PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Porosity”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Porosity of porcine small-intestinal submucosa for use as a vascular graft.

The porosity of a vascular graft material has been suggested as a major factor affecting the rate and degree of neovascularization of newly implanted grafts, with higher porosities generally associated with better performance. The objective of this study was to determine the water porosity of a new vascular graft material, small-intestinal submucosa (SIS), and to compare the values to those reported for other common vascular graft materials. In addition, the porosity of SIS was investigated with respect to applied pressure and applied uniaxial tension. Both rectangular, flat specimens and tubular specimens of SIS were subjected to static water pressure, and water was collected as it passed through the SIS material. SIS has a typical porosity of 0.52 mL/min.cm-2 at an applied pressure of 120 mm Hg. Although porosity appeared to be unaffected by uniaxial tension, it increased in proportion to applied pressure at a rate of 4.8 x 10(-3) mL/min.cm-2/mm Hg. These low porosity values and the past success of SIS as a vascular graft material suggest that high-porosity materials are not required for implant success.

Animals↗

Porosity of porcine bladder acellular matrix: impact of ACM thickness.

The objectives of this study are to examine the porosity of bladder acellular matrix (ACM) using deionized (DI) water as the model fluid and dextran as the indicator macromolecule, and to correlate the porosity to the ACM thickness. Porcine urinary bladders from pigs weighing 20-50 kg were sequentially extracted in detergent containing solutions, and to modify the ACM thickness, stretched bladders were acellularized in the same manner. Luminal and abluminal ACM specimens were subjected to fixed static DI water pressure (10 cm); and water passing through the specimens was collected at specific time interval. While for the macromolecule porosity testing, the diffusion rate and direction of 10,000 MW fluoroescein-labeled dextrans across the ACM specimens mounted in Ussing's chambers were measured. Both experiments were repeated on the thin stretched ACM. In both ACM types, the fluid porosity in both directions did not decrease with increased test duration (3 h); in addition, the abluminal surface was more porous to fluid than the luminal surface. On the other hand, when comparing thin to thick ACM, the porosity in either direction was higher in the thick ACM. Macromolecule porosity, as measured by absorbance, was higher for the abluminal thick ACM than the luminal side, but this characteristic was reversed in the thin ACM. Comparing thin to thick ACM, the luminal side in the thin ACM was more porous to dextran than in the thick ACM, but this characteristic was reversed for the abluminal side. The porcine bladder ACM possesses directional porosity and acellularizing stretched urinary bladders may increase structural density and alter fluid and macromolecule porosity.

Animals↗

Prediction of cortical bone porosity in vitro by microcomputed tomography.

The high importance of intracortical porosity for mechanical strength of cortical bone has been established. The contribution of other parameters of microstructure such as osteon dimensions for strength is in discussion. The aim of this study was to evaluate the predictive value of microcomputed tomography (mCT) for porosity and other microstructural parameters of cortical bone in cortical bone biopsies. Femoral cortical bone specimens from the middiaphysis of 24 patients were harvested during the procedure of total hip replacement at the location where normally one hole (Ø 4.5 mm) for the relief of the intramedullary pressure is placed. In vitro intracortical porosity and bone mineral density (BMD) measurements by mCT were compared with structural parameters assessed in histological sections of the same specimens. A strong correlation was found between intracortical porosity measured by mCT and histological porosity (r = 0.95, P <0.0001). Porosity measured by mCT was also a strong predictor for other parameters describing dimensions of porous structures. BMD?1 was associated with osteonal area (r = -0.76, P <0.0001). We consider the measurement of porosity by mCT as a very potent procedure for assessing intracortical porosity and parameters related to porous structures of cortical bone nondestructively in vitro.

Aged↗

Porosity evaluation and pore size distribution of a novel directly placed ceramic restorative material.

OBJECTIVES: The aim of this in vitro study was to compare porosity, i.e. voids or pores due to placement, of a new directly placed ceramic restorative material (DoxaDent, Doxa Certex AB, Uppsala, Sweden) to a glass ionomer (Fuji IX, GC Corporation, Tokyo, Japan), a hybrid composite control (Filtek Z250, 3M ESPE St Paul, MN, USA) and an amalgam control (Tytin, Kerr Orange, CA, USA). Pore distribution and size were determined for each material tested. METHODS: Standardized MOD preparations (one operator) on 20 extracted human molars had gingival margins located above and below the CEJ. Restored teeth (5 teeth/material) were sectioned in mesio-distal directions (two sections/tooth; n=10/group). Sections were polished through 1 microm Al2O3 abrasive. Porosity levels and size distributions were measured using SEM. Effects of different gingival extensions of inter-proximal boxes on porosity levels and distributions were investigated (mesial, occlusal, and distal regions). RESULTS: No MOD region was free of pores. Porosity in mesial, occlusal and distal boxes, respectively, for each restorative material were (vol%): Tytin: 1.3(0.9), 2.9(2.1), and 2.9(1.4); Filtek Z250: 2.6(1.0), 2.9(1.0), and 2.6(0.8); Fuji IX: 8.8(1.9), 7.9(1.7), and 7.7(1.8); Doxadent: 13.0(1.8), 12.4(1.7), and 11.5(1.4). Overall porosity ranged from 2.4(0.9)% for Kerr Tytin, 2.7(0.7)% for Filtek Z250, 8.0(1.1)% for GC Fuji IX, and 12.3(1.1)% for Doxadent. There was no difference between Z250 composite and Tytin amalgam, but differences existed between them with Fuji IX and Doxadent. No statistically significant difference (p>0.05) in porosity occurred among different restoration regions (mesial, distal and occlusal box) for any material. Total porosity levels for different measurement methods (point counting versus direct counting) were remarkable consistent (p>0.05). SIGNIFICANCE: Based on results of this limited study, the new directly placed ceramic restorative material (Doxadent) contains significantly (p<0.05) higher bulk porosity levels than both amalgam and composite. This may explain the lower than expected mechanical property values reported in other studies.

Aluminum Compounds↗

Modeling porosity reductions caused by mineral fouling in continuous-wall permeable reactive barriers.

A study was conducted to assess key factors to include when modeling porosity reductions caused by mineral fouling in permeable reactive barriers (PRBs) containing granular zero valent iron. The public domain codes MODFLOW and RT3D were used and a geochemical algorithm was developed for RT3D to simulate geochemical reactions occurring in PRBs. Results of simulations conducted with the model show that the largest porosity reductions occur between the entrance and mid-plane of the PRB as a result of precipitation of carbonate minerals and that smaller porosity reductions occur between the mid-plane and exit face due to precipitation of ferrous hydroxide. These findings are consistent with field and laboratory observations, as well as modeling predictions made by others. Parametric studies were conducted to identify the most important variables to include in a model evaluating porosity reduction. These studies showed that three minerals (CaCO3, FeCO3, and Fe(OH)2 (am)) account for more than 99% of the porosity reductions that were predicted. The porosity reduction is sensitive to influent concentrations of HCO3-, Ca2+, CO3(2-), and dissolved oxygen, the anaerobic iron corrosion rate, and the rates of CaCO3 and FeCO3 formation. The predictions also show that porosity reductions in PRBs can be spatially variable and mineral forming ions penetrate deeper into the PRB as a result of flow heterogeneities, which reflects the balance between the rate of mass transport and geochemical reaction rates. Level of aquifer heterogeneity and the contrast in hydraulic conductivity between the aquifer and PRB are the most important hydraulic variables affecting porosity reduction. Spatial continuity of aquifer hydraulic conductivity is less significant.

Chemical Precipitation↗

Sintering of dental porcelain: effect of time and temperature on appearance and porosity.

OBJECTIVE: Mechanical condensation of powder-method dental porcelains can only achieve a limited effect--the majority of consolidation and porosity elimination is achieved by sintering. However, there is a surprising lack of information on the process in the literature, and the effects of the two basic conditions of sintering, time and temperature, are very poorly described despite theoretical expectations. The present study was to investigate the effects of these conditions on porosity and to consider its relationship to the recognizable firing stages of low and high biscuit, and other aspects of appearance, with a view to schedule recommendations. METHODS: The variation of appearance, pore form and percentage porosity with sintering time and temperature was studied for five dental dentine porcelains, two aluminous: Alpha (Vita Zahnfabrik, Bad Säckingen, Germany) and Vitadur-N (Vita); and three feldspathic: Omega (Vita), VMK68 (Vita) and Carmen (Esprident, Ispringen, Germany). Disc specimens were sintered for 0-1000 min over 750-1100 degrees C in a systematic search pattern to establish limits of acceptable appearance (high biscuit to not quite slumped). Porosity was measured using an image analyser on specimens fired for sintering times of 24 and 30 s; 1, 3, 6 and 30 min; 1, 5, 10, 15 and 20 h; with sintering temperatures from 750 to 950 degrees C for Carmen and 800-1050 degrees C for the others, all with 50 degrees C increments. Measurements were made on a ground and polished surface (1 microm diamond), five fields on each of five specimens per condition. The percentage porosity, pore count, median pore area and pore size distribution were analyzed. RESULTS: The boundaries of the acceptable appearance areas in maps of sintering temperature vs. sintering time were clearly delineated; analysis showed that they may be related to the activation energy of the diffusive processes occurring during sintering. Minimum porosity was obtained at high temperature and short time, close to but not consistently coincident with the manufacturers' recommendations. There is also a conductivity-related minimum sintering time at high temperatures. The theoretical reduction on prolonging sintering at high temperature was not a general result, and porosity increased markedly in the feldspathic porcelains, particularly VMK-68. SIGNIFICANCE: The reduction of porosity of dentine porcelain is much more sensitive to temperature than to time. It is possible systematically to identify optimum conditions using the present approach. Detailed study of the effects of formulation on the sintering process may be made by reference to the activation energy.

Algorithms↗

Effect of formulation and process variables on porosity parameters and release rates from a multi unit erosion matrix of a poorly soluble drug.

The effect of drug loading, water required for granulation and spheronization time on porosity parameters (intrusion-extrusion isotherms, pore size distribution, total pore surface area, mean pore diameter, shape and morphology of pores) and drug release rates from pellets of a poorly soluble drug was investigated. Porosity parameters were determined by mercury intrusion porosimetry. The drug loading was found to have a profound effect on the porosity parameters. Pellets with low drug loading showed increased pore surface area with small mean pore diameters and an increased number of total pores. On the other hand, pellets with high drug loading had decreased pore surface areas with larger mean pore diameters and a reduction in the total number of pores. With high drug loading, the drug release rate decreased. Water required for granulation had a direct effect on the total porosity of the pellets. Spheronization time from 2 to 10 min had a pronounced effect on porosity parameters and release rates. No changes in porosity parameters and release rates were observed from 10 to 20 min of spheronization time. It was shown that each porosity parameter investigated was well correlated with drug release rates and thus it is important to study the effect of porosity parameters in evaluating the in vitro performance of the multi-unit erosion matrix for the controlled release of a poorly soluble drug.

Chemistry, Pharmaceutical↗

Regional differences in cortical porosity in the fractured femoral neck.

Although bone mass is a contributory risk factor for intracapsular hip fracture, its distribution and porosity within the femoral neck is also important for bone strength. In femoral neck biopsies from 13 women with intracapsular hip fracture (mean +/- SEM: 75.4+/-2.1 years, OP) and 19 cadaveric samples (9 men and 10 women [control], aged 79.4+/-1.7 years), a segmental analysis was used to quantify circumferential variations in the characteristics of cortical bone haversian systems. In female control femoral necks, there was an increasing porosity gradient between the inferior (I) (7.7+/-0.6%) and superior regions (S) (16.05+/-1.8%,p < 0.005). In walking, these regions undergo compression and tension, respectively. In men, a similar trend was observed, but the differences were not significant (I: 11.1+/-1.2%; S: 14.1+/-1.7%; p = 0.133). This porosity gradient was not maintained in the fracture group (I: 10+/-1%; S: 12.65+/-1.2%). In contrast, porosity in the fracture group was greatest in the anterior cortex, being 41% higher in that quadrant than in controls (p = 0.06). The areal density of haversian canals ranged from 16.7 to 21.3 canals/mm2 with no significant differences between fractures and controls. In the control women, mean canal diameter was highest in the superior region (60+/-2.8 microm), and these canals were significantly larger than those in the inferior region (49.4+/-1.4 microm, p < 0.05). This difference was less marked in the fracture cases (I: 53.21+/-2.5 microm; S: 59.1+/-2.8 microm; p = 0.0878). Although the mean canal diameter in the anterior quadrant of the fracture cases was higher than in the control women this did not reach significance (OP/F: 59.5+/-3 microm; control/F: 52.7+/-2.6 microm; p = 0.106). However, the proportion of "giant" canals with diameters >385 microm (defined as the top 0.5% in the controls) was doubled in the anterior region of the fracture cases (OP/F: 1.28%; control/F: 0.69%; p < 0.005). Porosity is related to the square of the canal radius; therefore, such canals make a substantial contribution to cortical porosity. Previous work has shown that the elastic modulus of bone decreases approximately as the square root of porosity. Therefore, the increased porosity and the higher prevalence of "giant" canals have a markedly negative influence on the ability of the cortical shell to withstand stresses associated with a fall. The mechanisms responsible for the localized generation of "giant" haversian canals, and ultimately the "trabecularization" of the cortex, require further investigation.

Adaptation, Physiological↗

General rules for the optimal external porosity of LC supports.

We present a series of numerically calculated plate height and flow resistance data obtained for an idealized chromatographic support mimic with variable bed porosity (0.3 </= epsilon </= 0.9), yielding a unique insight into how the main chromatographic performance parameters can be expected to vary with the external bed porosity, unbiased by any differences in molecular diffusivity or retention factor. The influence of pore heterogeneity effects is considered as well. It is found that the product h(min)nu(opt) depends only very weakly on epsilon and on the degree of pore heterogeneity. It is also found that the minimal separation impedance E(min) decreases monotonically with epsilon. This shows that the minimal plate height increase that can be expected for large porosity systems is always more than compensated by their reduced flow resistance, in agreement with the current observations in real silica monolith columns. Using the computed plate height data in an optimization analysis, it is found that large porosity supports can always potentially yield shorter analysis times or larger plate numbers than small porosity supports but need submicrometer feature sizes to actually achieve this. Assuming a lower limit on the producible or useable structural feature sizes, it is found that small N separations can best be performed with a small porosity packing, whereas large N separations require a large porosity packing if the column length (L) is left free. A plot yielding epsilon(opt) as a function of the required plate number has been established, showing that roughly epsilon(opt) approximately log(N) in both the ordered and the disordered support cases. It is also shown that the maximal increase in peak capacity ever to be expected from the use of high porosity supports is a factor of 2 (if the mobile-phase viscosity can be kept constant), potentially to be increased by a factor of 1.5 by increasing the homogeneity of the packing.

Journal Article↗

Porosity effects on electron transport in TiO2 films and its application to dye-sensitized solar cells.

Porosity (P) of TiO2 film in dye-sensitized solar cells affects the light absorption coefficient and electron diffusion coefficient. A theoretical analytical expression of the intensity-modulated photocurrent spectroscopy (IMPS) response involving the light absorption coefficient and the electron diffusion coefficient as a function of the porosity has been proposed to investigate the influence of TiO2 film porosity on the characteristics of electron transport. The incident photon-to-current conversion efficiency (IPCE) and electron transit time depending on the porosity have been analyzed illuminating from both the electrolyte side (IE) and the substrate side (IS). The IPCE derived from the IMPS response reaches its maximum at a porosity of around 30% for IE and 41% for IS, respectively. Electron transit time increases with increasing the porosity for IE, while it declines when P < 0.41 for IS, which is attributable to the influence of the RC time constant. It has also been found that a larger RC time constant will lead to a longer transit time. The electron diffusion coefficient calculated from the transit time for IE corresponds to the results from the porosity reported in previous literature, which indicates that the dependence of the electron transit time tau(d) on the porosity is justifiable. The diffusion coefficient calculated for a larger RC time constant approaches the value from the literature when P > or = 0.41, while it is not practicable when P < 0.41 for IS.

Journal Article↗

[Relationship between mechanical properties and amounts of casting porosities in tensile-test fracture surface of Au-Pd-Ag-Cu alloy (author's transl)].

One hundred and thirty-nine tensile-test specimens of Au-Pd-Ag-Cu alloy were cast in various casting conditions. The specimens were subjected age-hardening heat-treatment. The casting porosities and the nonmetallic inclusions in the surface of a tensile-test fracture of cast specimens were observed and analyzed by use of Electron Probe X-ray Microanalyzer (EPMA). The polosity ratio that is the area ratio of the porosities to the fracture surface was determined. Studies were quantitatively made on the effect of the porosity ratio on the tensile strength and the elongation. Furthermore, the effect of the casting conditions on the tensile strength was investigated. The main results were summarized as follows; The tensile strength decreased only slightly within about 15% of the porosity ratio and remarkably with an increase in its ratio in the range from about 15% to 50%. The elongation, however, decreased considerably in the presence of the porosities of only a few per cent. Aspects of the decrease curves on the tensile strength and the elongation were represented in the shape of an inverse S-type and hyperbolic curve with an increase in the porosity ratio, respectively. With an increase in the porosity ratio, the shapes of the tensile-test specimens at the fracture part and load-elongation curves in the tensile-tests were shown as a brittle fracture. However, the result observed by a scanning electron microscope revealed that the fracture surfaces without the porosities showed mostly "dimple pattern" suggesting a characteristic figure of a ductile fracture. The nonmetallic inclusions in the fracture surfaces were identified as SiO2 (quartz) which was derived from an ingredient of an investment by comparing the inclusion with the reference standards on the characteristic X-ray O Kalpha spectra by EPMA. The microstructures observed by a light microscope showed a coarse structure with the high temperature casting conditions. However, the results of a scanning electronmicroscopy revealed that the microstructres observed in high magnifications of about 1000 to 3000 composed of two structures; micro-lamella and Widmanstätten structure, and no difference was shown in the various casting conditions. Therefore, it is concluded in the present alloy that a coarseness of the microstructures observed by a light microscope become no reason for a decrease of the tensile strength.

Copper↗

Estimation of ideal mechanical strength and critical porosity of calcium phosphate cement.

The ideal mechanical strength and critical porosity of calcium phosphate cement (CPC) were estimated to help determine ways to improve its properties. CPC at various porosities was made by packing CPC paste, at various powder-to-liquid (P/L) ratios (2.0-6.0), into a mold under various pressures (0-173 MPa). The mechanical strength of CPC, in terms of diametral tensile strength (DTS), increased with decreases in porosity. Intercrystalline fracture was observed in specimens made without the application of pressure, while fracture within the crystals increased with the packing pressure. These observations support the application of the relationship between DTS and porosity in fractographic equations. The ideal wet DTS and critical porosity of CPC were estimated to be 102 MPa and 63%, respectively. The minimum porosity of the currently used CPC was approximately 26-28%, even when it was packed under 173 MPa, and the maximum DTS value was thus approximately 13-14 MPa. Because reducing the porosity of currently used CPC would be difficult, we conclude that in CPC-related research, we should focus on ways in which to accelerate bone-replacing behavior, in addition to improving the mechanical strength of CPC.

Bone Cements↗

A computational study of the porosity effects in silica monolithic columns.

We report on a theoretical study of the influence of the through-pore porosity on the main chromatographic performance parameters (reduced theoretical plate height, flow resistance, and separation impedance) of silica monoliths. To investigate this problem devoid of any structural uncertainties, computer-generated structural mimics of the pore geometry of silica monolithic columns have been studied. The band broadening in these synthetic monoliths was determined using a commercial Computational Fluid Dynamics (CFD) software package. Three widely differing external porosities (epsilon = 0.38, epsilon = 0.60, and epsilon = 0.86) are considered and are compared on the basis of an identical intra-skeleton diffusivity (Ds = 5 x 10(-10)m2/s), internal porosity (epsilon(int) = 0.5), and for the same phase retention factor (k' = 1.25). Since the data are obtained for perfectly ordered structures, the calculated plate heights and separation impedances constitute the ultimate performance ever to be expected from a monolithic column. It is found that, if silica monoliths could be made perfectly homogeneous, domain size-based reduced plate heights as small as h(min) approximately 0.8 (roughly independent of the porosity) and separation impedances as small as Emin approximately 130 (epsilon = 0.60) and Emin approximately 40 (epsilon = 0.86) should be achievable with pure water as the working fluid. The data also show that, although the domain size is a much better reduction basis than the skeleton size, the former is still not capable of bringing the van Deemter curves of different porosity columns into perfect agreement in the C term dominated velocity range. It is found that, in this range, large porosity monoliths can be expected to yield smaller domain size-based reduced plate heights than small porosity monoliths.

Chromatography↗

The glucanase-soluble mannoproteins limit cell wall porosity in Saccharomyces cerevisiae.

The cell wall porosity of batch-grown Saccharomyces cerevisiae was maximal in the early exponential phase and fell off rapidly to lower levels in later growth phases. Treatment of stationary-phase cells with alpha-mannosidase restored wall porosity to the level of cells in early exponential phase. When cells in the early exponential phase were treated with alpha-mannosidase, or tunicamycin, an inhibitor of N-glycosylation, even higher porosities were obtained. Mutants with truncated mannan side-chains in their wall proteins also had very porous walls. The importance of the mannan side-chains for wall porosity was also seen during sexual induction. Treatment with alpha pheromone, which leads to the formation of wall proteins with shorter mannan side-chains, enhanced wall porosity. Disulphide bridges also affect cell wall porosity. They were predominantly found in the glucanase-soluble wall proteins. Because the main part of the mannan side-chains is also found in this family of wall proteins, our results demonstrate that the glucanase-soluble mannoproteins limit cell wall porosity in yeast.

Benzenesulfonates↗

Assessment of a three-dimensional measurement technique for the porosity evaluation of PMMA bone cement.

In vitro testing of bone cement has historically resulted in the belief that porosity should be minimised to help reduce the risk of prosthesis failure through aseptic loosening. Traditional porosity measurement techniques rely on the analysis of a two dimensional representation of a three dimensional structure. However, with an increasing interest in the number, size and distribution of pores in bone cement, the reliability of a two dimensional approach is questionable. The purpose of this study was to investigate the use of micro computed tomography (micro-CT) for the three dimensional measurement of bone cement porosity by comparison with two traditional techniques. Eighteen bone cement specimens were analysed for porosity using each technique. Levels of agreement between techniques were evaluated, and technique precision was assessed in terms of repeatability and sensitivity to changes in threshold. Micro-CT data was used to illustrate the effectiveness of predicting the porosity of a whole structure from a sample region; an approach often used with traditional techniques. In summary, poor agreement was found between all techniques. However, micro-CT was found to be significantly more repeatable and less sensitive to changes in threshold. The results demonstrated that porosity cannot be reliably determined using traditional techniques and that a large proportion of a specimen is required to provide an accurate porosity measurement.

Biocompatible Materials↗

The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity.

The objective of this study was to examine the dependence of the elastic properties of cortical bone as a transversely isotropic material on its porosity. The longitudinal Young's modulus, transverse Young's modulus, longitudinal shear modulus, transverse shear modulus, and longitudinal Poisson's ratio of cortical bone were determined from eighteen groups of longitudinal and transverse specimens using tensile and torsional tests on a servo-hydraulic material testing system. These cylindrical waisted specimens of cortical bone were harvested from the middle diaphysis of three pairs of human femora. The porosity of these specimens was assessed by means of histology. Our study demonstrated that the longitudinal Young's and shear moduli of human femoral cortical bone were significantly (p<0.01) negatively correlated with the porosity of cortical bone. Conversely, the elastic properties in the transverse direction did not have statistically significant correlations with the porosity of cortical bone. As a result, the transverse elastic properties of cortical bone were less sensitive to changes in porosity than those in the longitudinal direction. Additionally, the anisotropic ratios of cortical bone elasticity were found to be significantly (p<0.01) negatively correlated with its porosity, indicating that cortical bone tended to become more isotropic when its porosity increased. These results may help a number of researchers develop more accurate micromechanics models of cortical bone.

Adult↗

Effects of carbonation and leaching on porosity in cement-bound waste.

Porosity is possibly an important parameter with respect to leaching of constituents from cement monoliths. During its lifetime, the pore structure of cementitious matrices changes due to carbonation and leaching. This paper discusses the effects of both accelerated carbonation and continuous leaching on the porosity, and, conversely, how porosity affects leaching properties. Two sample types are investigated: a mortar with MSWI-bottom ash substituting the sand fraction and a cement paste with 30 wt% of the cement substituted by a flue gas cleaning residue. The samples have been intensively carbonated in a 20% CO(2) atmosphere for up to 60 days and were subsequently leached. The porosity was investigated by mercury intrusion porosimetry. Accelerated carbonation decreases total porosity by 12% in the case of 60 days of treatment of bottom ash mortars, whereas continuous leaching during 225 days increases it by 16%. Both carbonation and leaching decrease the amount of smaller capillary pores. Carbonation decreases both porosity and pH. Decreasing porosity diminishes leaching of sodium and potassium, while the decrease in pH increases leaching. However, the former process dominates the latter, resulting in a net decreasing effect of carbonation on the release of sodium and potassium from these cement matrices.

Carbon Dioxide↗

Influence of metal surface finishing on porcelain porosity and beam failure loads at the metal-ceramic interface.

STATEMENT OF THE PROBLEM: Investigators suggest that metals should be finished in 1 direction before porcelain application to minimize metal irregularities and trapped contaminants. These irregularities are thought to be focal points for porosity and crack propagation. PURPOSE: This study investigated the influence of metal finishing and sandblasting on (1) porosity production at the porcelain-metal interface, and (2) porcelain-metal beam failure load. MATERIAL AND METHODS: Eighty cast metal samples were divided into 4 test groups: (A) bidirectional finish/sandblasting; (B) unidirectional finish/sandblasting (C) bidirectional finish only; and (D) unidirectional finish only. The porcelain applied was 1.5 mm thick. Samples were sectioned longitudinally. Half of the samples were subjected to a 3-point flexural test. The remaining samples were sectioned into 4 slices and were examined with a light microscope (x500). Number and diameter of porosities at the metal-porcelain interface were recorded. RESULTS: Mean loads at failure (lbs) were as follows: A, 11.1 +/- 1.3 (5.03 +/- 0.58 Kg); B, 11.2 +/- 1.7 (5. 08 +/- 0.77 Kg); C, 4.0 +/- 1.8 (1.81 +/- 0.81 Kg); and D, 5.0 +/- 2. 1 (2.26 +/- 0.95 Kg). Groups A and B were significantly different from groups C and D (P<.0001). Nonsandblasted samples (C and D) exhibited a separation at the ceramometal interface, which prevented quantification of porosity size and number. Average interface porosity sizes (microm) (A, 8.99 +/- 1.92; B, 10.03 +/- 1.86) showed no significant difference. The mean interface porosity number (A, 62. 3 +/- 16.02; B, 67.4 +/- 10.01) showed no significant difference. CONCLUSION: Direction of metal finishing did not affect the porosity number and size at the ceramometal interface or the beam failure loads. Sandblasting increased the beam failure loads. Nonsandblasted samples showed detachment of the porcelain from the metal.

Aluminum Oxide↗