D-optimal design for the saturation binding experiment with a homogeneous receptor class.

Binding Sites

Optimized dynamic rotation with wedges.

Dynamic rotation is a computer-controlled therapy technique utilizing an automated multileaf collimator in which the radiation beam shape changes dynamically as the treatment machine rotates about the patient so that at each instant the beam shape matches the projected shape of the target volume. In simple dynamic rotation, the dose rate remains constant during rotation. For optimized dynamic rotation, the dose rate is varied as a function of gantry angle. Optimum dose rate at each gantry angle is computed by linear programming. Wedges can be included in the optimized dynamic rotation therapy by using additional rotations. Simple and optimized dynamic rotation treatment plans, with and without wedges, for a pancreatic tumor have been compared using optimization cost function values, normal tissue complication probabilities, and positive difference statistic values. For planning purposes, a continuous rotation is approximated by static beams at a number of gantry angles equally spaced about the patient. In theory, the quality of optimized treatment planning solutions should improve as the number of static beams increases. The addition of wedges should further improve dose distributions. For the case studied, no significant improvements were seen for more than 36 beam angles. Open and wedged optimized dynamic rotations were better than simple dynamic rotation, but wedged optimized dynamic rotation showed no definitive improvement over open beam optimized dynamic rotation.

Humans