PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ventricular volume”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography.

BACKGROUND: The aim of this study was to compare 8- and 16-frame gated blood pool single photon emission computed tomography (SPECT) (GBPS) for the determination of right ventricular ejection fraction (RVEF) and right ventricular (RV) volumes in subjects who underwent two consecutive GBPS studies. METHODS AND RESULTS: In this study 65 consecutive patients (29 men and 36 women) referred for first-pass radionuclide angiography (FP-RNA) underwent FP-RNA and both 8- and 16-frame GBPS. The mean FP-RNA RVEF was statistically lower than RVEF determined by 8-frame GBPS (P < .001) and 16-frame GBPS (P < .001). Comparison of RVEF by FP-RNA and GBPS yielded coefficients of 0.8666 (P < .0001) for 16-frame GBPS and 0.7290 (P < .0001) for 8-frame GBPS. The correlation of RVEF between 8- and 16-frame GBPS showed a coefficient of 0.6657 (P < .0001). The mean RV end-diastolic volume (EDV) calculated with 8- and 16-frame GBPS showed no statistical differences (P = .3580). The mean RV end-systolic volume (ESV) calculated with 8- and 16-frame GBPS also showed no statistical differences (P = .2265). Comparison of EDV by 8- and 16-frame GBPS yielded a coefficient of 0.7327 (P < .0001). The correlation between ESV by 8-frame GBPS and 16-frame GBPS showed a coefficient of 0.6067 (P < .0001). CONCLUSION: GBPS is a simple and reproducible acquisition method for the assessment of RVEF and RV volumes. RVEF values calculated by 8- and 16-frame GBPS correlated well with FP-RNA, although mean RVEF values from FP-RNA were lower than GBPS RVEF values. In addition, RV ESV and EDV were both well correlated with 8- and 16-frame GBPS. GBPS should prove to be useful in diagnosis, as well as in following disease progression and evaluating the efficacy of therapeutic interventions, in patients with biventricular dysfunction.

Cardiac Volume↗

The genetic basis of cerebral ventricular volume.

Cerebral ventricular volume, assessed by computed tomography, is a genetically determined trait. In a series of 18 monozygotic and 18 dizygotic twins, heritability values ranged from 82% to 85% depending on the method of calculation.

Adult↗

Effect of large volume infusion on left ventricular volumes, performance and contractility parameters in normal volunteers.

OBJECTIVE: Characterize the normal human cardiovascular response to large volume infusion of normal saline. DESIGN: Prospective, interventional trial. SETTING: ICU procedure room. PARTICIPANTS: Healthy male volunteers ( n=32). INTERVENTIONS. Volumetric echocardiography during 4-L saline infusion (3 L over 3 h followed by 1 L over 2 h). MEASUREMENTS AND RESULTS: Following 3-L saline infusion, stroke volume and cardiac output increased approximately 10% without a significant change in heart rate or blood pressure. A decrease in end-systolic volume contributed to the increase in stroke volume to an extent similar to that provided by the increase in end-diastolic volume. All contractility indices except end-systolic wall stress/end-systolic volume index were increased at 3 h post-initiation of saline infusion. Stroke volume but not cardiac output remained elevated at 5 h with persistence of ventricular volume responses; only ejection fraction was significantly elevated among the contractility indices. Afterload measures including total peripheral resistance and end-systolic wall stress were significantly decreased after 3-L infusion but were unchanged compared to baseline following infusion of an additional 1 L over 2 h. Modeled blood viscosity studies demonstrate that changes in apparent contractility after 3-L saline infusion can be explained solely by viscosity reduction associated with hypervolemic hemodilution. CONCLUSION: The initial increase in stroke volume associated with high volume saline infusion in normal volunteers is associated with increases of most load-dependent and ostensibly load-independent parameters of left ventricular contractility. This phenomenon is unlikely to represent a true increase in contractility and appears to be caused by reduced afterload as a consequence of decreased blood viscosity. This decrease in blood viscosity may complicate analysis of some previous in vivo studies examining the effect of volume loading on cardiac function using low-viscosity solutions.

Adult↗

Ventricular volume following third ventriculostomy.

OBJECT: Ventricular size often shows no obvious change following third ventriculostomy, particularly in the early postoperative period, making postoperative evaluation difficult without expensive and often invasive testing in patients with equivocal clinical responses. The authors hypothesized that performing careful volumetric measurements would show decreases in size within the first 3 weeks after surgery. METHODS: Volumetric measurements were calculated from standard 3 x 3-mm axial computerized tomography (CT) scans obtained immediately before and 3 and 21 days after surgery. Two independent investigators measured third ventricular volume in a series of 16 patients and lateral ventricular volume in 10 of the patients undergoing stereotactically guided endoscopic third ventriculostomy for noncommunicating hydrocephalus. Fifteen patients were symptomatically improved at the time the follow-up scan was obtained. Third ventricular volume decreased in all patients by a mean of 35% (range 7.8-95.1%) and lateral ventricular volume decreased in all patients by a mean of 33% (range 4.5-80.3%). The degree of change correlated with the length of preoperative symptoms (p < 0.005). The one patient who experienced no improvement showed no decrease in third ventricular volume. In seven of 10 patients, the decrease in third ventricular volume exceeded the decrease in lateral ventricular volume. Repeated measurements indicated that the 95% confidence interval for the authors' calculations varied around the mean by 2.5% for third ventricular volume and 1.2% for lateral ventricular volume. Long-term outcome was excellent, with only one case of delayed failure. The mean follow-up duration was 12 months. CONCLUSIONS: Volumetric measurements calculated from standard CT scans will show a demonstrable decrease in ventricular volume soon after successful third ventriculostomy and can be helpful in assessing patients postoperatively. Although the third ventricle may exhibit a greater decrease, the lateral ventricular measurements are more accurate. Patients with more indolent symptoms show the smallest change.

Adolescent↗

[Maximum rate of left ventricular volume change--a parameter of ventricular function (author's transl)].

Peak left ventricular ejection rate (dV/dtsyst) and peak left ventricular filling rate (dV/dtdiast) were determined from biplane cineangiographies in patients with normal left ventricular function (n = 8), pressure overload (n = 11), aortic regurgitation (n = 7), mitral regurgitation (n = 9), mitral stenosis (n = 6), hypertrophic obstructive cardiomyopathy (n = 10), congestive cardiomyopathy (n = 9) and coronary heart disease (n = 17). dV/dtsyst (normal 642 +/- 187 ml s-1) was reduced in mitral stenosis (447 +/- 77 ml s-1) and was increased significantly in aortic regurgitation (1085 +/- 162 ml s-1) and mitral regurgitation (744 +/- 232 ml s-1). dV/dtsyst/EDV was correlated linearly with ejection fraction and was reduced significantly in mitral stenosis, aortic and mitral regurgitation, congestive cardiomyopathy and coronary heart disease. Ventricles with pressure overload and coronary heart disease could be separated better from normal ventricles by dV/dstsyst/EDV than by ejection fraction. dV/dtdiast (normal 549 +/- 205 ml s-1) was decreased significantly in mitral stenosis and increased in aortic regurgitation (1141 +/- 557 ml s-1) and mitral regurgitation (946 +/- 349 ml s-1). Peak left ventricular filling rate and diastolic stiffness were correlated by a hyperbolic function. The results show that peak left ventricular ejection and filling rates allow a more detailed analysis of ventricular function than the usually applied parameters. Quantification of the factors which determine the rate of change of left ventricular volume was only partially possible.

Aortic Valve Insufficiency↗

Effect of right ventricular volume overload on left ventricular diastolic function in patients with atrial septal defect.

This study was undertaken to investigate the effect of chronic right ventricular (RV) volume overload on left ventricular (LV) diastolic function. Twelve patients with atrial septal defect and 7 age-matched normal controls were examined. Patients with atrial septal defect were divided into 2 groups based on their Qp/Qs values (ASD1:Qp/Qs < or = 3, n = 7; ASD2:Qp/Qs > 3, n = 5). The LV volume curve and its first derivative were derived by a frame-by-frame analysis of the left ventriculogram. The peak filling rate was defined by the peak positive first derivative of the LV volume curve. We measured the time constant, isovolumetric relaxation time, stiffness constant and compliance at LV end-diastole. The time constant was significantly prolonged in the ASD2 group compared with the controls, and the isovolumetric relaxation time in both atrial septal defect groups was also prolonged compared with the controls. The peak filling rate, which was normalized by end-diastolic volume, was lower in the ASD2 group than in the controls. Although the stiffness constant and the compliance at LV end-diastole in the controls were not significantly different from those in the atrial septal defect group, an upward and leftward displacement of the left ventricular pressure-volume curve was observed in patients with atrial septal defect. Moreover, a significant correlation (r = 0.78, p < 0.01) was observed between the time constant and RV end-diastolic pressure. Thus, these results suggest that chronic RV volume overload affects left ventricular diastolic function.

Adult↗

Real-time three-dimensional echocardiography for measurement of left ventricular volumes.

Left ventricular (LV) volumes are important prognostic indexes in patients with heart disease. Although several methods can evaluate LV volumes, most have important intrinsic limitations. Real-time 3-dimensional echocardiography (RT3D echo) is a novel technique capable of instantaneous acquisition of volumetric images. The purpose of this study was to validate LV volume calculations with RT3D echo and to determine their usefulness in cardiac patients. To this end, 4 normal subjects and 21 cardiac patients underwent magnetic resonance imaging (MRI) and RT3D echo on the same day. A strong correlation was found between LV volumes calculated with MRI and with RT3D echo (r = 0.91; y = 20.1 + 0.71x; SEE 28 ml). LV volumes obtained with MRI were greater than those obtained with RT3D echo (126 +/- 83 vs 110 +/- 65 ml; p = 0.002), probably due to the fact that heart rate during MRI acquisition was lower than that during RT3D echo examination (62 +/- 11 vs 79 +/- 16 beats/min; p = 0.0001). Analysis of intra- and interobserver variability showed strong indexes of agreement in the measurement of LV volumes with RT3D echo. Thus, LV volume measurements with RT3D echo are accurate and reproducible. This technique expands the use of ultrasound for the noninvasive evaluation of cardiac patients and provides a new tool for the investigational study of cardiovascular disease.

Adult↗

The conductance volume catheter technique for measurement of left ventricular volume in young piglets.

The conductance catheter has been used extensively in the adult for instantaneous and continuous measurement of left ventricular volumes, but has not been validated for use in the small heart. To determine the accuracy of this technique, we simultaneously measured left ventricular volume by the conductance catheter and biplane cineangiography in nine piglets (2-5 wk of age) over a wide range of volumes experimentally altered by volume infusion, hemorrhage, inferior vena caval occlusion, or administration of phenylephrine, isoproterenol, or propranolol. We performed 110 comparisons and determined parallel conductance of contiguous structures (alpha Vc) for each comparison using the saline technique. End-systole and end-diastole volumes were estimated by angiography using Simpson's rule. Raw and alpha Vc-corrected conductance volumes were compared to simultaneously obtained angiographic volumes by multiple regression analyses, using dummy variable coding for the effects of the interanimal variability and the phase of the cardiac cycle. Raw conductance volumes correlated highly with the cineangiographic volumes (r = 0.97), and the coefficient of angiographic volumes was near identity (1.11 +/- 0.04). The phase of the cardiac cycle did not have a significant effect. However, alpha Vc-corrected conductance volumes correlated less (well (r = 0.85), probably related to the fact that estimated alpha Vc was found to vary with ventricular volume. Thus, the conductance catheter affords a very accurate technique for measuring instantaneous changes in ventricular volume in the small heart, although correction to absolute volumes using the saline technique for estimation of alpha Vc may induce some inaccuracy.

Animals↗

Left ventricular volume determined echocardiographically by assuming a constant left ventricular epicardial long-axis/short-axis dimension ratio throughout the cardiac cycle.

OBJECTIVES: The purpose of this study was to develop and test a simplified echocardiographic method to calculate left ventricular volume. BACKGROUND: This method was based on the assumption that the ratio of the left ventricular epicardial long-axis dimension to the epicardial short-axis dimension was constant throughout the cardiac cycle. With use of this constant ratio, the method developed to calculate left ventricular volume at a given point in the cardiac cycle required the left ventricular endocardial long-axis dimension to be measured at only one point in the cardiac cycle. METHODS: Studies were performed in 13 normal dogs, 8 normal puppies, 9 normal pigs, 12 dogs with aortic stenosis, 13 dogs with acute mitral regurgitation, 12 dogs with chronic mitral regurgitation, 7 dogs that had undergone mitral valve replacement and 6 pigs that had had chronic supraventricular tachycardia. Animals with aortic stenosis developed left ventricular pressure overload hypertrophy with a 60% increase in left ventricular mass; chronic mitral regurgitation caused left ventricular volume overload hypertrophy with a 46% increase in left ventricular volume; supraventricular tachycardia caused a dilated cardiomyopathy with a 55% decrease in left ventricular ejection fraction. RESULTS: The left ventricular epicardial long-axis/short-axis dimension ratio remained constant throughout the cardiac cycle in each animal group. End-diastolic and end-systolic volumes calculated with the simplified echocardiographic method correlated closely with angiographically measured volumes; for end-diastolic volume, echocardiographic end-diastolic volume = 1.0 (angiographic end-diastolic volume) -1.8 ml, r = 0.96; for end-systolic volume, echocardiographic end-systolic volume = 0.98 (angiographic end-systolic volume) -0.7 ml, r = 0.95. CONCLUSIONS: Thus the left ventricular epicardial long-axis/short-axis dimension ratio was constant throughout the cardiac cycle in a variety of animal species and age groups and in the presence of cardiac diseases that significantly altered left ventricular geometry and function. The simplified echocardiographic method examined provided an accurate determination of left ventricular volumes.

Animals↗

Validation of ultrafast computed tomographic left ventricular volume measurement.

Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomographic images and computed volume from sequential tomograms. There was no significant inter- or intraobserver difference in measurement of phantoms. Deviation of ultrafast computed tomographic volume from true phantom volume was -0.1 +/- 3.5% SD, range 9.0 to -7.6%. Correlation of true phantom volume with ultrafast computed tomographic volume was 0.99, SEE = 1.9 ml. No significant difference was observed between merged and single ultrafast computed tomographic scanning sequences. Left ventricular cast volume determined by ultrafast computed tomography deviated from true volume by 6% +/- 20%, range 54% to -45%. Correlation of true volume with ultrafast computed tomographic volume was 0.99, SEE = 5.1 ml. There was no interobserver significant difference in measurement of left ventricular cast volume. Correlation between ultrafast computed tomographic volume and cineradiographic volume of the same left ventricular casts was 0.99, SEE = 4.4 ml. Thus, phantom volumes can be measured accurately without significant intra- or interobserver variation. Merged scanning sequences did not influence volume determination. Left ventricular cast volume determination was comparable to that obtained with cineradiography.

Cardiac Volume↗

Echocardiographic prediction of left ventricular volume after myocardial infarction.

Left ventricular volume is a strong determinant of survival after acute myocardial infarction. The aim of this study was to determine which clinical and echocardiographic criteria assessed early after myocardial infarction would predict later left ventricular dilation. Forty-eight patients with uncomplicated transmural myocardial infarction had echocardiography 5 to 10 days after myocardial infarction and assessment of clinical variables including peak creatine kinase and sum of electrocardiographic ST segment elevation. Left ventricular dimensions were measured from the echocardiogram in the parasternal view and also in the apical four and two chamber views at the level of the mitral leaflets, papillary muscles and apex. A cardiac wall motion score was obtained by segmental analysis of the apical views. Echocardiographic left ventricular volume was measured after 1 year from the apical views with use of a Simpson's rule method. Initial clinical and echocardiographic variables were correlated with the left ventricular volume at 1 year. There was a significant relation between the initial four and two chamber end-diastolic dimensions and the left ventricular volume at 1 year, particularly for dimensions measured at the apical level (four chamber R2 = 0.66, p = 0.0001, two chamber R2 = 0.61, p = 0.0001). Other clinical variables, parasternal left ventricular dimensions and cardiac wall motion score were not significantly related to left ventricular volume. A powerful three variable model obtained by multiple regression and including the initial two chamber apical dimension, cardiac wall motion score and body surface area accounted for 82% of the variation in left ventricular volume at 1 year.

Cardiac Volume↗

Left ventricular volume and function after endoventricular patch plasty for dyskinetic anteroapical left ventricular aneurysm in sheep.

OBJECTIVE: Endoventricular patch plasty (the Dor procedure) has gained favor as a surgical treatment for heart failure associated with large anteroapical myocardial infarction. We tested the hypothesis that the Dor procedure reduces left ventricular volume, increases end-systolic elastance, decreases diastolic compliance, and maintains left ventricular function. METHODS: In 6 male Dorsett sheep, the left anterior descending coronary artery and its second diagonal branch were ligated 40% of the distance from apex to base. Sixteen weeks after myocardial infarction, a Dor procedure was performed with a Dacron patch that was 50% of the infarct neck dimension. Absolute left ventricular volume was measured with magnetic resonance imaging, and left ventricular pressure and relative left ventricular volume changes during pharmacologic preload reduction were measured with a volume conductance catheter 2 weeks before and 2 and 6 weeks after the Dor procedure. End-systolic elastance, diastolic compliance, and Starling relationships were calculated from the resultant left ventricular pressure/volume loops. RESULTS: Two weeks after the Dor procedure, the left ventricular volume at end systole and end diastole was significantly reduced, and there was no redilation at 6 weeks. Six weeks after the Dor procedure, the ejection fraction was significantly increased. Although stroke volume increased slightly at 6 weeks, the change was not significant. The slopes of end-systolic elastance, diastolic compliance, and Starling relationships were unchanged at 2 and 6 weeks. CONCLUSIONS: The Dor procedure significantly reduces left ventricular volume. Unlike linear repair, left ventricular volume changes seem stable. The ejection fraction is improved, and left ventricular function (stroke volume and the Starling relationship) is maintained.

Animals↗

[Differences in postoperative course by preoperative left ventricular volume after closure of ventricular septal defect during early infancy].

A total of 38 early infants with ventricular septal defect (VSD) were divided into 2 groups by preoperative LVEDV. The group A (n=14, LVEDV>250% N) showed significantly longer period of intubation, cathecholamine drip, and hospitalization compared with the group B (n=28, LVEDV<250% N). At dischage, both groups showed significant lowered right ventricular (RV) pressure, but LVSF in the group A was significantly lower than that in the group B. The patients with larger left ventricular (LV) volume preoperatively were thought to be potential high-risk groups in cardiac and pulmonary function and their postoperative course was prolonged and recovery of LV function was worse. In such patients, special care is mandatory to do postoperative management and to decide timing of operation.

Cardiac Volume↗

Quantitative cineangiographic analysis of ventricular volume and mass in patients with single ventricle: relation to ventricular morphologies.

With the use of biplane selective ventriculography, the ventricular volume, ejection fraction, and ventricular mass were evaluated in 28 patients with a single ventricle, and those with the left ventricular type (LV type, 12 patients) and right ventricular type (RV type, 16 patients) were compared. There were no significant differences in terms of age, hemoglobin, systemic oxygen saturation, or pulmonary-to-systemic flow ratio in the two groups. No patients with atrioventricular valve regurgitation were included. The ventricular cavity volume was calculated by the area-length method. The ventricular mass volume was determined as the shell volume created by subtracting the ventricular cavity volume from the total ventricular volume calculated by adding the free wall thickness to the chamber dimensions. The ventricular mass volume was converted to mass by multiplying by the gravity of the heart muscle. There was no significant difference between patients with the LV type and RV type of single ventricle with respect to the end-diastolic ventricular volume (188 +/- 53 and 179 +/- 61 ml/m2 in LV and RV types, respectively), end-systolic volume (88 +/- 31 and 84 +/- 27 ml/m2), or ejection fraction (0.54 +/- 0.06 and 0.52 +/- 0.06).(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Volume↗

A segmentation-based and partial-volume-compensated method for an accurate measurement of lateral ventricular volumes on T(1)-weighted magnetic resonance images.

Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement.

Brain↗

Left ventricular volume measurement by conductance catheter in intact dogs. Parallel conductance volume depends on left ventricular size.

The conductance catheter is a promising new instrument for continuously measuring left ventricular (LV) volume. Absolute LV volume (V[t]) is related to uncorrected conductance volume, B(t), according to the equation: V(t) = (1/alpha)(B(t) - alpha Vc). The alpha Vc factor represents parallel-conductance volume due to conducting material outside the LV blood pool, and may be estimated by transiently changing blood conductivity using a bolus injection of hypertonic saline. alpha is the slope in the relation between B(t) and true LV volume. We tested the assumption that alpha Vc and alpha are constant over a range of hemodynamic conditions. We performed multiple hypertonic saline alpha Vc determinations in seven intact dogs during control conditions and subsequent temporary balloon occlusions of inferior vena cava (IVCO), aorta (AO), and pulmonary artery (PAO). We also compared B(t) with simultaneous biplane angiographic LV volume during similar control and intervention conditions. The saline-derived alpha Vc was 76 +/- 2 ml during control and fell significantly by -7 +/- 2 ml during IVCO (p less than 0.001) but not during AO or PAO. According to multiple linear regression analyses, the strongest predictor of saline-derived alpha Vc was uncorrected end-systolic Bes, with a sensitivity coefficient of 0.60 +/- 0.06 ml/ml (p less than 0.001). Angiographically derived alpha Vc showed a similar dependence on Bes, with a coefficient of 0.77 +/- 0.14 ml/ml (p less than 0.001). Angiographically determined alpha also showed significant variation with hemodynamic interventions, largely reflecting an underlying dependence on alpha Vc. The variation in alpha Vc and alpha with LV size may stem from nonlinearity in the B(t)-V(t) relation. Although the conductance catheter provides a useful measure of relative LV volume, measurement of absolute LV volume over a wide hemodynamic range using constant alpha Vc and alpha factors is unrealistic. This result calls into question the current use of this technique for the measurement of the absolute end-systolic--pressure-volume relation.

Animals↗