At least 361 records · Page 20Linked to original sources

Treating aortic dissection and penetrating aortic ulcer with stent graft: thirty cases.

BACKGROUND: The purpose of this study is to evaluate the feasibility and safety of stent graft in the treatment of aortic dissection and penetrating aortic ulcer. METHODS: From June 2001 to April 2004, 25 patients with aortic dissection and 5 patients with penetrating aortic ulcer received stent-graft implantation. Within this group were 24 male and 6 female patients, with an average age of 52.3 +/- 11.9 years. One patient was diagnosed as type A dissection, 23 patients as chronic type B dissection, 1 patient as acute type B dissection, and the remaining 5 patients with penetrating aortic ulcer. Among the 25 patients with aortic dissection, 3 had contained rupture. All patients were followed up in 1 to 32 months. RESULTS: All patients received stent-graft implantation. There were 5 type I endoleaks. Retrograde ascending aortic dissection occurred during the operation in 1 patient. Two other retrograde ascending aortic dissections occurred in 2 patients 1 day and 7 days, respectively, after stent-graft implantation. Two patients died 1 day and 18 days, respectively, after operation because of rupture of ascending aortic dissection. One-month mortality rate was 6.7%. No death occurred during follow-up time. One patient received a second stent-graft implantation 20 months after the first procedure. CONCLUSIONS: Serious complications may develop after stent-graft implantation, but the early results of treatment of aortic dissection and penetrating aortic ulcer with stent graft were satisfactory. Long-term follow-up was needed.

Adult↗

Effects of the patent false lumen on the long-term outcome of type B acute aortic dissection.

OBJECTIVE: To determine the most effective treatment, we performed a detailed comparative study of the clinical course of patients with type B aortic dissection with a patent or thrombosed false lumen who did not undergo surgery in the acute period. We examined the effect of patency of the false lumen on outcome. METHODS: Computed tomography scans of 138 patients with type B acute aortic dissection were reviewed. Of 138 patients, 110 were medically treated and survived the acute period. We focused on the outcome of these 110 patients, 62 with medically treated thrombosed false lumen (thrombosed group) and 48 with medically treated patent false lumen (patent group). We investigated factors influencing outcome among the 110 patients. The follow-up period was up to 10 years after the onset of aortic dissection. The three study endpoints were death from any cause, dissection-related death (aortic rupture, perioperative death, or death due to organ ischemia), and a dissection-related event (aortic rupture or surgery). In the patent group, we investigated factors influencing long-term outcome. RESULTS: Patency of the false lumen was an independent risk factor for dissection-related death (P = 0.038, hazard ratio=5.6, confidence interval=1.1-28) and for a dissection-related event (P = 0.000, hazard ratio=7.6, confidence interval=2.7-22) but not for death from any cause (P = 0.769, hazard ratio=1.2, confidence interval=0.45-2.91). In the patent group, location of the most dilated aortic segment at the distal arch was an independent risk factor for dissection-related death (P = 0.026, hazard ratio=13.6, confidence interval=1.4-135) and for a dissection-related event (P = 0.048, hazard ratio=2.6, confidence interval=1.0-6.9). CONCLUSIONS: Patency of the false lumen is a strong independent prognostic factor for type B aortic dissection. Location of the most dilated aortic segment at the distal arch is a significant risk factor in the patients with a patent false lumen.

Acute Disease↗

Clinical and echocardiographic findings in patients with suspected acute aortic dissection.

OBJECTIVES: The objective of this study was to define the range of clinical presentations, echocardiographic findings, and underlying final diagnoses in patients with clinically suspected acute aortic dissection. METHODS AND RESULTS: This study was designed as a retrospective review of clinical and echocardiographic data in consecutive patients evaluated for clinically suspected acute aortic dissection. The study population consisted of 75 studies in 74 consecutive patients referred for urgent or emergency evaluation because of signs and symptoms suggesting acute aortic dissection. A history and physical examination designed to elicit the cause of chest pain, evidence of congestive heart failure, and other cardiovascular abnormalities was performed in each patient. All patients underwent transesophageal echocardiography by experienced operators. Routine 12-lead electrocardiograms and chest radiographs were available for review in the majority of patients. Magnetic resonance imaging or computed tomography was performed in only 5 (6%) and 34 (44%) patients, respectively. Contrast aortography was performed in 21 (27%) patients. For the entire patient cohort, the most prevalent symptom was chest pain alone (n = 31; 41%) or chest pain in conjunction with back pain (n = 23; 31%). Classic "tearing" pain was an infrequent symptom. Syncope or other neurologic findings were present in 15 (20%) patients. Acute aortic dissection was responsible for 34 (45%) of the 75 presentations, with 31 (41% of total evaluations, 92% of dissections) involving the ascending aorta (Stanford type A, DeBakey type 1 or 2). Alternate major cardiovascular diagnoses, including acute myocardial infarction, primary valvular disease, or pericardial disease, were established in 12 (16%) cases. Aortic pathology, other than dissection, was found in 15 (20%) cases. Transesophageal echocardiography established the diagnosis responsible for the symptoms in 61 (81%) cases. CONCLUSIONS: Symptoms in patients with acute aortic dissection are more variable than commonly recognized. Transesophageal echocardiography is an accurate primary diagnostic tool in patients with clinically suspected acute aortic dissection. It allows rapid diagnosis of dissection and can identify alternate cardiovascular pathology responsible for the symptoms in a significant number of patients without acute dissection.

Aged↗

Yearly rupture or dissection rates for thoracic aortic aneurysms: simple prediction based on size.

BACKGROUND: Prior work has clarified the cumulative, lifetime risk of rupture or dissection based on the size of thoracic aneurysms. Ability to estimate simply the yearly rate of rupture or dissection would greatly enhance clinical decision making for specific patients. Calculation of such a rate requires robust data. METHODS: Data on 721 patients (446 male, 275 female; median age, 65.8 years; range, 8 to 95 years) with thoracic aortic disease was prospectively entered into a computerized database over 9 years. Three thousand one hundred fifteen imaging studies were available on these patients. Five hundred seventy met inclusion criteria in terms of length of follow-up and form the basis for the survival analysis. Three hundred four patients were dissection-free at presentation; their natural history was followed for rupture, dissection, and death. Patients were excluded from analysis once operation occurred. RESULTS: Five-year survival in patients not operated on was 54% at 5 years. Ninety-two hard end points were realized in serial follow-up, including 55 deaths, 13 ruptures, and 24 dissections. Aortic size was a very strong predictor of rupture, dissection, and mortality. For aneurysms greater than 6 cm in diameter, rupture occurred at 3.7% per year, rupture or dissection at 6.9% per year, death at 11.8%, and death, rupture, or dissection at 15.6% per year. At size greater than 6.0 cm, the odds ratio for rupture was increased 27-fold (p = 0.0023). The aorta grew at a mean of 0.10 cm per year. Elective, preemptive surgical repair restored life expectancy to normal. CONCLUSIONS: This study indicates that (1) thoracic aneurysm is a lethal disease; (2) aneurysm size has a profound impact on rupture, dissection, and death; (3) for counseling purposes, the patient with an aneurysm exceeding 6 cm can expect a yearly rate of rupture or dissection of at least 6.9% and a death rate of 11.8%; and (4) elective surgical repair restores survival to near normal. This analysis strongly supports careful radiologic follow-up and elective, preemptive surgical intervention for the otherwise lethal condition of large thoracic aortic aneurysm.

Adolescent↗

Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.

BACKGROUND: The treatment of thoracic aortic dissection is guided by prognostic and anatomical information. Proximal dissection requires surgery, but the appropriate treatment of distal thoracic aortic dissection has not been determined, because surgery has failed to improve the prognosis. METHODS: We prospectively evaluated the safety and efficacy of elective transluminal endovascular stent-graft insertion in 12 consecutive patients with descending (type B) aortic dissection and compared the results with surgery in 12 matched controls. In all 24 patients, aortic dissection was diagnosed by magnetic resonance angiography. In each group, the dissection involved the aortic arch in 3 patients and the descending thoracic aorta in all 12 patients. With the patient under general anesthesia, either surgical resection was undertaken or a custom-designed endovascular stent-graft was placed by unilateral arteriotomy. RESULTS: Stent-graft placement resulted in no morbidity or mortality, whereas surgery for type B dissection was associated with four deaths (33 percent, P=0.09) and five serious adverse events (42 percent, P=0.04) within 12 months. Transluminal placement of the stent-graft prosthesis was successful in all patients, with no leakage; full expansion of the stents was ensured by balloon inflation at 2 to 3 atm. Sealing of the entry tear was monitored during the procedure by transesophageal ultrasonography and angiography, and thrombosis of the false lumen was confirmed in all 12 patients after a mean of three months by magnetic resonance imaging. There were no deaths or instances of paraplegia, stroke, embolization, side-branch occlusion, or infection in the stent-graft group; nine patients had postimplantation syndrome, with transient elevation of C-reactive protein levels and body temperature plus mild leukocytosis. All the patients who received stent-grafts recovered, as did seven patients who underwent surgery for type B dissection (58 percent) (P=0.04). CONCLUSIONS: These preliminary observations suggest that elective, nonsurgical insertion of an endovascular stent-graft is safe and efficacious in selected patients who have thoracic aortic dissection and for whom surgery is indicated. Endoluminal repair may be useful for interventional reconstruction of thoracic aortic dissection.

Adult↗

Predictability of aortic dissection as a function of aortic diameter.

The role of aortic diameter on the occurrence of type A dissection was investigated in 73 patients with dilated ascending aorta at the time of pre-operative evaluation. Using transthoracic echocardiography for diagnosis and measurements, 54 patients were identified with type A dissection (group 1) and 19 without dissection (group 2). The true mean aortic diameters were identical (6.0 +/- 1.3 cm in group 1 and 6.4 +/- 1.4 cm in group 2; mean +/- SD; ns) as were the indexed aortic diameters (ratio of diameter/body surface area; 3.2 +/- 0.8 cm.m-2 and 3.4 +/- 0.7 cm.m-2, respectively; ns). However, the individual diameters showed a pronounced scatter in both groups (range from 3.6 +/- 11.0 cm). Of the 73 patients, 66 had surgery (47/54 with and 19/19 without dissection) and seven patients were treated medically. Emergency surgery was performed in 45/66 patients (all with acute type A dissection) and elective repair in 21/66 (19 without and two with chronic type A dissection). In-hospital mortality was 18% in the emergency group, 5% in the elective group and 57% in the medical group. It is concluded that patients with dilated ascending aorta have a substantial incidence of acute dissection. Their clinical course is unpredictable: acute dissection occurs in some, and in others the ascending aorta continues to enlarge without dissection. Because patients with dissection often arrive too late for elective repair and have to be operated on as emergencies with a higher operative risk, we recommend elective surgery before the diameter of the ascending aorta has reached 6 cm.

Aortic Dissection↗

Malaria sporozoite detection by dissection and ELISA to assess infectivity of afrotropical Anopheles (Diptera: Culicidae).

Malaria infection rates determined by dissection and Plasmodium falciparum enzyme-linked immunosorbent assay (ELISA) were compared for 26,935 Anopheles gambiae Giles sensu lato and 17,739 Anopheles funestus Giles collected during 20 mo in western Kenya. ELISA infection rates were about 43% higher than dissection sporozoite rates. In dissection-negative Anopheles, circumsporozoite (CS) protein was detected by ELISA in 5.2% of 10,017 salivary gland samples and in 12.2% of 237 thorax samples. The accuracy of dissection and ELISA techniques was compared by the following tests on a group of 352 field-collected Anopheles (held 10 d to ensure sporogonic development): salivary gland dissection, examination of Giemsa-stained dissection slides, ELISA tests on salivary gland and thorax body parts, and microscopic techniques for determining sporozoite loads. Respective infection rates were 9.9%, 10.8%, and 15.6% for dissection, stained slides, and ELISA. Sporozoite loads were associated significantly with ELISA absorbance values (r = 0.76). Compared with Giemsa-stained dissection slide results, the sensitivity of sporozoite detection was 92.1% for dissection compared with 78.9% for ELISA; specificity was 100.0% for dissection versus 92.0% for ELISA. Immunological detection of CS protein in head-thorax samples of Afrotropical vectors overestimated the proportion of infective Anopheles because the comparison of techniques indicated that 45.4% of the ELISA positive Anopheles did not contain salivary gland sporozoites.

Animals↗

Renal artery dissection.

Renal artery dissections are stenotic or occlusive lesions most often observed in hypertensive patients with underlying atherosclerosis or fibromuscular disease. Acute dissections may present spontaneously, as a complication of diagnostic or therapeutic angiography or as an agonal event associated with overwhelming systemic illness. Chronic dissections may produce renovascular hypertension or be entirely asymptomatic. Fourteen renal artery dissections have been encountered in nine patients treated at Vanderbilt University Medical Center during the past decade. Eleven dissections have been found in seven patients with renovascular hypertension. Seven of these dissections were chronic (six functional, one silent) and four acute (two spontaneous, two secondary to angiography). Three agonal dissections were found in two additional patients postmortem: one at autopsy and bilateral dissections found at the time of cadaveric donor nephrectomy. Ten bypass procedures, including five complex branch reconstructions of which three were performed ex vivo, have been performed with 100% immediate patency and maintenance or improvement of renal function. Long-term follow-up of these patients has shown sustained patency of the reconstructed renal arteries, excellent blood pressure control, and normal renal function in all. Nephrectomy has not been required and there have been no associated deaths. Seventy-seven additional renal artery dissections in 72 patients collected from previous reports have been analyzed. Patient survival (55/72, 76.4%) and preservation of the involved kidney in surviving patients (26/55, 47.3%) were low in these earlier series. In addition, renal failure was associated with 59% of the deaths. The lethality of renal artery dissections and the ease and success of revascularization, which preserves renal function and ameliorates associated renovascular hypertension, emphasize the need for an aggressive approach to the recognition and treatment of this entity. Therapy should be directed toward arterial reconstructions and the preservation of functioning renal tissue.

Adult↗

Water jet dissection in neurosurgery: experimental results in the porcine cadaveric brain.

OBJECTIVE: Water jet dissection is currently under investigation as a new tool for use in neurosurgical procedures. The safety of this instrument has already been demonstrated. However, precise data demonstrating highly accurate tissue dissection in the brain in combination with vessel preservation are still missing. METHODS: In this study, 50 porcine cadaveric brains were dissected with the use of several nozzle types (80-150 in microm diameter, coherent straight or helically turned jet) and several levels of water jet pressure (1-40 bars). The dissection characteristics in various brain regions and the basilar artery were evaluated morphologically. RESULTS: The best results regarding reliable function, dissection accuracy, and the correlation of water jet pressure with dissection depth were obtained with the 120-microm Helix Hydro-Jet nozzle. An almost linear relationship of pressure increase with dissection depth was demonstrated. The dissection depth varied significantly up to threefold, depending on the area investigated (greatest resistance was in the brainstem, followed by hemispheres and then the cerebellum). Vessels including the basilar artery resisted pressure up to 15 bars in most cases, whereas the basilar artery was dissected significantly more often with higher pressure. CONCLUSION: The results indicate that 1) use of the water jet enables very precise and reliable brain parenchyma dissection with vessel preservation under conditions corresponding to the clinical situation, and 2) the nozzle type and water jet pressure must be selected carefully according to the brain area and tissue targeted. This study provides the morphological basis for further research with the use of the water jet technique in the brain. The water jet's characteristics may make this device a useful addition to the neurosurgical armamentarium.

Animals↗

An experimental model of Stanford type B aortic dissection.

PURPOSE: To create an experimental model of aortic dissection with a long-lasting patent false lumen as a proper animal model for development of less-invasive treatment for aortic dissection. MATERIALS AND METHODS: Fifteen adult beagle dogs (weight, 10-12 kg) were used. The descending aorta was exposed by a left thoracotomy at the sixth intercostal space. The entry for the aortic dissection was created surgically just distal to the origin of the left innominate artery and the reentry was 5 cm distal to the entry point. Normal saline solution was injected into the aortic wall (ie, media) between these two points to create the dissection. The dogs were followed up at 1 day, 3 months, 1 year, and 2 years. RESULTS: All 12 surviving dogs had completely patent true and false lumina without any thrombi. Microscopic examination showed that the dissection was created in the tunica media layer, making it identical to aortic dissection in humans. Color Doppler imaging confirmed the patency of the true and false lumina and the relatively narrowed true lumen. CONCLUSION: In this canine model of aortic dissection, the false lumen has excellent long-term patency and the dissection plane is histologically similar to that in human aortic dissection. This model may contribute to the development of new treatments for Stanford type B aortic dissection.

Aortic Dissection↗

Lymph node metastasis from 259 papillary thyroid microcarcinomas: frequency, pattern of occurrence and recurrence, and optimal strategy for neck dissection.

OBJECTIVE: To determine the frequency and pattern of lymph node metastasis (LNM) from papillary thyroid microcarcinoma (PTMC) and the results of node dissection, and to establish the optimal strategy for neck dissection in these patients. SUMMARY BACKGROUND DATA: Most PTMCs carry a favorable prognosis, but a few present with palpable lymphadenopathy. Patients with LNM are at risk for nodal recurrence, although they do not have higher mortality. The frequency and pattern of LNM from PTMC and the results of node dissection are not well established. METHODS: The frequency and pattern of LNM from 259 PTMCs were analyzed according to the size and location of the primary tumor. Of the 259, 24 with palpable nodes underwent therapeutic node dissection and the other 235 patients without palpable nodes underwent prophylactic node dissection. The authors compared the results of node dissection between the therapeutic group and the prophylactic group, and between PTMCs 5 mm or smaller and PTMCs larger than 5 mm. The authors also compared nodal recurrence between the prophylactic group and a no-lymph-node-dissection group (155 PTMCs). RESULTS: Overall, 64.1% (166/259) and 44.5% (93/209) had node involvement of the central and ipsilateral lateral compartment, respectively. Pretracheal (43.2%), ipsilateral central (36.3%), and ipsilateral mid-lower (37.8%) jugular were more commonly involved. LNM was more frequent in the therapeutic group than in the prophylactic group (95.8% vs. 60.9% for central compartment, 83.3% vs. 39.5% for ipsilateral lateral compartment). Nodal recurrence was more common in the therapeutic group than in the prophylactic group (16.7% vs. 0.43%), but did not differ between the prophylactic group and the no-dissection group (0.43% vs. 0.65%). The tumor size did not influence nodal recurrence. Nodal recurrence preferentially occurred in ipsilateral mid-lower jugular nodes. CONCLUSIONS: Patients who have PTMC presenting with palpable lymphadenopathy should have therapeutic node dissection. Prophylactic node dissection is not beneficial in those without palpable lymphadenopathy.

Adolescent↗

Transoesophageal echocardiography as the sole diagnostic investigation in patients with suspected thoracic aortic dissection.

OBJECTIVES: To assess the value and limitations of using transoesophageal echocardiography as the sole diagnostic test in patients with suspected thoracic aortic dissection. DESIGN: Retrospective data review over a two year period. SETTING: A regional cardiothoracic centre. PATIENTS: Data were compiled from admission records, surgical records, and lists of patients undergoing diagnostic investigations in the hospital. Patient's notes were used to identify presentation, management, and outcome. INTERVENTIONS: Patients were managed according to the policy of our unit, which is to treat patients with dissection affecting the ascending aorta by an operation. Patients with uncomplicated dissection sparing the ascending aorta are initially managed medically. MAIN OUTCOME MEASURES: In hospital and two year follow-up of patients who were investigated by transoesophageal echocardiography alone. RESULTS: Of 48 patients referred, 45 underwent transoesophageal echocardiography. Dissection was confirmed in 22 patients. Transoesophageal echocardiography showed the proximal extent of the dissection in 21/22 (96%) and only one patient required a further diagnostic investigation. Ten patients with dissection of the ascending aorta underwent graft replacement of the ascending aorta; operative mortality was 10% and their two year survival was 80%. Of the eight patients with dissection of the descending aorta, six were discharged home, and five were alive at two years. No patient without evidence of dissection on their initial transoesophageal echocardiographic examination required re-investigation into possible dissection in the two years after discharge. CONCLUSIONS: In patients with suspected thoracic dissection transoesophageal echocardiography rapidly and safely gives all the necessary diagnostic information. Further investigations, including coronary angiography, before surgery are unnecessary.

Adult↗

Aortic dissection caused by angiographic procedures.

PURPOSE: To describe findings in, and the clinical course and outcome of, aortic dissection (dissecting aneurysm) caused by angiographic procedures. MATERIALS AND METHODS: The records of approximately 15,500 angiographic procedures performed between 1985 and 1991 were reviewed. In the six cases of iatrogenic aortic dissection identified, computed tomography (CT) was performed for diagnosis, follow-up, or both. RESULTS: The type of aortic dissection was Stanford type A in three patients and Stanford type B in three patients. The sites of injury were the abdominal aorta (n = 2), right brachiocephalic artery (n = 2), middle of the thoracic aorta (n = 1), and right common iliac artery (n = 1). One patient had anterograde dissection from the site of injury; two patients, retrograde dissection; and three patients, extensive dissection that extended in both anterograde and retrograde directions. Retrograde dissections decreased in size or disappeared in 1-3 months due to the absence of reentry, whereas anterograde dissections persisted during follow-up (15-27 months). All patient were treated without surgery. CONCLUSION: Angiographers should be aware of this potentially serious complication. The extent and type of the aortic dissection can be determined with CT.

Aged↗

Usefulness of transesophageal echocardiography in assessment of aortic dissection.

BACKGROUND: The value of transesophageal echocardiography in the assessment of patients with aortic dissection was studied. METHODS AND RESULTS: Group 1 (34 patients) represented all patients studied at our institution with this technique in whom aortic dissection was proven by aortography, surgery, or autopsy. Group 2 (27 patients) represented all patients studied with this technique at our institution in whom aortic dissection was excluded by aortography. Transesophageal echocardiography made a correct diagnosis of aortic dissection in 33 of 34 patients (sensitivity, 97%; specificity, 100%). It also correctly demonstrated the type of dissection in all 29 patients with aortographic or surgical proof. On the other hand, computed tomography scanning, performed in 24 of 34 patients in group 1, made a correct diagnosis in only 67% of patients and misclassified the type of dissection in 33%. Transesophageal echocardiography correctly identified involvement of the coronary arteries by aortic dissection in six of seven patients as well as absence of both left and right coronary artery involvement in 10 patients with aortic dissection. This technique was also useful in detecting communications between the true and false lumens, presence of thrombi in the false lumen, and, in two patients, localized dissection rupture with formation of a false aneurysm. In both groups 1 and 2, transesophageal echocardiography correctly identified patients with moderate to severe aortic regurgitation. CONCLUSIONS: Transesophageal echocardiography is very useful in the assessment of aortic dissection.

Aortic Dissection↗

Surgical management of aortic dissection during a 30-year period.

BACKGROUND: Certain recent studies have demonstrated improved surgical outcome in patients with aortic dissection. We analyzed the surgical survival rates of patients with acute aortic dissections and the late prognosis of those with aortic dissection during a 30-year period. METHODS AND RESULTS: Between 1963 and 1992, 360 patients (256 men and 104 women; mean +/- 1 SD age, 57 +/- 14 years) underwent surgery for aortic dissection: 174 patients had an acute type A (AcA), 46 an acute type B (AcB), 106 a chronic type A (ChA), and 34 a chronic type B (ChB) aortic dissection. The overall operative mortality rate was 24 +/- 8% (26 +/- 3% for AcA, 39 +/- 8% for AcB, 17 +/- 4% for ChA, and 15 +/- 6% for ChB, [+/- 70% confidence limit]). The operative mortality rates for patients with acute aortic dissection (AcA or AcB) were assessed for five time "windows": 1963 to 1972 (42 +/- 8%), 1973 to 1977 (37 +/- 8%), 1978 to 1982 (15 +/- 6%), 1983 to 1987 (27 +/- 6%), and 1988 to 1992 (26 +/- 6%). Logistic regression analysis suggested that the low operative mortality rate during the 1978-to-1982 interval occurred by chance. Multivariate analysis showed earlier operative year, hypertension, cardiac tamponade, renal dysfunction, and older age were independent determinants of operative death. Actuarial survival rates (including early deaths) after 5, 10, and 15 years for AcA patients were 55%, 37%, and 24%; for AcB, 48%, 29%, and 11%; for ChA, 65%, 45%, and 27%; and for ChB, 59%, 45%, and 27%. Multivariate analysis revealed that older age and previous operation were significant predictors for late death. Freedom from reoperation for all patients was 84%, 67%, and 57% at 5, 10, and 15 years, respectively. CONCLUSIONS: Although the operative mortality rate decreased over time for patients with aortic dissection, the risk for those with acute aortic dissection during the last 10 years (1983 to 1992) is probably more realistic than that observed in the preceding 5-year interval (1978 to 1982). The operative mortality rates for patients with chronic aortic dissection have remained relatively static. Earlier diagnosis of acute aortic dissection before development of cardiac tamponade and renal impairment is critical to improve the operative salvage rate. Long-term outcome still is not optimal, which emphasizes the need for better serial postoperative aortic imaging surveillance and medical follow-up and blood pressure control.

Adult↗

Coexistence of fibromuscular dysplasia and cystic medial necrosis in a patient with Marfan's syndrome and bilateral carotid artery dissections.

BACKGROUND: A primary arteriopathy is suspected in most patients with spontaneous dissections of the carotid artery, although the nature of this arteriopathy usually remains elusive. Angiographic changes of fibromuscular dysplasia (FMD), however, are found in 10% to 20% of patients with carotid dissections. CASE DESCRIPTION: A 26-year-old woman with Marfan's syndrome presented with bilateral amaurosis fugax after surgical repair of an aortic dissection. Angiography revealed a dissection extending from the ascending aorta into the right internal carotid artery and, separate from the aortic dissection, a dissection of the left internal carotid artery. After surgery, microscopic examination of the right carotid artery revealed a medial dissection but no evidence of an underlying arteriopathy, while the left internal carotid artery displayed the typical features of FMD. Eighteen months later the patient died after resection of a large thoracoabdominal aortic dissecting aneurysm. Microscopic examination of the aorta revealed moderately extensive cystic medial necrosis. CONCLUSIONS: Carotid dissections associated with Marfan's syndrome may be the result of an extension of an aortic dissection or occur isolated from the aorta, even in the same patient. The occurrence of FMD in a patient with Marfan's syndrome in conjunction with previous reports of FMD in a variety of connective tissue disorders suggests that FMD, like cystic medial necrosis, may be a nonspecific disease entity.

Adult↗

Familial aorto-cervicocephalic arterial dissections and congenitally bicuspid aortic valve.

BACKGROUND: A primary arteriopathy is often implicated in the etiology of spontaneous cervicocephalic arterial dissections, but its exact nature usually remains unknown. We describe the familial occurrence of spontaneous arterial dissections and congenitally bicuspid aortic valve (BAV) and propose a common developmental defect in these families. SUMMARY OF REPORT: In the first family, a 63-year-old man suffered an extracranial internal carotid artery (ICA) dissection, and his 43-year-old cousin with BAV suffered an intracranial vertebral artery (VA) dissection. Two other family members had pathologically proven BAV. In the second family, a 31-year-old woman suffered bilateral extracranial ICA and VA dissections. Her father, at age 46, suffered an aortic dissection associated with cystic medial necrosis and BAV. Her paternal uncle died from an aortic dissection at age 59. In the third family, a 39-year-old woman suffered extracranial ICA and VA dissections, and her brother died at age 48 from an aortic dissection associated with a BAV. CONCLUSIONS: The familial occurrence of spontaneous arterial dissections and BAV suggests a common developmental defect. The aortic valvular cusps and the arterial media of the aortic arch and its branches are derived from neural crest cells, suggesting that a neural crest defect may be the underlying abnormality in these families.

Adult↗

Evaluation of extracranial vertebral artery dissection with duplex color-flow imaging.

BACKGROUND AND PURPOSE: We describe the diagnostic potential of duplex color-flow imaging in the evaluation of extracranial vertebral artery dissection. METHODS: Twenty patients with 24 extracranial vertebral artery dissections (four bilateral) were examined with duplex ultrasonography over a period of 6 years. Color-flow imaging was carried out in 16 of these patients. In 15 patients (75%), the dissection was temporally related to trauma. Angiography was available in 18 patients, confirming the diagnosis. RESULTS: In 15 patients, the diagnosis was primarily established with ultrasonography. Five patients with a dissection were referred for follow-up color-flow examinations. Six vertebral arteries were dissected at the origin or in the proximal V1 segment, one in the distal V2 segment, and one at the atlas loop. In contrast to other studies, the most frequent localization of the dissection in our patients was the region between the V1 and V2 segments (n = 16), where the most typical dissection site was the entrance of the artery into the transverse foramen of the C6 vertebra (n = 11). Typical ultrasonographic findings were irregular stenosis, dissecting membrane with true and false lumen, localized increase in diameter of the artery, pseudoaneurysm, intramural hematoma, and tapering stenosis with distal occlusion. In follow-up examination, a good regression of pathological findings was found in 17 dissections (70.8%). Two occlusions were completely recanalized. CONCLUSIONS: Extracranial vertebral artery dissections can be diagnosed noninvasively with duplex color-flow imaging. It is therefore a useful method for early diagnosis and follow-up examination.

Adolescent↗