PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Testing”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

A comparison between the 1-microg adrenocorticotropin (ACTH) test, the short ACTH (250 microg) test, and the insulin tolerance test in the assessment of hypothalamo-pituitary-adrenal axis immediately after pituitary surgery.

The short ACTH stimulation test is an easy, reliable, and extensively used test in the assessment of the hypothalamo-pituitary-adrenal (HPA) axis. However, its use immediately after pituitary surgery is a matter of debate. The insulin tolerance test (ITT) is the gold standard in the evaluation of the HPA axis, but it is not always without side effects and may be unpleasant early after pituitary surgery. Our aim was to investigate the value of the 1-microg ACTH test in the assessment of the HPA axis early after pituitary surgery. We also aimed to determine the value of the 1-microg and 250-microg ACTH tests and the ITT in the estimation of HPA axis status after 3 months postoperatively. Nineteen patients subjected to pituitary tumor surgery were included in the study, and the ITT and the 1-microg and 250-microg ACTH tests were performed between the 4th and 11th days of surgery. The tests were repeated at the first month in 3 patients with subnormal peak cortisol responses (454, 125, and 301 nmol/L) and in 18 patients at the third month postoperatively. ACTH stimulation tests were performed by using 1 microg and 250 microg ACTH iv as a bolus injection, and blood samples were drawn at 0, 30, and 60 min for measurement of serum cortisol levels. The ITT was performed by using iv regular insulin, and serum glucose and cortisol levels were measured. The 1-microg and 250-microg ACTH stimulation tests and the ITT were performed consecutively. At least 48 h were allowed between each test. A peak serum cortisol level of 550 nmol/L or greater was considered as a normal response for both the ITT and the ACTH tests. The serum cortisol level was measured by RIA using commercial kits. Serum glucose was determined by glucose oxidase method. There were correlations between the peak cortisol response to the ITT and the 1-microg ACTH test (r = 0.39, P < 0.05) in the early postoperative period. No correlation was found between the ITT and the 250-microg ACTH test responses. In the early postoperative period, two patients showed normal cortisol responses (> or =550 nmol/L) to the 1-microg ACTH test and five patients showed normal cortisol responses to the 250-microg ACTH test among the six patients with subnormal cortisol responses to the ITT. Three patients with subnormal cortisol responses to ITT and baseline cortisol values less than 240 nmol/L showed normal HPA axis at the end of the first month. In the late postoperative period, at the third month, all the patients showed normal HPA axis. In the early postoperative period of pituitary surgery, the 1-microg ACTH test results are more concordant than the 250-microg ACTH test in comparison with the ITT. Our results also indicate that HPA axis dysfunction shown by ACTH stimulation tests and the ITT in early postoperative period may be normalized 1-3 months after surgery. For this reason, we think that dynamic tests including the ITT may not be useful early after pituitary surgery.

Adrenocorticotropic Hormone↗

Antigen testing for human immunodeficiency virus (HIV) and the magnet effect: will the benefit of a new HIV test be offset by the numbers of higher risk, test-seeking donors attracted to blood centers? Retrovirus Epidemiology Donor Study.

BACKGROUND: There currently is debate on whether to include new assays for viral antigens and nucleic acids in the battery of screening tests applied to all blood donations. Proposals call for implementation of p24 antigen screening tests to help identify donors who are infected with human immunodeficiency virus type 1 (HIV-1) but have not yet seroconverted (window-period donors). There is concern, however, that people at higher risk for HIV infection will be attracted to blood centers in order to obtain the results of an HIV assay that is not routinely available elsewhere. Therefore, the benefit of antigen testing may be offset by an increase in the HIV incidence rate among blood donors. STUDY DESIGN AND METHODS: Estimates were obtained from previous reports for the HIV incidence rate among blood donors, the percentage of donations from test-seeking donors, the duration of the HIV-infectious window period, and the performance of p24 antigen screening assays. Sensitivity analyses were performed by using various percentages of test-seeking donors following implementation of antigen testing and various HIV incidence rate ratios of test-seekers to nonseekers. Hypothetical residual HIV risks were calculated for multiple scenarios and compared to the current estimate of HIV risk without antigen screening of blood donations. RESULTS: If antigen testing reduces the window period by 27 percent (e.g., from 22 days to 16 days), and the HIV incidence rate among test-seekers is 30 times that among nonseekers, then the benefit of antigen testing will be eliminated if the percentage of test-seekers (currently estimated at 3.2%) increases to 5.7 percent. If antigen testing reduces the window period by approximately 45 percent (e.g., from 22 days to 10 days or from 13 days to 6 days) and the HIV incidence rate ratio (test-seekers vs. nonseekers) is assumed to be equal to the HIV prevalence ratio (5.3), then the percentage of donations from test-seeking donors would have to increase to 25 percent of all donations to offset the benefit of antigen screening. CONCLUSION: This model helps identify the key measures for assessing the potential adverse effect of increased test seeking as a consequence of the addition of p24 antigen (or other direct virus) assays to blood donor screening programs. In most scenarios, the beneficial effect of antigen screening exceeded the potential detrimental effect of attracting higher-risk, test-seeking donors. The possibility cannot be ruled out, however, that a subgroup of high-risk, test-seeking donors attracted to the blood centers by a new HIV test will offset the reduction in the residual risk of HIV infection associated with antigen screening.

AIDS Serodiagnosis↗

Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.

The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98.1%; between the Beckman RPR card and the VDRL slide tests, 95.0%; and between the reference RPR card and the VDRL slide tests, 95.5%. The Beckman RPR card test was 95.3% specific, whereas the specificities of the reference RPR card and the VDRL slide tests were 98.8% and 96.1%, respectively. Sensitivities of the three nontreponemal tests were: Beckman RPR card test production lots, 94.7%; reference RPR card test, 96.8%; and VDRL slide test, 90.6%. Quantitative agreement +/- 1 dilution among the three RPR card tests was 93.0%, whereas quantitative agreement was approximately 40% when both RPR card tests were compared with the VDRL slide test. We found the Beckman RPR card test comparable to the standard RPR card tests. Therefore, the decision of which test to use for the serodiagnosis of syphilis is at the discretion of the user.

Antibodies↗

False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test.

Although tests for detection of immunoglobulin M (IgM) toxoplasma antibodies have been reported to have a high degree of accuracy, it is well recognized by investigators in the United States and Europe that false-positive results may occur with many of these tests, at times to an alarming degree. Unfortunately, this information is not well documented in the literature. Studies on various toxoplasma IgM test kits are frequently flawed. The investigators often use reference tests which have not previously been carefully evaluated as well as sera that were not appropriate to answer the question of how often false-positive results might occur. We recently had the unique opportunity to evaluate the accuracy of the Platelia Toxo IgM test in 575 serum samples obtained during an outbreak of toxoplasmosis which occurred in 1995 in the Capital Regional District of British Columbia, Canada. When compared with results obtained in a reference IgM enzyme-linked immunosorbent assay (ELISA), the Platelia Toxo IgM test had a sensitivity of 99.4%, specificity of 49.2%, positive predictive value of 51.9%, negative predictive value of 99.3%, and an overall agreement of 67.0%. In an attempt to resolve discrepancies between these two tests, a serological profile (Sabin-Feldman dye test, IgA and IgE antibody tests, differential agglutination [AC/HS] test, and IgG avidity method) was performed. Of 153 serum samples that were positive in the Platelia Toxo IgM test and negative in the IgM ELISA, 71 (46.4%) were negative in the Sabin-Feldman dye test. Of the serum samples that were positive in the dye test, 77 (93.9%) had a serological profile most compatible with an infection acquired in the distant past. These results reveal high numbers of false-positive results in the Platelia Toxo IgM test and highlight the importance of appropriate evaluation of commercial tests that are currently being marked. Our results also emphasize the importance of confirmatory testing to determine whether the results of an IgM antibody test reflect the likelihood of a recently acquired infection.

Animals↗

GH stimulation tests: evaluation of GH responses to heat test versus insulin-tolerance test.

OBJECTIVE: Heat exposure has been shown to stimulate GH release, but the specificity and the reproducibility have not been determined, and the test has not been compared with validated GH stimulation tests in adulthood. We therefore tested the specificity and the reproducibility of the heat exposure test in healthy subjects and compared the results with those obtained with the insulin-tolerance test (ITT). DESIGN: Ten healthy non-obese men, aged 31.3+/-4.80 years, underwent four GH stimulation tests in random order: two ITTs and two heat exposure tests. In the heat test, subjects were placed in a hot bath with water temperature at 40.3+/-0.11 degrees C for 45 min, resulting in an identical (P = 0.477) significant increase in tympanic temperature of 1.26+/-0.05 and 1.41+/-0.07 degrees C in the two tests. RESULTS: Peak GH response to the heat exposure test was less than the peak GH response to ITT (5.25+/-1.72 vs 15.5+/-3.17 microg/l, P = 0.006). Furthermore the specificity (arbitrary cut-off level = 3 microg/l) of the heat test was lower than of the ITT (8/17 vs 18/20, P = 0.006). The coefficient of variation did not differ between the two tests (heat test 0.31, ITT 0.36, P = 0.77). Peak GH values in the individual tests were highly correlated (heat, r = 0.908, P = 0.002; ITT, r = 0.815, P = 0.004). Reproducible increments in the circulating levels of stress hormones were observed during ITT. but these hormones remained largely unchanged during heat exposure. CONCLUSIONS: The heat exposure test is not a reliable GH stimulation test compared with the ITT in adults. This study documents that the ITT has a high specificity and reproducibility in the diagnosis of GH deficiency in adulthood. We propose that the heat exposure test is not used in the diagnosis of this condition in adulthood.

Adult↗

Reactions to cognitive ability tests: the relationships between race, test performance, face validity perceptions, and test-taking motivation.

The relationships among race, face validity perceptions, test-taking motivation, and test performance on a cognitive ability test were examined. Undergraduates completed 2 parallel cognitive ability tests and a test reactions measure. Results showed that test-taking motivation was related positively to subsequent performance on a parallel test even after the effects of race and performance on the first test were controlled. The effect of race on subsequent test performance was found to be mediated partially by motivation that provided evidence that some portion of the Black-White difference in test performance may be explained through differences in test-taking motivation. Results also indicated that Black-White differences in face validity perceptions of the test may be a function of Black-White differences in test performance. Face validity perceptions of the test affected subsequent performance on the parallel test but only indirectly through test-taking motivation.

Achievement↗

Comparison of the sensitivities of the Buehler test and the guinea pig maximization test for predictive testing of contact allergy.

International test guidelines, such as the Organisation for Economic Cooperation and Development (OECD) guideline #406, recommend 2 guinea pig methods for testing of the contact allergenic potential of chemicals: the Guinea Pig Maximization Test (GPMT) and the Buehler test. Previous comparisons between the methods suggested that the Buehler test was less sensitive than the GPMT although modified Buehler test protocols were used. Parallel GPMT and Buehler tests were conducted according to OECD guideline #406 using a multiple-dose design and test results were analysed using a standard logistic dose-response model. To compare the sensitivity of the 2 test procedures the test conditions were kept identical and the following chemicals with a range of sensitization potentials were tested: chloraniline, chlorhexidine, eugenol, formaldehyde, mercaptobenzothiazole and neomycin sulphate. Formaldehyde and neomycin sulphate were strong sensitizers in both tests. Mercaptobenzothiazole, eugenol and chloraniline were all strong sensitizers in the GPMT, eugenol and mercaptobenzothiazole were negative in the Buehler test and equivocal results were obtained with chloraniline. Chlorhexidine was negative in the GPMT and equivocal responses were obtained with the Buehler test. Higher induction concentrations were needed to show allergenicity in the Buehler test and for some allergens the Buehler test protocol was not sensitive enough to demonstrate allergenic potential.

Allergens↗

Fluconazole and amphotericin B antifungal susceptibility testing by National Committee for Clinical Laboratory Standards broth macrodilution method compared with E-test and semiautomated broth microdilution test.

A comparative study of fluconazole and amphotericin B susceptibility testing was performed with 68 clinical Candida species isolates and three test methods. The methods used were an agar diffusion method (E-test) and two broth dilution methods, the National Committee for Clinical Laboratory Standards (NCCLS) reference broth macrodilution method and an in-house-prepared semiautomated broth microdilution method based on the Bioscreen turbidometer. In the microdilution method, growth of the yeasts was measured continuously by the automatic turbidometer (Bioscreen), which permitted precise and objective determination of endpoints. MIC endpoints were read after 24 h for the microdilution method and the E-test. Amphotericin B susceptibility testing with the NCCLS method and the E-test yielded comparable results in 89% of the tests, meaning that the endpoints obtained were identical or differed by no more than 2 twofold dilutions. The NCCLS and broth microdilution tests scored 97% comparable results, and the E-test and the broth microdilution test yielded 90% comparable results. Fluconazole susceptibility testing produced 96% comparable results with the NCCLS test and the E-test, 100% comparable results with the NCCLS and the microdilution methods, and 98.5% comparable results with the microdilution method and the E-test. We conclude that the E-test and the Bioscreen microdilution method are valuable alternatives to the NCCLS reference method for routine susceptibility testing of Candida species with fluconazole and amphotericin B.

Amphotericin B↗

Evaluation of eight methods for identification of pathogenic Neisseria species: Neisseria-Kwik, RIM-N, Gonobio-Test, Minitek, Gonochek II, GonoGen, Phadebact Monoclonal GC OMNI Test, and Syva MicroTrak Test.

The performance of eight methods in identifying Neisseria species, particularly N. gonorrhoeae, was evaluated. These methods included four rapid carbohydrate utilization tests (Gonobio-Test, Neisseria-Kwik, RIM-N, and Minitek); the Gonochek II, a test which is based on the utilization of chromogenic substrates; and three monoclonal antibody tests (Syva MicroTrak, GonoGen, and Phadebact Monoclonal GC OMNI Test). In all, 182 isolates comprised in six species of Neisseria as well as Branhamella catarrhalis and Moraxella sp. were tested. Cystine-tryptic digest agar supplemented with sugars was included for reference purposes. In the carbohydrate utilization tests, the sensitivity and specificity of the Neisseria-Kwik and Minitek tests for the identification of N. gonorrhoeae were 100%. This compared with sensitivities and specificities, respectively, of 100 and 99.1% for the Gonobio-Test and 99.1 and 100% for cystine-tryptic digest agar sugars and the RIM-N test. The sensitivity and specificity of the Gonochek II test were 99.0 and 86.7%, respectively. Although most test kits did not claim to identify all Neisseria species, in several cases isolates of N. subflava were misidentified or could be misinterpreted as N. gonorrhoeae or N. meningitidis. With the monoclonal reagents, the Syva MicroTrak system was 100% sensitive and 100% specific. The GonoGen test was both 99.1% sensitive and specific, while the Phadebact Monoclonal GC OMNI Test was 99.1% sensitive but 91.2% specific. With this latter test, cross-reactions were observed with strains of B. catarrhalis, N. cinerea, and N. lactamica.

Agglutination Tests↗

Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screening.

BACKGROUND: This study evaluated the change from a rapid plasma reagin (RPR) test to an automated specific treponemal test (PK-TP) in screening for syphilis in blood donors. STUDY DESIGN AND METHODS: A cross-sectional seroprevalence analysis was performed on 4,878,215 allogeneic blood donations from 19 American Red Cross Blood Services regions from May 1993 through September 1995. Positive predictive values relative to the confirmatory fluorescent treponemal antibody absorption test (FTA-ABS) were calculated. Differences in seroprevalence were compared in RPR and PK-TP tests for 1) unconfirmed and confirmed tests, 2) first-time and repeat donors, and 3) "recent" versus "past" infections. Donation data from three additional Red Cross regions were evaluated for repeat donation patterns of blood donors who had a donation that was positive in a serologic screening test for syphilis. The value of RPR and PK-TP tests as surrogate markers for HIV infection was compared. RESULTS: Reactive rates were lower but the positive predictive values was higher for the PK-TP test than for the RPR test. Initially, donors screened by PK-TP were more likely to be confirmed as positive than were donors screened by RPR, but these rates became comparable. It is estimated that a single HIV window-period donation was removed by serologic testing for syphilis each year of this study period. CONCLUSIONS: The change to the PK-TP test resulted in a lower repeatedly reactive rate, better prediction that a confirmed-positive test for syphilis would occur in testing in the FTA-ABS, fewer donations lost, and comparable deferral rates. Because of the high rate of reactivity to serologic testing for syphilis among donors previously confirmed positive for syphilis, indefinite deferral after a confirmed-positive index donation may be warranted. Serologic testing for syphilis is ineffective as a marker of HIV-infectious window-period donations.

Antibody Specificity↗

Reliability of the isokinetic trunk extensor test, Biering-Sørensen test, and Astrand bicycle test: assessment of intraclass correlation coefficient and critical difference in patients with chronic low back pain and healthy individuals.

STUDY DESIGN: A reliability study was performed. OBJECTIVE: To determine the intersession reproducibility of the isokinetic trunk extensor strength test, the Biering-Sørensen test, and the Astrand test by calculation of the intraclass correlation coefficient and the critical difference. SUMMARY OF BACKGROUND DATA: Several physical measurements have been used in clinical evaluation of patients with chronic low back pain. Reliability can be evaluated by calculation of either intraclass correlation coefficient or critical difference, but interpretation of the results may vary depending on which method is used. METHODS: For this study, 31 patients with chronic low back pain carried out the isokinetic trunk extensor test, the Biering-Sørensen test, and the Astrand test as also did age- and gender-matched healthy individuals. Measurements were performed in three separate sessions at the same time of the day and by the same experienced examiner. The intervals between the sessions were 5 to 10 days. RESULTS: The isokinetic tests showed a learning effect between Tests 1 and 2. For the isokinetic test, the critical difference increased with increased angular velocities from 28% to 63% in the patients and from 27% to 39% in the healthy subjects. The critical differences for the patients and the healthy individuals were 57% vs 54% for the Biering-Sørensen test and 21% vs 23% for the Astrand test, respectively. The intraclass correlation coefficient ranged from 93% to 98% in the patients and 80%-98% in the healthy individuals. CONCLUSIONS: The reliability was found to be acceptable for the Astrand test and the isokinetic test at 60 degrees per second, as evaluated by the critical difference. All the tests were highly reliable according to the intraclass correlation coefficient, except for Biering-Sørensen test for healthy individuals. The critical difference is the preferable measure because calculation of the intraclass correlation coefficient may give a misleading high estimate of reliability.

Adult↗

Reproducibility of patch test results: comparison of TRUE Test and Finn Chamber test results.

To evaluate the reproducibility of patch test results, duplicate patch test series comprising 12 allergens were simultaneously applied to either side of the back in 63 patients by the use of a newly developed patch test system, TRUE Test. When a positive test result occurred on only one side of the back, it was regarded as nonreproducible. For evaluation of the concordance of test reactions between the TRUE Test and the Finn Chamber test, the same 12 allergens mixed in petrolatum were also applied to the upper back according to the Finn Chamber technique. The reproducibility of TRUE Test results was compared with the reproducibility of the Finn Chamber test in 76 other patients. The concordance of positive reactions between the two tests was 57%, somewhat lower than in recently published studies. The percentage of nonreproducible positive results was more than twice as high with Finn Chambers, (22 of 58 positive reactions, or 37.9%) as with the TRUE Test (5 of 28 reactions, or 17.9%). However, this difference in reproducibility in the two test systems was not significant as determined by the chi 2 test (p less than 0.05).

Allergens↗

Genotoxicity assessment of suspended particulate matter in the Elbe river: comparison of Salmonella microsome test, arabinose resistance test, and umu-test.

This study evaluates the applicability of three bacterial short-term genotoxicity test systems to aquatic suspended particulate matter of the Elbe river. This material was sampled in sedimentation vessels after deposition periods of one month. It was extracted in a Soxhlet apparatus with toluene and methanol. Aqueous elutriates were prepared additionally. A solid phase method was developed that enables to incubate bacteria in contact with the particulate material. The test battery consists of two mutagenicity assays (the Ames-test and the Ara-test) and an SOS induction assay (the umu-test). Both mutagenicity assays came to nearly the same assessment of the samples of particulate matter of the Elbe. The quantitative response, however, was higher in the Ara-test. The particulate river material generally induced lower genotoxic potencies in the umu-test than in the mutagenicity assays. This lead to a completely different outcome of the umu-test; 29 out of 35 mutagenic samples were not SOS inducing. No quantitative or rank correlations between the concentrations of anthropogenic contaminants (PAHs, chlorinated hydrocarbons and metals) and the observed effects could be established on a 90% confidence limit. However, there is obvious correspondence between more contaminated regions of the river system and mutagenic effects (Ames- and Ara-test) in the samples from this region, as well as correspondence between low contaminated regions and the absence of mutagenicity. For this reason, the mutagenicity assays appear more favourable to describe the anthropogenic contamination with genotoxins in complex mixtures than the umu-test. The authors recommend the Ara-test for a first genotoxicity screening of complex environmental mixtures. This forward mutagenicity assay is advantageous due to higher effects and lower costs compared to the Ames-test. The development and use of a solid phase version of Ames- and Ara-test revealed the occurrence of a major part of particle-bound mutagens. The hydrophobic nature of these mutagens was also confirmed by the gradually decreasing effects with decreasing lipophilicity of the solvents. The results suggest that the solid phase test and the use of extracts complement each other in detecting mutagens of different lipophilicity. Both versions should be used in order to include a broad variety of compounds.

Arabinose↗

Carrier testing of children for two X-linked diseases: A retrospective study of comprehension of the test results and social and psychological significance of the testing.

OBJECTIVE: To evaluate long-term consequences of genetic carrier testing performed in childhood in terms of awareness and comprehension of the test result, and the social and psychological significance of such testing. STUDY DESIGN: The families of 66 young females who had been tested for carriership during childhood between 1984 and 1988 were approached. Of the 66 families, 23 young females in families affected by Duchenne muscular dystrophy (DMD), 23 young females in families affected by hemophilia A (HA), and their mothers participated in our study. We used a questionnaire including multiple-choice and open-ended questions. RESULTS: Of the young female participants tested in the families affected by DMD or HA, 65% knew their test results. Only 65% of DMD mothers and 78% of HA mothers remembered correctly the test results of their daughters. The majority (83%) of the young females tested sought no genetic counseling when reaching adulthood. The reason for this was not determined. Most (78%) reported that the test result had not influenced their lives, whereas some felt relieved to know they had not been carriers. Talking about hereditary disease in the family and between friends was open, and results of the carrier test had usually been told to friends. CONCLUSION: Carrier testing was in most cases correctly understood and the matter openly discussed. Our results do not suggest that testing in childhood had caused serious harm to the young individuals tested. On the other hand, we found no obvious benefits from this early testing.

Adolescent↗

Noninvasive Helicobacter pylori testing for the "test-and-treat" strategy: a decision analysis to assess the effect of past infection on test choice.

BACKGROUND: Clinical guidelines support a noninvasive Helicobacter pylori "test-and-treat" strategy for individuals with uncomplicated dyspepsia. However, consensus is lacking regarding the preferred noninvasive testing method. OBJECTIVE: To use decision analytic modeling to estimate the clinical and economic outcomes associated with noninvasive tests designed to detect either H pylori antibody or active H pylori infection. DESIGN: Decision analytic model. PATIENTS: A simulated patient cohort with uncomplicated dyspepsia. INTERVENTIONS: The simulated dyspepsia cohort underwent antibody testing or testing to detect active H pylori infection (active testing). Individuals testing positive received eradication therapy. MAIN OUTCOME MEASURES: Appropriate and inappropriate treatment prescribed, cost per patient treated, incremental cost per unnecessary treatment avoided. RESULTS: Active testing led to a substantial reduction in unnecessary treatment for patients without active infection (antibody, 23.7; active, 1.4 per 100 patients) at an incremental cost of $37 per patient. The clinical advantage and cost-effectiveness of active testing was enhanced as the percentage of individuals with a positive antibody test result from past, but not current, infection increased. CONCLUSIONS: Active testing for H pylori infection significantly decreases the inappropriate use of antimicrobial therapy when compared with antibody testing. The advantages of active testing should be enhanced as the widespread use of antimicrobial agents increases the proportion of patients with antibody to H pylori, but without active infection.

2-Pyridinylmethylsulfinylbenzimidazoles↗

Mutagenicity testing of protein-containing and biological samples using the Ames/Salmonella plate incorporation test and the fluctuation test.

Mutagenicity testing of biological samples and proteins is complicated by the presence of histidine and histidine-related growth factors which may produce a false positive result in the Ames/Salmonella plate incorporation test. A bioassay method, utilizing an automated dispenser-photometer and Salmonella typhimurium strain TA1535 as the indicator bacteria, was used to estimate the presence of histidine-related growth factors in three enzyme solutions submitted for mutagenicity testing. One of the solutions was clearly positive in the Ames/Salmonella test and also contained the highest amount of L-histidine-HCl-equivalents. The two other solutions, with low or undetectable amounts of L-histidine-HCl-equivalents, gave equivocal and negative results, respectively, in the Ames/Salmonella test. Studies were also performed with strains TA98, TA100 and TA1535 to determine the amount of added L-histidine-HCl that would result in a 'positive' result in the Ames/Salmonella test. Because the minimum amount of L-histidine-HCl required to double the number of revertant colonies was 150 nmol/plate, and the maximum amount of L-histidine-HCl-equivalents supplied by the enzyme preparations was 40 nmol/plate at the highest tested dose, the mutagenicity test results of the enzyme solutions cannot be explained solely by histidine or related compounds. Smokers' and non-smokers' urines, concentrated with liquid extraction (CHCl3) and adsorbent (XAD-2 and XAD-2/Sep-Pak C18) techniques, were studied to reveal differences in efficiencies to extract histidine and histidine-related compounds in the urines. Amounts of 'histidine' in concentrates of urine were measured using the bioassay method and a chemical method employing derivatization with fluorescamine. The fluorescamine method also efficiently detected 3-methyl-L-histidine, a product of muscle metabolism excreted in urine, which was found to be unable to support auxotrophic growth in TA1535, leading to exaggerated estimations of the auxotrophic growth enhancing properties of urine extracts. The urine extracts, and pure L-histidine-HCl, were tested using a two-step fluctuation test to estimate auxotrophic growth factor effects in this type of test. Because of a strong dilution effect when adding the histidine-free selection medium, the fluctuation test employed in this study was not found to be particularly sensitive to growth factors. The results of this study indicate that use of a bioassay, employing the same indicator bacteria as the mutagenicity test themselves, is a reliable way to measure histidine-related growth factors in biological samples.(ABSTRACT TRUNCATED AT 400 WORDS)

Enzymes↗

Comparison of five methods, including the PDM Epsilometer test (E test), for antimicrobial susceptibility testing of Pseudomonas aeruginosa.

The antimicrobial susceptibilities of 100 clinical isolates of Pseudomonas aeruginosa to six antipseudomonal antibiotics were tested by five methods: the National Committee for Clinical Laboratory Standards (NCCLS) methods for broth microdilution, agar dilution, and agar disk diffusion; the Vitek Automicrobic System method (Vitek Systems, Hazelwood, Mo.); and the PDM Epsilometer test (E test) (AB Biodisk, Solna, Sweden). The E test results showed excellent correlation with agar dilution results, with over 90% agreement within 1 doubling dilution between the E test and reference agar dilution MICs for all antimicrobial agents tested. The E test results also showed good correlation with the results from the reference agar disk diffusion method, with 90 to 99% complete agreement and 100% essential agreement on categories for all antibiotics tested (essential agreement is the agreement obtained when minor discrepancies are ignored). Comparison of categories with the E test and broth microdilution methods, using the broth microdilution method as the reference method, gave only 59% complete agreement for gentamicin, with 28 minor discrepancies and 13 very major discrepancies. Some discrepancies were observed between results from the E test and broth methods for gentamicin, with the broth microdilution and Vitek methods giving higher MICs than the E test and other methods using agar. The most recent NCCLS guidelines for broth dilution testing have reduced the recommended levels of cation supplementation, which may enhance future agreement between results for the aminoglycosides and P. aeruginosa on broth and on agar. We found that the E test offers a simple, labor-efficient, and accurate method for MIC determination on an agar medium.

Adult↗

The micronucleus test as part of a short-term mutagenicity test program for the prediction of carcinogenicity evaluated by 143 agents tested.

To evaluate the usefulness of the micronucleus test as a short-term assay for the detection of carcinogens, the correlation between micronucleus test data for 143 chemicals and corresponding cancer data, has been analyzed. For comparison, analogous data from Ames's test have also been collected for the same chemicals. In a comparison of the micronucleus test and Ames's test it was found that they had about the same specificity (around 80%) and predictive value (around 90%), while there was a significant difference in sensitivity in favor of Ames's test. The difference in sensitivity could be partly explained by differences in metabolizing capacities of these two test systems. It is concluded that a more elaborate test procedure for the micronucleus test would increase that sensitivity of this test. The principal value of the micronucleus test lies in the fact that it is an in vivo method, which may pick up effects at the chromosomal level not covered by bacterial assays. This is emphasized by the finding that the combination of Ames's test and the micronucleus test did increase the sensitivity of the screening procedure for the prediction of carcinogenic effects.

Animals↗