PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “TROCAR”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Optical access trocar injuries in urological laparoscopic surgery.

PURPOSE: Inadvertent injuries during trocar and Veress needle placement are a rare but potentially serious complication of laparoscopic surgery. An access alternative is an optical trocar under direct vision. Limited data are available regarding the safety of this technique. We reviewed complications related to optical access trocars during standard transperitoneal urological laparoscopic procedures performed at a single institution. MATERIALS AND METHODS: From 1995 to 2001 the optical access trocar was used as the initial trocar in 1,283 urological laparoscopic procedures. The procedures included simple and radical nephrectomy in 309 cases, donor nephrectomy in 386, partial nephrectomy in 79, pyeloplasty in 173 and various other procedures in 336. Intra-abdominal complications caused by optical access trocar were assessed. RESULTS: The optical trocar was inserted at the umbilicus in 88 patients (7.4%), in the right upper quadrant in 445 (34.7%) and in the left upper quadrant in 750 (58.5%). There were 4 injuries (0.31%) associated with the optical access trocar. Complications occurred on the left side in 3 cases and on the right side in 1, including 1 injury to bowel, 1 mesenteric injury resulting in a retroperitoneal hematoma and 2 injuries to epigastric vessels. Three cases were recognized and repaired immediately but in a case of epigastric vessel injury the expanding abdominal wall hematoma required postoperative repair. CONCLUSIONS: Optical access trocars provide a safe and rapid technique for initial trocar placement. Results of this large series support the finding that few trocar related complications are associated with the optical access trocar.

Adolescent↗

The ultrasonic trocar provides an easy, sharp, bloodless, and repeatable approach to the abdominal cavity.

Reusable trocars have the advantage of being more cost-effective than disposable trocars. However, the reusable trocar does lose its sharpness on insertion with repetitive insertion. Nonreusable trocars are expensive, but the sharpness of the knife facilitates insertion. Nonreusable trocars have a safety shield system designed to decrease abdominal organ injury, though the potential problem of bleeding from the abdominal wall port site has yet to be resolved. We therefore developed a novel ultrasonic vibrating trocar that does not lose its sharpness even with repetitive insertion. This trocar prevents bleeding by means of an ultrasonic cavitation effect. The ultrasonic vibrating trocar has the advantage of ease of insertion, and the force required for new reusable trocar insertion was only 34% of the force required for insertion of commercially available nonreusable trocars. The force required for multiply used conventional reusable ultrasonic vibrating trocar insertion, ie, 900 insertions, was maintained at less than 46% of the force required by the corresponding nonreusable trocars. Bleeding from the abdominal wall was prevented by an ultrasonic cavitation effect.

Abdominal Wall↗

Variables in the spread of tumor cells to trocars and port sites during operative laparoscopy.

BACKGROUND: Port-site recurrences have delayed the uptake of laparoscopic colectomy, but the etiology of these is incompletely understood. These studies were designed to investigate variables such as the size of the tumor inoculum and the volume and pressure of the insufflated gas during operative laparoscopy that might affect the deposition of these cells in relation to trocars and port sites. METHODS: Radiolabeled human colon cancer cells were injected into the peritoneal cavity of pigs. Three trocars were inserted, and the abdomen was insufflated with carbon dioxide. The movement of cells within the abdomen was traced on a gamma camera. After 2 h, the trocars were removed and the port sites excised. Two studies were performed. In the first study, tumor inocula were varied from 1.5 x 10(5) to 120 x 10(5). In the second study, insufflation pressure was varied, with pressures 0, 4, 8 and 12 mmHg were studied. RESULTS: When larger tumor inocula were injected, the contamination of both trocars (p = 0.005, Kendall's rank correlation) and trocar sites (p = 0.04, Kendall's rank correlation) increased. The deposition of cells on a trocar site was linked to contamination of its trocar (p = 0.03, chi-square), but the contamination of trocars did not always result in trocar-site contamination (p = 0.5, chi-square). Increased volumes of gas insufflation caused increased intraabdominal movement of tumour cells (p = 0.01, Kendall's rank correlation), although this did not lead to greater contamination of trocars or port sites (p = 0.82, Kendall's rank correlation). Decreased insufflation pressures resulted in increased contamination of trocars and port sites (p = 0.01, Kendall's rank correlation). CONCLUSIONS: If clinical situations parallel this study, strategies such as increasing insufflation pressure, reducing episodes of desufflation and gas leaks, and using frequent intraabdominal lavage may help to reduce the numbers of viable tumor cells displaced to port sites during laparoscopic surgery for intraabdominal malignancy. This may reduce the rate of port-site metastases.

Abdominal Wall↗

Friction dynamics of trocars.

BACKGROUND: In minimally invasive surgery, force feedback information on tissue manipulation is altered by friction between the instrument and the sealing mechanism of the trocar. It is unknown how the different sealing mechanisms of currently available trocars influence the friction forces. The current study investigated the dynamic changes in friction for various trocars at different instrument velocities. METHODS: The friction characteristics for six common types of trocars were determined. A force sensor was attached to the shaft of a standard 5-mm disposable grasper to measure the forces required to move it through the trocars. Movement velocity and direction of the shaft were controlled by a servomotor. In addition, whether moistening the shaft reduced friction was tested. RESULTS: The friction depended on the type of trocar, the movement velocity, and the movement direction, and varied between 0.25 and 3.0 N. Specifically, trocars with narrow sealing caps (i.e., high normal force onto the shaft) and trocars with thick sealing caps (i.e., large contact area) generate a high amount of friction. Moistening the shaft reduced friction 15% to 45%. For most trocars, large fluctuations in forces occur when the movement starts or when the direction reverses. The magnitude of these fluctuations varied between 0.2 and 2.5 N. CONCLUSIONS: For some trocars, friction can be as great as the forces associated with instrument-tissue interaction. At movement reversals, friction fluctuates due to deformations of the rubber and silicon parts of the sealing mechanism. Such high variance can deteriorate surgical performance during high precision tasks (e.g., tissue manipulation) that typically involve many changes in movement direction. Comparisons of the investigated trocars indicate that the friction magnitude and variance can be reduced easily by changing the properties of the sealing cap or by lubricating the instruments.

Equipment Design↗

Trocar-associated injuries and fatalities: an analysis of 1399 reports to the FDA.

Laparoscopic trocars, medical devices used to gain access into the abdominal cavity, are the most common device named in malpractice injury claims associated with laparoscopic procedures. As part of its ongoing adverse event reporting program, the U.S. Food and Drug Administration (FDA) requires manufacturers and user facilities to file a report whenever a device was or may have been a factor in a death or serious injury. The FDA collects data from these reports in its Manufacturer and User Facility Device Experience (MAUDE) database. This study presents an analysis of fatality and injury data on laparoscopic trocars found in MAUDE reports received from January 1, 1997, through June 30, 2002, including 31 fatal injury cases and 1353 reports on nonfatal injuries. Cholecystectomy was the procedure most frequently associated with both fatal and nonfatal trocar injuries. Most fatalities involved vascular injuries. All fatality reports that identified the trocar design involved either a shielded trocar (which has a retractable shield that covers the trocar blade before and after insertion to help protect abdominal and pelvic organs from inadvertent puncture) or an optical trocar (which allows laparoscopists to view the cutting tip as it penetrates the tissues). Narrative comments cited surgical technique, device problems, and patient characteristics as contributing factors. Among nonfatal injuries, a change in surgical management such as additional surgical procedure--primarily laparotomy--prolonged surgery, or aborted surgery was reported most frequently for vascular and hollow viscus injuries. Many reports did not identify the device model, surgical procedure, or event timing, limiting Food and Drug Administration (FDA) and manufacturer investigations into whether the device contributed to the event. The most common manufacturer conclusions indicated the trocar was not returned, and no conclusions could be drawn about the trocar's contribution to the event. Fatalities occur with procedures in which shielded trocars and optical trocars are used. Further study is needed to evaluate the high proportion of reports associated with laparoscopic cholecystectomy. Laparoscopists should retain for evaluation any devices implicated in patient injuries and should ensure that detailed information on adverse events is provided in adverse event reports to the FDA. The FDA's Manufacturer and User Facility Device Experience (MAUDE) database can be a valuable source for information on adverse outcomes associated with medical devices and, given an understanding of its limitation, provides researchers with a viable adjunct to published literature and litigation surveys for obtaining this information.

Adolescent↗

Comparison of five different abdominal access trocar systems: analysis of insertion force, removal force, and defect size.

Trocar designs have evolved in response to concerns about complication rates and surgical ergonomics. Functional properties of trocar systems that can be objectively measured include insertion force, removal force and the size of the tissue defect. This study will evaluate these properties in 5 common trocar designs. A porcine model was used to evaluate five different trocar systems for insertion force, removal force, and functional and measured tissue defect. Insertion force was lowest for cutting trocars and highest for radially dilating trocars. Removal force was similar for all trocars. Functional and measured tissue defect size was smallest for the hybrid type and radially dilating trocars. An ideal trocar system incorporates a low insertion force, secure retention, and a minimal tissue defect. Of the systems we tested, the hybrid type trocar has similar wound characteristics to the radially dilating trocar with the benefit of reduced insertion force. Further study is required to determine if these properties translate to an actual improvement in patient outcome.

Abdomen↗

VersaStep trocar hernia rate in unclosed fascial defects in bariatric patients.

OBJECTIVE: Use of the VersaStep trocar system (US Surgical, Norwalk, CT) has the perceived advantage of minimal trocar-related hernias in patients undergoing Roux-en-Y gastric bypass surgery (RYGB). We performed a retrospective review of our last 747 consecutive operative procedures using these trocars. METHODS AND PROCEDURES: The patient population was 747 consecutive patients who underwent laparoscopic RYGB at Duke University Health System Weight Loss Surgery Center from January 2002 through April 2005. A total of 3735 radially expanded trocar sites were used. VersaStep trocars were used in all cases. The port configuration included one supraumbilical Hasson port, two 12-mm ports, and three 5-mm ports. The Hasson port was closed with a figure-of-eight number 1 Polysorb suture. All other trocar sites had no fascial closure. Intestinal anastomoses were created with a linear stapler in all of the laparoscopic cases, with hand suturing of the residual enterotomy. The fascial incisions were therefore not extended to accommodate an EEA stapler. The charts were reviewed for occurrence of subsequent trocar site hernias. RESULTS: There were no hernias at any of the VersaStep trocar sites-an incidence of 0%. There were nine incisional hernias at the Hasson port site which later required surgical repair-an incidence of 1.20%. CONCLUSIONS: There were no hernias detected at any of the 1494 12-mm or 2241 5-mm VersaStep trocar sites, despite lack of suture closure. At the Hasson port site, there was a hernia incidence of 1.20%. In the bariatric RYGB population, routine suture closure of the fascia or muscle is not necessary when using radially expanding VersaStep trocars.

Anastomosis, Roux-en-Y↗

A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model.

OBJECTIVE: Our purpose was to compare the relative risk of vessel injury after use of a 5 mm conical-tipped trocar, a 5 mm pyramidal-tipped trocar, and a 10 mm pyramidal-tipped trocar in a rabbit vessel model. STUDY DESIGN: Plastic templates were placed in front of and behind 108 mesenteric vessels in 11 anesthetized New Zealand White rabbits. Laparoscopic trocars were inserted through the templates and mesentery. The incidence of vessel injury was determined at distances from the vessels ranging from 0 to 5 mm. RESULTS: The 5 mm conical trocar resulted in a vessel injury rate of 88% at 0 mm from the vessel but 0% at 1 or 2 mm. The 5 mm pyramidal trocar resulted in 100%, 88%, and 62% injury rates of 0, 1, and 2 mm from the vessels, respectively. The 10 mm pyramidal trocar resulted in a 100% injury rate at 0, 1, 2, or 3 mm from the vessels and 80% and 40% at 4 mm and 5mm, respectively. CONCLUSION: The relative risk of vessel injury is significantly increased by the use of pyramidal-tipped trocars when compared with conical-tipped trocars, especially if larger diameter trocars are used.

Animals↗

Measurement of trocar insertion force using a piezoelectric transducer.

We attempted to establish a model to measure the force required for trocar insertion at laparoscopy. A 3-cm, circular transducer was constructed from piezoresistive material that changes its impedance as force is exerted on its surface. The transducer is connected by an interface box to a personal computer to record surface contact pressure digitally (pressure = force/area) profile continuously during trocar insertion. Each subject had three trocars inserted: a 10-mm trocar at the umbilicus after creation of pneumoperitoneum, and 5-mm trocars at corresponding sites on the left and right sides of the lower abdomen. All insertions were performed by the same operator using reusable trocar with a conical tip. Each subject acted as her own control. Recordings were successfully obtained from eight women. There was no instance of transducer failure. The mean (SE) peak contact surface pressure for the 10-mm and 5-mm left and right trocars were 5.3 (0.32), 6.4 (0.51), and 6.81 (0.27) pounds/square inch, respectively. Placement of the 10-mm trocar required less insertion force than placement of the 5-mm trocars. There was a strong negative correlation (r = -0.97, p < 0.001) between body weight and peak insertion force for the 10-mm trocar.

Adult↗

A new method of laparoscopic cholecystectomy using three trocars combined with suture retraction of gallbladder.

BACKGROUND AND PURPOSE: Since the establishment of laparoscopic cholecystectomy (LC) for benign gallbladder lesions, the four-trocar method has been the standard procedure. However, the fourth trocar generally is used just for fundic retraction of the gallbladder. We have developed a three-trocar method for LC and performed it in 132 patients. PATIENTS AND METHODS: After the creation of the pneumoperitoneum, the first 10-mm trocar sheath was inserted in the subumbilicus for the endoscope, the second 5-mm trocar in the epigastric paramedian point for the working port, and the third 5-mm trocar in the subcostal area for grasping forceps. Monofilament nylon with a straight needle was inserted through the right 7th intercostal space in the anterior axillary line, and the seromuscular layer of the gallbladder fundus was punctured and retracted toward the anterior abdominal wall. After that, usual cholecystectomy was performed. RESULTS: Among the 132 patients who underwent the three-trocar method, 10 cases (8%) needed a fourth trocar. No patient was converted to open cholecystectomy. There were no significant differences in the operating time, the length of hospital stay after the operation, or the use of analgesics between the three-trocar and the four-trocar methods. No major complication was recognized. CONCLUSION: This method also has cosmetic advantages. Therefore, we believe this method might be recommended for LC.

Cholecystectomy, Laparoscopic↗

Transperitoneal laparoscopic nephrectomy in children: surgical technique with 3 trocars.

INTRODUCTION: The first videolaparoscopic nephrectomy in children was performed in 1992, and since then, little experience, and small series of pediatric patients have been reported. The technique, described by Clayman and accepted worldwide, requires the insertion of 4 or 5 trocars. Introduction of trocars is an important cause of complication in videolaparoscopic surgery. The authors report laparoscopic transperitoneal nephrectomy in children using only 3 trocars, to minimize risk of vascular injury or visceral perforation. SURGICAL TECHNIQUE: The patient is placed in supine position with flank rotated at approximately 45(degrees). After pneumoperitoneum is established, the first trocar is introduced in umbilicus for the laparoscope. Under direct vision, the second trocar is placed at ipsilateral midclavicular line, and the third and last trocar in the epigastric region. Laparoscopic transperitoneal nephrectomy was performed in 3 children aged 7, 8, and 14 years old. Right nephrectomy was performed in 2 cases, and left nephrectomy in one. Mean operative time was 163 min (100 to 230 min), and no transfusion was necessary. Patients were discharged from hospital on day 2 to 4 after the procedure. There were no conversions to open surgery, and no intra or postoperative complications. COMMENTS: Every trocar and instrument introduction into the abdominal cavity presents an important risk of vascular injury or visceral perforation. The risk per patient is naturally increased with the number of trocars utilized. Injuries during laparoscopic procedures can theoretically damage every intra- or retroperitoneal organ. The majority of these lesions will need immediate or delayed open surgery, due to hematoma formation, postoperative bleeding, abscess, or peritonitis. Transperitoneal videolaparoscopic nephrectomy in children can be performed using only 3 trocars. The technique allows a better cosmetic result, and reduces the risk of trocar introduction injuries, like vascular and visceral lesions.

Journal Article↗

Clinical experience with an optical access trocar in gynecological laparoscopy-pelviscopy.

BACKGROUND AND OBJECTIVES: Development in surgical technology must demand not only improved efficacy and risk reduction but also a reduction in costs and efficient use of human resources. For 25 years we have discussed the development of optical access trocars and their probable benefits. They are now available in the form of the OPTIVIEW by Ethicon and the SURGIVIEW by US Surgical. METHODS: Between December 1996 and March 1997, we utilized the optic obturator trocar, OPTIVIEW, in 104 cases of gynecological operative laparoscopy. The instrument was equipped with an axial grip to facilitate ergonomic handling. RESULTS: The optical trocar was used with a Z-incision techniques in 16 cases; a vertical incision was used in 58 cases. In all of the gynecological procedures, the optical trocar was more advantageous than classic trocars placed without direct vision. Our estimation was that separation of tissue layers was very good in 71 cases, good in 26 cases and problematic in 5 cases. No complications occurred with the use of this trocar. The Z-incision was preferable to the vertical incision although it required a longer time of insertion of up to 5 seconds. Altogether, the OPTIVIEW presented an easy way of avoiding intestinal and vascular injury during initial trocar entry. CONCLUSIONS: The application of this new tool is practical, safe and handy. However, it requires training in its appropriate use. Vertical incisions should be sutured after removal of the instrument. Additional trocars need not be optical trocars as they can be placed under direct vision and laparoscopic control. It is our opinion that a combination of sophisticated new technologies such as the OPTIVIEW trocar, robotic arm, harmonic scalpel and 3-D vision would provide safe and efficient means to accomplish gynecologic laparoscopic surgical procedures.

Adult↗

Clinical and laboratory evaluation of an electrosurgical laparoscopic trocar.

Electrosurgical energy may be utilized as an adjunct to mechanical force for insertion of laparoscopic trocars. The advantage of this approach may be better operator control of insertion, with less risk of intraperitoneal and retroperitoneal injury. To assess the safety and efficacy of electrosurgical trocars, we compared them to mechanical trocars in clinical and animal trials. During 100 trocar introductions in 25 laparoscopic cholecystectomies, insertion force was measured. In contrast to mechanical trocars, which required progressively more force to insert as size increased, electrosurgical trocars required the same low insertion force regardless of size. No wound complications occurred. In animal experiments, wound healing (measured histologically and by bursting strength) was normal and equivalent for mechanical and electrosurgical insertions. We conclude that electrosurgical trocars require less force for insertion and do not impair wound healing. Electrosurgical trocars may thus offer important safety advantages over mechanical trocars.

Abdominal Muscles↗

Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures.

BACKGROUND: The use of the Veress needle in laparoscopy to create the pneumoperitoneum has inherent risks; it may cause vascular and visceral injuries. The open technique is compromised by the leakage of carbon dioxide and can also be time consuming. One alternative is to enter the abdomen using an optical trocar under direct view. Our aim was to determine whether the optical access trocar can be used to effect a safe and rapid entry in various laparoscopic procedures. METHODS: Over a 4-year period, the Optiview trocar was used for initial entry in 650 laparoscopic procedures. The procedures included cholecystectomy (n = 282), transabdominal inguinal hernia repair (n = 76), radiofrequency ablation of liver tumors (n = 73), adrenalectomy (n = 54), appendectomy (n = 41), colorectal surgery (n = 39), and various other procedures (n = 85). The following parameters were analyzed: presence of previous abdominal operations, site and duration of entry, and complications. RESULTS: Of the 650 patients, 156 (24%) had had previous abdominal operations. In 25 cases, previous trocar sites were reused for optical access. The optical trocar was inserted at the umbilicus in 495 patients (76%), in the right upper quadrant in 77 (12%), in the left upper quadrant in 26 (4%), in the upper midline in eight (1%), in the right lower quadrant in six (0.9%), and in the left lower quadrant in three (0.5%). In 35 patients undergoing posterior adrenalectomy, optical trocars were used to enter Gerota's space. Mean (SD) entry times were 92 (45) sec at the umbilical site, 114 (30) sec at the back, and 77 (35) sec at the remaining sites. Complications (0.3%) included one injury to the bowel and one injury to the gallbladder; however, they were recognized and repaired immediately. CONCLUSIONS: To our knowledge, this report comprises the largest series in which the optical access trocar was used for laparoscopic surgery. This device provides the basis for a safe and fast technique for initial trocar placement: it also has the potential to reduce costs. Thanks to our favorable experience, the optical trocar method has become the standard technique for abdominal access in our laparoscopic practice since 1995.

Abdomen↗

Anatomic relationships of infracoccygeal sacropexy (posterior intravaginal slingplasty) trocar insertion.

OBJECTIVE: The purpose of this study was to describe the distances of the major bony, vascular, neurologic, and visceral structures to the path of the infracoccygeal sacropexy trocar and to determine the point of trocar entry into the vagina. STUDY DESIGN: Infracoccygeal sacropexy trocars were inserted bilaterally into 6 fresh frozen cadavers. Dissection was performed and the maximal length of the vagina, ischiorectal fossa, and pararectal spaces were measured bilaterally. Mean distances with 95% CIs to important anatomic structures were made from fixed points along the trocar's path. RESULTS: The path of the trocar began dorsal and lateral to the anus, passed through the ischiorectal fossa, iliococcygeus muscle, into the pararectal space, and into the posteriolateral vagina. Along this course, the mean distance (95% CI) to the pudendal vessels at the exit of Alcock's canal was 2.8 cm (2.1 to 3.4 cm) and rectum was 0.5 cm (0.2 to 0.9 cm). The closest inferior rectal vessel was 0.1 cm (0 to 0.3 cm). In the pararectal space, the mean distance to the ischial spine was 2.6 cm (1.7 to 3.5 cm). In 12 of 12 trocar passages, the inferior rectal branches of the pudendal artery and the rectum were within 1 cm or less of the trocar. The mean distance of trocar entry into the vagina was only 4.8 cm (4.3 to 5.4 cm) proximal to the hymenal ring compared with a mean total vaginal length of 8.7 cm (8.0 to 9.3 cm). CONCLUSION: This anatomic study suggests that the rectum and the inferior rectal branches of the pudendal neurovascular bundle may be at risk of injury during infracoccygeal sacropexy trocar placement. Additionally, this procedure appears to provide support to the mid-posterior vaginal wall, not the vaginal apex.

Cadaver↗

Trocar injuries in laparoscopic surgery.

BACKGROUND: Disposable trocars with safety shields are widely used for laparoscopic access. The aim of this study was to analyze risk factors associated with injuries resulting from their use as reported to the Food and Drug Administration. STUDY DESIGN: Manufacturers are required to report medical device-related incidents to the Food and Drug Administration. We analyzed the 629 trocar injuries reported from 1993 through 1996. RESULTS: There were three types of injury: 408 injuries of major blood vessels, 182 other visceral injuries (mainly bowel injuries), and 30 abdominal wall hematomas. Of the 32 deaths, 26 (81%) resulted from vascular injuries and 6 (19%) resulted from bowel injuries. Eighty-seven percent of deaths from vascular injuries involved the use of disposable trocars with safety shields and 9% involved disposable trocars with a direct-viewing feature. The aorta (23%) and inferior vena cava (15%) were the vessels most commonly traumatized in the fatal vascular injuries. Ninety-one percent of bowel injuries involved trocars with safety shields and 7% involved direct-view trocars. The diagnosis of an enterotomy was delayed in 10% of cases, and the mortality rate in this group was 21%. In 41 cases (10%) the surgeon initially thought the trocar had malfunctioned, but in only 1 instance was malfunction subsequently found when the device was examined. The likelihood of injury was not related to any specific procedure or manufacturer. CONCLUSIONS: These data show that safety shields and direct-view trocars cannot prevent serious injuries. Retroperitoneal vascular injuries should be largely avoidable by following safe techniques. Bowel injuries often went unrecognized, in which case they were highly lethal. Device malfunction was rarely a cause of trocar injuries.

Abdominal Muscles↗

Trocar site herniation following laparoscopic cholecystectomy and the significance of an incidental preexisting umbilical hernia.

With the expansion of both laparoendoscopic surgery and the number of those performing it, the surgeon must remain cognizant of the uncommon complication of herniation through a previous trocar site. Herniation through laparoscopic trocar defects most often occurs as a Richter's hernia, hence its presentation can be insidious and can lead to significant morbidity. A retrospective chart review of 1300 consecutive laparoscopic cholecystectomies over 5 years was performed. An incidence of 0.77 per cent for trocar site herniations was found. All of the trocar site hernias occurred through large (> or = 10 mm) defects at the umbilical site. Ninety per cent of those patients with trocar site herniations had an umbilical hernia or midline incisional hernia found incidentally upon entrance into the peritoneal cavity. All of the herniations occurred despite primary fascial closure of the trocar sites. One trocar site hernia resulted in a small bowel obstruction secondary to an incarcerated Richter's hernia. This required a small bowel resection. Consequently, we now close trocar fascial defects in patients with preexisting hernias in a formal fashion. We recommend that trocar ports be removed under direct vision and that large fascial defects (> or = 10mm) be primarily closed. Furthermore, we recommend in those patients with incidentally found umbilical hernias that both the fascial edge and complete extent of the hernia defect be defined and then closed as a formal herniorrhaphy with interrupted nonabsorbable suture and a synthetic patch if necessary.

Abdominal Muscles↗

Trocar site hernia.

OBJECTIVE: To review the relationship between the pathogenesis and clinical manifestations of trocar site hernias seeking to confirm the definition of trocar site hernias by classification. DATA SOURCES: We searched this subject in English on MEDLINE by combining the words "trocar," "port," "hernia, and "laparoscopy."Data Extraction and STUDY SELECTION: We limited the main operations to cholecystectomy, colon and rectal surgery, fundoplication, and gastric surgery; finding 44 reports on these procedures. Of these, 19 were case reports, 18 were original articles (setting criteria; the incidence of the trocar site hernia was clarified, and involved >100 patients), and 7 technical notes on "how to do it" were collected. We obtained 19 additional reports using the references of those previously obtained. We, thus, reviewed 63 reports (24 case reports, 27 original articles, 7 technical notes, and 5 review articles). DATA SYNTHESIS: Trocar site hernia was classified into 3 types. The early-onset type that occurred immediately after the operation, with a small-bowel obstruction, especially the Richter hernia, frequently developing. The late-onset type that occurred several months after the operation, mostly with local abdominal bulging with no small-bowel obstruction developing. The special type that occurred indicated the protrusion of the intestine and/or omentum. Trocar site hernias with fascial defects of 10 mm or larger should be closed, including the peritoneum. Opinion varied if a 5-mm trocar site defect should be closed. CONCLUSION: It is useful to clearly classify trocar site hernias to improve management of laparoscopic procedures.

Digestive System Surgical Procedures↗