PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pupil dynamics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

[Artifact detection and signal reconstruction in the pupillogram].

Just as the EEG reflects different wake and sleep stages, changes in pupil dynamics reflecting different levels of vigilance are also to be found. The literature contains numerous reports on experimental set-ups for the recording of the pupillogram. Interesting methods of signal processing are to be found in [7] and [5]. Currently, such recordings are being used to check the success of sleep therapy. A problem that still needs solving is the optimal handling of artifacts caused by blinking. The present article proposes a procedure for artifact detection by back-propagation networks, and subsequent reconstruction of the signal by an AR model. Estimation of the signal is first demonstrated by a test signal, and then by a corrupted pupillogram.

Arousal↗

A solid-state instrument for measuring dynamic changes in the pupil of the human eye.

An instrument for making dynamic measurements of the human pupil is described. The device uses a 100-element linear self-scanning photodiode array and a Z80A microprocessor system. The eye is imaged using infrared radiation. The instrument has both analogue and digital outputs of pupil diameter, which are accurate to better than +/- 2.5% of full scale. By compensating for the inherent nonuniformities in the photodiode array, the microcomputer maintains the accuracy and reliability of the system at low irradiance levels. A simple means of implementing a two-dimensional measuring system is proposed.

Biomedical Engineering↗

The oval pupil.

The dynamics of pupillary dilation induced by Phenylephrine 10% and Cyclopentolate 1% have been examined by flash photography. A correlation between anterior chamber depth and the pupil shape on dilation with Phenylephrine Hydrochloride 10% is described. It is postulated that these pupillary dilation dynamics support a sympathetic abnormality as a trigger for acute primary angle closure glaucoma.

Adolescent↗

Dynamic measurement of accommodation and pupil size using the portable Grand Seiko FR-5000 autorefractor.

PURPOSE: The purpose of this study was to evaluate the potential of the portable Grand Seiko FR-5000 autorefractor to allow objective, continuous, open-field measurement of accommodation and pupil size for the investigation of the visual response to real-world environments and changes in the optical components of the eye. METHODS: The FR-5000 projects a pair of infrared horizontal and vertical lines on either side of fixation, analyzing the separation of the bars in the reflected image. The measurement bars were turned on permanently and the video output of the FR-5000 fed into a PC for real-time analysis. The calibration between infrared bar separation and the refractive error was assessed over a range of 10.0 D with a model eye. Tolerance to longitudinal instrument head shift was investigated over a +/-15 mm range and to eye alignment away from the visual axis over eccentricities up to 25.0 degrees . The minimum pupil size for measurement was determined with a model eye. RESULTS: The separation of the measurement bars changed linearly (r2 = 0.99), allowing continuous online analysis of the refractive state at 60 Hz temporal and approximately 0.01 D system resolution with pupils >2 mm. The pupil edge could be analyzed on the diagonal axes at the same rate with a system resolution of approximately 0.05 mm. The measurement of accommodation and pupil size were affected by eccentricity of viewing and instrument focusing inaccuracies. CONCLUSIONS: The small size of the instrument together with its resolution and temporal properties and ability to measure through a 2 mm pupil make it useful for the measurement of dynamic accommodation and pupil responses in confined environments, although good eye alignment is important.

Accommodation, Ocular↗

Estimation of autonomic nervous activity using the inverse dynamic model of the pupil muscle plant.

In order to elucidate the mechanism of the pupillary control system, the internal property of the pupillary muscle plant, as well as the autonomic nervous input to the muscle plant, must be analyzed. In this study, we approach the problem first by constructing a new homeomorphic biomechanical model for the human pupillary muscle plant (forward dynamic model). We showed that the model is able not only to reproduce various experimental results that exhibit various nonlinearities but also to explain how such nonlinear responses are generated in terms of the internal property of the model. Then, we contrive a possible method to estimate the autonomic nervous input to the muscle plant. This method utilizes the inverse dynamic model of the pupillary muscle plant so that the autonomic nervous input can be estimated from the pupillary response. We applied this method to the experimental step responses, and showed that the estimated neural input indicates characteristics quite similar to the results of the physiological experiment. Last, we discuss the origin of the pupillary escape and capture as well as the sustained and transient components of the pupillary response, based on the analysis of the forward and/or inverse dynamic model.

Autonomic Nervous System↗

The effect of pupil size on static and dynamic measurements of accommodation using an infra-red optometer.

The study examines to what degree the output of the Canon Auto-ref R1 infra-red (IR) optometer is affected by variations in pupil size for both static measurement of refractive error and for continuous recording of accommodation when switched to its modified mode of operation. In the normal static mode of operation the measurement of refractive state simply depends on the position of the peak photodetector output for each of three meridians: it does not depend on signal amplitude and hence pupil size. However, in continuous mode the actual output of a single photodiode is measured and the measurement is susceptible to changes in pupil size that occur within the area of the exit pupil utilized by the instrument. Using static and dynamic recording on model and human eyes the study shows that a 10% reduction in output signal relative to the maximum output level (for a constant stimulus) occurs for pupil sizes of 3.9 mm. The relatively small exit pupil has important advantages with regard to the use of mydriatic drugs and task-induced changes in pupil diameter.

Accommodation, Ocular↗

Age related changes in the characteristics of the near pupil response.

Static and dynamic aspects of the near pupil response were studied in human subjects in the age range when accommodative amplitude steadily declines. Dynamic accommodative and pupillary responses to step stimuli were recorded in 66 subjects (ages: 14-45 years). Exponential fits to data provided amplitude, peak velocity and time constants. Accommodative amplitude decreased linearly with age (p < 0.05). Pupil constriction per diopter of accommodative response increased exponentially with age (p < 0.05). The amplitude of pupil constriction for a 2D stimulus decreased linearly with age (p < 0.05) and for a 5D stimulus did not change with age (p = 0.90). The latency of pupil constriction did not change with age (p = 0.65), while the mean peak velocity decreased linearly with age (p < 0.05). An increase in the amount of pupil constriction per diopter of accommodative response, but not per diopter of stimulus amplitude, suggests that the near effort per se does not increase with age. There is a slight reduction in the speed of near pupil response with age.

Accommodation, Ocular↗

Pupil responsiveness in cluster headache: a dynamic TV pupillometric evaluation.

In this study the variations in pupil diameter induced by different stimuli (dark-light adaptation, light reflex, electric stimulation of the sural nerve) were investigated in episodic (in the active or remission phases) and in chronic cluster headache (CH) patients. Pupil size monitoring was performed with a monocular, infrared TV pupillometer, and sural nerve stimuli were applied after the pain threshold had been measured as the flexion reflex threshold of the biceps femoris muscle (RIII reflex). The results were compared with those obtained in patients with "peripheral" (third neuron) Horner's syndrome and in healthy sex- and age-matched controls. On the symptomatic side we found an impairment of pupil response to light flashes and nociceptive stimuli; similar findings were sometimes evident on the pain-free side, too. These results substantiate previous observations that in cluster headache a dysfunction of the integrative central nervous system pathways also exists intercritically and mostly bilaterally, involving both autonomic regulation and pain perception mechanisms.

Adult↗

Characteristics of the pupillary light reflex in the alert rhesus monkey.

This study investigated the static and dynamic characteristics of the pupillary light reflex (PLR) in the alert rhesus monkey. Temporal characteristics of the PLR were investigated with Maxwellian viewing during sinusoidal changes in illumination of a 36 degrees stimulus in both monkeys and humans. Bode plots of the PLR response were fitted by a linear model composed of a delay combined with a cascaded first- and second-order filter. The Bode magnitude plots conformed to this model with a sharp roll-off above 1.3 Hz for the human PLR and 1.9 Hz for the monkey PLR. Bode phase angle plots were fitted by this model with a delay of 280 ms for humans and 160 ms for monkeys. To investigate the influence of the sympathetic innervation of the iris on steady-state pupil diameter, dynamics of pupillary responses, and the latency of the PLR, we blocked this innervation pharmacologically with a selective alpha-1 adrenoreceptor antagonist. Although there was a resultant miosis (decrease in pupil diameter) from the relaxation of the pupil dilator muscle, no other measures of the PLR, including the dynamics and latency, were significantly affected by this treatment. We examined the pupillary responses evoked by visual stimuli presented either binocularly or monocularly at various locations on a 80 x 60 degrees tangent screen. These pupillomotor fields revealed that, as has been reported for humans, stimuli at the fovea and surrounding macular region of monkeys produce substantially larger pupillary responses than more peripheral stimuli and that binocular responses are substantially greater than can be accounted for by the linear summation of binocular retinal illuminance. In conclusion, we found that the spatial characteristics of the PLR of the rhesus monkey are very similar, in all important aspects, to those reported for humans and that the temporal responses of the PLR are comparable between the two species. The rhesus monkey thus provides an excellent model for experimental studies of the neural control of the pupil.

Adrenergic Antagonists↗

Dynamic visual stimulus presentation in an adaptive optics scanning laser ophthalmoscope.

PURPOSE: To demonstrate the technology and application of synchronized laser modulation in the adaptive optics scanning laser ophthalmoscope (AOSLO), which makes it possible to deliver adaptive optics (AO) corrected stimuli to the retina of a living eye and to record the precise retinal location where the stimulus has landed. METHODS: The modification involves the development of custom software to control a high frequency pixel clock and a waveform generator board in synchrony with the scanning mirrors. The experiment involves a measurement of visual acuity with and without aberrations correction with AO. RESULTS: The system can project stimuli at a frame rate of 30 Hz with high sampling resolution (7.5 seconds of arc), thereby limiting the quality of the retinal image to the level of AO correction. Visual acuity in six subjects is improved on average by 33% after aberration correction across a 5.89-mm pupil. CONCLUSIONS: Dynamic visual stimulus presentation in an AOSLO works effectively and expands the scope of AOSLO applications. S5

Adult↗

[Near triad meter--dynamic measurement of pupillometry with horizontal eye tracker by accommodative stimulation].

PURPOSE: A newly developed "Near Triad Meter" is a useful tool to record the dynamics of pupils and horizontal eye movements in both eyes simultaneously with the accommodative stimuli. The responses show insufficiency or strain for accommodation. In this study the objective accommodative power (in diopters, D) is calculated by the measurement of pupillary constriction-ratio(CR) and compared in 4 age groups to find the age-related decrement of diopter values. METHOD: A clearly visible accommodative target was moved back-and-forth from 50 cm to [near point + 1 D] (maximum accommodative stimulus; MAS). The speed was regulated constant for diopter movement. Pupillometry and eye tracker were recorded simultaneously with MAS in both eyes together. Three trials were done on 42 volunteers in each age group from 20-year-olds to 50-year-olds and the most reliable recording was used to measure the CR. Eighteen well-responding volunteers were selected to make the standard curves of CR by step-by-step accommodative stimuli. The mean CRs of initial tests with MAS were applied to the age-matched standard curves to calculate the maximum accommodative diopter value. RESULTS: The mean CRs versus MAS in each age group were 48%/7.2 D in the 20-year group, 46%/6.9 D in the 30-year group, 35%/3.6 D in the 40-year group, and 33%/3.1 D in the 50-year group. The mean values of CR were applied to age-matched standard curves to obtain the maximum accommodative power, which was 8.0 D in the 20-year group, 9.1 D in the 30-year group, 3.4 D in the 40-year group, and 4.1 D in the 50-year group. The 20- and 30-year olds showed equal power statistically, The remarkable age-dependent difference was calculated quantitatively. CONCLUSION: The dynamics of near response revealed the individual summation of accommodative power including depth of focus, and accommodative vergence objectively and quantitatively. This method is useful for understanding the quality of accommodative insufficiency and also the quantity of accommodative width, including presbyopia.

Accommodation, Ocular↗