PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Fixed”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

In vitro fracture resistance of four-unit fiber-reinforced composite fixed partial dentures.

OBJECTIVES: The aim of this in vitro study was to investigate the influence of glass fiber-reinforcement on the fracture resistance of four-unit composite fixed partial dentures (FPDs) in the posterior region. METHODS: A total of 70 FPDs were fabricated of the composites Sinfony, Vita Zeta and Targis. With each material, 10 FPDs were made without glass fiber-reinforcement and 10 were reinforced with the new glass fiber system EverStick. In addition, 10 FPDs were fabricated of the material combination Targis/Vectris. After thermocycling, all FPDs were loaded until failure in a universal testing machine. The FPDs were then cut and cross-sectional areas were examined by scanning electron microscopy (SEM). RESULTS: The load to fracture of the fiber-reinforced FPDs lay between 615 and 1191 N, which was significantly greater than the values found with unreinforced FPDs (between 178 and 307 N). The highest values were found with the combinations Targis/Vectris (1191 N) and Sinfony/EverStick (1137 N). SEM showed that the FPDs with EverStick reinforcement not only exhibited fracture lines in the fiber-composite interface, but also more often in the area of the fiber-reinforcement than was the case with the FPDs with Vectris reinforcement. The load to fracture was not significantly dependent on fiber quantity or course of fracture. SIGNIFICANCE: It may be concluded that the fracture resistance of four-unit composite FPDs can be significantly raised by glass fiber frameworks (p<0.05). The reinforcement effect of EverStick depended significantly on the composite used (p<0.05).

Composite Resins↗

Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties.

The purpose of this study was to determine changes in flexural properties of resin cement under simulated resin-bonded fixed partial denture (RBFPD) clinical conditions using aqueous ageing and cyclic loading. Panavia F flexural modulus and strength were measured by static loading to failure after 48-h and 60-day aqueous ageing at 37 degrees C with and without simulated cyclic occlusal loading. Panavia F sorption and solubility were also measured. Scanning electron microscopy (SEM) was used to characterize the morphology of the fractured surfaces. A two-factor anova (P </= 0.05) indicated that cyclic loading produced a significant increase in the flexural modulus with no significant effect on the flexural strength. Conversely, aqueous ageing time produced a significant decrease in flexural strength with no effect on the flexural modulus. The SEM fracture analysis indicated that resin matrix fracture occurred in static-aqueous specimens; while in the aqueous-cycled specimens, resin matrix fracture occurred in addition to an increasing proportion of filler/resin interface fracture. Collectively, these outcomes suggest that initial degradation under simulated resin cement clinical function may be related to breakdown of the filler/resin interface bond, which could contribute to in vivo RBFPD resin cement cohesive failure.

Analysis of Variance↗

Fracture resistance of the veneering on inlay-retained zirconia ceramic fixed partial dentures.

AIMS: The aim of this in vitro study was to evaluate the fracture load of zircon frames veneered with a polymer glass holding box inlay-retained fixed partial dentures (FPDs). The influence of the position of the frame and the span length was tested. Additionally, the fracture load values of zircon frames veneered with a press ceramic were evaluated. MATERIAL AND METHODS: Box inlay cavities were prepared on mandibular molars and premolars. Forty-eight FPDs were manufactured using industrially prefabricated zircon frames veneered with the polymer glass Artglass. Sixteen FPDs received individually manufactured CAD/CAM zircon frames veneered with a press ceramic. All FPDs underwent thermal cycling and mechanical loading (ML). The load to fracture was measured and fracture sites were evaluated. RESULTS: Four polymer veneered FPDs showed fractures in the veneering material after ML. The mean fracture resistance ranged from 531 N to 727 N. No significant influence of frame localization could be observed. Significantly greater fracture resistance values were found in the ceramic veneered FPDs (1276 N to 1413 N). There was no significant effect of span length in the polymer veneered group or in the all-ceramic group, with the exception of a significant peak in fracture load value for intermediate span lengths in the polymer group with a localized occlusal zircon frame. CONCLUSIONS: Polymer veneered FPDs with Y-TZP frames showed acceptable fracture resistance values, but they cannot yet be unreservedly recommended for clinical use. Fracture values for CAD/CAM manufactured Y-TZP frames combined with a press ceramic deserve further clinical investigation.

Composite Resins↗

Inlay-fixed partial dentures adhesively retained and reinforced by glass fibers: clinical and scanning electron microscopy analysis after five years.

Fifty-three posterior glass fibre-reinforced composite inlay-fixed partial dentures (IFPDs) in 36 patients were followed for 5 yr. For statistical analysis, one IFPD per patient was randomly selected. The survival rate and influence of discrete predictors (gender, location) and continuous variables (age, abutment surfaces) were determined. Clinical observations were recorded by using modified United States Public Health System (USPHS) criteria. Replicas of 17 randomly selected abutments were analysed by scanning electron microscopy (SEM) for marginal adaptation and the results were compared by using a repeated-measures analysis of variance (anova). The main reason for failure was veneering material delamination from the framework. The cumulative survival rate after 5 yr was 73% (95% confidence interval: 57-89%) for not delaminating and 96% (95% confidence interval: 88-100%) for not debonding. No significant influence of the tested predictors was found. Significant changes between baseline USPHS criteria and counterparts recorded at recall were fractures of the veneering material (chipping), wear, surface texture, and staining. Significant margin changes were only found between baseline and 1 yr. Thereafter, marginal adaptation remained stable. After 5 yr, 90% of the margins were termed as perfect. It was concluded that hard-tissue saving IFPDs with the current design maintained acceptable retention and marginal integrity. Future studies should aim at reducing delaminations by searching for improved framework designs and materials.

Adult↗

Retention of a posterior resin-bonded fixed partial denture with a modified design: an in vitro study.

PURPOSE: The aim of this study was to test in vitro the resistance of a modified resin-bonded fixed partial denture (RBFPD) to detachment using a laboratory setup simulating load fatigue of mastication forces. The effect of varying the cement type was also investigated. MATERIALS AND METHODS: Extracted teeth were used to prepare specimens each consisting of a premolar and a molar with a space equivalent to a molar in between. Five test groups were prepared (n = 7). Specimens in group 1 were prepared to receive conventional RBFPDs with proximal grooves, occlusal rests, and lingual wings. Specimens in groups 2 and 3 were prepared to receive modified RBFPDs with retentive-slot restorations. Specimens in group 4 were prepared to receive RBFPDs with retentive-slot restorations only, whereas specimens in group 5 were prepared similarly to the ones in groups 2 and 3 but with inlay preparations instead of the retentive slots. Castings were made and their fit surfaces microetched. In groups 1, 2, 4, and 5 castings were cemented with Cement-It, whereas castings of group 3 were cemented with Panavia 21. Slot cavities of groups 2, 3, and 4 were restored with a resin composite. Specimens were subjected to compressive load cycling for 230,000 cycles at 4 Hz under water. Castings were then separated from the abutments under tensile loading. RESULTS: Mean separation forces were: group 1 = 361 N, group 2 = 525 N, group 3 = 562 N, group 4 = 449 N, and group 5 = 417 N. Groups 2 and 3 had significantly higher mean separation forces than groups 1 and 5. Separation of castings in groups 2 and 3 was associated with a higher frequency of cohesive fracture of the abutments than in group 1. Adhesive failure was uncommon among specimens of groups 2, 3, and 4. CONCLUSION: The modified RBFPDs of groups 2 and 3 had better potential for retention. Increased resistance to dislodgment of the modified RBFPDs was not directly related to the surface area of the castings, nor was it related to the type of resin cement, but rather to mechanical interlocking of the castings with the retentive-slot resin composite restorations.

Analysis of Variance↗

Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures.

It is generally assumed that passively fitting superstructures are a prerequisite for long-lasting implant success. In the study presented, the strain development of three-unit implant fixed partial dentures (FPDs) was evaluated at the bone surrounding the implant and on the superstructure using a strain gauge technique. Six groups of three-unit FPDs representing the commonly used techniques of bridge fabrication were investigated with 10 samples each, in order to quantify the influence of impression technique, mode of fabrication and retention mechanism on superstructure fit. Two ITI implants (Straumann, Waldenburg, Switzerland) were anchored in a measurement model according to a real-life patient situation and strain gauges were fixed mesially and distally adjacent to the implants and on the bridge pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate two sample tests were performed setting the level of significance at P=0.1. None of the investigated bridges revealed a truly passive fit without strains occurring. About 50% of the measured strains were found to be due to impression taking and model fabrication, whereas the remaining 50% were related to laboratory inaccuracies. The two impression techniques used did not reveal any significant differences in terms of precision. Both modes of fixation--i.e. cement and screw retention--provoked equally high stress levels. In the fabrication of screw-retained FPDs, similar results were obtained from the use of burn-out plastic copings and the technique of casting wax moulds to premachined components. Bonding bridge frames onto gold cylinders directly on the implants significantly reduces strain development.

Aged↗

Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

The aim of this study was to compare the frequency of biological and technical complications with fixed partial dentures (FPDs) on implants, teeth and as mixed tooth-implant supported FPDs over 4 to 5 years of function. All implants belonged to the ITI Dental Implant System. Group I-I (implant FPD) included 33 patients with 40 FPDs, group T-T (tooth FPDs) 40 patients with 58 FPDs, group I-T (mixed tooth-implant FPDs) 15 with 18 FPD. Of the bridge abutments 144 were teeth and 105 were implants. The median number of units replaced by the FPDs was 3 (range 2-14). The mean age of the patients was 55.7 years (range 23-83). Complete failures resulted in the loss of one FPD in each group. Two implants were lost due to fracture secondarily to development of a bone defect. One tooth had a vertical fracture and 1 tooth was lost due to periodontitis. Biological complications (peri-implantitis, PPD > or = 5 mm and BOP+) occurred at 9.6% (10) of the implants. This number was, however, reduced to 5% if the threshold for definition of peri-implantitis was set at PPD > or = 6 mm and BOP+. Biological complications occurred in 11.8% (17) of the abutment teeth (NS compared to implants); 2.8% (4) had secondary caries, 4.9% (7) endodontic problems and 4.1% (6) had periodontitis (PPD > or = 5 mm, BOP+). Ten out of 32 patients with a general health problem indicated a biological complication, whereas 9 out of 53 patients with no general health problem had a biological complication (chi 2: NS). Statistically significantly more technical complications were found in FPDs on implants (chi 2, P < or = 0.05). The technical complications were associated with bruxism. Out of 10 bruxers 6 had a technical complication whereas 13 out of 75 non-bruxers had such a complication (chi 2 < or = 0.01). Extensions were associated with more technical complications (13 out of 35 with extensions versus 9 out of 81 without). In conclusion, favourable clinical conditions were found at tooth and implant abutments after 4-5 years of function. Loss of FPD over 4-5 years occurred at a similar rate with mixed, implant or tooth supported reconstructions. Significantly more porcelain fractures were found in FPDs on implants. Impaired general health status was not significantly associated with more biological failures but bruxism as well as extensions were associated with more technical failures.

Adult↗

Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.

In this study, the hypothesis was tested that the marginal and internal fit of CAD/CAM fabricated all-ceramic three-unit fixed partial dentures (FPDs) can be as good as in metal-ceramic FPDs. Twenty-four all-ceramic FPDs were fabricated and randomly subdivided into three equally sized groups. Eight frameworks were fabricated using the Digident CAD/CAM system (DIGI), another eight frameworks using the Cerec Inlab system (INLA). Vita Inceram Zirkonia blanks were used for both groups. In a third group frameworks were milled from yttrium-stabilized Zirconium blanks using the Lava system (LAVA). All frameworks were layered with ceramic veneering material. In addition, six three-unit metal-ceramic FPDs served as control group. All FPDs were evaluated using a replica technique with a light body silicone stabilized with a heavy body material. The replica samples were examined under microscope. The medians of marginal gaps were 75 microm for DIGI, 65 microm for LAVA and INLA and 54 microm for the conventional FPDs. Only the DIGI data differed significantly from those of the conventional FPDs. Within the limits of this study, the results suggest that the accuracy of CAD/CAM generated three-unit FPDs is satisfactory for clinical use.

Aluminum Oxide↗

Influence of framework design on fracture strength of mandibular anterior all-ceramic resin-bonded fixed partial dentures.

PURPOSE: The purpose of this in vitro study was to evaluate the influence of the framework design on the fracture strength of all-ceramic resin-bonded fixed partial dentures (RBFPD) in the mandibular incisor region. MATERIALS AND METHODS: Twenty-four aluminum oxide ceramic frameworks were copy milled with the Celay system, glass infiltrated, and veneered with feldspathic porcelain to replace a mandibular incisor. Forty-eight extracted human incisors were used as abutments by embedding them in a polyester resin. The master casts were fabricated according to a typical clinical case. The sandblasted restorations were bonded to the acid-etched abutment teeth with a composite resin. Twelve RBFPDs had a conventional two-retainer design, and 12 had a cantilevered single-retainer design. Subgroups of eight specimens were subjected to a quasistatic load in the direction of the long axis of the abutment teeth in a universal testing machine. Additional subgroups of four specimens were subjected under 0 degrees to dynamic loading of 25 N in a dual-axis chewing simulator. RESULTS: The mean fracture strengths under quasistatic loading were 313 N (SD 42) for the two-retainer design and 291 N (SD 100) for the single-retainer design. The mean cycles sustained by specimens subjected to dynamic loading at 25 N were 50,081 (SD 42,705) for the two-retainer design and 297,099 (SD 508,439) for the single-retainer design. There was no statistically significant influence of the framework design on the fracture strength of the restorations under quasistatic or dynamic loading. CONCLUSION: The clinical application of cantilevered all-ceramic RBFPDs in the mandible may be an alternative to all-ceramic RBFPDs with two retainers.

Acid Etching, Dental↗

Fiber-reinforced composite fixed partial denture to restore missing posterior teeth: a case report.

In patients refusing implant surgery for psychological reasons, when minimal tooth reduction is desired, a fiber-reinforced composite inlay fixed partial denture (IFPD) can be used to replace missing teeth. In comparison to other restorative systems this conservative approach carries a lower risk of pulp exposure and/or periodontal inflammation, maintaining the health of supporting tissues. The purpose of this case report is to describe the clinical procedure for fabricating an IFPD with a pre-impregnated glass fiber system and a hybrid composite. Fiber-reinforced composite, in combination with adhesive techniques, appears promising for an IFPD. Further clinical investigation will be required to provide additional information on this technique.

Bicuspid↗

The effects of resin-bonded and conventional fixed partial dentures on the periodontium: restoration type evaluated.

The purpose of this study was to compare the long-term and short-term periodontal response to three different modalities of fixed prosthodontic tooth replacement. Posterior proximal sites adjacent to abutment teeth supporting etched metal and two designs of conventional fixed partial dentures (FPDs) were assessed 6 months to 5 years after insertion. For the long-term observation, the etched metal resin-bonded FPDs had significantly greater plaque scores than both of the conventional designs. The resin-bonded FPD group had statistically, but not clinically, significant increased probing depths than the supragingival FPD group. In spite of the increased levels of supragingival plaque associated with the etched metal FPD, this type of fixed prosthesis was no more injurious to the periodontium than the subgingival conventional FPD designs.

Adult↗

A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years.

OBJECTIVES: The objective of this systematic review was to assess the 5- and 10-year survival of implant supported fixed partial dentures (FPDs) and to describe the incidence of biological and technical complications. METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on FPDs with a mean follow-up time of at least 5 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by two reviewers. Failure and complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 5- and 10-year survival proportions. RESULTS: The search provided 3844 titles and 560 abstracts. Full-text analysis was performed for 176 articles resulting in 21 studies that met the inclusion criteria. Meta-analysis of these studies indicated an estimated survival of implants in implant-supported FPDs of 95.4% (95 percent confidence interval (95% CI): 93.9-96.5%) after 5 and 92.8% (95% CI: 90-94.8%) after 10 years. The survival rate of FPDs supported by implants was 95% (95% CI: 92.2-96.8%) after 5 and 86.7% (95% CI: 82.8-89.8%) after 10 years of function. Only 61.3% (95% CI: 55.3-66.8%) of the patients were free of any complications after 5 years. Peri-implantitis and soft tissue complications occurred in 8.6% (95% CI: 5.1-14.1%) of FPDs after 5 years. Technical complications included implant fractures, connection-related and suprastructure-related complications. The cumulative incidence of implant fractures after 5 years was 0.4% (95% CI: 0.1-1.2%). After 5 years, the cumulative incidence of connection-related complications (screw loosening or fracture) was 7.3% and 14% for suprastructure-related complications (veneer and framework fracture). CONCLUSION: Despite a high survival of FPDs, biological and technical complications are frequent. This, in turn, means that substantial amounts of chair time have to be accepted by the clinician following the incorporation of implant-supported FPDs. More studies with follow-up times of 10 and more years are needed as only few studies have described the long-term outcomes.

Algorithms↗

The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature.

As a result of the successful use of ceramic crowns and patient demands for metal-free, tooth-colored restorations, ceramic systems for anterior fixed partial dentures (FPDs) have become available. Although numerous in vitro studies have been published, clinical studies that evaluate anterior ceramic FPDs are few and limited. This article reviews data on ceramic FPDs published between 1966 and 2001 in the English language. Peer-reviewed articles were identified through a MEDLINE search and a hand search of relevant textbooks and annual publications; abstracts were not considered for inclusion. The available data suggest that more clinical studies (preferably randomized clinical trials) that assess the long-term outcome of anterior ceramic FPDs are required to determine whether they can serve as a viable replacement for a maxillary anterior missing tooth and, at the same time, provide patients with a safe and effective restoration, oral health, and social comfort.

Ceramics↗

Communication between the dental laboratory technician and dentist: work authorization for fixed partial dentures.

PURPOSE: A questionnaire was sent to laboratory technicians to determine the level of communication between dentists and dental laboratories in specific areas of the work authorization forms for the fabrication of fixed partial dentures. MATERIALS AND METHODS: A select number of dental laboratories were randomly chosen from the National Association of Dental Laboratories (NADL) for each of the 50 states. The questionnaire was mailed to the laboratory directors for a total of 199 dental laboratories. The survey asked questions pertaining to the following areas of work authorization: legibility and thoroughness of prescriptions, patient information, choice of materials for the prosthesis, design of the prosthesis, and shade description. For each question, the number of responses received was tabulated and converted to a percentage. RESULTS: Of the 199 laboratories surveyed, 114 (57%) responded to the questionnaire. Results from this survey suggest that there is lack of communication between dentists and dental laboratories through work authorization forms regarding choice of metal alloy, type of porcelain to be used, and choice of margin and pontic design for the prosthesis. CONCLUSIONS: Information obtained from the responding laboratories included effectiveness of work authorization forms. There were some similar trends indicated by the large percentage of dental laboratories agreeing on lack of communication by the dentists as reflected by the work authorization forms.

Communication↗

A single-retainer zirconium dioxide ceramic resin-bonded fixed partial denture for single tooth replacement: a clinical report.

This clinical report describes a treatment for the replacement of a missing mandibular anterior tooth using a cantilever single-retainer resin-bonded fixed partial denture (RBFPD), fabricated from zirconium dioxide (ZrO2) ceramic. No clinical complications were observed at the 2-year 6-month follow-up examination after placement of the ZrO2 ceramic RBFPD, and satisfactory functional and esthetic results were achieved. A treatment modality using a cantilever ZrO2 ceramic RBFPD is an alternative for single anterior tooth replacement. Further clinical studies are required to evaluate the long-term potential of cantilever single-retainer ZrO2 ceramic RBFPDs.

Ceramics↗

In-Ceram fixed partial dentures: three-year clinical trial results.

In-Ceram is a sintered, high-alumina-content, glass-infiltrated ceramic core material reported to have sufficient strength for all-ceramic fixed partial dentures. While Vita/Vident recommends that In-Ceram should be used only for anterior FPDs, the purpose of this study was to push the sintered alumina material to its limits by testing posterior FPDs with premolar and molar pontics. This prospective clinical trial tested the longevity of 61 three-unit In-Ceram alumina FPDs. The failed specimens were analyzed to determine factors contributing to failure. The abutment teeth were prepared for full crown retainers with shoulder margins and 1.3 mm of axial reduction. All FPDs were cemented with an encapsulated glass ionomer. None of the patients reported postcementation sensitivity. During the three-year period, seven FPDs fractured through the connector area. By location of the pontic, failure rates were 0 percent for anteriors, 11 percent for premolars and 24 percent for molars. Based on the results of this clinical study at the three-year point, In-Ceram alumina can be reliably utilized for anterior FPDs as indicated by a 100 percent success rate. The findings do not support the use of In-Ceram alumina for posterior FPDs as was advised by the porcelain manufacturer. Glass ionomer cement can be predictably used to cement In-Ceram FPDs with few clinical side effects. Because of a technological malfunction, this article could not be presented with the others on ceramic restorations that appeared in the February issue.

Aluminum Oxide↗