PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Analysis of organochlorine pesticides using solid-phase microextraction.

A solid-phase microextraction (SPME) procedure has been developed to successfully extract eighteen chlorine-containing pesticides from water. A fused-silica fiber coated with a non-polar polydimethylsiloxane stationary phase was used to extract the analytes from water samples over a concentration range of 0.001 to 100 ng/ml. Limits of detection at a ng/l level were achieved with GC and flame ionization detection, and improved to sub ng/l levels using GC-MS, or GC with electron-capture detection (ECD). The reproducibility of the measurements between fibers was found to be very good, with precision typically below 20% R.S.D. within a single fiber. Qualitative analysis was performed on river and lake samples from Southern Ontario. Samples from the Arctic region of Canada were analyzed quantitatively using a dual ECD system.

Arctic Regions↗

Monitoring the photochemical degradation of triclosan in wastewater by UV light and sunlight using solid-phase microextraction.

Photo solid-phase microextraction (photo-SPME) is applied for the first time to study the photochemical behavior of an emerging pollutant, triclosan, in real contaminated wastewater samples using a solar simulator. In this study, water samples are extracted by SPME and then, the fiber coating is irradiated for a selected time. This on-fiber procedure, so-called photo-SPME, followed by gas chromatography-mass spectrometry makes it possible to study photodegradation kinetics and the generation of byproducts. Several photoproducts were identified in the real samples including the 2,8-dichlorodibenzo-p-dioxin, dichlorophenols and a compound tentatively identified as other DCDD congener or a dichlorohydroxydibenzofuran. Accordingly, it was possible to postulate main photodegradation mechanisms. Photo-SPME demonstrated slower kinetics in wastewater than in spiked ultrapure water probably due to the presence of dissolved organic matter. This technique was extensively compared with conventional aqueous photodegradation showing high similarity. The influence of pH on the triclosan photolysis and on the triclosan-dioxin conversion was also investigated in wastewater. Photodegradation of triclosan and formation of 2,8-DCDD occurred independently of sample pH. This study represents an advance in the use of photo-SPME to understand the photochemical fate of environmental organic pollutants and demonstrates its clear advantages with real samples.

Chromatography, Ion Exchange↗

Profiling flavor compounds of potato crisps during storage using solid-phase microextraction.

Headspace solid-phase microextraction (HS-SPME) was studied as a solvent free alternative method for the extraction and characterisation of volatile compounds in stored potato crisps by capillary gas chromatography coupled with mass detection. Better results were obtained when extraction was carried out at 70 degrees C using a divinylbenzene (DVB)-carboxen (CAR)-polydimethylsiloxane fiber. The fiber was exposed for 20 min (extraction time) to the sample headspace, immediately after an equilibrium time of 5 min (time needed to reach the equilibrium between sample and above headspace). A total of 31 compounds were identified in oxidised potato crisps and resulted mainly from the degradation/rearrangement of lipids and carbohydrates.

Gas Chromatography-Mass Spectrometry↗

Natural sunlight and sun simulator photolysis studies of tetra- to hexa-brominated diphenyl ethers in water using solid-phase microextraction.

Photo-solid-phase microextraction (photo-SPME) is combined for the first time with natural and simulated sunlight to study the photochemical behaviour of environmental concerning tetra- to hexa-brominated diphenyl ethers. The sunlight photodegradation kinetics of five brominated diphenyl ethers (BDE 47, BDE 100, BDE 99, BDE 154 and BDE 153) has been studied. These BDEs are the most abundant congeners in penta-BDE commercial formulations used as flame-retardants and are considered among the most toxic ones. The five studied BDEs were photolytically labile. The detected photodegradation products include more stable lower brominated diphenyl ethers and polybrominated dibenzofurans (PBDFs). The photoformation and decay kinetics of these photoproducts were also monitorized by photo-SPME. Aqueous photodegradation studies have also been carried out. In this case, SPME is only used as the extraction technique. Obtained results in the aqueous photodegradation experiments were compared with those obtained in photo-SPME experiments.

Ethers↗

Trace analysis of ten chlorinated benzenes in water by headspace solid-phase microextraction.

Headspace solid-phase microextraction (SPME), as a simple, solvent-free method, has been applied to the analysis of 10 chlorinated benzenes (CBs) present at trace levels in water samples. An SPME fibre coated with 100-microm thick poly(dimethylsiloxane) was used for extraction. The analytical data exhibited a relative standard deviation (RSD) range of 1.19% (for pentachlorobenzene) to 8.19% (for hexachlorobenzene) for the 10 CBs; the RSD of most compounds was under 6%. The sensitivity of the method was enhanced with agitation and with addition of salt to the sample solutions. With mass spectrometric detection, the limit of detection was below 0.006 microg/l for all 10 CBs after a 30-min sampling time. The linearity range was 0.02-20 microg/l for the compounds studied. Water samples collected from a reservoir, and from the tap in a laboratory were analysed using the optimised conditions.

Chlorobenzenes↗

Evidence for selectivity of absorption of volatile organic compounds by a polydimethylsiloxane solid-phase microextraction fibre.

Solid-phase microextraction using a 30 microns polydimethylsiloxane fibre has been used to sample the volatile organic compounds from standard mixtures and from mixtures produced by the decomposition of organic compounds. This method of sampling has been compared with the direct injection of an aliquot of headspace gas and shows an enrichment factor of approximately 100 over a 1 ml gas injection for organosulphur gases such as dimethyldisulphide. The performance of the fibre has been evaluated with respect to accuracy and precision at several concentrations in representing the composition of multicomponent mixtures. It was found that the presence of a second component in a gas sample reduced the capacity of the fibre to absorb the primary component. The selectivity of the fibre for various volatile compounds with differing functionality was also studied. It was found that the non-polar polydimethylsiloxane fibre preferentially absorbed the non-polar components of a mixture, e.g. nonane and, correspondingly, under reported the more polar components, e.g. ethanol. Hence, the fibre discriminates in favour of non-polar and against polar components in a mixture in comparison with direct analysis of a headspace sample. Thus, quantitation of a component in a multi-component mixture is liable to error from competitive interference from other components. A major advantage of the technique, however, is that it does not absorb, and therefore introduce, water into the analytical system.

Absorption↗

Rapid determination of organotin compounds by headspace solid-phase microextraction.

Headspace solid-phase microextraction (SPME) followed by gas chromatography (GC) coupled to pulsed flame photometric detection have been investigated for the simultaneous speciation analysis of 14 organotin compounds, including methyl-, butyl-, phenyl-, and octyltins compounds. The analytical process (sorption on SPME fibre and thermal desorption in GC injection port) has been optimised using experimental designs. Six operating factors were considered in order to evaluate their influence on the performances of a SPME-based procedure. The evaluation of accuracy, precision and limits of detection (LODs) according to ISO standards and IUPAC recommendations has allowed the method to be validated. The LODs obtained for the 14 studied organotins compounds are widely sub-ng(Sn) l(-1). The precision evaluated using relative standard deviation ranges between 9 and 25% from five determinations of the analytes at 0.25-125 ng(Sn) l(-1) concentrations. The accuracy was studied throughout the analysis of spiked environmental samples. These first results show that headspace SPME appears really as attractive for organotins determination in the environment and the monitoring of their biogeochemical cycle.

Chromatography, Gas↗

Determination of musk compounds in sewage treatment plant sludge samples by solid-phase microextraction.

Headspace solid-phase microextraction, followed by GC-MS analysis is presented as a suitable technique for the determination of musk compounds in sewage treatment plant sludge. Five polycyclic musks (celestolide, phantolide, traseolide, galaxolide and tonalide) and four nitro musks (musk xylene, musk moskene, musk tibetene and musk ketone) were considered in the optimisation of the analytical method. The influence of extraction temperature, fibre coating, agitation, pH and salting out on the efficiency of the extraction along with the extraction kinetics were studied. An extraction temperature of 100 degrees C and sampling the headspace over the stirred sludge sample using polydimethylsiloxane -divinylbenzene as fibre coating lead to effective extraction. The method proposed is very simple and yields high sensitivity, good linearity and repeatability for all the analytes with limits of detection at the sub-ng/g level. The total analysis time, including extraction and GC analysis, was only 40 min, and no manipulation of the sample was required.

Fatty Acids, Monounsaturated↗

Gas chromatographic-mass spectrometric analysis of dichlorobenzene isomers in human blood with headspace solid-phase microextraction.

Headspace solid-phase microextraction (HS-SPME) was utilized for the determination of three dichlorobenzene isomers (DCBs) in human blood. In the headspace at 30 degrees C, DCBs were absorbed for 15 min by a 100-micron polydimethylsiloxane (PDMS) fiber. They were then analyzed by capillary column gas chromatography-mass spectrometry (GC-MS). By setting the initial column oven temperature at 20 degrees C, the three isomers were resolved at the baseline level. p-Xylene-d10 was used as the internal standard (I.S.). For quantitation, the molecular ion at m/z 146 for each isomer and the molecular ion at m/z 116 for I.S. were selected. For day-to-day precision, relative standard deviations in the range 3.2-10.7% were found at blood concentrations of 1.0 and 10 micrograms/ml. Each compound was detectable at a level of at least 0.02 microgram per 1 g of whole blood (by full mass scanning). HS-SPME-GC-MS, when performed at relatively low temperatures, was found to be feasible in toxicological laboratories. Using this method, the plasma levels of one patient who had drunk a pesticide-like material were measured.

Adult↗

[Separation and identification of volatile flavors of Jinhua ham by gas chromatography-mass spectrometry coupled with head space solid phase microextraction].

Head space solid phase microextraction (SPME) technique was employed to extract volatile flavor compounds from the Chinese traditional food, Jinhua ham. Volatile flavor components of Jinhua ham were isolated and identified successfully by capillary gas chromatography-mass spectrometry (GC-MS). A 75 microm carboxen/poly (dimethysiloxane) (CAR-PDMS) fiber was selected to be the optimum fiber among four different fibers. Optimum adsorption time was 40 min at 60 degrees C. Aldehydes, carboxylic acids and acetones were the major flavor compounds of Jinhua ham.

English Abstract↗

On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples.

This paper compares the advantages and disadvantages of two different configurations for the extraction of triazines from water samples: (1) on-fibre solid-phase microextraction (SPME) coupled to conventional liquid chromatography (LC); and (2) in-tube SPME coupled to capillary LC. In-tube SPME has been effected either with a packed column or with an open capillary column. A critical evaluation of the main parameters affecting the performance of each method has been carried out in order to select the most suitable approach according to the requirements of the analysis. In the on-fibre SPME configuration the fibre coating was polydimethylsiloxane (PDMS)-divinylbenzene (DVB). The limits of detection (LODs) obtained with this approach under the optimized extraction and desorption conditions were between 25 and 125 microg/L. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. The in-tube SPME approach with an open capillary column coated with PDMS (30 cm x 0.25 mm I.D., 0.25 microm of thickness coating) connected to the injection valve provided LODs between 0.1 and 0.5 microg/L. In all configurations UV detection at 230 nm was used. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds.

Chromatography, Liquid↗

Development of a solid-phase microextraction method with micellar desorption for the determination of chlorophenols in water samples. Comparison with conventional solid-phase microextraction method.

A novel analytical method is presented for the determination of chlorophenols in water. This method involves pre-concentration by solid-phase microextraction (SPME) and an external desorption using a micellar medium as desorbing agent. Final analysis of the selected chlorophenols compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detection (DAD). Optimum conditions for desorption, using the non-ionic surfactant polyoxyethylene 10 lauryl ether (POLE), such as surfactant concentration and time were studied. A satisfactory reproducibility for the extraction of target compounds, between 6 and 15%, was obtained, and detection limits were in the range of 1.1-5.9ngmL(-1). The developed method is evaluated and compared with the conventional one using organic solvent as a desorbing agent. The method was successfully applied to the determination of chlorophenols in water samples from different origin. This study has demonstrated that solid-phase microextraction with micellar desorption (SPME-MD) can be used as an alternative to conventional SPME method for the extraction of chlorophenols in water samples.

Chlorophenols↗

Determination of alkylphenols and bisphenol-A. A comparative investigation of functional polymer-coated membrane microextraction and solid-phase microextraction techniques.

A functional polymer (hydroxylated polymethacrylate) coated on porous polysulfone hollow fiber membrane (PS-HFM) was used as an adsorbent for the extraction of alkylphenols and bisphenol-A from seawater samples. Analyses of the extracts were performed using gas chromatography-mass spectrometry (GC-MS) after injection-port derivatization using bis(trimethylsilyl)trifluoroacetamide (BSTFA). We term the procedure as polymer-coated hollow fiber microextraction (PC-HFME). Owing to high porosity PS-HFM coated with hydroxylated polymer showed high extraction efficiency. Compared with solid-phase microextraction (SPME), PC-HFME showed good selectivity and sensitivity. Detection limits of alkylphenols and bisphenol-A ranged between 0.07 and 2.34 ng l(-1). The linearity range was from 0.01 to 15 microg l(-1) and the correlation coefficient (r) up to 0.997. The sensitivity and selectivity of the coated HFM could be potentially tuned by changing the characteristics of the coated hydroxylated polymer. The PC-HFME procedure was applied to the detection of alkylphenols and bisphenol-A in the coastal waters of Singapore.

Benzhydryl Compounds↗

Study on a novel circulating cooling solid-phase microextraction method.

A novel solid-phase microextraction (SPME) setup, circulating cooling solid-phase microextraction (CC-SPME), is developed for determining organochlorine pesticides (OCPs) in water. The linearity area of this method is 0.5-120 microg/l, its RSD value is less than 10% and detection limit is in the low ng/l when it is used to detect gamma-hexachlorocyclohexane, which is better than traditional headspace SPME (HS-SPME) and direct immersion SPME (DI-SPME) methods. The influence of factors such as pH, ionic intensity, adsorption time, and adsorption temperature were also investigated, respectively.

Adsorption↗

Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction.

Multiple headspace-solid phase microextraction (MHS-SPME) is a recently developed technique for the quantification of analytes in solid samples that avoids the matrix effect. This method implies several consecutive extractions from the same sample. In this way, the total area corresponding to complete extraction can be directly calculated as the sum of the areas of each individual extraction when the extraction is exhaustive, or through a mathematical equation when it is not exhaustive. In this paper, the quantitative determination of benzene, toluene, ethylbenzene and xylene isomers (BTEX) in a certified soil (RTC-CRM304, LGC Promochem) and in a contaminated soil by multiple HS-SPME coupled to a gas chromatography-flame ionisation detector (GC-FID) is presented. BTEX extraction was carried out using soil suspensions in water at 30 degrees C with a 75 microm carboxen-polydimethylsiloxane (CAR-PDMS) fibre and calibration was carried out using aqueous BTEX solutions at 30 degrees C for 30 min with the same fibre. BTEX concentration was calculated by interpolating the total peak area found for the soils in the calibration graphs obtained from aqueous solutions. The toluene, ethylbenzene, o-xylene and m,p-xylene concentrations obtained were statistically equal to the certified values.

Benzene↗

Determination of odour-causing volatile organic compounds in cork stoppers by multiple headspace solid-phase microextraction.

Multiple headspace solid-phase microextraction (MHS-SPME) coupled with gas chromatography-mass spectrometry has been applied in order to determine 2,4,6-trichloroanisole (2,4,6-TCA), guaiacol, 1-octen-3-ol and 1-octen-3-one in three samples of cork stoppers. These compounds are responsible for cork taint in wine and can modify the organoleptic properties of bottled wine. Variables such as temperature, addition of water, extraction time, and amount of cork were studied. The extractions were performed with a 50/30 microm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre for 45 min at 100 degrees C using 20 mg of cork. For calibration, 50 microL of VOC aqueous solutions were used and the extraction were carried out for 45 min at 75 degrees C. The limits of detection of the method expressed as ng of VOC per g of cork were 0.3 for 2,4,6-TCA, 7.5 for guaiacol, 1.7 for 1-octen-3-one and 1.9 for 1-octen-3-ol. Relative standard deviation of replicate samples was less than 10%. Significant losses of analytes were observed when the samples were ground at room temperature. Finally, a recovery study was performed and the MHS-SPME results were validated using Soxhlet extraction results.

Anisoles↗

Determination of aldehydes in drinking water using pentafluorobenzylhydroxylamine derivatization and solid-phase microextraction.

A headspace solid-phase microextraction (HS-SPME) procedure followed by gas chromatography and electron capture detection (GC-ECD) has been developed for the determination of aldehydes in drinking water samples at microg/l concentrations. A previous derivatization with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was performed due to the high polarity and instability of these ozonation by-products. Several SPME coatings were tested and the divinylbenzene-polydimethylsiloxane (DVB-PDMS) coating in being the most suitable for the determination of these analytes. Experimental SPME parameters such as selection of coating, sample volume, addition of salt, extraction time and temperature of desorption were studied. Analytical parameters such as precision, linearity and detection limits were also determined. HS-SPME was compared to liquid-liquid microextraction (proposed in US Environmental Protection Agency Method 556) by analyzing spiked water samples; a good agreement between results obtained with both techniques was observed. Finally, aldehydes formed at the Barcelona water treatment plant (N.E. Spain) were determined at levels of 0.1-0.5 microg/l. As a conclusion, HS-SPME is a powerful tool for determining ozonation by-products in treated water.

Aldehydes↗

On-site calibration method based on stepwise solid-phase microextraction.

A stepwise solid-phase microextraction (SPME) method was developed for on-site calibration of SPME for volatile organic compounds analysis. In this approach, a 75-microm Carboxen-polydimethylsiloxane coated fibre was loaded with a prior to exposure to samples of interest Extraction time for the target analytes can be controlled independently from that of the standard, and the response factors for the target analytes can be adjusted accordingly. A good reproducibility of the response factors for BTEXs (benzene, toluene, ethylbenzene and xylenes) was obtained with stepwise SPME. Satisfactory results were obtained by using this method for quantitative analysis of BTEXs in the air of a gas station when tetrachloroethylene was used as a standard. The introduction of standard via the stepwise SPME procedure makes SPME more useful in field applications. It can be used to detect leaks, contaminations and losses from loading of a standard onto a fibre to introduction of the fibre to an analytical instrument. However, this method cannot be used for compensation of sample matrix effects.

Benzene↗